California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 13 - Logging and Sawmill Safety Orders
Article 15 - Sawmills
Section 6365 - Conveyors

Universal Citation: 8 CA Code of Regs 6365

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) Troughs in which the working strands of a conveyor operate shall be of ample dimension and strength to carry a broken chain, and shall afford effective protection to all employees.

(b) Return strands of all conveyors that are within 7 feet of the floor and subject to contact by employees shall be provided with a trough guard.

(c) Return strands of conveyors higher than 7 feet and located over or near passageways or work areas shall have rollers or guards underneath that effectively protect employees.

(d) When the working strands of conveyors cross within 3 feet of the floor level in passageways, they shall be completely enclosed or bridged over along the full length of the exposure.

(e) Elevated slab or wood conveyors shall have sidewalls of ample height to prevent material being thrown from the conveyor. In lieu of this, the area under the conveyor may be fenced off.

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.