California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 4 - Construction Safety Orders
Article 22 - Scaffolds-Various Types
Section 1653 - Bricklayers' Square Scaffolds

Universal Citation: 8 CA Code of Regs 1653

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) The squares shall not exceed 5 feet in width and 5 feet in height.

(b) Members shall be not less than those specified in the Schedule below: (See Plate B-32, Appendix)

Minimum Dimensions for Bricklayers' Square Scaffold Members

MembersDimensions
Ledgers or horizontal members.................................................... 2 x 6 in.
Legs.................................................... 2 x 6 in.
Braces at corners.................................................... 1 x 6 in.
Braces diagonally from center frame.................................................... 1 x 8 in.

(c) The squares shall be reinforced on both sides of each corner with 1- x 6-inch gusset pieces. They shall also have diagonal braces 1 x 8 inches on both sides running from center to center of each member, or other means to secure equivalent strength and rigidity.

(d) The squares shall be set not more than 5 feet apart for medium duty scaffolds, and not more than 8 feet apart for light duty scaffolds. Bracing, 1 x 8 inches, extending from the bottom of each square to the top of the next square, shall be provided on both front and rear sides of the scaffold.

(e) Platform planks shall be at least 2- x 10-inch nominal size. The ends of the planks shall overlap the ledgers of the squares and each plank shall be supported by not less than three squares.

(f) Bricklayers' square scaffolds shall not exceed three tiers in height and shall be so constructed and arranged that one square shall rest directly above the other. The upper tiers shall stand on a continuous row of planks laid across the next lower tier and be nailed down or otherwise secured to prevent displacement.

(g) Scaffolds shall be level and set upon a firm foundation.

(h) For guardrailing requirements see Section 1621.

1. New section filed 11-14-75; effective thirtieth day thereafter (Register 75, No. 46).
2. Amendment of subsection (b) and new subsection (h) filed 7-24-87; operative 8-23-87 (Register 87, No. 33).

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.