National Emission Standards for Hazardous Air Pollutants: Surface Coating of Metal Cans and Surface Coating of Metal Coil Residual Risk and Technology Reviews, 10828-10871 [2020-00303]
Download as PDF
10828
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
ENVIRONMENTAL PROTECTION
AGENCY
40 CFR Part 63
[EPA–HQ–OAR–2017–0684, EPA–HQ–OAR–
2017–0685; FRL–10003–81–OAR]
RIN 2060–AT51
National Emission Standards for
Hazardous Air Pollutants: Surface
Coating of Metal Cans and Surface
Coating of Metal Coil Residual Risk
and Technology Reviews
Environmental Protection
Agency (EPA).
ACTION: Final rule.
AGENCY:
The U.S. Environmental
Protection Agency (EPA) is taking final
action on the residual risk and
technology reviews (RTRs) conducted
for the Surface Coating of Metal Cans
and Surface Coating of Metal Coil
source categories regulated under
national emission standards for
hazardous air pollutants (NESHAP). The
EPA is also taking final action on
amendments for the two source
categories to address emissions during
periods of startup, shutdown, and
malfunction (SSM); electronic reporting
of performance test results and
compliance reports; the addition of EPA
Method 18 and updates to several
measurement methods; and the addition
of requirements for periodic
performance testing. Additionally,
several miscellaneous technical
amendments are being made to improve
the clarity of the rule requirements. We
are making no revisions to the
numerical emission limits for the two
source categories based on the residual
risk and technology reviews.
DATES: This final rule is effective on
February 25, 2020. The incorporation by
reference (IBR) of certain publications
listed in the rule is approved by the
Director of the Federal Register as of
February 25, 2020.
ADDRESSES: The EPA has established
dockets for this action under Docket ID
No. EPA–HQ–OAR–2017–0684 for 40
Code of Federal Regulations (CFR) part
63, subpart KKKK, Surface Coating of
Metal Cans, and Docket ID No. EPA–
HQ–OAR–2017–0685 for 40 CFR part
63, subpart SSSS, Surface Coating of
Metal Coil. All documents in the docket
are listed on the https://
www.regulations.gov/ website. Although
listed, some information is not publicly
available, e.g., confidential business
information (CBI) or other information
whose disclosure is restricted by statute.
Certain other material, such as
copyrighted material, is not placed on
jbell on DSKJLSW7X2PROD with RULES2
SUMMARY:
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
the internet and will be publicly
available only in hard copy form.
Publicly available docket materials are
available either electronically through
https://www.regulations.gov/, or in hard
copy at the EPA Docket Center, WJC
West Building, Room Number 3334,
1301 Constitution Ave. NW,
Washington, DC. The Public Reading
Room hours of operation are 8:30 a.m.
to 4:30 p.m. Eastern Standard Time
(EST), Monday through Friday. The
telephone number for the Public
Reading Room is (202) 566–1744, and
the telephone number for the EPA
Docket Center is (202) 566–1742.
FOR FURTHER INFORMATION CONTACT: For
questions about this final action, contact
Ms. Paula Hirtz, Minerals and
Manufacturing Group, Sector Policies
and Programs Division (D243–04),
Office of Air Quality Planning and
Standards, U.S. Environmental
Protection Agency, Research Triangle
Park, North Carolina 27711; telephone
number: (919) 541–2618; fax number:
(919) 541–4991; and email address:
hirtz.paula@epa.gov. For specific
information regarding the risk modeling
methodology, contact Mr. Chris
Sarsony, Health and Environmental
Impacts Division (C539–02), Office of
Air Quality Planning and Standards,
U.S. Environmental Protection Agency,
Research Triangle Park, North Carolina
27711; telephone number: (919) 541–
4843; fax number: (919) 541–0840; and
email address: sarsony.chris@epa.gov.
For information about the applicability
of these NESHAP to a particular entity,
contact Mr. John Cox, Office of
Enforcement and Compliance
Assurance, U.S. Environmental
Protection Agency, WJC South Building
(Mail Code 2227A), 1200 Pennsylvania
Avenue NW, Washington, DC 20460;
telephone number: (202) 564–1395; and
email address: cox.john@epa.gov.
SUPPLEMENTARY INFORMATION:
Preamble acronyms and
abbreviations. We use multiple
acronyms and terms in this preamble.
While this list may not be exhaustive, to
ease the reading of this preamble and for
reference purposes, the EPA defines the
following terms and acronyms here:
ASTM American Society for Testing and
Materials
BPA bisphenol A
BPA–NI not intentionally containing BPA
CAA Clean Air Act
CBI Confidential Business Information
CDX Central Data Exchange
CEDRI Compliance and Emissions Data
Reporting Interface
CEMS continuous emissions monitoring
systems
CFR Code of Federal Regulations
DGME diethylene glycol monobutyl ether
PO 00000
Frm 00002
Fmt 4701
Sfmt 4700
EPA Environmental Protection Agency
ERT Electronic Reporting Tool
HAP hazardous air pollutant(s)
HCl hydrochloric acid
HF hydrogen fluoride
HI hazard index
HQ hazard quotient
HQREL hazard quotient recommended
exposure limit
IBR incorporation by reference
ICR Information Collection Request
kg kilogram
km kilometer
MACT maximum achievable control
technology
MIR maximum individual risk
NAAQS National Ambient Air Quality
Standards
NAICS North American Industry
Classification System
NESHAP national emission standards for
hazardous air pollutants
NSPS new source performance standard
NSR New Source Review
NTTAA National Technology Transfer and
Advancement Act
OAQPS Office of Air Quality Planning and
Standards
OMB Office of Management and Budget
OSHA Occupational Safety and Health
Administration
PB–HAP hazardous air pollutants known to
be persistent and bio-accumulative in the
environment
PDF portable document format
PRA Paperwork Reduction Act
PTE permanent total enclosure
REL reference exposure level
RFA Regulatory Flexibility Act
RTR residual risk and technology review
SSM startup, shutdown, and malfunction
TOSHI target organ-specific hazard index
tpy tons per year
mg/m3 micrograms per cubic meter
UMRA Unfunded Mandates Reform Act
VCS voluntary consensus standards
Background information. On June 4,
2019, the EPA proposed revisions to the
Surface Coating of Metal Cans NESHAP
and the Surface Coating of Metal Coil
NESHAP based on our RTRs. In this
action, we are finalizing decisions and
revisions to the rules. In this preamble,
we summarize some of the more
significant comments we timely
received regarding the proposed rule
and provide our responses. A summary
of all the public comments on the
proposed rules and the EPA’s responses
to those comments is available in the
‘‘Summary of Public Comments and
Responses for the Risk and Technology
Reviews for the Surface Coating of Metal
Cans and the Surface Coating of Metal
Coil NESHAP,’’ in Docket ID Nos. EPA–
HQ–OAR–2017–0684 and EPA–HQ–
OAR–2017–0685. A ‘‘track changes’’
version of the regulatory language that
incorporates the changes in this action
is available in the docket for each rule.
Organization of this document. The
information in this preamble is
organized as follows:
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
I. General Information
A. Does this action apply to me?
B. Where can I get a copy of this document
and other related information?
C. Judicial Review and Administrative
Reconsideration
II. Background
A. What is the statutory authority for this
action?
B. What are the source categories and how
does the NESHAP regulate HAP
emissions from the source categories?
C. What changes did we propose for the
source categories in our June 4, 2019,
RTR proposal?
III. What is included in these final rules?
A. What are the final rule amendments
based on the risk reviews for the Surface
Coating of Metal Cans and Surface
Coating of Metal Coil source categories?
B. What are the final rule amendments
based on the technology reviews for the
Surface Coating of Metal Cans and
Surface Coating of Metal Coil source
categories?
C. What are the final rule amendments
addressing emissions during periods of
SSM?
D. What other changes have been made to
the NESHAP?
E. What are the effective and compliance
dates of the revisions to the standards?
F. What are the requirements for
submission of performance test data to
the EPA?
IV. What is the rationale for our final
decisions and amendments for the
Surface Coating of Metal Cans and
Surface Coating of Metal Coil source
categories?
A. Residual Risk Reviews
B. Technology Reviews
C. Electronic Reporting Provisions
D. SSM Provisions
E. Ongoing Compliance Demonstrations
V. Summary of Cost, Environmental, and
Economic Impacts and Additional
Analyses Conducted
A. What are the affected sources?
B. What are the air quality impacts?
C. What are the cost impacts?
D. What are the economic impacts?
E. What are the benefits?
F. What analysis of environmental justice
did we conduct?
G. What analysis of children’s
environmental health did we conduct?
VI. Statutory and Executive Order Reviews
A. Executive Order 12866: Regulatory
Planning and Review and Executive
Order 13563: Improving Regulation and
Regulatory Review
B. Executive Order 13771: Reducing
Regulations and Controlling Regulatory
Costs
10829
C. Paperwork Reduction Act (PRA)
D. Regulatory Flexibility Act (RFA)
E. Unfunded Mandates Reform Act
(UMRA)
F. Executive Order 13132: Federalism
G. Executive Order 13175: Consultation
and Coordination With Indian Tribal
Governments
H. Executive Order 13045: Protection of
Children From Environmental Health
Risks and Safety Risks
I. Executive Order 13211: Actions
Concerning Regulations That
Significantly Affect Energy Supply,
Distribution, or Use
J. National Technology Transfer and
Advancement Act (NTTAA) and 1 CFR
Part 51
K. Executive Order 12898: Federal Actions
To Address Environmental Justice in
Minority Populations and Low-Income
Populations
L. Congressional Review Act (CRA)
I. General Information
A. Does this action apply to me?
Regulated entities. Categories and
entities potentially regulated by this
action are shown in Table 1 of this
preamble.
TABLE 1—NESHAP AND INDUSTRIAL SOURCE CATEGORIES AFFECTED BY THIS FINAL ACTION
NAICS 1
code
NESHAP source category
Surface Coating of Metal Cans ...................
332431
332115
332116
332812
332999
332431
332812
325992
326199
331110
331221
331315
331318
331420
332311
332312
332322
3 332812
Surface Coating of Metal Coil .....................
332999
333249
337920
Regulated entities 2
Two-piece Beverage Can Facilities, Three-piece Food Can Facilities, Two-piece Draw
and Iron Facilities, One-piece Aerosol Can Facilities.
Can Assembly Facilities.
End Manufacturing Facilities.
Photographic Film, Paper, Plate, and Chemical Manufacturing.
All Other Plastics Product Manufacturing.
Iron and Steel Mills and Ferroalloy Manufacturing.
Rolled Steel Shape Manufacturing.
Aluminum Sheet, Plate, and Foil Manufacturing.
Other Aluminum Rolling, Drawing, and Extruding.
Copper Rolling, Drawing, Extruding, and Alloying.
Prefabricated Metal Building and Component Manufacturing.
Fabricated Structural Metal Manufacturing.
Sheet Metal Work Manufacturing.
Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers.
All Other Miscellaneous Fabricated Metal Product Manufacturing.
Other Industrial Machinery Manufacturing.
Blind and Shade Manufacturing.
1 North
American Industry Classification System.
entities are major source facilities that apply surface coatings to these parts or products.
3 The majority of coil coating facilities are included in NAICS Code 332812.
jbell on DSKJLSW7X2PROD with RULES2
2 Regulated
Table 1 of this preamble is not
intended to be exhaustive, but rather to
provide a guide for readers regarding
entities likely to be affected by the final
action for the source categories listed.
To determine whether your facility is
affected, you should examine the
applicability criteria in the appropriate
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
NESHAP. If you have any questions
regarding the applicability of any aspect
of these NESHAP, please contact the
appropriate person listed in the
preceding FOR FURTHER INFORMATION
CONTACT section of this preamble.
PO 00000
Frm 00003
Fmt 4701
Sfmt 4700
B. Where can I get a copy of this
document and other related
information?
In addition to being available in the
dockets, an electronic copy of this final
action will also be available on the
internet. Following signature by the
EPA Administrator, the EPA will post
E:\FR\FM\25FER2.SGM
25FER2
10830
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
copies of this final action at: https://
www.epa.gov/stationary-sources-airpollution/surface-coating-metal-cansnational-emission-standards-hazardous
and https://www.epa.gov/stationarysources-air-pollution/surface-coatingmetal-coil-national-emission-standardshazardous. Following publication in the
Federal Register, the EPA will post the
Federal Register version and key
technical documents at these same
websites.
Additional information is available on
the RTR website at https://
www.epa.gov/stationary-sources-airpollution/risk-and-technology-reviewnational-emissions-standardshazardous. This information includes
an overview of the RTR program, links
to project websites for the RTR source
categories, and detailed emissions data
and other data we used as inputs to the
risk assessments.
jbell on DSKJLSW7X2PROD with RULES2
C. Judicial Review and Administrative
Reconsideration
Under Clean Air Act (CAA) section
307(b)(1), judicial review of this final
action is available only by filing a
petition for review in the United States
Court of Appeals for the District of
Columbia Circuit (the Court) by April
27, 2020. Under CAA section 307(b)(2),
the requirements established by these
final rules may not be challenged
separately in any civil or criminal
proceedings brought by the EPA to
enforce the requirements.
Section 307(d)(7)(B) of the CAA
further provides that only an objection
to a rule or procedure which was raised
with reasonable specificity during the
period for public comment (including
any public hearing) may be raised
during judicial review. This section also
provides a mechanism for the EPA to
reconsider the rule if the person raising
an objection can demonstrate to the
Administrator that it was impracticable
to raise such objection within the period
for public comment or if the grounds for
such objection arose after the period for
public comment (but within the time
specified for judicial review) and if such
objection is of central relevance to the
outcome of the rule. Any person seeking
to make such a demonstration should
submit a Petition for Reconsideration to
the Office of the Administrator, U.S.
EPA, Room 3000, WJC South Building,
1200 Pennsylvania Ave. NW,
Washington, DC 20460, with a copy to
both the person(s) listed in the
preceding FOR FURTHER INFORMATION
CONTACT section, and the Associate
General Counsel for the Air and
Radiation Law Office, Office of General
Counsel (Mail Code 2344A), U.S. EPA,
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
1200 Pennsylvania Ave. NW,
Washington, DC 20460.
II. Background
A. What is the statutory authority for
this action?
Section 112 of the CAA establishes a
two-stage regulatory process to address
emissions of hazardous air pollutants
(HAP) from stationary sources. In the
first stage, we must identify categories
of sources emitting one or more of the
HAP listed in CAA section 112(b) and
then promulgate technology-based
NESHAP for those sources. ‘‘Major
sources’’ are those that emit, or have the
potential to emit, any single HAP at a
rate of 10 tons per year (tpy) or more,
or 25 tpy or more of any combination of
HAP. For major sources, these standards
are commonly referred to as maximum
achievable control technology (MACT)
standards and must reflect the
maximum degree of emission reductions
of HAP achievable (after considering
cost, energy requirements, and non-air
quality health and environmental
impacts). In developing MACT
standards, CAA section 112(d)(2) directs
the EPA to consider the application of
measures, processes, methods, systems,
or techniques, including, but not limited
to, those that reduce the volume of or
eliminate HAP emissions through
process changes, substitution of
materials, or other modifications;
enclose systems or processes to
eliminate emissions; collect, capture, or
treat HAP when released from a process,
stack, storage, or fugitive emissions
point; are design, equipment, work
practice, or operational standards; or
any combination of the above.
For these MACT standards, the statute
specifies certain minimum stringency
requirements, which are referred to as
MACT floor requirements, and which
may not be based on cost
considerations. See CAA section
112(d)(3). For new sources, the MACT
floor cannot be less stringent than the
emission control achieved in practice by
the best-controlled similar source. The
MACT floor for existing sources can be
less stringent than floors for new
sources, but they cannot be less
stringent than the average emission
limitation achieved by the bestperforming 12 percent of existing
sources in the category or subcategory
(or the best-performing five sources for
categories or subcategories with fewer
than 30 sources). In developing MACT
standards, we must also consider
control options that are more stringent
than the floor under CAA section
112(d)(2). We may establish standards
more stringent than the floor, based on
PO 00000
Frm 00004
Fmt 4701
Sfmt 4700
the consideration of the cost of
achieving the emissions reductions, any
non-air quality health and
environmental impacts, and energy
requirements.
In the second stage of the regulatory
process, the CAA requires the EPA to
undertake two different analyses, which
we refer to as the technology review and
the residual risk review. Under the
technology review, we must review the
technology-based standards and revise
them ‘‘as necessary (taking into account
developments in practices, processes,
and control technologies)’’ no less
frequently than every 8 years, pursuant
to CAA section 112(d)(6). Under the
residual risk review, we must evaluate
the risk to public health remaining after
application of the technology-based
standards and revise the standards, if
necessary, to provide an ample margin
of safety to protect public health or to
prevent, taking into consideration costs,
energy, safety, and other relevant
factors, an adverse environmental effect.
