Section 1713 - Framed Panels and Concrete Forms

Universal Citation: 8 CA Code of Regs 1713

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) Framed panels for structures shall be securely anchored, guyed, or braced to prevent them from falling.

(b) Form panels for concrete structures shall be securely anchored, guyed, or braced to prevent them from falling or collapsing.

(1) Panels and forms exceeding 500 pounds shall have lifting attachments with a safety factor of 4.

(2) Nailed lifting attachments shall not be used.

(c) Reinforcing steel shall not be used as a guy or brace to support framed panels or concrete forms from falling.

(d) The application of form release oil or oil to horizontal formwork shall not be done until the carpentry work on the form has been completed.

1. Renumbering from section 1714 filed 11-1-73; effective thirtieth day thereafter (Register 73, No. 44).
2. Amendment filed 6-21-85; effective thirtieth day thereafter (Register 85, No. 25).
3. Amendment of section heading filed 1-16-92; operative 2-17-92 (Register 92, No. 12).
4. Amendment of section heading and subsections (b)(1) and (c) and new subsection (d) filed 10-26-2017; operative 1-1-2018 (Register 2017, No. 43).

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.