(a) (G-2, G-3) Openings in platforms to permit the passage of men climbing the derrick ladder shall be provided as follows:

(1) The width of the openings parallel to the ladder width shall be at least twenty-two inches (22") but not more than thirty inches (30"). The ladder shall be placed midway along the width of the opening.

(2) The openings shall be clear and unobstructed to a distance of at least twenty inches (20") outward from the front of the ladder rungs or steps.

(3) There shall be a clearance of at least twenty inches (20") between platform railings and toeboards and the ladder rungs or steps.

(4) Exception: Platforms installed on G-2 derricks before June 13, 1952, and not having the clearances required in paragraphs (2) and (3) of this subsection, will be allowed a two inch (2") minus tolerance.

1. New NOTE filed 5-8-95; operative 6-7-95 (Register 95, No. 19).

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.