The residual risk review is required
within 8 years after promulgation of the
technology-based standards, pursuant to
CAA section 112(f). In conducting the
residual risk review, if the EPA
determines that the current standards
provide an ample margin of safety to
protect public health, it is not necessary
to revise the MACT standards pursuant
to CAA section 112(f).1 For more
information on the statutory authority
for this rule, see the proposal preamble
(84 FR 25908, June 4, 2019) and the
memorandum, CAA Section 112 Risk
and Technology Reviews: Statutory
Authority and Methodology, December
14, 2017, in the Surface Coating of Metal
Cans Docket and the Surface Coating of
Metal Coil Docket.
B. What are the source categories and
how do the NESHAP regulate HAP
emissions from the source categories?
1. What is the Surface Coating of Metal
Cans source category and how does the
current NESHAP regulate its HAP
emissions?
The EPA promulgated the Surface
Coating of Metal Cans NESHAP on
November 13, 2003 (68 FR 64432). The
standards are codified at 40 CFR part 63,
subpart KKKK. The Surface Coating of
Metal Cans industry consists of facilities
that are engaged in the surface coating
of metal cans and ends (including
decorative tins) and metal crowns and
1 The Court has affirmed this approach of
implementing CAA section 112(f)(2)(A): NRDC v.
EPA, 529 F.3d 1077, 1083 (D.C. Cir. 2008) (‘‘If EPA
determines that the existing technology-based
standards provide an ‘ample margin of safety,’ then
the Agency is free to readopt those standards during
the residual risk rulemaking.’’).
E:\FR\FM\25FER2.SGM
25FER2
jbell on DSKJLSW7X2PROD with RULES2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
closures. The source category covered
by this MACT standard currently
includes five facilities.
The Surface Coating of Metal Cans
NESHAP (40 CFR 63.3561) defines a
‘‘metal can’’ as ‘‘a single-walled
container manufactured from metal
substrate equal to or thinner than 0.3785
millimeter (mm) (0.0149 inch)’’ and
includes coating operations for four
subcategories: (1) One- and two- piece
draw and iron can body coating; (2)
sheetcoating; (3) three-piece can body
assembly coating; and (4) end coating.
The Surface Coating of Metal Cans
NESHAP also defines a ‘‘coating’’ as ‘‘a
material that is applied to a substrate for
decorative, protective, or functional
purposes. Such materials include, but
are not limited to, paints, sealants,
caulks, inks, adhesives, and maskants.’’
This source category is further described
in the June 4, 2019, RTR proposal. See
84 FR 25908.
The primary HAP emitted from this
source category are organic HAP and
include glycol ethers, formaldehyde,
xylenes, toluene, methyl isobutyl
ketone, 2-(hexyloxy) ethanol, ethyl
benzene, and methanol. These HAP
account for 99 percent of the HAP
emissions from the source category. The
HAP emissions from the Surface Coating
of Metal Cans source category are
emitted from the coating materials
which include the coatings, thinners,
and cleaning materials used in the
coating operations. The coating
operations include: The equipment used
to apply the coatings; the equipment to
dry or cure the coatings after
application; all storage containers and
mixing vessels; all manual and
automated equipment and containers
used to convey the coating materials;
and all storage containers and manual
and automated equipment used for
conveying waste materials generated by
the coating operations. The coating
application lines and the drying and
curing ovens are the largest sources of
HAP emissions. The coating application
lines apply an exterior base coat to twoand three-piece cans using a
lithographic/printing (i.e., roll)
application process. The inside, side
seam, and repair coatings are spray
applied using airless spray equipment
and are a minor portion of the can
coating operations. As indicated by the
name, repair spray coatings are used to
cover breaks in the coating that are
caused during the formation of the score
in easy-open ends or to provide, after
the manufacturing process, an
additional protective layer for corrosion
resistance.
The Surface Coating of Metal Cans
NESHAP specifies numerical emission
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
limits for existing sources and for new
or reconstructed sources for organic
HAP emissions from four subcategories
of can coating operations. Within the
four subcategories are several different
types of coatings with separate emission
limits. The specific organic HAP
emission limits are provided in Tables
1 and 2 of 40 CRF part 63, subpart
KKKK.
The Surface Coating of Metal Cans
NESHAP provides that emission limits
can be achieved using several different
options, including a compliant material
option, an emission rate without add-on
controls option (averaging option), an
emission rate with add-on controls
option, or a control efficiency/outlet
concentration option. For any coating
operation(s) on which the facility uses
the compliant material option or the
emission rate without add-on controls
option, the facility is not required to
meet any work practice standards.
If the facility uses the emission rate
with add-on controls option, the facility
must develop and implement a work
practice plan to minimize organic HAP
emissions from the storage, mixing, and
conveying of coatings, thinners, and
cleaning materials used in, and waste
materials generated by, the coating
operation(s) using that option. The plan
must specify practices and procedures
to ensure that a set of minimum work
practices specified in the NESHAP are
implemented. The facility must also
comply with site-specific operating
limits for the emission capture and
control system.
2. What is the Surface Coating of Metal
Coil source category and how does the
current NESHAP regulate its HAP
emissions?
The EPA promulgated the Surface
Coating of Metal Coil source category
NESHAP on June 10, 2002 (67 FR
39794). The standards are codified at 40
CFR part 63, subpart SSSS. The Surface
Coating of Metal Coil industry consists
of facilities that operate a metal coil
coating line. The source category
covered by this MACT standard
currently includes 48 facilities.
The Surface Coating of Metal Coil
NESHAP (40 CFR 63.5110) defines a
‘‘coil coating line’’ as ‘‘a process and the
collection of equipment used to apply
an organic coating to the surface of
metal coil.’’ A coil coating line includes
a web unwind or feed section, a series
of one or more work stations, and any
associated curing oven, wet section, and
quench station. A work station is ‘‘a unit
on a coil coating line where the coating
material is deposited onto the metal coil
substrate’’ or a coating application
station. This source category is further
PO 00000
Frm 00005
Fmt 4701
Sfmt 4700
10831
described in the June 4, 2019, RTR
proposal. See 84 FR 25909.
The primary HAP emitted from metal
coil coating operations are organic HAP
and include xylenes, glycol ethers,
naphthalene, isophorone, toluene,
diethylene glycol monobutyl ether
(DGME), and ethyl benzene. The
majority of organic HAP emissions are
from the coating application stations
and the curing ovens.
The Surface Coating of Metal Coil
NESHAP specifies numerical emission
limits for organic HAP emissions from
the coating application stations and
associated curing ovens. The Surface
Coating of Metal Coil NESHAP provides
that emission limits can be achieved
using several different options: (1) Use
only individually compliant coatings
with an organic HAP content that does
not exceed 0.046 kilogram (kg)/liter of
solids applied, (2) use coatings with an
average organic HAP content that does
not exceed 0.046 kg/liter of solids on a
rolling 12-month average, (3) use a
capture system and add-on control
device to either reduce emissions by 98
percent or use a 100-percent efficient
capture system (permanent total
enclosure (PTE)) and an oxidizer to
reduce organic HAP emissions to no
more than 20 parts per million by
volume as carbon, or (4) use a
combination of compliant coatings and
control devices to maintain an average
equivalent emission rate of organic HAP
not exceeding 0.046 kg/liter of solids on
a rolling 12-month average basis. These
compliance options apply to an
individual coil coating line, to multiple
lines as a group, or to the entire affected
source.
C. What changes did we propose for the
source categories in our June 4, 2019,
RTR proposal?
On June 4, 2019, the EPA published
proposed rule amendments in the
Federal Register for the Surface Coating
of Metal Cans NESHAP, 40 CFR part 63,
subpart KKKK, and the Surface Coating
of Metal Coil NESHAP, 40 CFR part 63,
subpart SSSS, that took into
consideration the RTR analyses.
For each source category, we
proposed that the risks are acceptable,
and that additional emission controls
for each source category are not
necessary to provide an ample margin of
safety. For the technology reviews, we
did not identify any developments in
practices, processes, or control
technologies, and, therefore, we did not
propose any changes to the standards
under CAA section 112(d)(6).
We also proposed the following
amendments:
E:\FR\FM\25FER2.SGM
25FER2
10832
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
jbell on DSKJLSW7X2PROD with RULES2
• For each source category, a
requirement for electronic submittal of
notifications, semi-annual reports, and
compliance reports (which include
performance test reports);
• for each source category, revisions
to the SSM provisions of each NESHAP
in order to ensure that they are
consistent with the Court decision in
Sierra Club v. EPA, 551 F. 3d 1019 (D.C.
Cir. 2008), which vacated two
provisions that exempted source owners
and operators from the requirement to
comply with otherwise applicable CAA
section 112(d) emission standards
during periods of SSM;
• for the Surface Coating of Metal
Coil NESHAP, adding the option of
conducting EPA Method 18 of appendix
A to 40 CFR part 60, ‘‘Measurement of
Gaseous Organic Compound Emissions
by Gas Chromatography,’’ to measure
and then subtract methane emissions
from measured total gaseous organic
mass emissions as carbon;
• for the Surface Coating of Metal
Coil NESHAP, revising 40 CFR 63.5090
to clarify that the NESHAP does not
apply to the application of markings
(including letters, numbers, or symbols)
to bare metal coils that are used for
product identification or for product
inventory control;
• for each source category, removing
references to paragraph (d)(4) of the
Occupational Safety and Health
Administration’s (OSHA’s) Hazard
Communication standard (29 CFR
1910.1200), which dealt with OSHAdefined carcinogens, and replacing that
reference with a list of HAP that must
be regarded as potentially carcinogenic
based on EPA guidelines;
• for each source category, a
requirement to conduct performance
testing and reestablish operating limits
no less frequently than every 5 years for
sources that are using add-on controls to
demonstrate compliance; and
• for each source category,
Incorporation by Reference (IBR) of
alternative test methods and references
to updated alternative test methods; and
several minor editorial and technical
changes in each subpart.
III. What is included in these final
rules?
This action finalizes the EPA’s
determinations pursuant to the RTR
provisions of CAA section 112 for the
Surface Coating of Metal Cans source
category and the Surface Coating of
Metal Coil source category. This action
also finalizes other changes to the
NESHAP for each source category,
including:
• A requirement for electronic
submittal of notifications, semi-annual
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
reports, and compliance reports (which
include performance test reports);
• revisions to the SSM provisions;
• removing references to paragraph
(d)(4) of OSHA’s Hazard
Communication standard (29 CFR
1910.1200), which dealt with OSHAdefined carcinogens, and replacing that
reference with a list of HAP that must
be regarded as potentially carcinogenic
based on EPA guidelines;
• adding a requirement to conduct
performance testing and reestablish
operating limits no less frequently than
every 5 years for sources that are using
add-on controls to demonstrate
compliance, unless they are already
required to perform comparable
periodic testing as a condition of
renewing their title V operating permit;
• IBR of alternative test methods and
references to updated alternative test
methods; and
• several minor editorial and
technical changes.
This action also finalizes the proposed
changes to the NESHAP for the Surface
Coating of Metal Coil source category by
adding the option of conducting EPA
Method 18 of appendix A to 40 CFR part
60, ‘‘Measurement of Gaseous Organic
Compound Emissions by Gas
Chromatography,’’ to measure and then
subtract methane emissions from
measured total gaseous organic mass
emissions as carbon; and by revising 40
CFR 63.5090 to clarify that the NESHAP
does not apply to the application of
markings (including letters, numbers, or
symbols) to bare metal coils that are
used for product identification or for
product inventory control.
A. What are the final rule amendments
based on the risk reviews for the Surface
Coating of Metal Cans and Surface
Coating of Metal Coil source categories?
This section describes the final
amendments to the Surface Coating of
Metal Cans NESHAP (subpart KKKK)
and the Surface Coating of Metal Coil
NESHAP (subpart SSSS) being
promulgated pursuant to CAA section
112(f). In this action, we are finalizing
our proposed determinations that risks
from these two subparts are acceptable,
and that the standards provide an ample
margin of safety to protect public health
and to prevent an adverse
environmental effect. The EPA proposed
no changes to these two subparts based
on the risk reviews conducted pursuant
to CAA section 112(f). The EPA received
no new data or other information during
the public comment period that causes
us to change those proposed
determinations. Therefore, we are not
requiring additional controls under
PO 00000
Frm 00006
Fmt 4701
Sfmt 4700
CAA section 112(f)(2) for either of the
two subparts in this action.
B. What are the final rule amendments
based on the technology reviews for the
Surface Coating of Metal Cans and the
Surface Coating of Metal Coil source
categories?
We determined that there are no
developments in practices, processes,
and control technologies that warrant
revisions to the MACT standards for
these source categories. Therefore, we
are not finalizing revisions to the MACT
standards under CAA section 112(d)(6).
C. What are the final rule amendments
addressing emissions during periods of
startup, shutdown, and malfunction?
We are finalizing the proposed
amendments to the Surface Coating of
Metal Cans NESHAP and the Surface
Coating of Metal Coil NESHAP to
eliminate the SSM exemption.
Consistent with Sierra Club v. EPA, 551
F. 3d 1019 (D.C. Cir. 2008), the EPA is
establishing standards in these rules
that apply at all times. As detailed in
section IV.C of the proposal preamble
(84 FR 25904, June 4, 2019), Table 5 to
Subpart KKKK of Part 63 and Table 2 to
Subpart SSSS of Part 63 (General
Provisions applicability tables) are being
revised to change several references
related to the provisions that apply
during periods of SSM. We also
eliminated or revised certain
recordkeeping and reporting
requirements related to the eliminated
SSM exemption. The EPA also made
other harmonizing changes to remove or
modify inappropriate, unnecessary, or
redundant language in the absence of
the SSM exemption. We determined
that facilities in both of these source
categories can meet the applicable
emission standards in the Surface
Coating of Metal Cans NESHAP and the
Surface Coating of Metal Coil NESHAP
at all times, including periods of startup
and shutdown. Therefore, the EPA
determined that no additional standards
are needed to address emissions during
these periods. The legal rationale and
explanation of the changes for SSM
periods are set forth in the proposed
rule. See 84 FR 25925 through 25929
and 25936 through 25939.
Further, the EPA is not finalizing
standards for malfunctions. As
discussed in section IV.C of the June 4,
2019, proposal preamble, the EPA
interprets CAA section 112 as not
requiring emissions that occur during
periods of malfunction to be factored
into development of CAA section 112
standards, although the EPA has the
discretion to set standards for
malfunctions where feasible. For these
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
jbell on DSKJLSW7X2PROD with RULES2
source categories, it is unlikely that a
malfunction would result in a violation
of the standards, and no comments or
information were submitted that
support a contrary conclusion. Refer to
section IV.C of the June 4, 2019 proposal
preamble for further discussion of the
EPA’s rationale for the decision not to
set standards for malfunctions, as well
as a discussion of the actions a source
could take in the unlikely event that a
source fails to comply with the
applicable CAA section 112(d)
standards as a result of a malfunction
event, given that administrative and
judicial procedures for addressing
exceedances of the standards fully
recognize that violations may occur
despite good faith efforts to comply and
the EPA can consider all relevant
information when determining the
appropriate response to those situations.
We are finalizing a revision to the
performance testing requirements at 40
CFR 63.4164 and 40 CFR 63.5160. The
final performance testing provisions
prohibit performance testing during
startup, shutdown, or malfunction as
these conditions are not representative
of steady state operating conditions. The
final rules also require that operators
maintain records to document that
operating conditions during
performance tests represent steady state
conditions.
D. What other changes have been made
to the NESHAPs?
For both the Surface Coating of Metal
Cans NESHAP and the Surface Coating
of Metal Coil NESHAP, the EPA is
finalizing, as proposed, several other
revisions that are described in the
following paragraphs.
To increase the ease and efficiency of
data submittal and data accessibility, we
are finalizing a requirement that owners
and operators of facilities in the Surface
Coating of Metal Cans and Surface
Coating of Metal Coil source categories
submit electronic copies of required
performance test reports through the
EPA’s Central Data Exchange (CDX)
website using an electronic performance
test report tool called the Electronic
Reporting Tool (ERT). We also are
finalizing, as proposed, provisions that
allow facility operators the ability to
seek extensions for submitting
electronic reports for circumstances
beyond the control of the facility, i.e.,
for a possible outage in the CDX or
Compliance and Emissions Data
Reporting Interface (CEDRI) or for a
force majeure event in the time just
prior to a report’s due date, as well as
the process to assert such a claim.
For each subpart, we also are
changing the format of references to test
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
methods in 40 CFR part 60, appendix A
to indicate where, in the eight sections
of appendix A, each method is found.
