A manufacturer of FBBs shall prepare a compliance assurance manual that has all of the following:

1. An 8 1/2 X 11 inch format with page numbers and revision traceability;

2. The manufacturer's name and address of the factory to which the manual applies;

3. A table of contents that identifies key elements in the quality and compliance control process;

4. An organizational chart that shows titles and functions of all positions responsible for any aspect of quality and compliance control;

5. A description of the design-document control process and procedures for ensuring the current approved design package or building plans are available to production, quality, and compliance personnel;

6. A description of procedures for handling materials, including treatment and disposal of rejected materials, in compliance with standards;

7. A description of the FBB-identification system including a unique identifier, such as a serial or identification number, that is permanently affixed to each module or panel of the FBB at the beginning of manufacturing and where the unique identifier is located on the FBB;

8. A drawing showing the layout of the factory and location of the work area for each step in the manufacturing sequence with a description of the scope of work performed at each work area, including off-line processes;

9. An inspection checklist, keyed to the drawing required in subsection (8), that identifies the inspections and tests to be performed at each step in the manufacturing sequence and title of the position responsible for ensuring inspections and tests are performed;

10. A list that includes step-by-step procedures for ensuring all required tests are performed, the equipment needed to perform each test, and procedures for maintaining test equipment;

11. A description of procedures for maintaining control of certificates, installing certificates on FBBs, and making the monthly report of certificates and title of the position responsible for ensuring these tasks are performed;

12. A description of the procedures for storing completed FBBs at the facility including the manner in which stored FBBs are protected from the elements and other sources of potential damage; and

13. A description of procedures for ensuring building documents are retained and title of the position responsible for ensuring document retention.

Disclaimer: These regulations may not be the most recent version. Arizona may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.