California Code of Regulations
Title 14 - Natural Resources
Division 2 - Department of Conservation
Chapter 4 - Development, Regulation, and Conservation of Oil and Gas Resources
Subchapter 4 - State-Wide Geothermal Regulations
Article 8 - Plugging and Abandonment
Section 1981.1 - Exploratory Well Requirements (NO Production Casing)

Universal Citation: 14 CA Code of Regs 1981.1

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) Base of fresh waters--a minimum of 30 meters (about 100 feet) of cement straddling the interface or transition zone whether behind casing or uncased.

(b) Shoe plug (all casing, including conductor pipe)--straddle with 30 meters (about 100 feet) of cement.

(c) Where the well has been drilled with air, a bridge plug shall be placed at the shoe of the surface casing and the bridge plug shall be capped with at least 60 meters (about 200 feet) of cement.

(d) Surface plug--15 meters (about 50 feet) minimum. May be either neat cement or concrete mix.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.