California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 4 - Construction Safety Orders
Appendix B - Handy Construction Data; Facts; and Information
Plate B-9 - Square Columns-Unbraced Rough Lumber-Not Surfaced

Universal Citation: 8 CA Code of Regs Plate B-9
Current through Register 2024 Notice Reg. No. 38, September 20, 2024

Suggested Maximum Loads in Pounds -- 1,000 Pounds per Square Inch Douglas Fir

SIZE OF COLUMN CROSS SECTION

Length in Feet4"x4"6"x6"8"x8"10"x10"12"x12"14"x14"16"x16"
515,30036,00064,000100,000144,000196,000256,000
614,60035,40064,000100,000144,000196,000256,000
713,50034,90063,400100,000144,000196,000256,000
811,80034,10062,900100,000144,000196,000256,000
9 9,60033,00062,300 98,900144,000196,000256,000
10 7,80031,50061,500 98,400144,000196,000256,000
11 6,40029,40060,200 97,600142,400196,000256,000
12 5,40026,70058,700 96,700141,700194,200256,000
14use a20,10054,300 93,800139,600192,800258,700
16larger size15,40047,400 89,400136,600190,700251,900
18 use a38,400 83,100132,200187,300249,300
20larger size31,100 74,200126,100183,000246,000

1. Change without regulatory effect correcting error in Plate B-9 filed 5-28-91 pursuant to section 100, Title 1, California Code of Regulations (Register 91, No. 27).

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.