California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 7 - General Industry Safety Orders
Group 1 - General Physical Conditions and Structures
Article 4 - Access, Work Space, and Work Areas
Section 3271 - Openings
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
(a) Openings to attics, furred ceiling spaces, and underfloor spaces shall not be less than 22 inches by 30 inches.
(Title 24, Par 2, Section 2-3320(f))
EXCEPTIONS:
(b) When the opening is less than 4 feet in any dimension, the appliance or equipment shall not be located more than 20 feet from the opening.
(Title 24, Part 2, Section 2-3320(g))
(c) Where for inspection or maintenance it is necessary to pass through roof and ceiling trapdoors which are of such size and weight that to open or close them subjects an employee to the risk of injury, they shall be constructed and maintained so that they can be easily opened and closed from a safe working position.
(Title 24, Part 4, Section 4-504)
1.
Amendment filed 7-16-76; effective thirtieth day thereafter (Register 76, No.
29).
2. Amendment filed 2-26-85; effective thirtieth day thereafter
(Register 85, No. 9).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code; and Section 18493(c), Health and Safety Code.