California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 6 - Elevator Safety Orders
Group II - Elevator Installations for Which the Installation Contract Was Signed Before October 25, 1998
Article 12.3 - Special Purpose Personnel Elevators
Section 3085.15 - Car Enclosures [Rule 1502.5]
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
(a) Except at the entrance, cars shall be fully enclosed with metal at sides and top. The enclosure at the sides shall be solid or of openwork which will reject a ball of 1 in. (25 mm) in diameter. Glass, or other transparent materials, if used as part of the enclosure, shall comply with the requirements of subsection 3034(b)(5). The minimum clear height inside the car shall be 78 in. (1.98 m). [1502.5a]
(b) The car enclosure shall be secured to the platform in such a manner that it cannot work loose or become displaced in regular service. [1502.5b]
(c) Each car shall be provided with an electric light and a light control switch. The light shall provide illumination of at least 2 1/2 foot candles (27 1x) at the landing edge of the car platform. Car lights and convenience outlets shall be fed from a separate branch circuit, independent of the motor circuit power feeders. [1502.5c]
(d) When car size and construction permit, an emergency exit with a cover shall be provided in the top of the elevator car enclosure conforming to the following requirements:
(e) Where the machine or control panel are located on the car top, the following shall be provided:
(Title 24, Part 7, Section 7-3085.15)
1. Editorial correction of subsection (b) (Register 95, No. 34).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.