California Code of Regulations
Title 13 - Motor Vehicles
Division 2 - Department of the California Highway Patrol
Chapter 2 - Lighting Equipment
Article 11 - Deceleration Signal Lamp Systems
Section 734 - Temperature Test Requirements

Universal Citation: 13 CA Code of Regs 734

Current through Register 2024 Notice Reg. No. 38, September 20, 2024

The control system shall meet the following requirements at both 11 V and 15 V:

(a) Low Temperature Test. The control system shall be placed in its normal operating position in a circulating air cabinet at -32 ± 3° C (-25 ± 5° F) for 2 h. At the end of that period and while still at that temperature, the unit shall meet the requirements in Table I at 0 g and 0.3 g.

(b) High Temperature Test. The control system shall be placed in its normal operating position in a circulating air cabinet at 74 + 0, -2.8° C (165 + 0, -5° F) for 2 h. At the end of that period and while still at that temperature, the unit shall meet the requirements in Table I at 0 g and 0.3 g.

Note: Authority cited: Section 26103, Vehicle Code. Reference: Sections 24012 and 26103, Vehicle Code.

Disclaimer: These regulations may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.