Current through Register 2024 Notice Reg. No. 38, September 20, 2024
(a) For the
purposes of this article, the following definitions apply:
(1) "Alternative Chemistries" means the
substitution of a fluorinated gas in the chamber cleaning or etching process to
increase utilization efficiency and reduce the carbon dioxide equivalent
emissions.
(2) "Calendar Year"
means the time period from January 1 through December 31.
(3) "Carbon Dioxide Equivalent" or
"CO2e" means a measure for comparing carbon dioxide with
other greenhouse gases, based on the quantity of those gases multiplied by the
appropriate global warming potential (GWP) factor.
(4) "CO2e Emissions
Limit" means the maximum allowable kilograms of CO2e
emissions per square centimeter of wafers processed in a calendar
year.
(5) "Chamber Cleaning" means
the process of using fluorinated gases to remove excess materials from chemical
vapor deposition chamber walls to prevent contamination of wafers to be
processed.
(6) "Chemical Vapor
Deposition (CVD)" means deposition of thin films on wafers by placing the
wafers in a mixture of gases, including nitrogen or another gas used as a
carrier, which react at the surface of the wafers.
(7) "Equipment" means any article, machine,
or other contrivance, or combination thereof, which may cause the issuance or
control the issuance of fluorinated gas emissions in etching or CVD chamber
cleaning processes.
(8) "Etching"
means a chemical reactive process for selectively removing material on a wafer
using fluorinated, ionized gases.
(9) "Fluorinated Gases" means a compound that
contains fluorine and exists in a gaseous state at 25 degrees Celsius and 1
atmosphere of pressure. Fluorinated gases include, but are not limited to:
(A) hexafluoroethane
(C2F6),
(B) octafluoropropane
(C3F8),
(C) octafluorocyclopentene
(C5F8),
(D) tetrafluoromethane
(CF4),
(E)
trifluoromethane (CHF3),
(F) difluoromethane
(CH2F2),
(G) octafluorocyclobutane
(c-C4F8),
(H) octafluorotetrahydrofuran
(C4F8O),
(I) hexafluoro-1,3-butadiene
(C4F6),
(J) carbon fluoride oxide
(COF2),
(K)
nitrogen trifluoride (NF3), and
(L) sulfur hexafluoride
(SF6).
(10) "Global Warming Potential (GWP)" means
the radiative forcing impact of one mass-based unit of a given greenhouse gas
relative to an equivalent unit of carbon dioxide over a given period of
time.
(11) "Global Warming
Potential Value" or "GWP Value" means the global warming potential value of a
chemical or compound as specified in the IPCC: 1996 Second Assessment Report
(SAR), Table 2.14, in Climate Change 2007: The Physical Sciences Basis,
Contribution of Working Group I to the Fourth Assessment Report of the
Intergovernmental Panel on Climate Change, which is incorporated by reference
herein.
If Table 2.14 does not contain a SAR 100-year GWP Value
for a specific chemical or compound, then the 100-year GWP Value in Table 2.14
for that chemical or compound must be used.
(12) "Heat Transfer Fluid" means a
fluorinated fluid which prevents a device, such as a semiconductor, from
overheating by removing excess heat produced during a manufacturing
process.
(13) "Permitting Agency"
means any air pollution control district or air quality management
district.
(14) "Process
Optimization" means the practice of using end-point detectors and/or process
parameter variation to achieve optimum gas usage to reduce excess fluorinated
gas emissions.
(15) "Semiconductor
Operation" means an operation performed to process semiconductor devices or
related solid state devices. It may include, but is not limited to, the
processing of diodes, zeners, stacks, rectifiers, integrated microcircuits,
transistors, solar cells, light-sensing devices, and light-emitting
devices.
(16) "Wafer" means a thin,
usually round, slice of a material from which integrated circuits, or chips,
are made.
(17) "Wafer Surface Area"
means the entire surface area of one side of a wafer, or multiple wafers, and
includes wafers that do not pass owner or operator
inspection.
1. New
section filed 12-14-2009; operative 1-1-2010 pursuant to Government Code
section
11343.4
(Register 2009, No. 51).
Note: Authority cited: Sections
38501,
38510,
38560,
38560.5,
38580,
39600
and
39601,
Health and Safety Code. Reference: Sections
38501,
38505,
38510,
38550,
38551,
38560,
38560.5,
39600
and
39601,