(a) Positive means, such as momentary contact (continuous pressure) switches, shall be used to raise or rotate elevating antennas, such as microwave masts, dishes, or similar structures. The switch shall be located to assure that personnel operating the elevating antenna will be where they can continuously and responsibly observe the environment overhead during the raising or rotating operation.
(b) Level indication devices shall be provided in an observable location on the ENG vehicle to indicate the level of the vehicle front to rear and across the width.
(c) A spotlight or functionally equivalent means of illumination shall be provided on all ENG vehicles equipped with an elevating antenna, such as a microwave mast, dish, or similar structure. Illumination shall be adequate to assist operating personnel in locating overhead hazards, such as power lines within the proximity of the elevating device during periods of darkness or reduced available light.
(d) Audible and visual warnings shall be provided to warn the driver when movement of the ENG vehicle is attempted while the mast, dish, or similar structure (antenna) is not stowed. A visual warning readily observable to the driver shall occur when the engine is running and the antenna is not stowed. A non-cancelable audible alarm with a nominal sound loudness of 80-85dB at the driver's position shall occur when movement of the vehicle is attempted unless the elevating antenna is stowed.
(e) Warning Signs. Each ENG vehicle equipped with elevating mast, dish, antenna, or similar apparatus, shall be posted with durable, permanent warning signs.
(f) ENG Vehicle Safety Manual:
(g) Work performed as described in this Article shall be in accordance with Article 37 of the High-Voltage Electrical Safety Orders.
(h) Effective dates:
1. New section filed 11-18-2002; operative 12-18-2002 (Register 2002, No. 47).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.