For each subpart, we are finalizing the
proposal to re-designate the list of
applicable organic HAP that must be
used when a facility chooses to use the
compliant material option (i.e., for
calculating total organic HAP content of
a coating material present at 0.1 percent
or greater by mass). To specify the
applicable HAP, we are changing the
rule to remove the reference to
paragraph (d)(4) of OSHA’s Hazard
Communication standard (29 CFR
1910.1200) and replace it with a new
table in each subpart (Table 8 in 40 CFR
part 63, subpart KKKK and Table 3 in
40 CFR part 63, subpart SSSS) that lists
the applicable HAP. The organic HAP in
these new tables are those HAP that
were categorized in the EPA’s
‘‘Prioritized Chronic Dose-Response
Values for Screening Risk Assessments’’
(dated May 9, 2014) as a ‘‘human
carcinogen,’’ ‘‘probable human
carcinogen,’’ or ‘‘possible human
carcinogen’’ according to The Risk
Assessment Guidelines of 1986 (EPA/
600/8–87/045, August 1987) 2 or as
‘‘carcinogenic to humans,’’ ‘‘likely to be
carcinogenic to humans,’’ or with
‘‘suggestive evidence of carcinogenic
potential’’ according to the Guidelines
for Carcinogen Risk Assessment (EPA/
630/P–03/001F, March 2005).
We are including in the final rule for
each subpart a requirement for facilities
that use control devices to conduct
control device performance testing no
less frequently than once every 5 years.
For facilities with title V permits that
require comparable periodic testing
prior to permit renewal, no additional
testing is required, and we included
provisions in the rule to allow sources
to harmonize the NESHAP testing
schedule with a facility’s current title V
testing schedule.
1. Technical Amendments to the
Surface Coating of Metal Cans NESHAP
In the final rule, we are amending 40
CFR 63.3481(c)(5), as proposed, to
revise the reference to ‘‘future subpart
MMMM’’ of this part by removing the
word ‘‘future’’ because subpart MMMM
was promulgated in 2004.
We are revising the monitoring
provisions for thermal and catalytic
oxidizers, as proposed, to clarify that a
thermocouple is part of the temperature
sensor referred to in 40 CFR
63.3547(c)(3) and 40 CFR 63.3557(c)(3)
2 See https://www.epa.gov/fera/dose-responseassessment-assessing-health-risks-associatedexposure-hazardous-air-pollutants.
PO 00000
Frm 00007
Fmt 4701
Sfmt 4700
10833
for purposes of performing periodic
calibration and verification checks.
Currently, 40 CFR 63.3513(a) allows
records, ‘‘where appropriate,’’ to be
maintained as ‘‘electronic spreadsheets’’
or a ‘‘database.’’ As proposed, we are
adding a clarification to this provision
that the allowance to retain electronic
records applies to all records that were
submitted as reports electronically via
the EPA’s CEDRI. We are also adding
text to the same provision, as proposed,
clarifying that this ability to maintain
electronic copies does not affect the
requirement for facilities to make
records, data, and reports available
upon request to a delegated air agency
or the EPA as part of an on-site
compliance evaluation.
In the final rule, as proposed, we are
adding and updating test methods that
are incorporated by reference. In
accordance with requirements of 1 CFR
51.5, the EPA is incorporating by
reference the following voluntary
consensus standards (VCS) described in
the amendments to 40 CFR 63.14:
• ASTM D1475–13, Standard Test
Method for Density of Liquid Coatings,
Inks, and Related Products, proposed to
be IBR approved for 40 CFR 63.3521(c)
and 63.3531(c);
• ASTM D2111–10 (2015), Standard
Test Methods for Specific Gravity and
Density of Halogenated Organic
Solvents and Their Admixtures,
proposed to be IBR approved for 40 CFR
63.3521(c) and 63.3531(c);
• ASTM D2369–10 (2015), Test
Method for Volatile Content of Coatings,
proposed to be IBR approved for 40 CFR
63.3521(a)(2) and 63.3541(i)(3);
• ASTM D2697–03 (2014), Standard
Test Method for Volume Nonvolatile
Matter in Clear or Pigmented Coatings,
proposed to be IBR approved for 40 CFR
63.3521(b)(1); and
• ASTM D6093–97 (2016), Standard
Test Method for Percent Volume
Nonvolatile Matter in Clear or
Pigmented Coatings Using Helium Gas
Pycnometer, proposed to be IBR
approved for 40 CFR 63.3521(b)(1).
2. Technical Amendments to the
Surface Coating of Metal Coil NESHAP
We are finalizing, as proposed,
changes to 40 CFR 63.5090 to clarify
that 40 CFR part 63, subpart SSSS does
not apply to the application to bare
metal coils of markings (including
letters, numbers, or symbols) that are
used for product identification or for
product inventory control.
We are finalizing amendments to 40
CFR 63.5160(d) in 40 CFR part 63,
subpart SSSS, as proposed, to add the
option of conducting EPA Method 18 of
appendix A to 40 CFR part 60,
E:\FR\FM\25FER2.SGM
25FER2
jbell on DSKJLSW7X2PROD with RULES2
10834
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
‘‘Measurement of Gaseous Organic
Compound Emissions by Gas
Chromatography,’’ to measure and then
subtract methane emissions from
measured total gaseous organic mass
emissions, as carbon, for those facilities
using the emission rate with add-on
control compliance option and EPA
Method 25A to measure control device
destruction efficiency.
Currently 40 CFR 63.5190 specifies
records that must be maintained. We are
adding, as proposed, clarification to 40
CFR 63.5190(c) that specifies the
allowance to retain electronic records
applies to all records that were
submitted as reports electronically via
the EPA’s CEDRI. We are also adding
text to the same provision clarifying that
this ability to maintain electronic copies
does not affect the requirement for
facilities to make records, data, and
reports available upon request to a
delegated air agency or the EPA as part
of an on-site compliance evaluation.
We are clarifying and harmonizing, as
proposed, the general duty requirement
in 40 CFR 63.5140(a) with the reporting
requirements in 40 CFR 63.5180(g)(2)(v)
and 40 CFR 63.5180(h)(4) and the
recordkeeping requirement in 40 CFR
63.5190(a)(5), by including new
language in 40 CFR 63.5140(a) to read
as, ‘‘. . . you must be in compliance
with the applicable emission standards
in § 63.5120 and the operating limits in
Table 1 of this subpart at all times.’’
We are revising, as proposed, the text
in the semi-annual reporting provisions
of 40 CFR 63.5180(g)(2)(v) to read, ‘‘A
statement that there were no deviations
from the applicable emission limit in
§ 63.5120 or the applicable operating
limit(s) established according to
§ 63.5121 during the reporting period,
and that no continuous emissions
monitoring systems (CEMS) were
inoperative, inactive, malfunctioning,
out-of-control, repaired, or adjusted.’’
Conforming changes are also being
made to the reporting requirement at 40
CFR 63.5180(h)(4) and the
recordkeeping requirement at 40 CFR
63.5190(a)(5).
We are revising, as proposed, one
instance in 40 CFR 63.5160(e) in which
an erroneous rule citation,
‘‘§ 63.5170(h)(2) through (4),’’ is made
by correcting the citation to
‘‘§ 63.5170(g)(2) through (4).’’
We are amending, as proposed, 40
CFR 63.5130(a) to clarify that the
compliance date for existing affected
sources is June 10, 2005.
We are amending, as proposed, 40
CFR 63.5160(d)(3)(ii)(D) to correct a
typographical error in a reference to
paragraphs ‘‘(d)(3)(ii)(D)(1 (3).’’ The
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
correct reference is to paragraphs
(d)(3)(ii)(D)(1)–(3).
We are amending, as proposed, 40
CFR 63.5170(c)(1) and (2) to correct the
cross references to 40 CFR 63.5120(a)(1)
or (2). The correct cross references are
to 40 CFR 63.5120(a)(1) or (3).
We are amending, as proposed,
Equation 11 in 40 CFR 63.5170 so that
the value calculated by the equation is
correctly identified as ‘‘He’’ instead of
just ‘‘e.’’
In the final rule, as proposed, we are
adding and updating test methods that
are incorporated by reference. In
accordance with requirements of 1 CFR
51.5, the EPA is incorporating by
reference the following methods and
VCS described in the amendments to 40
CFR 63.14:
• ASTM D1475–13, Standard Test
Method for Density of Liquid Coatings,
Inks, and Related Products, proposed to
be IBR approved for 40 CFR 63.5160(c);
• ASTM D2111–10 (2015), Standard
Test Methods for Specific Gravity and
Density of Halogenated Organic
Solvents and Their Admixtures,
proposed to be IBR approved for 40 CFR
63.5160(c);
• ASTM D2369–10 (2015), Test
Method for Volatile Content of Coatings,
proposed to be IBR approved for 40 CFR
63.5160(b)(2);
• ASTM D2697–03 (2014), Standard
Test Method for Volume Nonvolatile
Matter in Clear or Pigmented Coatings,
proposed to be IBR approved for 40 CFR
63.5160(c); and
• ASTM D6093–97 (2016), Standard
Test Method for Percent Volume
Nonvolatile Matter in Clear or
Pigmented Coatings Using Helium Gas
Pycnometer, proposed to be IBR
approved for 40 CFR 63.5160(c).
E. What are the effective and
compliance dates of the revisions to the
standards?
The revisions to the MACT standards
being promulgated in this action are
effective on February 25, 2020.
The compliance date for existing
affected sources in both the Surface
Coating of Metal Cans and Surface
Coating of Metal Coil source categories
is August 24, 2020, with the exception
of the electronic format for submitting
semiannual compliance reports. New
sources must comply with all of the
standards immediately upon the
effective date of the standard, February
25, 2020, or upon startup, whichever is
later, with the exception of the
electronic format for submitting
semiannual compliance reports. For the
electronic format for submitting
semiannual compliance reports, both
existing and new affected sources will
PO 00000
Frm 00008
Fmt 4701
Sfmt 4700
have 1 year after the electronic reporting
templates are available on CEDRI, or 1
year after February 25, 2020, whichever
is later. The EPA selected these
compliance dates based on experience
with similar industries and the EPA’s
detailed justification for the selected
compliance dates is included in the
preamble to the proposed rule (84 FR
25931 and 25942).
F. What are the requirements for
submission of performance test data to
the EPA?
As proposed, the EPA is taking a step
to increase the ease and efficiency of
data submittal and data accessibility.
Specifically, the EPA is finalizing the
requirement for owners and operators of
facilities in the Surface Coating of Metal
Cans and Surface Coating of Metal Coil
source categories to submit electronic
copies of certain required performance
test reports.
Data will be collected by direct
computer-to-computer electronic
transfer using EPA-provided software.
This EPA-provided software is an
electronic performance test report tool
called the ERT. The ERT will generate
an electronic report package which will
be submitted to CEDRI and then
archived to the EPA’s CDX. A
description of the ERT and instructions
for using ERT can be found at https://
www3.epa.gov/ttn/chief/ert/.
The CEDRI interface can be accessed
through the CDX website (https://
cdx.epa.gov/).
The requirement to submit
performance test data electronically to
the EPA does not create any additional
performance testing requirements and
will apply only to those performance
tests conducted using test methods that
are supported by the ERT. A listing of
the pollutants and test methods
supported by the ERT is available at the
ERT website. Through this approach,
industry will save time in the
performance test submittal process.
Additionally, this rulemaking will
benefit industry by reducing
recordkeeping costs, as the performance
test reports that are submitted to the
EPA using CEDRI are no longer required
to be kept in hard copy.
State, local, and tribal agencies may
benefit from a more streamlined and
accurate review of performance test data
that will become available to the public
through WebFIRE. Having such data
publicly available enhances
transparency and accountability. For a
more thorough discussion of electronic
reporting of performance tests using
direct computer-to-computer electronic
transfer and using EPA-provided
software, see the discussion in the
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
preamble of the proposed rules (84 FR
25904, June 24, 2019) and the
memorandum, Electronic Reporting
Requirements for New Source
Performance Standards (NSPS) and
National Emission Standards for
Hazardous Air Pollutants (NESHAP)
Rules, August 8, 2018, in the Surface
Coating of Metal Cans and Surface
Coating of Metal Coil Dockets.
In summary, in addition to supporting
regulation development, control strategy
development, and other air pollution
control activities, having an electronic
database populated with performance
test data will save industry, state/local/
tribal agencies, and the EPA significant
time, money, and effort while improving
the quality of emission inventories and
air quality regulations.
IV. What is the rationale for our final
decisions and amendments for the
Surface Coating of Metal Cans and
Surface Coating of Metal Coil source
categories?
For each issue, this section provides
a description of what we proposed and
what we are finalizing for the issue, the
EPA’s rationale for the final decisions
and amendments, and a summary of key
comments and responses. For all
comments not discussed in this
preamble, comment summaries and the
EPA’s responses can be found in the
comment summary and response
document available in the Surface
Coating of Metal Cans and Surface
Coating of Metal Coil Dockets.
A. Residual Risk Reviews
1. What did we propose pursuant to
CAA section 112(f)?
10835
a. Surface Coating of Metal Cans (40
CFR Part 63, subpart KKKK) Source
Category
Pursuant to CAA section 112(f), the
EPA conducted a residual risk review
and presented the results of this review,
along with our proposed decisions
regarding risk acceptability and ample
margin of safety, in sections IV.A.2.a
and b of the proposed rule preamble (84
FR 25904, June 24, 2019). The results of
this review are presented briefly below
in Table 2 of this preamble. Additional
detail is provided in the residual risk
technical support document titled,
Residual Risk Assessment for the
Surface Coating of Metal Cans Source
Category in Support of the 2019 Risk
and Technology Review Proposed Rule,
which is available in the Surface
Coating of Metal Cans Docket.
TABLE 2—SURFACE COATING OF METAL CANS SOURCE CATEGORY INHALATION RISK ASSESSMENT RESULTS AT
PROPOSAL
Maximum individual
cancer risk
(in 1 million)
Risk assessment
Based on
actual
emissions
Source Category .........................
Whole Facility ..............................
3
8
Based on
allowable
emissions
3
..................
Estimated population
at increased risk of
cancer ≥1-in-1 million
Based on
actual
emissions
Based on
allowable
emissions
700
1,500
Estimated annual
cancer incidence
(cases per year)
Based on
actual
emissions
800
..................
0.0009
0.002
Maximum
chronic noncancer
TOSHI 1
Based on
allowable
emissions
Based on
actual
emissions
0.001
..................
0.02
0.2
Based on
allowable
emissions
0.02
..................
Maximum
screening
acute
noncancer
HQ 2
HQREL = 0.4.
jbell on DSKJLSW7X2PROD with RULES2
1 The target organ-specific hazard index (TOSHI) is the sum of the chronic noncancer hazard quotients (HQ) values for substances that affect the same target
organ or organ system.
2 The maximum estimated acute exposure concentration was divided by available short-term threshold values to develop HQ values (HQREL = hazard quotient reference exposure level).
The results of the proposal inhalation
risk modeling using actual emissions
data, as shown in Table 2 of this
preamble, indicate that the maximum
individual cancer risk based on actual
emissions (lifetime) is 3-in-1 million
(driven by formaldehyde), the maximum
chronic noncancer TOSHI value based
on actual emissions is 0.02 (driven by
formaldehyde), and the maximum
screening acute noncancer HQ value
(off-facility site) could be up to 0.4
(driven by formaldehyde). At proposal,
the total annual cancer incidence
(national) from these facilities based on
actual emission levels was estimated to
be 0.0009 excess cancer cases per year,
or one case in every 1,100 years.
The results of the proposal inhalation
risk modeling using allowable emissions
data, as shown in Table 2 of this
preamble, indicate that the maximum
individual cancer risk based on
allowable emissions (lifetime) is 3-in-1
million (driven by formaldehyde), and
the maximum chronic noncancer TOSHI
value based on allowable emissions is
0.02 (driven by formaldehyde). At
proposal, the total annual cancer
incidence (national) from these facilities
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
based on allowable emissions was
estimated to be 0.001 excess cancer
cases per year, or one case in every
1,000 years.
The maximum individual cancer risk
(lifetime) for the whole facility was
determined to be 8-in-1 million at
proposal, driven by formaldehyde from
miscellaneous industrial processes
(other/not classified) and acetaldehyde
from beer production (brew kettle). At
proposal, the total estimated cancer
incidence from the whole facility was
determined to be 0.002 excess cancer
cases per year, or one excess case in
every 500 years. Approximately 1,500
people were estimated to have cancer
risks above 1-in-1 million from exposure
to HAP emitted from both MACT and
non-MACT sources at three of the five
facilities in this source category. The
maximum facility-wide TOSHI for the
source category was estimated to be 0.2,
mainly driven by emissions of
acetaldehyde from beer production
(brew kettle) and formaldehyde from
miscellaneous industrial processes
(other/not classified).
There are no persistent and
bioaccumulative HAP (PB HAP) emitted
PO 00000
Frm 00009
Fmt 4701
Sfmt 4700
by facilities in this source category;
therefore, we did not estimate any
human health multi-pathway risks from
this source category. Two
environmental HAP are emitted by
sources within this source category:
Hydrochloric acid (HCl) and hydrogen
fluoride (HF). Therefore, at proposal, we
conducted a screening-level evaluation
of the potential adverse environmental
risks associated with emissions of HCl
and HF. Based on this evaluation, we
proposed that we do not expect an
adverse environmental effect as a result
of HAP emissions from this source
category.
