Section 3.17 - Guards for Heating Appliances
Current through Register 2024 Notice Reg. No. 38, September 20, 2024
Every heating appliance in any occupancy governed by these regulations which does not have protective features incorporated in its design, shall be provided with guards that will provide protection against ignition of clothing and other combustible material.
(a) Appliances employing open flame radiated heat shall have fixed and substantially constructed metallic guards located not less than 10 inches (254mm) from the radiating flame and the guard members shall be spaced not more than 2 inches (50.80mm) apart.
(b) Cabinet type appliances that are not provided with an inner combustion chamber and an air circulating space between the combustion chamber and the outer shell, shall have fixed and substantially constructed metallic guards located not less than 3 inches (76.20mm) from the shell and spaced not more than 2 inches (50.80mm) apart.