Code of Colorado Regulations
1000 - Department of Public Health and Environment
1007 - Hazardous Materials and Waste Management Division
6 CCR 1007-3 - HAZARDOUS WASTE
Part 261 - HAZARDOUS WASTE - IDENTIFICATION AND LISTING OF HAZARDOUS WASTE
Subpart C - Characteristics of Hazardous Waste
Section 6 CCR 1007-3-261.22 - Characteristic of corrosivity
Universal Citation: 1000 CO Code Regs 6 CCR 1007-3-261.22
Current through Register Vol. 47, No. 17, September 10, 2024
(a) A solid waste exhibits the characteristic of corrosivity if a representative sample of the waste has either of the following properties:
(1) It is aqueous and has a pH less than or
equal to 2 or greater than or equal to 12.5, as determined by a pH meter using
Method 9040C in "Test Methods for Evaluating Solid Waste, Physical/Chemical
Methods, "EPA Publication SW-846, as incorporated by reference in § 260.11
of these regulations.
(2) It is a
liquid and corrodes steel (SAE 1020) at a rate greater than 6.35 mm (0.250
inch) per year at a test temperature of 55°C (130°F) as determined by
Method 1110A in "Test Methods for Evaluating Solid Waste, Physical/Chemical
Methods, "EPA Publication SW-846, as incorporated by reference in § 260.11
of these regulations.
(b) A solid waste that exhibits the characteristic of corrosivity has the EPA Hazardous Waste Number of D002.
Disclaimer: These regulations may not be the most recent version. Colorado may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.