We weighed all health risk factors,
including those shown in Table 2 of this
preamble, in our risk acceptability
determination and proposed that the
residual risks from the Surface Coating
of Metal Cans source category are
acceptable (section IV.A.2.a of proposal
preamble, 84 FR 25922, June 4, 2019).
We then considered whether 40 CFR
part 63, subpart KKKK provides an
ample margin of safety to protect public
health and prevents, taking into
consideration costs, energy, safety, and
other relevant factors, an adverse
E:\FR\FM\25FER2.SGM
25FER2
10836
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
environmental effect. In considering
whether the standards should be
tightened to provide an ample margin of
safety to protect public health, we
considered the same risk factors that we
considered for our acceptability
determination and also considered the
costs, technological feasibility, and
other relevant factors related to
emissions control options that might
further reduce risk associated with
emissions from the source category.
Related to risk, the baseline risks were
low, and regardless of the availability of
further control options, little risk
reduction could be realized. As
discussed further in section IV.B of this
preamble, the only development
identified in the technology review was
the ongoing development and the
potential future conversion from
conventional interior can coatings that
contain bisphenol A (BPA) to interior
coatings that do not intentionally
contain BPA (BPA–NI). Since BPA and
BPA–NI are not HAP, this change would
have no effect on the HAP emissions.
There were no other technological
developments identified that affect HAP
emissions for the Surface Coating of
Metal Cans source category. Therefore,
given the low baseline risks and lack of
options for further risk reductions, we
proposed that additional emission
controls for this source category are not
necessary to provide an ample margin of
safety (section IV.A.2.b of proposal
preamble, 84 FR 25922, June 4, 2019).
b. Surface Coating of Metal Coil (40 CFR
Part 63, Subpart KKKK) Source Category
Pursuant to CAA section 112(f), the
EPA conducted a residual risk review
and presented the results of this review,
along with our proposed decisions
regarding risk acceptability and ample
margin of safety, in sections IV.B.2.a
and b of the proposed rule preamble (84
FR 25904, June 24, 2019). The results of
this review are presented briefly below
in Table 3 of this preamble. Additional
detail is provided in the residual risk
technical support document titled,
Residual Risk Assessment for the
Surface Coating of Metal Coil Source
Category in Support of the 2019 Risk
and Technology Review Proposed Rule,
which is available in the Surface
Coating of Metal Coil Docket.
TABLE 3—SURFACE COATING OF METAL COIL SOURCE CATEGORY INHALATION RISK ASSESSMENT RESULTS AT
PROPOSAL
Maximum
individual cancer risk
(in 1 million)
Risk assessment
Based on
actual
emissions
Source Category ...............................
Whole Facility ....................................
10
40
Based on
allowable
emissions
10
..................
Estimated population
at increased risk of
cancer ≥ 1-in-1 million
Based on
actual
emissions
19,000
270,000
Based on
allowable
emissions
24,000
..................
Estimated annual cancer
incidence
(cases per year)
Based on
actual
emissions
0.005
0.03
Based on
allowable
emissions
Maximum
chronic noncancer
TOSHI 1
Based on
actual
emissions
0.006
..................
0.1
5
Based on
allowable
emissions
0.1
..................
Maximum
screening acute
noncancer HQ 2
HQREL = 3.
1 The
TOSHI is the sum of the chronic noncancer HQ values for substances that affect the same target organ or organ system.
maximum estimated acute exposure concentration was divided by available short-term threshold values to develop HQ values (HQREL = hazard quotient reference exposure level).
jbell on DSKJLSW7X2PROD with RULES2
2 The
The results of the proposal inhalation
risk modeling using actual emissions
data, as shown in Table 3 of this
preamble, indicate that the maximum
individual cancer risk based on actual
emissions (lifetime) is 10-in-1 million
(driven by naphthalene from solvent
storage), the maximum chronic
noncancer TOSHI value based on actual
emissions is 0.1 (driven by glycol ethers
from prime and finish coating
application), and the maximum
screening acute noncancer HQ value
(off-facility site) could be up to 3 (driven
by DGME). At proposal, the total annual
cancer incidence (national) from these
facilities based on actual emission levels
was estimated to be 0.005 excess cancer
cases per year, or one case in every 200
years.
The results of the proposal inhalation
risk modeling using allowable emissions
data, as shown in Table 3 of this
preamble, indicate that the maximum
individual cancer risk based on
allowable emissions (lifetime) is 10-in1 million (driven by naphthalene from
solvent storage), and the maximum
chronic noncancer TOSHI value based
on allowable emissions is 0.1 (driven by
glycol ethers from prime and finish
coating application). At proposal, the
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
total annual cancer incidence (national)
from these facilities based on allowable
emissions was estimated to be 0.006
excess cancer cases per year, or one case
in every 167 years.
The maximum individual cancer risk
(lifetime) for the whole facility was
determined to be 40-in-1 million at
proposal, driven by naphthalene from
equipment cleanup of metal coil coating
processes. At proposal, the total
estimated cancer incidence from the
whole facility was determined to be 0.03
excess cancer cases per year, or one
excess case in every 30 years.
Approximately 270,000 people were
estimated to have cancer risks above 1in-1 million from exposure to HAP
emitted from both MACT and nonMACT sources of the 48 facilities in this
source category. The maximum facilitywide TOSHI for the source category was
estimated to be 5, driven by emissions
of chlorine from a secondary aluminum
fluxing process.
One PB HAP is emitted by facilities in
the source category: lead. In evaluating
the potential for multipathway effects
from emissions of lead, the modeled
maximum annual lead concentration of
0.0004 micrograms per cubic meter (mg/
m3) was compared to the National
PO 00000
Frm 00010
Fmt 4701
Sfmt 4700
Ambient Air Quality Standards
(NAAQS) for lead of 0.15 microgram per
cubic meter (mg/m3). Results of this
analysis confirmed that the NAAQS for
lead would not be exceeded by any
facility. Based on this evaluation, we
proposed that there is no significant
potential for human health multipathway risks as a result of HAP
emissions from this source category.
Two environmental HAP are emitted by
sources within this source category: HF
and lead. Therefore, at proposal we
conducted a screening-level evaluation
of the potential adverse environmental
risks associated with emissions of HF
and lead. Based on this evaluation, we
proposed that we do not expect an
adverse environmental effect as a result
of HAP emissions from this source
category.
We weighed all health risk factors,
including those shown in Table 3 of this
preamble, in our risk acceptability
determination and proposed that the
residual risks from the Surface Coating
of Metal Coil source category are
acceptable (section IV.B.2.a of proposal
preamble, 84 FR 25933 June 4, 2019).
We then considered whether 40 CFR
part 63, subpart SSSS provides an
ample margin of safety to protect public
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
health and prevents, taking into
consideration costs, energy, safety, and
other relevant factors, an adverse
environmental effect. In considering
whether the standards should be
tightened to provide an ample margin of
safety to protect public health, we
considered the same risk factors that we
considered for our acceptability
determination and also considered the
costs, technological feasibility, and
other relevant factors related to
emissions control options that might
further reduce risk associated with
emissions from the source category. As
discussed further in section IV.B of this
preamble, based on our technology
review, we did not identify any
developments in practices, processes, or
control technologies, and, therefore, we
did not propose any changes to the
standards under CAA section 112(d)(6).
Due to the low baseline risks for the
Surface Coating of Metal Coil source
category and lack of options for further
risk reductions, we proposed that
additional emission controls for this
source category are not necessary to
provide an ample margin of safety
(section IV.B.2.b of proposal preamble,
84 FR 25934, June 4, 2019).
jbell on DSKJLSW7X2PROD with RULES2
2. How did the risk reviews change?
We have not changed any aspect of
the risk assessment for either of these
two source categories as a result of
public comments received on the June
2019 proposal.
3. What key comments did we receive
on the risk reviews, and what are our
responses?
We received comments in support of
and against the proposed residual risk
reviews and our determinations that no
revisions were warranted under CAA
section 112(f)(2) for either source
category. Generally, the comments that
were not supportive of our
determinations based on the risk
reviews suggested changes to the
underlying risk assessment
methodology. For example, one
commenter stated that the EPA should
lower the acceptability benchmark so
that risks below 100-in-1 million are
deemed unacceptable, include
emissions outside of the source
categories in question in the risk
assessment, and assume that pollutants
with noncancer health risks have no
safe level of exposure. After review of
all the comments received, we
determined that no changes to our
Science Advisory Board-approved
residual risk review process were
necessary. The comments and our
specific responses can be found in the
document, Summary of Public
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
Comments and Responses for the Risk
and Technology Reviews for Surface
Coating of Metal Cans and Surface
Coating of Metal Coil, available in the
dockets for these actions (Docket ID
Nos. EPA–HQ–OAR–2017–0684 and
EPA–HQ–OAR–2017–0685).
4. What is the rationale for our final
approach and final decisions for the risk
reviews?
As noted in our proposal, the EPA
sets standards under CAA section
112(f)(2) using ‘‘a two-step standardsetting approach, with an analytical first
step to determine an ‘acceptable risk’
that considers all health information,
including risk estimation uncertainty,
and includes a presumptive limit on the
maximum individual risk (MIR) of
‘‘approximately 1-in-10 thousand’’ (see
54 FR 38045, September 14, 1989). We
weigh all health risk factors in our risk
acceptability determination, including
the cancer MIR, cancer incidence, the
maximum chronic noncancer TOSHI,
the maximum acute noncancer HQ, the
extent of noncancer risks, the
distribution of cancer and noncancer
risks in the exposed population, and the
risk estimation uncertainties.
Since proposal, neither the risk
assessment nor our determinations
regarding risk acceptability, ample
margin of safety, or adverse
environmental effects have changed. For
the reasons explained in the proposed
rule, we determined that the risks from
the Surface Coating of Metal Cans and
the Surface Coating of Metal Coil source
categories are acceptable, and that the
current standards provide an ample
margin of safety to protect public health
and prevent an adverse environmental
effect. Therefore, we are not revising
either subpart to require additional
controls pursuant to CAA section
112(f)(2) based on the residual risk
review, and we are readopting the
existing standards under CAA section
112(f)(2).
B. Technology Reviews
1. What did we propose pursuant to
CAA section 112(d)(6)?
Based on our review, we did not
identify any developments in practices,
processes, or control technologies for
the Surface Coating of Metal Cans
source category, and, therefore, we did
not propose any changes to the
standards under CAA section 112(d)(6).
A brief summary of the EPA’s findings
in conducting the technology review of
metal can coating operations was
included in the preamble to the
proposed rule (84 FR 25922, June 4,
2019), and a detailed discussion of the
PO 00000
Frm 00011
Fmt 4701
Sfmt 4700
10837
EPA’s technology review and findings
was included in the memorandum,
Technology Review for Surface Coating
Operations in the Metal Can Category,
April 24, 2019, in the Surface Coating of
Metal Cans Docket.
Based on our review, we did not
identify any developments in practices,
processes, or control technologies for
the Surface Coating of Metal Coil source
category, and, therefore, we did not
propose any changes to the standards
under CAA section 112(d)(6). A brief
summary of the EPA’s findings in
conducting the technology review of
coil coating operations was included in
the preamble to the proposed rule (84
FR 25934, June 4, 2019), and a detailed
discussion of the EPA’s technology
review and findings was included in the
memorandum, Technology Review for
Surface Coating Operations in the Metal
Coil Category, September 2017, in the
Surface Coating of Metal Coil Docket.
2. How did the technology reviews
change?
We are making no changes to the
conclusions of the technology reviews
and are finalizing the results of the
technology reviews for the Surface
Coating of Metal Cans and Surface
Coating of Metal Coil source categories
as proposed.
3. What key comments did we receive
on the technology reviews, and what are
our responses?
We received two general comments
supporting the results of our technology
reviews for metal cans and metal coil
surface coating and one comment
objecting to our conclusions that there
have been no technology developments
in these two source categories.
Comment: One commenter alleged
that the EPA has not met the legal
obligation under CAA section 112(d)(6)
to review and revise emission standards
‘‘as necessary’’ to account for
‘‘developments in practices, processes,
and control technologies.’’ The
commenter objected that the EPA
proposed no revisions to the emission
limits and claimed the EPA provided no
legally valid or rational explanation for
its determination of a lack of
‘‘developments’’ for these two source
categories. The commenter pointed out
that the EPA identified several HAP
control advancements, including
alternative coatings, developments for
similar source categories, and work
practices and housekeeping measures
for metal coil facilities, which would
reduce emissions and are in use at a
number of facilities, yet failed to
determine that it was ‘‘necessary’’ to
revise the standard. In addition, the
E:\FR\FM\25FER2.SGM
25FER2
jbell on DSKJLSW7X2PROD with RULES2
10838
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
commenter alleged that the EPA
technology review analysis did not
consider some relevant sources to
determine ‘‘developments.’’ As
examples, the commenter stated that the
EPA did not analyze any control
methods or requirements from other
national or state or local jurisdictions
that might have proven more effective;
did not appear to analyze the different
methods or brands of emission controls
implemented to see which was most
effective, efficient, or reliable; and did
not examine facility procedures or best
practices, including records of
malfunctions, to identify best practices
to mitigate malfunctions.
Response: We disagree with the
commenter that the EPA has failed to
meet the CAA’s legal obligation to
complete the technology reviews for the
Surface Coating of Metal Cans and
Surface Coating of Metal Coil source
categories. The EPA concluded there
were no HAP control advancements for
these source categories as a result of the
technology reviews. The technology
reviews included review of coatings
currently used by these source
categories and any advancements in the
coatings; review of HAP control
requirements in NESHAP for similar
coating source categories and
application of those HAP controls to the
Surface Coating of Metal Cans and
Surface Coating of Metal Coil source
categories; state and local HAP control
requirements in facility title V operating
permits and application of those HAP
controls to the Surface Coating of Metal
Cans and Surface Coating of Metal Coil
source categories; and work practices
and housekeeping measures currently
used by these source categories and any
advances that were applicable to these
source categories.
As stated in the proposal preamble
(84 FR 25935) for the Surface Coating of
Metal Coil source category, alternatives
to solvent borne coatings have been in
use by the coil coating industry since
development of the 2002 Surface
Coating of Metal Coil NESHAP but are
not considered to be suitable for all endproduct applications. The 2002
proposed NESHAP provided an
alternative facility HAP emission limit
of 0.24 pounds of HAP per gallon of
solids applied which was established to
provide a compliance option for
facilities that chose to limit their coating
line HAP emissions either through a
combination of low-HAP coatings and
add-on controls or through the use of
waterborne, high solids, or other
pollution prevention coatings. The EPA
found no developments in alternative
coating technologies during the
technology review that would result in
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
achievable emission rates that are
substantially lower than those reflected
in the current emission limits.
The commenter also asserted that the
EPA did not consider developments in
control methods for similar source
categories and did not analyze the
regulations set by state or local
jurisdictions that might have proven
more effective than the NESHAP
requirements. We disagree with the
commenter and refer the commenter to
the technology review memorandums
titled Technology Review for Surface
Coating Operations in the Metal Can
Category and Technology Review for
Surface Coating Operations in the Metal
Coil Category which summarizes the
EPA’s review of the title V operating
permits for the five metal can facilities
and for 39 metal coil facilities that are
major sources and subject to these
NESHAP. The title V operating permits
incorporate all relevant local, state, or
Regional emission limitations, as well as
federal limitations. In no case did the
EPA find a facility subject to a HAP
limit more stringent than the limits in
the current NESHAP or a facility using
a control technology that was not
considered during development of the
NESHAP and reflected in the current
standards. The results of the technology
reviews were documented in these
memorandums in the respective docket
for each proposed rule.
The technology basis for MACT for
metal coil coating operations in the
2002 Surface Coating of Metal Coil
NESHAP was emission capture and add
on control with an overall control
efficiency of 98 percent for new or
reconstructed sources and existing
sources. This overall control efficiency
represents the use of PTE to achieve
100-percent capture of application
station HAP emissions and a thermal
oxidizer to achieve a destruction
efficiency of 98 percent. No technology
was identified during the technology
review that could achieve a better
overall control efficiency than the use of
a PTE to capture HAP emissions from
the coating application station and a
thermal oxidizer to destroy HAP
emissions from the coating application
and the curing oven.
It would not be feasible, nor is it
required under CAA section 112(d)(6),
for the EPA to evaluate HAP control
advancement by examining different
brands of emission controls to see
which was most effective, efficient, or
reliable, as suggested by the commenter.
