California Code of Regulations
Title 14 - Natural Resources
Division 2 - Department of Conservation
Chapter 4 - Development, Regulation, and Conservation of Oil and Gas Resources
Subchapter 1 - Onshore Well Regulations
Article 5 - Requirements for Underground Gas Storage Projects
Section 1726.4.2 - Evaluation of Wells Within the Area of Review

Universal Citation: 14 CA Code of Regs 1726.4.2

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

(a) The following requirements apply, at minimum and subject to augmentation by the Division as the Division deems appropriate on a project-specific basis, to ensure that wells within the area of review will not be a potential conduit for fluid migration outside the approved gas storage zone:

(1) All wells within the area of review and that are in the same or a deeper zone as the gas storage reservoir, including directionally drilled wells that intersect the area of review in the same or deeper zone, shall be evaluated for the potential to allow fluid to migrate outside of the approved zone of gas storage. The operator should identify, and the Division confirm, wells which may require integrity testing or well logging in order to provide the requisite assurances that such wells will not act as conduits for fluid migration.

(2) Plugged and abandoned wells within the area of review shall have cement across all perforations and extending at least 100 feet above the highest of the top of a landed liner, the uppermost perforations, the casing cementing point, the water shutoff holes, or the approved gas storage zone. The Division may select plugged and abandoned wells to be re-entered, examined, re-plugged and abandoned, or monitored to manage identified containment assurance issues.

(3) If a plugged and abandoned well within the area of review does not meet the cement specifications of subdivision (a)(2), the Division may approve an alternative demonstration that the well will not be a potential conduit for fluid migration outside the approved gas storage zone. The Division's approval of such an alternative demonstration shall be supported by written findings by the Division that identify each plugged and abandoned well in the area of review that does not meet the cement specifications of subdivision (a)(2), specify how the well does not meet the requirements of subdivision (a)(2), and identify the basis for the Division's approval of the alternative demonstration.

1. New section filed 6-28-2018; operative 10-1-2018 (Register 2018, No. 26).

Note: Authority cited: Sections 3013, 3106 and 3180, Public Resources Code. Reference: Sections 3106, 3180, 3181, 3220 and 3403.5, Public Resources Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.