TEST REQUIREMENTS FOR INTERIOR FLAME-RETARDANT CHEMICALS (WHEN APPLIED TO MATERIALS OTHER THAN FABRICS)
Section 1264.2 - Bast and Leaf Fibrous Decorative Materials

Universal Citation: 19 CA Code of Regs 1264.2
Current through Register 2024 Notice Reg. No. 38, September 20, 2024

The fire-resistance test shall be performed at the completion of the thirty-day aging period, and shall be conducted as nearly as practical as described in Section 1237.1. Tests shall be made on several different areas of the treated materials. There shall be no spread of flame from the area in contact with the test flame, and any afterflaming shall not exceed 10 seconds.

1. New section filed 9-1-50; effective thirtieth day thereafter (Register 21, No. 5).
2. Repealer of Section 1264.2 and renumbering and amendment of Section 1264.3 to 1264.2 filed 11-10-60; effective thirtieth day thereafter (Register 60, No. 23).

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.