Similarly, it would not be feasible to
examine facility procedures or best
practices, nor review records of
malfunctions to identify best practices
to mitigate malfunctions. That
PO 00000
Frm 00012
Fmt 4701
Sfmt 4700
information is not currently available to
the EPA. If the information was
available, it would be difficult, if not
impossible, to correlate that information
with emissions performance and
develop practical regulatory
requirements. Instead, the current
emission limits are based on actual
performance of existing sources in the
two categories determined to represent
the MACT level of control for new and
existing sources. The performance data
used to develop the emission limits
were collected during emission tests
when the control devices were
performing properly and the emission
sources were at steady-state operating
conditions. Data collected during
periods of startup, shutdown, or
malfunction were not used to establish
the emission limits. After the initial
compliance demonstration, facilities
using add-on controls must comply with
operating limits to ensure the add-on
controls continue to be properly
operated and maintained to achieve the
same level of performance as during the
performance test. Facilities experiencing
deviations from the emission limits or
the operating limits must report these
deviations to the EPA, and the EPA will
then determine on a case-by-case basis
whether the deviation constitutes a
violation. Because of the diversity of
factors that could lead to a malfunction
in these source categories, it would not
be practical for the EPA to prescribe
specific actions that must be taken to
reduce the frequency of malfunctions or
to minimize emissions in the event of a
malfunction.
The commenter also asserted that the
EPA identified work practices and
housekeeping measures for metal coil
facilities, which would reduce
emissions and are in use at a number of
facilities yet failed to determine that it
was ‘‘necessary’’ to revise the standard.
The commenter’s assertion appears to be
based on a statement in the preamble to
the proposal where we note that the
facility survey conducted as part of the
development of the 2002 MACT
standard for Surface Coating of Metal
Coil had revealed several types of work
practices and housekeeping measures in
use at that time. (84 FR at 25935). We
also noted in the preamble, however,
that we had identified no developments
in work practices or procedures for the
Surface Coating of Metal Coil source
category. As the commenter has
provided no additional information
regarding possible developments and as
the EPA has no information about
developments in such work practices
and housekeeping measures, we do not
agree that it is necessary to revise the
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
standard for this source category as a
result of the technology review.
4. What is the rationale for our final
approach for the technology reviews?
For the reasons explained in the
preamble to the proposed rules (84 FR
25922 and 25934, June 4, 2019), and in
the comment responses above in section
IV.B.3 of this preamble, we are making
no changes and are finalizing the results
of the technology reviews as proposed.
jbell on DSKJLSW7X2PROD with RULES2
C. Electronic Reporting Provisions
1. What did we propose?
In the June 4, 2019, notice we
proposed to require owners and
operators of surface coating of metal can
and metal coil facilities to submit
electronic copies of notifications,
reports, and performance tests through
the EPA’s CDX, using the CEDRI. These
include the initial notifications required
in 40 CFR 63.9(b) and 63.3510(b) for
metal can coating and 63.5180(b) for
metal coil coating; notifications of
compliance status required in 40 CFR
63.9(h) and 63.3510(c) for metal can
coating and 63.5180(d) for metal coil
coating; the performance test reports
required in 40 CFR 63.3511(b) for metal
can coating and 63.5160(d) for metal
coil coating; and the semiannual reports
required in 40 CFR 63.3511(a) for metal
can coating and 63.5180(g) for metal coil
coating. A description of the electronic
submission process is provided in the
memorandum, Electronic Reporting
Requirements for New Source
Performance Standards (NSPS) and
National Emission Standards for
Hazardous Air Pollutants (NESHAP),
August 8, 2018, in the Surface Coating
of Metal Cans and Surface Coating of
Metal Coil Dockets. The proposed rule
requirements would replace the current
rule requirements to submit the
notifications and reports to the
Administrator at the appropriate
address listed in 40 CFR 63.13. The
proposed rule requirement would not
affect submittals required by state air
agencies. For metal can facilities, the
proposed compliance schedule language
in 40 CFR 63.3511(f) for submission of
semiannual compliance reports would
have provided 181 days after the final
rule is published to begin electronic
reporting or 1 year after the 40 CFR part
63, subpart KKKK semiannual
compliance report template is available
in CEDRI, whichever is later. For metal
coil facilities, the proposed compliance
schedule language in 40 CFR 63.5181(c)
for submission of semiannual
compliance reports would have
provided 1 year after the final rule is
published to begin electronic reporting
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
or 1 year after the 40 CFR part 63,
subpart SSSS semiannual compliance
report template is available in CEDRI,
whichever is later.
2. What changed since proposal?
For metal can facilities, the
compliance schedule language in
proposed 40 CFR 63.3511(f) for
submission of semiannual compliance
reports has been revised from the
proposed 181 days, to either 1 year after
the final rule is published or 1 year after
the 40 CFR part 63, subpart KKKK,
semiannual compliance report template
is available in CEDRI, whichever is
later. No changes were made to the
metal coil compliance schedule.
3. What key comments did we receive
and what are our responses?
Comment: One commenter suggested
that the EPA change the metal can
compliance schedule language in
proposed 40 CFR 63.3511(f) for
submission of semiannual compliance
reports to give facilities either 1year
(instead of 181 days) after the final rule
is published to begin electronic
reporting or 1 year after the 40 CFR part
63, subpart KKKK, semiannual
compliance report template is available
in CEDRI, whichever is later. The
commenter recommended revising 40
CFR 63.3511(f) to say that on and after
the date 1 year (instead of 181 days)
after the date of publication of the final
rule in the Federal Register, or once the
reporting template has been available on
the CEDRI website for 1 year, whichever
date is later, the owner or operator is
required to submit the semiannual
compliance report via the CEDRI. The
commenter noted that the proposed 181day requirement for 40 CFR part 63,
subpart KKKK, is not consistent with
the 1-year requirement the EPA is
proposing for 40 CFR 63.5181(c) in 40
CFR part 63, subpart SSSS for the
Surface Coating of Metal Coil source
category. The commenter also argued
that 1 year would be justified because
metal can coating facilities are not
currently using CEDRI and would need
to learn how to access and use CEDRI.
Response: The EPA agrees that both
rules should be consistent and that the
owners and operators should have 1
year after the date of publication of the
final rule or 1 year after the reporting
template has been on CEDRI, whichever
is later, before they are required to
submit semiannual compliance reports
via CEDRI. This will provide users 1
year to become familiar with the
template and electronic reporting
system prior to being required to submit
reports electronically. This will provide
adequate time for facilities to adjust to
PO 00000
Frm 00013
Fmt 4701
Sfmt 4700
10839
electronic reporting, as well as assure
that the forms will work properly, prior
to the date that owners and operators
must start submitting these reports
electronically. The EPA encourages
users to become familiar with the
system well in advance of being
required to use it. For previous
rulemakings with reports required to be
submitted electronically via CEDRI,
prior to a compliance reporting
deadline, the EPA has provided
webinars to our various stakeholders on
the access and reporting of the given
report in CEDRI. The EPA is planning to
provide this same service to the
industry trade association and facilities
subject to the 40 CFR part 63, subparts
KKKK and SSSS electronic reporting
requirements, if requested to do so. The
EPA plans to publish the final template
on CEDRI about the same time the final
rule is signed and published. Although
facilities will have up to 1 year after the
final template is on CEDRI to begin
using the template and submitting
reports via CEDRI, facilities may begin
submitting reports via CEDRI as soon as
the final template is available.
Comment: One commenter stated they
will need an interactive discussion with
the EPA (e.g., by conference call or
webinar) to answer questions about how
to use CEDRI and about the draft
electronic reporting template before
they can effectively comment on
whether the template is appropriate and
workable for metal can surface coating
facilities subject to subpart 40 CFR part
63, KKKK. The commenter further asked
that the EPA not finalize the reporting
template until after the proposed rule is
finalized.
Response: The EPA agrees that
interactive discussions via conference
calls or a webinar with the industry
trade organization and members would
be appropriate to review the electronic
reporting process using CEDRI and to
collaborate on improvements to the
draft electronic reporting template. The
EPA has arranged interactive
discussions with both the metal can and
metal coil industry trade organizations
and members in an attempt to finalize
the electronic reporting templates
concurrent with the final rule
promulgation. If that is the case
facilities will have 1 year after the final
rule is published to submit notifications
and semiannual compliance reports
using the electronic reporting template
in CEDRI. If the reporting templates are
not finalized concurrent with the final
rule promulgation, the EPA will
continue to work with the industry
trade organizations and members to
finalize the templates and will make the
final templates available on the CEDRI
E:\FR\FM\25FER2.SGM
25FER2
10840
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
website. Facilities would then be
required to submit notifications and
semiannual compliance reports using
the electronic reporting template in
CEDRI one year after the reporting
template has been available on the
CEDRI website.
4. What is the rationale for our final
approach for the electronic reporting
provisions?
For the reasons explained in the
preamble to the proposed rules (84 FR
25922 and 25934, June 4, 2019), and in
the comment responses above in section
IV.C.3 of this preamble, we are
finalizing the electronic reporting
provisions for both 40 CFR parts 63,
subparts KKKK and SSSS, as proposed
with the exception of the change in date
by which electronic reporting must
commence for the Surface Coating of
Metal Cans source category (described
in section IV.C.2 of this preamble).
D. SSM Provisions
1. What did we propose?
In the June 4, 2019, action, we
proposed amendments to the Surface
Coating of Metal Cans NESHAP and the
Surface Coating of Metal Coil NESHAP
to remove and revise provisions related
to SSM that are not consistent with the
requirement that the standards apply at
all times. More information concerning
the elimination of SSM provisions is in
the preamble to the proposed rule (84
FR 25909, June 4, 2019).
2. What changed since proposal?
We are finalizing the SSM provisions
as proposed with no changes (84 FR
25909, June 4, 2019).
jbell on DSKJLSW7X2PROD with RULES2
3. What key comments did we receive
and what are our responses?
Comment: One commenter noted that
new language has been proposed for 40
CFR 63.5150(a) which states that on and
after the compliance date sources must
also maintain the monitoring equipment
at all times in accordance with 40 CFR
63.5140(b) and keep the necessary parts
readily available for routine repairs of
the monitoring equipment. The
commenter expressed concern that
different inspectors could have different
interpretations of what parts would be
‘‘necessary’’ to be kept readily available
and what repairs would be ‘‘routine.’’
The commenter recommended revising
the proposed language for 40 CFR
63.5150(a) to omit ‘‘and keep the
necessary parts readily available for
routine repairs of the monitoring
equipment.’’
The commenter argued that the
compliance requirement language will
always be open to some degree of
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
interpretation, but the suggested change
would minimize differences in how this
new language is interpreted and allow
the individual facilities to manage and
defend their compliance practices
required in this section as they see best.
Response: The EPA disagrees with the
commenter and is not accepting this
recommended change. The requirement
is not new, it was simply moved from
the 40 CFR part 63 General Provisions
to subparts KKKK and SSSS. The
language proposed for 40 CFR
63.5150(a) replaces language in 40 CFR
63.8(c)(1)(i) and (ii) that no longer
applies. The EPA is amending Table 5
to Subpart KKKK of Part 63 so that 40
CFR 63.8(c)(1) no longer applies because
40 CFR 63.8(c)(1)(iii) requires, ‘‘The
owner or operator of an affected source
must develop a written startup,
shutdown, and malfunction plan for
CMS as specified in § 63.6(e)(3).’’
Because 40 CFR 63.8(c)(1) no longer
applies as part of the amendments to
remove the SSM exemptions, the
provisions of 40 CFR 63.8(c)(1)(i) and
(ii) are being added to each subpart. The
EPA disagrees that the proposed
language would lead to differences in
interpretation and the commenter
provided no evidence that the same
language led to compliance issues when
it was located only in 40 CFR
63.8(c)(1)(ii).
4. What is the rationale for our final
approach for the SSM provisions?
For the reasons explained in the
proposed rule and after evaluation of
the comments on the proposed
amendments to the SSM provisions for
the Surface Coating of Metal Cans
NESHAP and the Surface Coating of
Metal Coil NESHAP, we are finalizing
the proposed revisions related to SSM
that are not consistent with the
requirement that the standards apply at
all times. More information concerning
the proposed amendments to the SSM
provisions is in the preamble to the
proposed rule (84 FR 25909, June 4,
2019).
E. Ongoing Compliance Demonstrations
1. What did we propose?
In the June 4, 2019, action we
proposed to require owners and
operators of surface coating of metal can
facilities and surface coating of metal
coil facilities to conduct periodic
performance testing of add-on control
devices on a regular frequency of every
5 years to ensure the equipment
continues to operate properly for
facilities using the emission rate with
add-on controls compliance option.
This proposed periodic testing
PO 00000
Frm 00014
Fmt 4701
Sfmt 4700
requirement included an exception to
the general requirement for periodic
testing for facilities using the catalytic
oxidizer control options and following
catalyst maintenance procedures that
are found in both 40 CFR part 63,
subparts KKKK and SSSS. These
catalyst maintenance procedures
include annual testing of the catalyst
and other maintenance procedures that
provide ongoing demonstrations that the
control system is operating properly and
may, thus, be considered comparable to
conducting a performance test. The
proposed periodic performance testing
requirement also allows an exception
from periodic testing for facilities using
CEMS to show actual emissions. The
use of CEMS to demonstrate compliance
would obviate the need for periodic
testing.
This proposed requirement did not
require periodic testing or CEMS
monitoring of facilities using the
compliant materials option or the
emission-rate without add-on controls
compliance option because these two
compliance options do not use any addon controls or control efficiency
measurements in the compliance
calculations.
The proposed periodic performance
testing requirement requires facilities
complying with the standards using
emission capture systems and add-on
controls and which are not already on
a 5-year testing schedule to conduct the
first of the periodic performance tests
within 3 years of the effective date of
the revised standards. Afterward, they
would generally conduct periodic
testing before they renew their title V
operating permits, but in no case more
than 5 years following the previous
performance test. Additionally, facilities
that have already tested as a condition
of their permit within the last 2 years
before the effective date would be
permitted to maintain their current 5year schedule.
2. What changed since proposal?
We have revised the proposed
periodic testing language in 40 CFR part
63, subparts KKKK and SSSS, since
proposal to clarify that facilities already
conducting comparable periodic testing
as a requirement of renewing their title
V operating permit under 40 CFR part
70 or part 71 may continue with their
current testing schedule. We also
reformatted the electronic reporting
language in 40 CFR part 63, subparts
KKKK and SSSS, to provide
clarification on the requirements for
asserting a claim of EPA system outage
or force majeure for failure to timely
comply with the reporting requirements.
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
3. What key comments did we receive
and what are our responses?
subparts KKKK and SSSS in section
IV.D.2 of this preamble.
Comment: One commenter
recommended that language in the
proposed rule for 40 CFR part 63,
subpart KKKK should be revised to
more clearly state that facilities are
permitted to use the performance tests
conducted under their title V permits, as
required by state and local permitting
authorities, to meet the proposed
requirement for periodic performance
testing under 40 CFR part 63, subpart
KKKK. The commenter suggested that
the EPA modify the proposed language
for 40 CFR 63.3540(a)(1)(ii),
63.3540(b)(1)(ii), 63.3550(a)(1)(ii), and
63.3550(b)(1)(ii) and offered clarifying
language to say that if a source is not
required to complete periodic
performance tests as a requirement of
renewing its title V operating permit
under 40 CFR part 70 or 40 CFR part 71,
it must conduct the first periodic
performance test before the date 3 years
after date of publication of the final rule
in the Federal Register, unless the
source has already conducted a
performance test on or after the date 2
years before the date of publication of
the final rule in the Federal Register.
The commenter then suggested adding
language to say that if a source is
already required to complete periodic
performance tests as a requirement of
renewing its title V operating permit
under 40 CFR part 70 or 40 CFR part 71,
it must conduct the periodic testing in
accordance with the terms and schedule
required by its permit conditions.
Response: The EPA agrees that the
recommended changes would clarify
that facilities can continue to use tests
conducted under title V to meet the 40
CFR part 63, subpart KKKK requirement
to conduct periodic performance tests.
The EPA is making the recommended
changes to 40 CFR 63.3540(a)(1)(ii),
63.3540(b)(1)(ii), 63.3550(a)(1)(ii), and
63.3550(b)(1)(ii) and is making
comparable changes to Table 1 To 40
CFR 63.5160—Required Performance
Testing Summary, in 40 CFR part 63,
subpart SSSS.
V. Summary of Cost, Environmental,
and Economic Impacts and Additional
Analyses Conducted
jbell on DSKJLSW7X2PROD with RULES2
4. What is the rationale for our final
approach for the ongoing compliance
demonstrations?
For the reasons explained in the
preamble to the proposed rules (84 FR
25922 and 25934, June 4, 2019), and in
the comment responses above in section
IV.C.3 of this preamble, we are
finalizing the periodic testing provisions
for both 40 CFR part 63, subparts KKKK
and SSSS, as proposed with the
exception of the rule clarification
change described for 40 CFR part 63,
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
A. What are the affected sources?
Currently, five major sources subject
to the Surface Coating of Metal Cans
NESHAP are operating in the United
States. The affected source under the
NESHAP is the collection of all
equipment used to apply coating to a
metal can or end (including decorative
tins), or metal crown or closure, and to
dry or cure the coating after application;
all storage containers and mixing
vessels in which coatings, thinners, and
cleaning materials are stored or mixed;
all manual and automated equipment
and containers used for conveying
coatings, thinners, and cleaning
materials; and all storage containers and
all manual and automated equipment
and containers used for conveying waste
materials generated by the coating
operations. A coating operation always
includes at least the point at which a
coating is applied and all subsequent
points in the affected source where
organic HAP emissions from that
coating occur. There may be multiple
coating operations in an affected source.
