California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 7 - General Industry Safety Orders
Group 26 - Driving and Pressurized Worksite Operations
Article 153 - Commercial Diving Operations
Section 6061 - Specific Operations Procedures

Universal Citation: 8 CA Code of Regs 6061

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) Mixed-Gas Diving.

(1) General. Employers engaged in mixed-gas diving shall comply with the following requirements, unless otherwise specified.

(2) Limits. Mixed-gas diving shall be conducted only when:
(A) A decompression chamber is ready for use at the dive location; and
1. A bell is used at depths greater than 220 fsw or when the dive involves inwater decompression time of greater than 120 minutes, except when heavy gear is worn or when diving in physically confining spaces; or

2. A closed bell is used at depths greater than 300 fsw, except when diving is conducted in physically confining spaces, or heavy-gear diving up to 350 fsw.

(3) Procedures.
(A) A separate dive team member shall tend each diver in the water.

(B) A standby diver shall be available while a diver is in the water.

(C) A diver shall be stationed at the underwater point of entry when diving is conducted in enclosed or physically confining spaces.

(D) Each diving operation shall have a primary breathing gas supply sufficient to support diving for the duration of the planned dive including decompression.

(E) Each diving operation shall have a dive-location reserve breathing gas supply.

(F) When heavy gear is worn:
1. An extra breathing gas hose capable of supplying breathing gas to the diver in the water shall be available to the standby diver; and

NOTE: The pneumofathometer hose, if equivalent to the breathing gas hose in strength and flow capacity and properly plumbed to breathing gas source, will be considered satisfactory for this purpose.

2. An underwater stage shall be provided to divers in the water.

(G) An inwater stage shall be provided for divers without access to a bell for dives deeper than 100 fsw or outside the no-decompression limits.

(H) When a closed bell is used, one dive team member in the bell shall be available and tend the diver in the water.

(I) Except when heavy gear is worn or where physical space does not permit, a diver-carried reserve breathing gas supply shall be provided for each diver:
1. Diving deeper than 100 fsw or outside the no-decompression limits; or

2. Prevented by the configuration of the dive area from directly ascending to the surface.

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.