California Code of Regulations
Title 25 - Housing and Community Development
Division 1 - Housing and Community Development
Chapter 2 - Mobilehome Parks and Installations
Article 5 - Plumbing Requirements
Section 1262 - Vent Location and Support
All vent pipes in outdoor locations shall be located at least ten (10) feet from an adjoining property line and shall extend at least ten (10) feet above ground level. All vent pipes shall be supported by at least the equivalent of a four (4) inch by four (4) inch nominal dimension redwood post securely anchored in the ground. One-piece galvanized iron vent pipes may be self-supporting if securely anchored at their base in concrete at least twelve (12) inches in depth and extending a minimum four (4) inches out from the pipe.
1. Amendment of section heading and section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).
Note: Authority cited: Section 18300, Health and Safety Code. Reference: Section 18630, Health and Safety Code.