California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 6 - Elevator Safety Orders
Group II - Elevator Installations for Which the Installation Contract Was Signed Before October 25, 1998
Article 16 - Hand Power Man Platforms
Section 3095 - Hoistway Construction
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
(a) Enclosures. Hoistways shall be substantially enclosed to a height of not less than 6 feet above all floors on the sides not used for entrances, and from floor to ceiling except for the necessary entrances on the sides opposite any car entrance.
(b) Counterweight Enclosure. The counterweight shall be enclosed for its entire travel, and no passageway shall be permitted under the counterweight.
(c) Protection of Entrances. All hoistway entrances shall be equipped with self-closing gates not less than 5 feet 6 inches high, constructed to conform to the requirements of Section 3020(c).
(d) Top Clearance.
(e) Hoistway Clearance. The horizontal car and counterweight clearances shall comply with Section 3018 except the requirements of Section 3018(g).