California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 6 - Elevator Safety Orders
Group II - Elevator Installations for Which the Installation Contract Was Signed Before October 25, 1998
Article 12.3 - Special Purpose Personnel Elevators
Section 3085.4 - Pits, Runby, and Top Clearances [Rule 1500.3]
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
(a) Pits.
(b) Protection of spaces below hoistways not extending to the lowest level of the structure shall conform to the applicable requirements of Section 3019. [1500.3b]
(c) Bottom runby shall conform to the requirements of subsections 3017(a), (b), (c) and (d). [1500.3c]
(d) There shall be a clearance of not less than 30 in. (762 mm) from the highest projection of the car top and/or the crosshead and the nearest part of the overhead structure, when the counterweight is resting on its fully compressed buffer. For rack and pinion elevators without counterweights, there shall be a clearance of not less than 30 in. (762 mm) from the highest projection of the car top and the nearest part of the overhead structure, when the car has reached the uppermost limit of its travel. [1500.3d]
(e) A floor conforming to the requirements of subsection 3010(d) shall be provided at the top of the hoistway. [1500.3e]
(Title 24, Part 7, Section 7-3085.4)
1. Editorial correction of subsection (a)(4) (Register 95, No. 34).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.