Currently, 48 major sources subject to
the Surface Coating of Metal Coil
NESHAP are operating in the United
States. The affected source under the
NESHAP is the collection of all the coil
coating lines at a facility, including the
equipment used to apply an organic
coating to the surface of metal coil. A
coil coating line includes a web unwind
or feed section, a series of one or more
work stations, and any associated curing
oven, wet section, and quench station.
A coil coating line does not include
ancillary operations such as mixing/
thinning, cleaning, wastewater
treatment, and storage of coating
material. Metal coil is a continuous
metal strip that is at least 0.15 mm
(0.006 inch) thick, which is packaged in
a roll or coil prior to coating. Material
less than 0.15 mm (0.006 inch) thick is
considered metal foil, not metal coil.
The NESHAP applies to coating lines on
which more than 15 percent of the
material coated, based on surface area,
meets the definition of metal coil. There
may be multiple coating operations in
an affected source.
B. What are the air quality impacts?
The EPA estimates the current
emissions of volatile organic HAP from
the Surface Coating of Metal Cans
source category are approximately 77
tpy and the current emissions of volatile
PO 00000
Frm 00015
Fmt 4701
Sfmt 4700
10841
organic HAP from the Surface Coating of
Metal Coil source category are
approximately 291 tpy.
The amendments require that all 53
major sources in the Surface Coating of
Metal Cans and Surface Coating of Metal
Coil source categories comply with the
relevant emission standards at all times,
including periods of SSM. We were
unable to quantify the emissions that
occur during periods of SSM or the
specific emissions reductions that will
occur as a result of this action. However,
eliminating the SSM exemption has the
potential to reduce emissions by
requiring facilities to meet the
applicable standard during SSM
periods.
The amendments will have no effect
on the energy needs of the affected
facilities in either of the two source
categories and will, therefore, have no
adverse energy impacts or indirect or
secondary air emissions impacts. Energy
impacts consist of the electricity and
steam needed to operate control devices
and other equipment. Indirect or
secondary air emissions impacts are
impacts that would result from the
increased energy usage associated with
the operation of control devices (e.g.,
increased secondary emissions of
criteria pollutants from power plants).
C. What are the cost impacts?
We estimate that each facility in these
two source categories will experience
increased costs as a result of these final
amendments for recordkeeping and
reporting. Each facility will experience
costs to read and understand the rule
amendments. Costs associated with
elimination of the SSM exemption were
estimated as part of the reporting and
recordkeeping costs and include time
for re-evaluating and modifying, as
necessary, previously developed SSM
record systems. Costs associated with
the requirement to electronically submit
notifications and semi-annual
compliance reports using CEDRI were
estimated as part of the reporting and
recordkeeping costs and include time
for becoming familiar with CEDRI and
the reporting template for semi-annual
compliance reports. The recordkeeping
and reporting costs are presented in
section VI.C of this preamble.
We are also finalizing a requirement
for performance testing no less
frequently than every 5 years for sources
in each source category that use the addon controls compliance options. We
estimate that the new periodic testing
requirement will impose additional
costs for 22 facilities across the two
source categories. We estimate that one
facility using three add-on control
devices subject to the Surface Coating of
E:\FR\FM\25FER2.SGM
25FER2
jbell on DSKJLSW7X2PROD with RULES2
10842
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
Metal Cans NESHAP will incur costs to
conduct control device performance
testing because it is using the emission
rate with add-on controls compliance
option and is not required by its title V
operating permit to conduct testing
every 5 years. We estimate that 21
facilities subject to the Surface Coating
of Metal Coil NESHAP will incur costs
to conduct periodic testing because they
are currently using the emission rate
with add-on controls compliance option
and are not required by their title V
operating permits to conduct testing
every 5 years. These 21 metal coil
coating facilities have a total of 30 addon control devices. This total does not
include facilities in the Surface Coating
of Metal Coil source category that have
add-on controls and are currently
required to perform periodic
performance testing as a condition of
their title V operating permit. The cost
for a facility to conduct a destruction or
removal efficiency performance test
using EPA Method 25 or 25A is
estimated to be about $19,000, with tests
of additional control devices at the same
facility costing 25 percent less due to
reduced travel costs. The estimated total
cost for the one metal can surface
coating facility to test three add-on
control devices in a single year would
be $47,000. The estimated total cost for
all 21 metal coil facilities to test 30 addon control devices in a single year, plus
two retests to account for 5 percent of
control devices failing to pass the first
test, would be $560,000. The total
annualized testing cost is estimated to
be approximately $11,000 per year for
the Surface Coating of Metal Cans
source category, and $130,000 per year
for the Surface Coating of Metal Coil
source category, including retests. In
addition to the testing costs, each
facility performing a test will have an
estimated additional $5,500 in reporting
costs in the year in which the test
occurs.
As a result of changes to
recordkeeping and reporting
requirements, a one-time review of the
updated rule language, and the addition
of the periodic testing requirement for
facilities using add-on controls, the
costs of the final amendments are
estimated to be $21,800 for the Surface
Coating of Metal Cans source category
and $271,000 for the Surface Coating of
Metal Coil source category averaged
over the first 3 years after the
amendments are finalized. For further
information on the estimated costs, see
the cost tables in the memoranda titled
Estimated Costs/Impacts of the 40 CFR
part 63 Subparts KKKK and SSSS
Monitoring Review Revisions, February
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
2019, and the Economic Impact and
Small Business Screening Assessments
for Hazardous Air Pollutants for Metal
Cans Coating Plants (Subpart KKKK)
and the Economic Impact and Small
Business Screening Assessments for
Hazardous Air Pollutants for Metal Coil
Coating Plants (Subpart SSSS) in the
Surface Coating of Metal Cans and
Surface Coating of Metal Coil Dockets.
D. What are the economic impacts?
The economic impact analysis is
designed to inform decision makers
about the potential economic
consequences of a regulatory action. For
the final revisions, the EPA estimated
the cost of becoming familiar with the
rule and re-evaluating and revising, as
necessary, previously developed SSM
record systems and performing periodic
emissions testing at certain facilities
with add-on controls that are not
already required to perform testing. To
assess the maximum potential impact,
the largest cost expected to be
experienced in any 1 year is compared
to the total sales for the ultimate owners
of the affected facilities to estimate the
total burden for each ultimate owner.
For the final revisions to the NESHAP
for the Surface Coating of Metal Cans,
the annualized cost is estimated to be
$11,000 for the five affected entities.
The five affected facilities are owned by
three different parent companies, and
the total costs associated with the final
requirements range from 0.00002 to 0.77
percent of annual sales revenue per
ultimate owner. These costs are not
expected to result in a significant
market impact, regardless of whether
they are passed on to the purchaser or
absorbed by the firms.
For the final revisions to the NESHAP
for the Surface Coating of Metal Coil,
the annualized cost is estimated to be
$130,000 for the 48 affected entities.
The 48 affected facilities are owned by
25 different parent companies, and the
total costs associated with the proposed
requirements range from 0.00001 to 0.28
percent of annual sales revenue per
ultimate owner. These costs are not
expected to result in a significant
market impact, regardless of whether
they are passed on to the purchaser or
absorbed by the firms.
The EPA also prepared a small
business screening assessment to
determine whether any of the identified
affected entities are small entities, as
defined by the U.S. Small Business
Administration. One of the facilities
potentially affected by the final
revisions to the NESHAP for the Surface
Coating of Metal Cans is a small entity.
Ten of the facilities potentially affected
by the final revisions to the NESHAP for
PO 00000
Frm 00016
Fmt 4701
Sfmt 4700
the Surface Coating of Metal Coil are
small entities. However, the annualized
costs associated with the final revisions
for the seven ultimate owners of these
eleven affected small entities range from
0.0029 to 0.77 percent of annual sales
revenues per ultimate owner. Therefore,
there are no significant economic
impacts on a substantial number of
small entities from these final
amendments.
More information and details of this
analysis are provided in the technical
documents titled Economic Impact and
Small Business Screening Assessments
for Proposed Amendments to the
National Emission Standards for
Hazardous Air Pollutants for the
Surface Coating of Metal Cans (Subpart
KKKK) and Economic Impact and Small
Business Screening Assessments for
Proposed Amendments to the National
Emission Standards for Hazardous Air
Pollutants for the Surface Coating of
Metal Coil (Subpart SSSS), available in
the Surface Coating of Metal Cans and
Surface Coating of Metal Coil Dockets,
respectively.
E. What are the benefits?
As stated above in section V.B of this
preamble, we were unable to quantify
the specific emissions reductions
associated with eliminating the SSM
exemption or as a result of adding the
requirement to conduct periodic add-on
control device performance tests,
although these final revisions have the
potential to reduce emissions of volatile
organic HAP.
Because these final amendments are
not considered economically significant,
as defined by Executive Order 12866,
and because we were unable to quantify
the specific emission reductions that
will occur as a result of this action, we
did not monetize the benefits of
reducing these emissions. This does not
mean that there are no benefits
associated with the potential reduction
in volatile organic HAP from this rule.
F. What analysis of environmental
justice did we conduct?
Executive Order 12898 (59 FR 7629,
February 16, 1994) establishes federal
executive policy on environmental
justice. Its main provision directs
federal agencies, to the greatest extent
practicable and permitted by law, to
make environmental justice part of their
mission by identifying and addressing,
as appropriate, disproportionately high
and adverse human health or
environmental effects of their programs,
policies, and activities on minority
populations and low-income
populations in the United States.
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
To examine the potential for any
environmental justice issues that might
be associated with these source
categories, we performed a demographic
analysis for each source category, which
is an assessment of risks to individual
demographic groups of the populations
living within 5 kilometers (km) and
within 50 km of the facilities. In these
analyses, we evaluated the distribution
of HAP-related cancer and noncancer
risks from each source category across
different demographic groups within the
populations living near facilities.
1. Surface Coating of Metal Cans
The results of the demographic
analysis for the Surface Coating of Metal
Cans source category are summarized in
Table 4 of this preamble. These results,
for various demographic groups, are
based on the estimated risk from actual
emissions levels for the population
living within 50 km of the facilities.
The results of the Surface Coating of
Metal Cans source category
demographic analysis indicate that
emissions from the source category
expose approximately 700 people to a
cancer risk at or above 1-in-1 million
and no one to a chronic noncancer
10843
TOSHI greater than 1. The percentages
of the population exposed to emissions
from the source category in three
demographic groups (White, Above
Poverty Level, and Over 25 with a High
School Diploma) are greater than their
respective nationwide percentages. The
methodology and the results of the
demographic analysis are presented in
more detail in the technical report titled
Risk and Technology Review—Analysis
of Demographic Factors for Populations
Living Near Surface Coating of Metal
Cans Source Category Operations, May
2018, in the Surface Coating of Metal
Cans Docket.
TABLE 4—SURFACE COATING OF METAL CANS SOURCE CATEGORY DEMOGRAPHIC RISK ANALYSIS RESULTS
Population with cancer
risk at or above 1-in-1
million due to surface
coating of metal cans
Nationwide
Total Population ...........................................................................................
317,746,049
Population with chronic
noncancer HI above 1
due to surface coating
of metal cans
700
0
62
38
92
8
0
0
12
0.8
18
7
0
0
4
4
0
0
0
0
14
86
4
96
0
0
14
86
4
96
0
0
0
0
White and Minority by Percent
White ............................................................................................................
Minority ........................................................................................................
Minority by Percent
African American .........................................................................................
Native American ..........................................................................................
Hispanic .......................................................................................................
Other and Multiracial ...................................................................................
Income by Percent
Below Poverty Level ....................................................................................
Above Poverty Level ....................................................................................
Education by Percent
Over 25 and without High School Diploma. ................................................
Over 25 and with a High School Diploma. ..................................................
Linguistically Isolated by Percent
Linguistically Isolated ...................................................................................
jbell on DSKJLSW7X2PROD with RULES2
2. Surface Coating of Metal Coil
The results of the demographic
analysis for the Surface Coating of Metal
Coil source category are summarized in
Table 5 of this preamble. These results,
for various demographic groups, are
based on the estimated risk from actual
emissions levels for the population
living within 50 km of the facilities.
The results of the Surface Coating of
Metal Coil source category demographic
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
6
analysis indicate that emissions from
the source category expose
approximately 19,000 people to a cancer
risk at or above 1-in-1 million and no
one is exposed to a chronic noncancer
TOSHI greater than 1. The percentages
of the population exposed to emissions
from the source category in three
demographic groups (White, African
American, and Over 25 and with a High
PO 00000
Frm 00017
Fmt 4701
Sfmt 4700
School Diploma) are greater than their
respective nationwide percentages.
The methodology and the results of
the demographic analysis are presented
in a technical report, Risk and
Technology Review—Analysis of
Demographic Factors for Populations
Living Near Surface Coating of Metal
Coil Source Category Operations, May
2017, available in the Surface Coating of
Metal Coil Docket.
E:\FR\FM\25FER2.SGM
25FER2
10844
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
TABLE 5—SURFACE COATING OF METAL COIL SOURCE CATEGORY DEMOGRAPHIC RISK ANALYSIS RESULTS
Population with cancer
risk at or above 1-in-1
million due to surface
coating of metal coil
Nationwide
Total Population ...........................................................................................
317,746,049
Population with chronic
noncancer HI above 1
due to surface coating
of metal coil
19,000
0
62
38
70
30
0
0
12
0.8
18
7
21
0.1
4
5
0
0
0
0
14
86
15
85
0
0
14
86
10
90
0
0
1
0
White and Minority by Percent
White ............................................................................................................
Minority ........................................................................................................
Minority by Percent
African American .........................................................................................
Native American ..........................................................................................
Hispanic .......................................................................................................
Other and Multiracial ...................................................................................
Income by Percent
Below Poverty Level ....................................................................................
Above Poverty Level ....................................................................................
Education by Percent
Over 25 and without High School Diploma .................................................
Over 25 and with a High School Diploma ...................................................
Linguistically Isolated by Percent
Linguistically Isolated ...................................................................................
G. What analysis of children’s
environmental health did we conduct?
This action is not subject to Executive
Order 13045 because it is not
economically significant as defined in
Executive Order 12866, and because the
EPA does not believe the environmental
health or safety risks addressed by this
action present a disproportionate risk to
children. This action’s health and risk
assessments are summarized in section
IV.A of this preamble and are further
documented in the Residual Risk
Assessment for the Surface Coating of
Metal Cans Source Category in Support
of the 2019 Risk and Technology Review
Proposed Rule, and the Residual Risk
Assessment for the Surface Coating of
Metal Coil Source Category in Support
of the 2019 Risk and Technology Review
Proposed Rule, in the Surface Coating of
Metal Cans and Surface Coating of Metal
Coil Dockets, respectively.
jbell on DSKJLSW7X2PROD with RULES2
VI. Statutory and Executive Order
Reviews
20:57 Feb 24, 2020
Jkt 250001
A. Executive Order 12866: Regulatory
Planning and Review and Executive
Order 13563: Improving Regulation and
Regulatory Review
This action is not a significant
regulatory action and was, therefore, not
submitted to Office of Management and
Budget (OMB) for review.
B. Executive Order 13771: Reducing
Regulations and Controlling Regulatory
Costs
This action is not an Executive Order
13771 regulatory action because this
action is not significant under Executive
Order 12866.
C. Paperwork Reduction Act (PRA)
The information collection activities
in this action have been submitted for
approval to OMB under the PRA, as
discussed for each source category
covered by this action in sections VI.C.1
and 2.
1. Surface Coating of Metal Cans
Additional information about these
statutes and Executive Orders can be
found at https://www.epa.gov/lawsregulations/laws-and-executive-orders.
VerDate Sep<11>2014
6
The Information Collection Request
(ICR) document that the EPA prepared
for this source category has been
assigned EPA ICR number 2079.08. You
can find a copy of the ICR document in
the Surface Coating of Metal Cans
Docket (Docket ID No. EPA–HQ–OAR–
2017–0684), and it is briefly
summarized here. The information
PO 00000
Frm 00018
Fmt 4701
Sfmt 4700
collection requirements are not enforced
until OMB approves them.
As part of the RTR for the Surface
Coating of Metal Cans NESHAP, the
EPA is not revising the emission limit
requirements. The EPA is revising the
SSM provisions of the rule and
requiring the use of electronic data
reporting for future performance test
data submittals, notifications, and
reports. This information is being
collected to assure compliance with 40
CFR part 63, subpart KKKK.
