Nails and Spikes.

(1) Safe Lateral Strength. A common wire nail driven perpendicular to grain of the wood, when used to fasten wood members together, shall not be subjected to a greater load causing shear and bending than the safe lateral strength of the wire nail or spike as set forth in Plate B-30-a.

A wire nail driven parallel to the grain of the wood or toe nailed shall not be subjected to more than two-thirds of the lateral load allowed when driven perpendicular to grain.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.