California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 6 - Elevator Safety Orders
Group II - Elevator Installations for Which the Installation Contract Was Signed Before October 25, 1998
Article 15 - Special Access Elevators and Special Access Lifts
Section 3093.7 - Guarding of Suspension Means

Universal Citation: 8 CA Code of Regs 3093.7

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) Ropes and chains passing through a floor or stairway outside the hoistway enclosure shall be enclosed with a solid or openwork enclosure. If of openwork, the enclosure shall reject a ball 1/2 in. (13 mm) in diameter. Means for inspection shall be provided. The floor openings shall not be larger than is necessary to clear the suspension means.

(b) Ropes and chains immediately adjacent to a stairway shall be guarded with solid or openwork panels on the stair side. Openwork panels shall reject a ball 1/2 in. (13 mm) in diameter. EXCEPTION to subsection 3093.7(b): Ropes or chains which operate within a guide or track shall be considered suitably guarded.

(Title 24, Part 7, Section 7-3093.7)

1. New section filed 7-22-86; effective thirtieth day thereafter (Register 86, No. 36).
2. Amendment of section heading and section filed 8-29-2001; operative 9-28-2001 (Register 2001, No. 35).

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.