California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 20 - Tunnel Safety Orders
Article 6 - Illumination and Lasers
Section 8415 - Illumination

Universal Citation: 8 CA Code of Regs 8415

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) All tunnels, shafts, and general underground work areas shall be illuminated by an electric lighting system or natural light, equivalent to at least five-foot-candles intensity and ten-foot-candles at the heading area.

(b) In completed areas of tunnels where occasional work is conducted, the invert or walking surface shall be illuminated to at least two (2) foot-candles.

(c) All switches, transformers, telephone stations, hoist landings, car passers and similar areas shall be illuminated to at least five (5) foot-candles.

EXCEPTION: Tunnel repair jobs of short duration or tunnels 8 feet or less in diameter and less than 1,000 feet in length may use electric cap lamps, or equivalent, provided the illuminating device is worn by all persons going underground.

(d) Each person underground shall have a portable hand light or cap lamp available for emergency use unless natural light or emergency lighting systems are adequate for escape.

1. Amendment of section and new NOTE filed 3-5-96; operative 4-4-96 (Register 96, No. 10).

Note: Authority cited: Sections 142.3 and 7997, Labor Code. Reference: Sections 142.3 and 7997, Labor Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.