California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 6 - Elevator Safety Orders
Group II - Elevator Installations for Which the Installation Contract Was Signed Before October 25, 1998
Article 17 - Manlifts
Section 3098 - Construction Requirements for Manlifts Arranged for Side Loading
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
(a) Enclosures. The enclosures for the manlift shall comply with the requirements of Section 3097(a).
(b) Floor Openings. The floor openings through which the steps of a manlift pass shall be the same size as and form no ledges with the walls required by Section 3098(f) and shall have the edge of the opening on the loading side not more than 9 inches nor less than 7 inches from the edge of the up or down steps.
(c) Landings. The landings shall comply with the requirements of Section 3097(c).
(d) Floor Opening Guards. On the ascending side of the manlift, all landings shall be provided with a bevel guard on the open side. The angle of bevel and construction of the guard shall comply with the requirements of Section 3097(d)(1).
(e) Protection of Entrances and Exits to Steps.
(f) Special Runways for Side Loading.
The enclosure shall extend from the bottom landing to the floor level at the top landing on the up side of the manlift and from the second landing to not less than 6 feet above the top floor on the down side. The enclosures on the up and down sides shall be located parallel to the face of the belt not more than 15 inches nor less than 14 inches from the nose of the steps and shall extend not less than the full width of the floor openings.
FIGURE 3098-A
(g) Bottom Arrangement. The bottom landing on the down side shall be arranged with a platform for side unloading similar to that at the upper floors and for front unloading on floor supporting the boot pulley. No wall or other obstruction shall be within 6 feet of the face of the down side belt at the bottom landing measured at right angles to the face of the belt. The ascending side shall be arranged with a platform for loading similar to that at upper floors and above the point at which the upper surface of the ascending step assumes a horizontal position.
(h) Top Arrangement.
(i) Emergency Exit Ladders.Emergency exit ladders shall be provided where required by and shall comply with the requirements of Section 3097(i).
(j) Illumination. The lighting shall comply with the requirements of Section 3097(j).
(k) Electrical Wiring and Equipment. The electrical equipment shall comply with the requirements of Section 3097(k).
(l) Access to and Work Space for Machinery. The access and work space shall comply with the requirements of Section 3097 (l).
(Title 24, Part 7, Section 7-3098)
1. Amendment of subsection (g) filed 6-23-77; effective thirtieth day thereafter (Register 77, No. 26).
2. Amendment filed 6-12-87; operative 7-12-87 (Register 87, No. 26).
3. Editorial corrections (Register 95, No. 34).
4. Change without regulatory effect amending subsection (f)(1) to provide more legible illustrations in Figure 3098-A filed 5-1-2009 pursuant to section 100, title 1, California Code of Regulations (Register 2009, No. 18).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.