California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 6 - Elevator Safety Orders
Group III - Installations Defined by Section 3000(f) of these Orders. Elevator Installations for Which the Installation Contract Was Signed on or After October 25, 1998, but Before May 1, 2008
Article 26 - Escalators
Section 3126.5 - Operating and Safety Devices

Universal Citation: 8 CA Code of Regs 3126.5

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

Operating and safety devices shall comply with Section 805 of ASME A17.1-1996, except for Rule 805.3n(1), which is hereby incorporated by reference.

(a) Means shall be provided to open the power circuit to the escalator driving machine motor and brake if a horizontal force exceeding 400 lb/ft is applied in the direction of travel at either side, or exceeding 800 lb/ft at the center of the front edge of the combplate.

(Title 24, Part 7, Section 7-3126.5.)

1. New section filed 9-25-98; operative 10-25-98 (Register 98, No. 39).

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code; and Section 18943(b), Health and Safety Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.