Section 5300 - Firing Switches
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
(a) The firing switch shall conform to the following minimum standards:
(b) When firing by means of a light or power circuit, the circuit shall be open at all times in at least one place by an air gap of at least 5 feet underground and 15 feet on the surface, between the firing and the auxiliary switches at all times, except during the actual firing operation. The air gap shall be established by means of a cable and 2-pole plug and receptacle of adequate capacity. The plug shall be provided with a device, preferably of automatic type, to short-circuit the wires when the plug is removed from the receptacle.
(c) The shot firing switch shall be no less than 1,000 feet from the face of a tunnel if the tunnel length exceeds 1,000 feet.
(d) For tunnels less than 1,000 feet in length, the shot switch shall be outside the portal.
1. New subsections (c)-(d) and new NOTE filed 7-11-2003; operative 8-10-2003 (Register 2003, No. 28).