Respondents/affected entities:
Facilities performing surface coating of
metal cans.
Respondent’s obligation to respond:
Mandatory (40 CFR part 63, subpart
KKKK).
Estimated number of respondents: In
the 3 years after the amendments are
final, approximately five respondents
per year will be subject to the NESHAP
and no additional respondents are
expected to become subject to the
NESHAP during that period.
Frequency of response: The total
number of responses in year 1 is 15 and
in year 3 is one. Year 2 would have no
responses.
Total estimated burden: The average
annual information collection burden to
the five metal can facilities over the 3
years after the amendments are finalized
is estimated to be 54 hours (per year).
The average annual burden to the
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
jbell on DSKJLSW7X2PROD with RULES2
Agency over the 3 years after the
amendments are finalized is estimated
to be 23 hours (per year). Burden is
defined at 5 CFR 1320.3(b).
Total estimated cost: The average
annual labor cost to the metal can
facilities is estimated to be $6,200 in the
first 3 years after the amendments are
finalized. The average annual capital
and operation and maintenance (O&M)
cost is estimated to be $15,600 over this
period. The average annual Agency cost
over the first 3 years after the
amendments are finalized is estimated
to be $1,090.
2. Surface Coating of Metal Coil
The ICR document that the EPA
prepared for this source category has
been assigned EPA ICR number 1957.10.
You can find a copy of the ICR
document in the Surface Coating of
Metal Coil Docket (Docket ID No. EPA–
HQ–OAR–2017–0685), and it is briefly
summarized here. The information
collection requirements are not enforced
until OMB approves them.
As part of the RTR for the Surface
Coating of Metal Coil NESHAP, the EPA
is not revising the emission limit
requirements. The EPA is revising the
SSM provisions of the rule and
requiring the use of electronic data
reporting for future performance test
data submittals, notifications, and
reports. This information is being
collected to assure compliance with 40
CFR part 63, subpart SSSS.
Respondents/affected entities:
Facilities performing surface coating of
metal coil.
Respondent’s obligation to respond:
Mandatory (40 CFR part 63, subpart
SSSS).
Estimated number of respondents: In
the 3 years after the amendments are
finalized, approximately 48 respondents
per year will be subject to the NESHAP
and no additional respondents are
expected to become subject to the
NESHAP during that period.
Frequency of response: The total
number of responses in year 1 is 144
and in year 3 is 69. Year 2 would have
no responses.
Total estimated burden: The average
annual burden to the 48 metal coil
coating facilities over the 3 years after
the amendments are finalized is
estimated to be 738 hours (per year).
The average annual burden to the
Agency over the 3 years after the
amendments are finalized is estimated
to be 179 hours (per year). Burden is
defined at 5 CFR 1320.3(b).
Total estimated cost: The average
annual cost to the 48 metal coil coating
facilities is estimated to be $85,000 in
labor costs and $186,000 in capital and
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
O&M costs in the first 3 years after the
amendments are finalized. The average
annual Agency cost over the first 3 years
after the amendments are finalized is
estimated to be $8,530.
An agency may not conduct or
sponsor, and a person is not required to
respond to, a collection of information
unless it displays a currently valid OMB
control number. The OMB control
numbers for the EPA’s regulations in 40
CFR are listed in 40 CFR part 9. When
OMB approves the ICRs, the Agency
will announce that approval in the
Federal Register and publish a technical
amendment to 40 CFR part 9 to display
the OMB control number for the
approved information collection actions
contained in the final rule.
D. Regulatory Flexibility Act (RFA)
I certify that this action will not have
a significant economic impact on a
substantial number of small entities
under the RFA. The eleven small
entities that are subject to the
requirements of this action are small
businesses. The Agency has determined
that the seven ultimate owners of these
eleven affected small entities (21
percent of the facilities affected by this
action) so impacted may experience an
impact of 0.0029 to 0.77 percent of
annual sales revenues per ultimate
owner. Details of this analysis are
described in section V.D above and in
the economic impact memorandums
located in the dockets for this action.
E. Unfunded Mandates Reform Act
(UMRA)
This action does not contain an
unfunded mandate of $100 million or
more as described in UMRA, 2 U.S.C.
1531–1538, and does not significantly or
uniquely affect small governments. The
action imposes no enforceable duty on
any state, local, or tribal governments or
the private sector.
F. Executive Order 13132: Federalism
This action does not have federalism
implications. It will not have substantial
direct effects on the states, on the
relationship between the national
government and the states, or on the
distribution of power and
responsibilities among the various
levels of government.
G. Executive Order 13175: Consultation
and Coordination With Indian Tribal
Governments
This action does not have tribal
implications as specified in Executive
Order 13175. No tribal facilities are
known to be engaged in any of the
industries that would be affected by this
action (metal can surface coating and
PO 00000
Frm 00019
Fmt 4701
Sfmt 4700
10845
metal coil surface coating). Thus,
Executive Order 13175 does not apply
to this action.
H. Executive Order 13045: Protection of
Children From Environmental Health
Risks and Safety Risks
This action is not subject to Executive
Order 13045 because it is not
economically significant as defined in
Executive Order 12866, and because the
EPA does not believe the environmental
health or safety risks addressed by this
action present a disproportionate risk to
children. This action’s health and risk
assessments are contained in sections
III.A and C, IV.A.1 and 2, IV.B.1 and 2,
and IV.C.1 and 2 of the proposal
preamble (84 FR 25904, June 4, 2019)
and are further documented in the
Residual Risk Assessment for the
Surface Coating of Metal Cans Source
Category in Support of the 2019 Risk
and Technology Review Proposed Rule
and the Residual Risk Assessment for
the Surface Coating of Metal Coil Source
Category in Support of the 2019 Risk
and Technology Review Proposed Rule
in the Surface Coating of Metal Cans
Docket and the Surface Coating of Metal
Coil Docket, respectively.
I. Executive Order 13211: Actions
Concerning Regulations That
Significantly Affect Energy Supply,
Distribution, or Use
This action is not subject to Executive
Order 13211 because it is not a
significant regulatory action under
Executive Order 12866.
J. National Technology Transfer and
Advancement Act (NTTAA) and 1 CFR
Part 51
This rulemaking involves technical
standards. The EPA amended the
Surface Coating of Metal Coil NESHAP
in this action to provide owners and
operators with the option of conducting
two new methods: EPA Method 18 of
appendix A to 40 CFR part 60,
‘‘Measurement of Gaseous Organic
Compound Emissions by Gas
Chromatography,’’ to measure and
subtract methane emissions from
measured total gaseous organic mass
emissions as carbon, and ASTM Method
D1475–13, ‘‘Standard Test Method for
Density of Liquid Coatings, Inks, and
Related Products.’’ We are incorporating
ASTM Method D1475–13 by reference.
We are adding these two standards to
the Surface Coating of Metal Coil
NESHAP only, as these methods are
already provided in the Surface Coating
of Metal Cans NESHAP.
The EPA is also amending the Surface
Coating of Metal Cans NESHAP to
update three ASTM test methods and
E:\FR\FM\25FER2.SGM
25FER2
jbell on DSKJLSW7X2PROD with RULES2
10846
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
amend the Surface Coating of Metal Coil
NESHAP to update two ASTM test
methods. We are updating ASTM
Method D1475–90, ‘‘Standard Test
Method for Density of Liquid Coatings,
Inks, and Related Products,’’ in the
Surface Coating of Metal Cans NESHAP
by incorporating by reference ASTM
Method D1475–13. The updated
version, ASTM Method D1475–13,
clarifies units of measure and reduces
the number of determinations required.
We are updating ASTM Method D2697–
86 (1998), ‘‘Standard Test Method for
Volume Nonvolatile Matter in Clear or
Pigmented Coatings,’’ in both the
Surface Coating of Metal Cans and the
Surface Coating of Metal Coil NESHAP
by incorporating by reference ASTM
D2697–03 (2014), which is the updated
version of the previously approved
method. We are also updating ASTM
Method D6093–97 (2003), ‘‘Standard
Test Method for Percent Volume
Nonvolatile Matter in Clear or
Pigmented Coatings Using Helium Gas
Pycnometer,’’ in both the Surface
Coating of Metal Cans and the Surface
Coating of Metal Coil NESHAP by
incorporating by reference ASTM
D6093–97 (2016), which is the updated
version of the previously approved
method. ASTM D2697–03 (2014) is a
test method that can be used to
determine the volume of nonvolatile
matter in clear and pigmented coatings
and ASTM D6093–97 (2016) is a test
method that can be used to determine
the percent volume of nonvolatile
matter in clear and pigmented coatings.
For the Surface Coating of Metal Cans
NESHAP and the Surface Coating of
Metal Coil NESHAP, we are
incorporating by reference ASTM
D2369–10 (2015), ‘‘Test Method for
Volatile Content of Coatings,’’ as an
alternative to EPA Method 24 for the
determination of the volatiles emitted
by the surface coatings. The test method
determines the weight percent volatile
content of solvent borne and water
borne coatings under specified test
conditions. It is viable for coatings
wherein one or more parts may, at
ambient conditions, contain liquid coreactants that are volatile until a
chemical reaction has occurred with
another component of a multi-package
system.
For the Surface Coating of Metal Cans
and the Surface Coating of Metal Coil
NESHAP, we are incorporating by
reference ASTM D2111–10 (2015),
‘‘Standard Test Methods for Specific
Gravity and Density of Halogenated
Organic Solvents and Their
Admixtures,’’ for the determination of
the specific gravity of halogenated
organic solvents and solvent admixtures
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
in surface coatings. ASTM D2111–10
(2015) includes three test methods to
measure specific gravity using suitable
apparatus (i.e., a hydrometer, a
pycnometer, or an electronic
densitometer), procedures, and details
underlying the interpretation of test data
and the selection of numerical limits.
The ASTM standards are available
from the American Society for Testing
and Materials (ASTM), 100 Barr Harbor
Drive, Post Office Box C700, West
Conshohocken, PA 19428–2959. See
https://www.astm.org/.
The EPA decided not to include
certain other VCS; these methods are
impractical as alternatives because of
the lack of equivalency, documentation,
validation date, and other important
technical and policy considerations.
The search and review results have been
documented and are in the memoranda
titled Voluntary Consensus Standard
Results for Surface Coating of Metal
Cans, August 16, 2018, and Voluntary
Consensus Standard Results for Surface
Coating of Metal Coil, August 16, 2018,
in the Surface Coating of Metal Cans
Docket and the Surface Coating of Metal
Coil Docket, respectively.
Under 40 CFR 63.7(f) and 40 CFR
63.8(f) of subpart A of the General
Provisions, a source may apply to the
EPA for permission to use alternative
test methods or alternative monitoring
requirements in place of any required
testing methods, performance
specifications, or procedures in the final
rule or any amendments.
K. Executive Order 12898: Federal
Actions To Address Environmental
Justice in Minority Populations and
Low-Income Populations
The EPA believes that this action does
not have disproportionately high and
adverse human health or environmental
effects on minority populations, lowincome populations, and/or indigenous
peoples, as specified in Executive Order
12898 (59 FR 7629, February 16, 1994)
because it does not significantly affect
the level of protection provided to
human health or the environment. The
documentation for this decision is
contained in section IV of this preamble
and the technical reports titled Risk and
Technology Review—Analysis of
Demographic Factors for Populations
Living Near Surface Coating of Metal
Cans Source Category Operations, May
2018, and Risk and Technology
Review—Analysis of Demographic
Factors for Populations Living Near
Surface Coating of Metal Coil Source
Category Operations, May 2018, which
are available in the Surface Coating of
Metal Cans and Surface Coating of Metal
Coil Dockets, respectively.
PO 00000
Frm 00020
Fmt 4701
Sfmt 4700
L. Congressional Review Act (CRA)
This action is subject to the CRA, and
the EPA will submit a rule report to
each House of the Congress and to the
Comptroller General of the United
States. This action is not a ‘‘major rule’’
as defined by 5 U.S.C. 804(2)
List of Subjects in 40 CFR Part 63
Environmental protection,
Administrative practice and procedures,
Air pollution control, Hazardous
substances, Incorporation by reference,
Surface Coating of Metal Cans, Surface
Coating of Metal Coil, Reporting and
recordkeeping requirements, Appendix
A.
Dated: December 20, 2019.
Andrew R. Wheeler,
Administrator.
For the reasons stated in the
preamble, the EPA amends 40 CFR part
63 as follows:
PART 63—NATIONAL EMISSION
STANDARDS FOR HAZARDOUS AIR
POLLUTANTS FOR SOURCE
CATEGORIES
1. The authority citation for part 63
continues to read as follows:
■
Authority: 42 U.S.C. 7401 et seq.
Subpart A—General Provisions
2. Section 63.14 is amended by
revising paragraphs (h)(13), (21), (26),
(29), (30), (78) and (79) to read as
follows:
■
§ 63.14
Incorporations by reference.
*
*
*
*
*
(h) * * *
(13) ASTM D1475–13, Standard Test
Method for Density of Liquid Coatings,
Inks, and Related Products, approved
November 1, 2013, IBR approved for
§§ 63.3521(c), 63.3531(c), 63.4141(b)
and (c), 63.4741(b) and (c), 63.4751(c),
63.4941(b) and (c), and 63.5160(c).
*
*
*
*
*
(21) ASTM D2111–10 (Reapproved
2015), Standard Test Methods for
Specific Gravity and Density of
Halogenated Organic Solvents and Their
Admixtures, approved June 1, 2015, IBR
approved for §§ 63.3531(c), 63.4141(b)
and (c), 63.4741(a), and 63.5160(c).
*
*
*
*
*
(26) ASTM D2369–10 (Reapproved
2015)e, Standard Test Method for
Volatile Content of Coatings, approved
June 1, 2015, IBR approved for
§§ 63.3521(a), 63.3541(i), 63.4141(a) and
(b), 63.4161(h), 63.4321(e), 63.4341(e),
63.4351(d), 63.4741(a), 63.4941(a) and
(b), 63.4961(j), and 63.5160(b).
*
*
*
*
*
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
(29) ASTM D2697–86 (Reapproved
1998), Standard Test Method for
Volume Nonvolatile Matter in Clear or
Pigmented Coatings, IBR approved for
§§ 63.3161(f), 63.3941(b), 63.4141(b),
63.4741(b), and 63.4941(b).
(30) ASTM D2697–03 (Reapproved
2014), Standard Test Method for
Volume Nonvolatile Matter in Clear or
Pigmented Coatings, approved July 1,
2014, IBR approved for §§ 63.3521(b),
63.4141(b), 63.4741(a) and (b),
63.4941(b), and 63.5160(c).
*
*
*
*
*
(78) ASTM D6093–97 (Reapproved
2003), Standard Test Method for Percent
Volume Nonvolatile Matter in Clear or
Pigmented Coatings Using a Helium Gas
Pycnometer, IBR approved for
§§ 63.3161 and 63.3941.
(79) ASTM D6093–97 (Reapproved
2016), Standard Test Method for Percent
Volume Nonvolatile Matter in Clear or
Pigmented Coatings Using a Helium Gas
Pycnometer, Approved December 1,
2016, IBR approved for §§ 63.3521(b),
63.4141(b), 63.4741(a) and (b),
63.4941(b), and 63.5160(c).
*
*
*
*
*
Subpart KKKK—National Emission
Standards for Hazardous Air
Pollutants: Surface Coating of Metal
Cans
3. Section 63.3481 is amended by
revising paragraph (c)(5) to read as
follows:
■
§ 63.3481
Am I subject to this subpart?
*
*
*
*
*
(c) * * *
(5) Surface coating of metal pails,
buckets, and drums. Subpart MMMM of
this part covers surface coating of all
miscellaneous metal parts and products
not explicitly covered by another
subpart.
■ 4. Section 63.3492 is amended by
revising paragraph (b) to read as follows:
§ 63.3492
meet?
What operating limits must I
jbell on DSKJLSW7X2PROD with RULES2
*
*
*
*
*
(b) For any controlled coating
operation(s) on which you use the
emission rate with add-on controls
option or the control efficiency/outlet
concentration option, except those for
which you use a solvent recovery
system and conduct a liquid-liquid
material balance according to
§ 63.3541(i), you must meet the
operating limits specified in Table 4 to
this subpart. Those operating limits
apply to the emission capture and
control systems for the coating
operation(s) used for purposes of
complying with this subpart. You must
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
establish the operating limits during the
performance tests required in § 63.3540
or § 63.3550 according to the
requirements in § 63.3546 or § 63.3556.
You must meet the operating limits
established during the most recent
performance tests required in § 63.3540
or § 63.3550 at all times after they have
been established during the
performance test.
*
*
*
*
*
■ 5. Section 63.3500 is amended by
revising paragraphs (a)(1), (b), and (c) to
read as follows:
§ 63.3500 What are my general
requirements for complying with this
subpart?
