California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 13 - Logging and Sawmill Safety Orders
Article 17 - Lath, Shingle, and Shake Mills
Section 6402 - Bolters and Lath Machines

Universal Citation: 8 CA Code of Regs 6402

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) Bolters and lath machines shall be provided with a shield of no less than 2-inch wood or equivalent material and built in front of the machines.

(b) Lath bolters and lath mill saws shall be provided with a metal hood guard no less than 1/8 -inch thick. These hoods may be hinged so that they can be turned back to permit changing the saws.

(c) A substantial metal plate baffle, finger device, or other acceptable device shall be installed to prevent kickbacks.

(d) Feed rolls and feed mechanisms shall be arranged so that it is not necessary to push the stock through the machine. The feed rolls shall not be raised while any employee is in line with the saws.

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.