California Code of Regulations
Title 19 - Public Safety
Division 1 - State Fire Marshal
Chapter 6 - Fireworks
Article 6 - Classification of Fireworks
Section 986.6 - Specifications for Safe and Sane Fireworks
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
The provisions of this section shall apply to all handle goods, stick, dowel, spike and California candle fireworks having a stick dowel or inside diameter greater than 1/8 inch and other devices as noted.
Handle goods are exempt from compliance with the provisions of subsections (a), (d) and (e) of this section if they incorporate all of the following features:
(1) a soft, crushable type paper tube,
(2) an inside diameter of 3/8 inch or less,
(3) 3 inches or less of combustible chemical composition, and having an overall length not exceeding 12 inches without any choke or other muzzle restriction.
The chemical composition tubes in all fireworks items shall be sealed in a manner that prevents leakage of the pyrotechnic composition during shipping, handling, or normal operation and shall be constructed in a manner to allow functioning without burnout or blowout.
Spikes and dowels shall be inserted into the chemical composition tubes a minimum distance not less than 25% of the length of tubes 6 inches or less in length and not less than 2 inches into tubes over 6 inches long. They shall be cemented firmly in place against the clay base. There shall be no void space within the chemical composition tube.
Spikes provided with fireworks devices shall protrude at least 2 inches from the base of the device and shall have a blunt tip not less than 1/8 inch in diameter or 1/8 inch square.
Fuses on all items shall burn for not less than 3 seconds but not more than 6 seconds.
Fuses on all items shall be treated or coated in such a manner as to reduce the possibility of side ignition. The fuse on devices such as "ground spinners" that require a restricted orifice for proper thrust and contain less than 6 grams of pyrotechnic composition are exempt from this requirement.
Fireworks items sold or offered for sale at retail which are not enclosed in sealed packages, shall have their fuses or other igniting means covered in a manner approved by the State Fire Marshal to provide reasonable protection from unintentional ignition.
The base or bottom of fireworks devices having a base or fireworks devices that operate in a standing upright position shall have the minimum horizontal dimensions or the diameter of the base equal to at least one-third ( 1/3) of the height of the device including any base or cap affixed thereto.
Drivers shall be securely attached to the device so that they will not come loose in transportation, handling, and normal operation. Wheel devices intended to operate in a fixed location shall be designed in such a manner that the axle remains attached to the device during normal operation.
1. Amendment of subsections (e) and (f) filed 11-4-77; effective thirtieth day thereafter (Register 77, No. 45)
2. Amendment of section heading, subsections (a), (c) and (f)-(h) and new NOTE filed 4-14-92; operative 5-14-92 (Register 92, No. 21).
Note: Authority cited: Sections 12552 and 12553, Health and Safety Code. Reference: Sections 12560- 12569 and 12671, Health and Safety Code; and Section 1507.4, 16 Code of Federal Regulations.