Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) (G-2, G-3) On every derrick used for drilling, redrilling, or well servicing, a continuous platform at least two feet (2') wide shall be provided completely around the outer edges of the derrick crown. The outer edges of the platform shall be equipped with standard railings and with toeboards at least twelve inches (12") high.

(b) (G-2, G-3) The derrick crown platform shall be at an elevation that will provide access to the crown block.

(c) If a (G-1) derrick is used for drilling or redrilling, it shall conform to the requirements of this section.

1. New NOTE filed 5-8-95; operative 6-7-95 (Register 95, No. 19).

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.