California Code of Regulations
Title 8 - Industrial Relations
Division 1 - Department of Industrial Relations
Chapter 4 - Division of Industrial Safety
Subchapter 13 - Logging and Sawmill Safety Orders
Article 11 - Helicopter Yarding Operations
Section 6325 - Fueling and Fueling Area

Universal Citation: 8 CA Code of Regs 6325

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) Fueling pads shall be built and maintained with a well compacted surface free of loose materials and debris.

(b) There shall be two 60:B.C. rated fire extinguishers, or equivalent fire fighting protection, readily available at each fueling station.

(c) Smoking, open flames, or other sources of ignition shall not be permitted within 50 feet of fueling operations or fuel storage areas.

(d) The helicopter engines shall be shut off if refueling with either aviation gasoline or Jet B (turbine) type fuel.

(e) The helicopter and fuel supply system shall be securely bonded together before and during fueling operations to provide static electrical discharge.

(f) The helicopter's fuel supply shall at all times be adequate to perform its mission and at least 15 minutes of additional flight time.

1. Amendment of subsection (d) filed 2-6-85; effective thirtieth day thereafter (Register 85, No. 6).
2. Amendment of subsection (e) filed 10-18-2012; operative 11-17-2012 (Register 2012, No. 42).

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.