Section 3137 - Seismic Requirements for Elevators, Escalators and Moving Walks
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
Elevators shall comply with the seismic requirements for elevators in Part XXIV of ASME A17.1-1996, except for Rule 2409.1b(1), which is hereby incorporated by reference.
(a) Earthquake protective devices shall be designed, arranged, and maintained to ensure that if any component fails, the elevator will go into the earthquake-sensed mode and be removed from service in the same manner as though an earthquake were occurring, and that the elevator will so remain until the faulty component has been repaired and the system is again arranged to work as intended.
(b) For hospital buildings, the earthquake sensing device shall activate upon excitation in a horizontal or vertical direction of not more than 0.5 g.
(c) Earthquake protection devices shall be arranged to be checked once a year for satisfactory operation and shall be calibrated at intervals recommended by the manufacturer.
(d) The following requirements apply to escalators and moving walks and are in addition to the requirements contained in other parts of this code:
1. New article 37 (section 3137) and section filed 9-25-98; operative 10-25-98 (Register 98, No. 39).
2. Amendment of article heading, subsections (d)(2)(C) and (d)(4)(C) and NOTE filed 4-1-2008; operative 5-1-2008 (Register 2008, No. 14).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.