California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 6 - Elevator Safety Orders
Group II - Elevator Installations for Which the Installation Contract Was Signed Before October 25, 1998
Article 12.3 - Special Purpose Personnel Elevators
Section 3085.6 - Counterweights [Rule 1500.5]

Universal Citation: 8 CA Code of Regs 3085.6

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) Where a counterweight runway is not in the same hoistway as the car, an enclosure meeting the requirements of Section 3085.1 shall be provided.

(b) Access shall be provided for inspection, maintenance and repair of an enclosed counterweight and its ropes. Doors in the counterweight enclosures shall be self-closing and shall be provided with:

(1) An electric contact, the opening of which will remove power from the elevator driving machine motor and brake; and

(2) A self-locking keyed tumbler lock. [1500.5b]

(c) When the counterweight is in the same hoistway as the car, a guard meeting the requirements of subsection 3013(b) shall be provided.

(Title 24, Part 7, Section 7-3085.6)

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.