California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 13 - Logging and Sawmill Safety Orders
Article 8 - Logging Machines
Section 6305 - A-Frames, Towers, Masts, Etc

Universal Citation: 8 CA Code of Regs 6305

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) A-frames, towers, and masts shall be of design and construction that provides adequate structural strength, and of sufficient vertical clearance or height for positive control of material or loads.

(b) The apex and base of A-frames and similar devices shall be secured to prevent displacement.

(c) The A-frame shall be guyed with two back guys and one front guy or snap line. In lieu of a snap line, a back stiff leg may be used.

(d) Where mobile A-frames, towers, masts, or similar devices are used, all rigging on such devices shall be inspected; worn or defective parts shall be replaced or repaired before the devices are raised or used on each respective setting.

(e) Rigging shall conform to the requirements of Article 7.

1. Editorial correction of subsection (e) filed 3-11-81 (Register 81, No. 11).

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.