Arizona Administrative Code
Title 9 - HEALTH SERVICES
Chapter 7 - DEPARTMENT OF HEALTH SERVICES - RADIATION CONTROL
Article 17 - WIRELINE SERVICE OPERATIONS AND SUBSURFACE TRACER STUDIES
Section R9-7-1714 - Radiation Survey Instruments
Current through Register Vol. 30, No. 38, September 20, 2024
A. A licensee shall maintain at each field station and temporary job site a calibrated and operable radiation survey instrument capable of detecting beta and gamma radiation. The licensee shall ensure that the radiation survey instrument is capable of measuring 1.0 microsievert (0.1 millirem) per hour through 500 microsievert (50 millirem) per hour.
B. A licensee shall ensure that additional calibrated and operable radiation detection instruments are available as needed and that the instruments are sensitive enough to detect the low radiation and contamination levels that could be encountered if a sealed source is ruptured.
C. A licensee shall ensure that the radiation survey instrument required in subsection (A) is calibrated
D. A licensee shall retain calibration records for a period of three years from the date of calibration.