California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 6 - Elevator Safety Orders
Group IV - Conveyance Installations for Which the Installation Contract Was Signed on or After May 1, 2008
Article 41 - Conveyances Covered by ASME A17.1-2004
Section 3141.8 - Electric Conveyances
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
Electrical conveyances shall comply with the following:
(a) A means of access to the governor from outside the hoistway as required by ASME A17.1-2004, section 2.1.3.1.2(b)(1), is not required provided that:
(b) A hoistway is not required to have a floor above it per ASME A17.1-2004, section 2.1.3.1.1, if there is no machine room or other room above the hoistway that requires entry to perform functions such as maintenance, inspections, estimates by consultants, etc.
(c) A stop switch complying with section 2.26.2.5(a) through (c) of ASME A17.1-2004 shall be placed at a readily accessible location adjacent to the elevator driving machine if the driving machine is located in the hoistway.
(d) A car top emergency exit shall not be permitted on an elevator installed in a partially enclosed hoistway.
1. New section filed 4-1-2008; operative 5-1-2008 (Register 2008, No. 14).
Note: Authority cited: Sections 142.3 and 7323, Labor Code. Reference: Sections 142.3 and 7323, Labor Code.