Section 2561.2 - Special Requirements for Particular Locations
Combustible Materials. Where a crane or hoist operates over readily combustible material, the resistors shall be placed in a well ventilated cabinet composed of noncombustible material so constructed that it will not emit flames or molten metal.
EXCEPTION: Resistors shall be permitted to be located in a cage or cab constructed of noncombustible material which encloses the sides of the cage or cab from the floor to a point at least 6 inches above the top of the resistors.