8 AAC 78.070 - Electrical safety requirements

Universal Citation: 8 AK Admin Code 78.070

Current through August 30, 2024

(a) An amusement ride's electrical equipment must conform to the National Electrical Codeand National Electrical Safety Codestandards adopted by reference in 8 AAC 70.025.

(b) Each electrical transformer substation and electrical distribution box must be completely enclosed and locked.

(c) Except as provided in (e) of this section, each amusement ride must have a listed or labeled disconnect switch within reach of the attendant.

(d) A momentary contact or "deadman" switch that controls the operation of the ride is required on each ride except a ride that is solely passenger operated. A momentary contact or "deadman" switch may not be overridden.

(e) For arcade-type amusement rides, the operator may comply with (c) of this section by using a central disconnect switch that shuts off power to all amusement rides. The central disconnect switch must be visible from each amusement ride and must be supervised by an attendant when an amusement ride is operating.

(f) Notwithstanding (a) of this section, protective mats required by Article 525 of the edition of the National Electrical Codeadopted by reference in 8 AAC 70.025 must be used for any set-up over five days' duration.

Authority:AS 05.20.070

Disclaimer: These regulations may not be the most recent version. Alaska may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.