California Code of Regulations
Title 19 - Public Safety
Division 1 - State Fire Marshal
Chapter 6 - Fireworks
Article 15 - Public Display
Section 999 - Mortars, Aerial Shells
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
(a) General.
(b) Steel Mortars.
Shell Size | Inside Length | ||
1.99 inches or less | 8 inches | ||
2 inches | 13 inches | ||
2 1/2 inches | 13 inches | ||
3 inches | 15 inches | ||
4 inches | 20 inches | ||
5 inches | 25 inches | ||
6 inches | 30 inches | ||
7 inches | 32 inches | ||
8 inches | 32 inches | ||
10 inches | 40 inches | ||
12 inches | 40 inches | ||
16 inches | 64 inches | ||
24 inches | 96 inches |
(c) Paper Mortars.
Shell Size | Wall Thickness | Inside Length | Base Plug * | |||
Less than | ||||||
2 inches | 1/8 inch | 8 inches | 1 inch | |||
2 inches | 1/4 inch | 13 inches | 2 inches | |||
2 1/2 inches | 3/8 inch | 13 inches | 3 inches | |||
3 inches | 3/8 inch | 15 inches | 3 inches | |||
4 inches | 1/2 inch | 20 inches | 3 inches | |||
5 inches | 1/2 inch | 25 inches | 4 inches | |||
6 inches | 1/2 inch | 30 inches | 4 inches | |||
7 inches | 3/4 inch | 32 inches | 4 inches | |||
8 inches | 3/4 inch | 32 inches | 4 inches |
* Sizes for base plugs are nominal.
(d) HDPE Mortars. High Density Polyethylene (HDPE) mortars shall meet the minimum specifications set forth below:
Shell Size | Wall Thickness | Inside Length | Base Plug * | |||
Less than 2" | 1/8 inch | 10 inches | 1 inch | |||
2 inches | 1/4 inch | 13 inches | 2 inches | |||
2 1/2 inches | 1/4 inch | 13 inches | 3 inches | |||
3 inches | 1/4 inch | 15 inches | 3 inches | |||
4 inches | 1/4 inch | 20 inches | 3 inches | |||
5 inches | 1/4 inch | 25 inches | 4 inches | |||
6 inches | 3/8 inch | 30 inches | 4 inches | |||
7 inches | 3/8 inch | 32 inches | 4 inches | |||
8 inches | 3/8 inch | 32 inches | 6 inches |
* Base plug sizes are nominal.
HDPE Mortars shall not be reloaded for a period of at least one (1) hour after use. All base plugs for HDPE mortars shall be wooden, and securely glued, as well as nailed, screwed, or bolted to the base of the mortar. Base plugs shall be discarded and replaced when damaged. Minor cracks and checks are acceptable.
(e) Other Materials. Recognizing that new materials for the construction of mortars may be developed, such materials may be used when specifically approved by the State Fire Marshal. Persons wishing to use material not specifically covered in this section shall submit the material in an amount sufficient for testing to the State Fire Marshal for determination of its safety and its inclusion in this section.
NOTE: For illustrations of typical mortar racks, troughs and drums, see Diagrams A, B and C following section 1002.
1. Repealer of former section 999 and new section filed 6-26-91 as an emergency; operative 6-26-91 (Register 91, No. 48). A Certificate of Compliance must be transmitted to OAL by 10-24-91 or emergency language will be repealed by operation of law on the following day.
2. Emergency language repealed by operation of law. Repealer of former section 999 and new section filed 4-14-92; operative 5-14-92 (Register 92, No. 21).
Note: Authority cited: Section 12552, Health and Safety Code. Reference: Section 12552, Health and Safety Code.