Universal Citation: 8 CA Code of Regs 3623

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) Units shall be designed to comply with the requirements of Section 3622.

(b) Scaffolds shall be braced by cross braces or diagonal braces, or both, for securing vertical members together laterally. The cross braces shall be of a length that will automatically square and align vertical members so the erected scaffold is always plumb, square, and rigid.

(c) Spacing of panels or frames shall be consistent with the loads imposed. The frames shall be placed one on top of the other with coupling or stacking pins to provide vertical alignment of the legs.

(d) Where uplift may occur, panels shall be locked together vertically by pins or other equivalent means.

1. New NOTE filed 10-12-84 (Register 84, No. 41).

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.