California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 7 - General Industry Safety Orders
Group 8 - Points of Operation and Other Hazardous Parts of Machinery
Article 69 - Food and Tobacco Machinery
Section 4530 - Bakery Ovens
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
(a) General Oven Requirements.
EXCEPTIONS: Coal and other solid fueled fire ovens and ovens with heating systems that supply a total input of not exceeding 150,000 Btu/hour (44 kW).
(b) Fired Ovens. Fired ovens shall be safeguarded against failure of fuel, air or ignition. Automatically controlled gas or oil fired equipment shall have a safety pilot mechanism installed by the manufacturer and so arranged that fuel will be shut off to both the main burner and pilot burner in case of failure of the pilot burner flame or of the spark igniter.
(c) Recirculating Ovens.
1. New
section filed 2-20-80; effective thirtieth day thereafter (Register 80, No.
8).
2. New subsection (a)(2), subsection renumbering and amendment
of newly designated subsection (a)(5) filed 5-1-2009; operative 5-31-2009
(Register 2009, No. 18).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.