TEST REQUIREMENTS FOR EXTERIOR FLAME-RETARDANT CHEMICALS (WHEN APPLIED TO STANDARD TEST FABRIC)
Section 1237.2 - Fire Resistance
Universal Citation: 19 CA Code of Regs 1237.2
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
(Large Scale Test). The treated fabric, both before and after water extraction, shall be tested in accordance with the method outlined in Section 1237.3 below, and shall not continue to flame for more than two (2) seconds after the burner is removed. The vertical spread of flame and afterglow (smoldering combustion), as indicated by the length of char above the tip of the test flame, shall not exceed ten inches (10").
1. New section filed 11-10-60; effective thirtieth day thereafter (Register 60, No. 23).
Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.