California Code of Regulations
Title 25 - Housing and Community Development
Division 1 - Housing and Community Development
Chapter 2 - Mobilehome Parks and Installations
Article 3 - Electrical Requirements
Section 1154 - Primary System Grounding-600 Volts or Less
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
(a) When the park electrical service is supplied by a grounded system operated at 600 volts or less, an equipment grounding conductor shall be run with the feeders of the park primary electrical system to all equipment supplied by the primary electrical system.
(b) Park primary electrical systems within the park operated at 600 volts or less supplied by an ungrounded system shall not be grounded.
1. Amendment of section heading and section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).
Note: Authority cited: Section 18300, Health and Safety Code. Reference: Section 18670, Health and Safety Code.