California Code of Regulations
Title 25 - Housing and Community Development
Division 1 - Housing and Community Development
Chapter 2.2 - Special Occupancy Parks
Article 3 - Electrical Requirements
Section 2163 - Grounding of Units

Universal Citation: 25 CA Code of Regs 2163
Current through Register 2024 Notice Reg. No. 38, September 20, 2024

All exposed, noncurrent-carrying metal parts of a unit, when connected to the lot service equipment, shall be grounded by means of a grounding conductor run with the circuit conductors or in a listed power supply cord provided with an approved polarized multi-prong plug. One prong of the plug shall be for the sole purpose of connecting that grounding conductor, by means of a listed and approved grounding receptacle, to the grounded terminal at the lot service. The conductor shall be insulated and identified by a green color.

1. New section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).

Note: Authority cited: Section 18865, Health and Safety Code. Reference: Sections 18871 and 18873.3, Health and Safety Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.