California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 7 - General Industry Safety Orders
Group 1 - General Physical Conditions and Structures
Article 2 - Standard Specifications
Section 3234 - Fixed Industrial Stairs
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
(a) Scope. This Section contains specifications for the safe design and construction of fixed general industrial stairs. This classification includes interior and exterior stairs around machinery, tanks, and other equipment, and stairs leading to or from floors, platforms, or pits. This Section does not apply to stairs used for required exit purposes, to construction operations, to private residences, or to articulated stairs, such as may be installed on floating roof tanks or on dock facilities, the angle of which changes with the rise and fall of the base support. (Title 24, Part 2, Section 2-3326(a).)
(b) Where Fixed Stairs Are Required.
(Title 24, Part 2, Section 2-3326(b).)
(c) Stair Strength. Fixed stairways shall be designed and constructed to carry a load of 5 times the normal live load anticipated but never of less strength than to carry safely a moving concentrated load of 1,000 pounds. (Title 24, Part 2, Section 2-3326 ().)
(d) Stair Width. Fixed stairways shall have a minimum usable width of 22 inches. No chute or open conveyor shall be parallel to and adjoin a stairway unless the usable width of the stairway is at least 22 inches and the stairway is equipped with a stair railing separating the chutes and open conveyors from the stairway.
Chutes shall not be hinged or otherwise constructed or used so as to cover stairways. (Title 24, Part 2, Section 2-3326(d).)
(e) Angle of Stairway Rise.
Table IS-1.
Angle to Horizontal | Rise (in inches) | Tread Run (in inches) |
30°35' | 6 1/2 | 11 |
32°08' | 6 3/4 | 10 3/4 |
33°41' | 7 | 10 1/2 |
35°16' | 7 1/4 | 10 1/4 |
36°52' | 7 1/2 | 10 |
38°29' | 7 3/4 | 9 3/4 |
40°08' | 8 | 9 1/2 |
41°44' | 8 1/4 | 9 1/4 |
43°22' | 8 1/2 | 9 |
45°00' | 8 3/4 | 8 3/4 |
46°38' | 9 | 8 1/2 |
48°16' | 9 1/4 | 8 1/4 |
49°54' | 9 1/2 | 8 |
Welded bar grating treads without nosings are acceptable providing the leading edge can be readily identified by personnel descending the stairway and provided the tread is serrated or is of definite non-slip design.
The maximum variations in the height of risers or the width of treads in any one flight shall be one-fourth-inch.
(Title 24, Part 2, Section 2-3326(e).)
(f) Stairway platforms shall be no less than the width of a stairway and minimum of 30 inches in length measured in the direction of travel. (Title 24, Part 2, Section 2-3326(f).)
(g) Stair Railings and Handrails.
(h) Vertical Clearance. Vertical clearance above any stair tread to an overhead obstruction shall be at least 6 feet 6 inches measured from the leading edge of the tread.
In existing installations where the overhead clearance is less than 6 feet 6 inches, the obstruction shall be removed, or if this is impracticable, a suitable warning shall be placed near the obstruction so as to notify employees of its presence. Where the nature of the hazard is such that padding it will increase safety, this also shall be done. (Title 24, Part 2, Section 2-3326(h).)
(i) Alternating Tread Stairs.
EXCEPTION: The installation of a midrail and toeboard is not required.
1. New
section filed 6-20-75; effective thirtieth day thereafter (Register 75, No.
25).
2. Amendment filed 7-16-76; effective thirtieth day thereafter
(Register 76, No. 29).
3. Amendment of subsection (g) filed 10-5-77;
effective thirtieth day thereafter (Register 77, No. 41).
4.
Amendment of subsection (h) and repealer of subsection (i) and Figure IS-1
filed 7-26-78; effective thirtieth day thereafter (Register 78, No.
30).
5. Amendment filed 5-25-83; effective thirtieth day thereafter
(Register 83, No. 22). Approved by State Building Standards Commission
1-24-83.
6. Amendment of subsection (b)(4) and new subsection (i)
filed 6-3-85; effective thirtieth day thereafter (Register 85, No.
23).
7. Amendment of subsections (e)(4) and (f) filed 7-8-85;
effective thirtieth day thereafter (Register 85, No. 28).
8.
Editorial correction of subsection (f) filed 8-29-85; effective thirtieth day
thereafter (Register 85, No. 35).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.