California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 6 - Elevator Safety Orders
Group II - Elevator Installations for Which the Installation Contract Was Signed Before October 25, 1998
Article 9 - Hydraulic Elevators
Section 3070 - Terminal Stopping Devices
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
(a) Normal Terminal Stopping Devices.
Normal terminal stopping devices shall be provided, conforming to the requirements of Section 3039(a).
EXCEPTIONS:
(b) Emergency Terminal Stopping Devices. Emergency terminal stopping devices shall be installed at the top of the hoistway for rated car speeds of more than 100 feet per minute and shall conform to the following:
EXCEPTION: Where the plunger is provided with a device to retard the car to 100 feet per minute, with a retardation not greater than gravity, before the plunger reaches its extreme limit of travel, emergency terminal stopping devices are not required.
(c) Final Terminal Stopping Devices. Final terminal stopping devices are not required.
(Title 24, Part 7, Section 7-3070)
1. New NOTE filed 12-8-86; effective thirtieth day thereafter (Register 86, No. 50).
2. New EXCEPTION 3. to subsection (a), statement prior to NOTE and amendment of NOTE filed 3-9-93; operative 4-8-93 (Register 93, No. 11).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code; and Section 18943, Health and Safety Code.