(a) * * *
(1) Any coating operation(s) for which
you use the compliant material option
or the emission rate without add-on
controls option, as specified in
§ 63.3491(a) and (b), must be in
compliance with the applicable
emission limit in § 63.3490 at all times.
*
*
*
*
*
(b) Before August 24, 2020, you must
always operate and maintain your
affected source, including all air
pollution control and monitoring
equipment you use for purposes of
complying with this subpart, according
to the provisions in § 63.6(e)(1)(i). On
and after August 24, 2020, at all times,
the owner or operator must operate and
maintain any affected source, including
associated air pollution control
equipment and monitoring equipment,
in a manner consistent with safety and
good air pollution control practices for
minimizing emissions. The general duty
to minimize emissions does not require
the owner or operator to make any
further efforts to reduce emissions if
levels required by the applicable
standard have been achieved.
Determination of whether a source is
operating in compliance with operation
and maintenance requirements will be
based on information available to the
Administrator that may include, but is
not limited to, monitoring results,
review of operation and maintenance
procedures, review of operation and
maintenance records, and inspection of
the affected source.
(c) Before August 24, 2020, if your
affected source uses an emission capture
system and add-on control device for
purposes of complying with this
subpart, you must develop a written
startup, shutdown, and malfunction
plan (SSMP) according to the provisions
in § 63.6(e)(3). The plan must address
startup, shutdown, and corrective
actions in the event of a malfunction of
the emission capture system or the add-
PO 00000
Frm 00021
Fmt 4701
Sfmt 4700
10847
on control device. The plan must also
address any coating operation
equipment that may cause increased
emissions or that would affect capture
efficiency if the process equipment
malfunctions, such as conveyors that
move parts among enclosures. On and
after August 24, 2020, the SSMP is not
required.
■ 6. Section 63.3511 is amended by:
■ a. Revising paragraphs (a)(4), (a)(5)
introductory text, (a)(5)(i), and (a)(5)(iv);
■ b. Adding paragraph (a)(5)(v);
■ c. Revising paragraph (a)(6)
introductory text and (a)(6)(iii);
■ d. Adding paragraph (a)(6)(iv);
■ e. Revising paragraphs (a)(7)
introductory text, (a)(7)(iii), (a)(7)(vi)
through (viii), (a)(7)(x), and (a)(7)(xiii)
and (xiv);
■ f. Adding paragraph (a)(7)(xv);
■ g. Revising paragraphs (a)(8)
introductory text, (a)(8)(i), (a)(8)(iv)
through (vi), (a)(8)(viii), and (a)(8)(xi)
and (xii);
■ f. Adding paragraph (a)(8)(xiii);
■ g. Revising paragraph (c) introductory
text; and
■ h. Adding paragraphs (d) through (h).
The revisions and additions read as
follows:
§ 63.3511
What reports must I submit?
(a) * * *
(4) No deviations. If there were no
deviations from the emission limits,
operating limits, or work practice
standards in §§ 63.3490, 63.3492, and
63.3493 that apply to you, the
semiannual compliance report must
include a statement that there were no
deviations from the emission limitations
during the reporting period. If you used
the emission rate with add-on controls
option or the control efficiency/outlet
concentration option and there were no
periods during which the continuous
parameter monitoring systems (CPMS)
were out of control as specified in
§ 63.8(c)(7), the semiannual compliance
report must include a statement that
there were no periods during which the
CPMS were out of control during the
reporting period.
(5) Deviations: Compliant material
option. If you used the compliant
material option and there was a
deviation from the applicable emission
limit in § 63.3490, the semiannual
compliance report must contain the
information in paragraphs (a)(5)(i)
through (v) of this section.
(i) Identification of each coating used
that deviated from the emission limit,
each thinner used that contained
organic HAP, and the date, time, and
duration each was used.
*
*
*
*
*
E:\FR\FM\25FER2.SGM
25FER2
jbell on DSKJLSW7X2PROD with RULES2
10848
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
(iv) Before August 24, 2020, a
statement of the cause of each deviation.
On and after August 24, 2020, a
statement of the cause of each deviation
(including unknown cause, if
applicable).
(v) On and after August 24, 2020, the
number of deviations and, for each
deviation, a list of the affected source or
equipment, an estimate of the quantity
of each regulated pollutant emitted over
any applicable emission limit in
§ 63.3490, a description of the method
used to estimate the emissions, and the
actions you took to minimize emissions
in accordance with § 63.3500(b).
(6) Deviations: Emission rate without
add-on controls option. If you used the
emission rate without add-on controls
option and there was a deviation from
the applicable emission limit in
§ 63.3490, the semiannual compliance
report must contain the information in
paragraphs (a)(6)(i) through (iv) of this
section.
*
*
*
*
*
(iii) Before August 24, 2020, a
statement of the cause of each deviation.
On and after August 24, 2020, a
statement of the cause of each deviation
(including unknown cause, if
applicable).
(iv) On and after August 24, 2020, the
number of deviations, date, time,
duration, a list of the affected source or
equipment, an estimate of the quantity
of each regulated pollutant emitted over
any applicable emission limit in
§ 63.3490, a description of the method
used to estimate the emissions, and the
actions you took to minimize emissions
in accordance with § 63.3500(b).
(7) Deviations: Emission rate with
add-on controls option. If you used the
emission rate with add-on controls
option and there was a deviation from
the applicable emission limit in
§ 63.3490 or the applicable operating
limit(s) in Table 4 to this subpart
(including any periods when emissions
bypassed the add-on control device and
were diverted to the atmosphere), before
August 24, 2020, the semiannual
compliance report must contain the
information in paragraphs (a)(7)(i)
through (xiv) of this section. That
includes periods of startup, shutdown,
and malfunction during which
deviations occurred. On and after
August 24, 2020, the semiannual
compliance report must contain the
information in paragraphs (a)(7)(i)
through (xii), (a)(7)(xiv), and (a)(7)(xv)
of this section. If you use the emission
rate with add-on controls option and
there was a deviation from the
applicable work practice standards in
§ 63.3493(b), the semiannual
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
compliance report must contain the
information in paragraph (a)(7)(xiii) of
this section.
*
*
*
*
*
(iii) The date and time that each
malfunction of the capture system or
add-on control devices started and
stopped.
*
*
*
*
*
(vi) Before August 24, 2020, the date
and time that each CPMS was
inoperative, except for zero (low-level)
and high-level checks. On and after
August 24, 2020, the number of
instances that the CPMS was
inoperative, and for each instance,
except for zero (low-level) and highlevel checks, the date, time, and
duration that the CPMS was inoperative;
the cause (including unknown cause)
for the CPMS being inoperative; and the
actions you took to minimize emissions
in accordance with § 63.3500(b).
(vii) Before August 24, 2020, the date,
time, and duration that each CPMS was
out of control, including the information
in § 63.8(c)(8). On and after August 24,
2020, the number of instances that the
CPMS was out of control as specified in
§ 63.8(c)(7) and, for each instance, the
date, time, and duration that the CPMS
was out-of-control; the cause (including
unknown cause) for the CPMS being
out-of-control; and descriptions of
corrective actions taken.
(viii) Before August 24, 2020, the date
and time period of each deviation from
an operating limit in Table 4 to this
subpart; date and time period of any
bypass of the add-on control device; and
whether each deviation occurred during
a period of startup, shutdown, or
malfunction or during another period.
On and after August 24, 2020, the
number of deviations from an operating
limit in Table 4 to this subpart and, for
each deviation, the date, time, and
duration of each deviation; the date,
time, and duration of any bypass of the
add-on control device.
*
*
*
*
*
(x) Before August 24, 2020, a
breakdown of the total duration of the
deviations from the operating limits in
Table 4 to this subpart and bypasses of
the add-on control device during the
semiannual reporting period into those
that were due to startup, shutdown,
control equipment problems, process
problems, other known causes, and
other unknown causes. On and after
August 24, 2020, a breakdown of the
total duration of the deviations from the
operating limits in Table 4 to this
subpart and bypasses of the add-on
control device during the semiannual
reporting period into those that were
due to control equipment problems,
PO 00000
Frm 00022
Fmt 4701
Sfmt 4700
process problems, other known causes,
and other unknown causes.
*
*
*
*
*
(xiii) Before August 24, 2020, for each
deviation from the work practice
standards, a description of the
deviation; the date, and time period of
the deviation; and the actions you took
to correct the deviation. On and after
August 24, 2020, for deviations from the
work practice standards, the number of
deviations, and, for each deviation, the
information in paragraphs (a)(7)(xiii)(A)
and (B) of this section:
(A) A description of the deviation; the
date, time, and duration of the
deviation; and the actions you took to
minimize emissions in accordance with
§ 63.3500(b).
(B) The description required in
paragraph (a)(7)(xiii)(A) of this section
must include a list of the affected
sources or equipment for which a
deviation occurred and the cause of the
deviation (including unknown cause, if
applicable.
(xiv) Before August 24, 2020, a
statement of the cause of each deviation.
On and after August 24, 2020, for
deviations from an emission limit in
§ 63.3490 or an operating limit in Table
4 to this subpart, a statement of the
cause of each deviation (including
unknown cause, if applicable) and the
actions you took to minimize emissions
in accordance with § 63.3500(b).
(xv) On and after August 24, 2020, for
each deviation from an emission limit in
§ 63.3490 or operating limit in Table 4
to this subpart, a list of the affected
sources or equipment for which a
deviation occurred, an estimate of the
quantity of each regulated pollutant
emitted over any emission limit in
§ 63.3490 or operating limit in Table 4
to this subpart, and a description of the
method used to estimate the emissions.
(8) Deviations: control efficiency/
outlet concentration option. If you used
the control efficiency/outlet
concentration option, and there was a
deviation from the applicable emission
limit in § 63.3490 or the applicable
operating limit(s) in Table 4 to this
subpart (including any periods when
emissions bypassed the add-on control
device and were diverted to the
atmosphere), before August 24, 2020,
the semiannual compliance report must
contain the information in paragraphs
(a)(8)(i) through (xii) of this section.
This includes periods of startup,
shutdown, and malfunction during
which deviations occurred. On and after
August 24, 2020, the semiannual
compliance report must specify the
number of deviations during the
compliance period and contain the
E:\FR\FM\25FER2.SGM
25FER2
jbell on DSKJLSW7X2PROD with RULES2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
information in paragraphs (a)(8)(i)
through (x), (xii), and (xiii) of this
section. If you use the control
efficiency/outlet concentration option
and there was a deviation from the
applicable work practice standards in
§ 63.3493(b), the semiannual
compliance report must contain the
information in paragraph (a)(8)(xi) of
this section.
(i) The date and time that each
malfunction of the capture system or
add-on control devices started and
stopped.
*
*
*
*
*
(iv) Before August 24, 2020, the date
and time that each CPMS was
inoperative, except for zero (low-level)
and high-level checks. On and after
August 24, 2020, for each instance that
the CPMS was inoperative, except for
zero (low-level) and high-level checks,
the date, time, and duration that the
CPMS was inoperative; the cause
(including unknown cause) for the
CPMS being inoperative; and the actions
you took to minimize emissions in
accordance with § 63.3500(b).
(v) For each instance that the CPMS
was out of control as specified in
§ 63.8(c)(7), the date, time, and duration
that the CPMS was out of control; the
cause (including unknown cause) for
the CPMS being out of control; and the
actions you took to minimize emissions
in accordance with § 63.3500(b).
(vi) Before August 24, 2020, the date
and time period of each deviation from
an operating limit in Table 4 to this
subpart; date and time of any bypass of
the add-on control device; and whether
each deviation occurred during a period
of startup, shutdown, or malfunction or
during another period. On and after
August 24, 2020, the date, time, and
duration of each deviation from an
operating limit in Table 4 to this
subpart; and the date, time, and
duration of any bypass of the add-on
control device.
*
*
*
*
*
(viii) Before August 24, 2020, a
breakdown of the total duration of the
deviations from the operating limits in
Table 4 to this subpart and bypasses of
the add-on control device during the
semiannual reporting period into those
that were due to startup, shutdown,
control equipment problems, process
problems, other known causes, and
other unknown causes. On and after
August 24, 2020, a breakdown of the
total duration of the deviations from the
operating limits in Table 4 to this
subpart and bypasses of the add-on
control device during the semiannual
reporting period into those that were
due to control equipment problems,
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
process problems, other known causes,
and other unknown causes.
*
*
*
*
*
(xi) Before August 24, 2020, for each
deviation from the work practice
standards, a description of the
deviation; the date and time period of
the deviation; and the actions you took
to correct the deviation. On and after
August 24, 2020, for deviations from the
work practice standards in § 63.3493(b),
the number of deviations, and, for each
deviation, the information in paragraphs
(a)(8)(xiii)(A) and (B) of this section:
(A) A description of the deviation; the
date, time, and duration of the
deviation; and the actions you took to
minimize emissions in accordance with
§ 63.3500(b).
(B) The description required in
paragraph (a)(8)(xi)(A) of this section
must include a list of the affected
sources or equipment for which a
deviation occurred and the cause of the
deviation (including unknown cause, if
applicable).
(xii) Before August 24, 2020, a
statement of the cause of each deviation.
On and after August 24, 2020, for
deviations from an emission limit in
§ 63.3490 or operating limit in Table 4
to this subpart, a statement of the cause
of each deviation (including unknown
cause, if applicable).
(xiii) On and after August 24, 2020,
for each deviation from an emission
limit in § 63.3490 or operating limit in
Table 4 to this subpart, a list of the
affected sources or equipment for which
a deviation occurred, an estimate of the
quantity of each regulated pollutant
emitted over any emission limit in
§ 63.3490, and a description of the
method used to estimate the emissions.
*
*
*
*
*
(c) Startup, shutdown, malfunction
reports. Before August 24, 2020, if you
used the emission rate with add-on
controls option or the control efficiency/
outlet concentration option and you had
a startup, shutdown, or malfunction
during the semiannual reporting period,
you must submit the reports specified in
paragraphs (c)(1) and (2) of this section.
On and after August 24, 2020, the
reports specified in paragraphs (c)(1)
and (2) of this section are not required.
*
*
*
*
*
(d) On and after August 24, 2020, you
must submit the results of the
performance test required in §§ 63.3540
and 63.3550 following the procedure
specified in paragraphs (d)(1) through
(3) of this section.
(1) For data collected using test
methods supported by the EPA’s
Electronic Reporting Tool (ERT) as
listed on the EPA’s ERT website
PO 00000
Frm 00023
Fmt 4701
Sfmt 4700
10849
(https://www.epa.gov/electronicreporting-air-emissions/electronicreporting-tool-ert) at the time of the test,
you must submit the results of the
performance test to the EPA via the
Compliance and Emissions Data
Reporting Interface (CEDRI). The CEDRI
interface can be accessed through the
EPA’s Central Data Exchange (CDX)
(https://cdx.epa.gov/). Performance test
data must be submitted in a file format
generated through the use of the EPA’s
ERT or an alternate electronic file
format consistent with the extensible
markup language (XML) schema listed
on the EPA’s ERT website.
(2) For data collected using test
methods that are not supported by the
EPA’s ERT as listed on the EPA’s ERT
website at the time of the test, you must
submit the results of the performance
test in portable document format (PDF)
using the attachment module of the
ERT.
(3) If you claim that some of the
performance test information being
submitted under paragraph (d)(1) of this
section is confidential business
information (CBI), you must submit a
complete file generated through the use
of the EPA’s ERT or an alternate
electronic file consistent with the XML
schema listed on the EPA’s ERT
website, including information claimed
to be CBI, on a compact disc, flash
drive, or other commonly used
electronic storage medium to the EPA.
The electronic medium must be clearly
marked as CBI and mailed to U.S. EPA/
OAPQS/CORE CBI Office, Attention:
Group Leader, Measurement Policy
Group, MD C404–02, 4930 Old Page Rd.,
Durham, NC 27703. The same ERT or
alternate file with the CBI omitted must
be submitted to the EPA via the EPA’s
CDX as described in paragraph (c)(1) of
this section.
(e) On and after August 24, 2020, the
owner or operator shall submit the
initial notifications required in § 63.9(b)
and the notification of compliance
status required in §§ 63.9(h) and
63.3510(c) to the EPA via the CEDRI.
The CEDRI interface can be accessed
through the EPA’s CDX (https://
cdx.epa.gov). The owner or operator
must upload to CEDRI an electronic
copy of each applicable notification in
PDF. The applicable notification must
be submitted by the deadline specified
in this subpart, regardless of the method
in which the reports are submitted.
Owners or operators who claim that
some of the information required to be
submitted via CEDRI is CBI shall submit
a complete report generated using the
appropriate form in CEDRI or an
alternate electronic file consistent with
the XML schema listed on the EPA’s
E:\FR\FM\25FER2.SGM
25FER2
jbell on DSKJLSW7X2PROD with RULES2
10850
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
CEDRI website, including information
claimed to be CBI, on a compact disc,
flash drive, or other commonly used
electronic storage medium to the EPA.
The electronic medium shall be clearly
marked as CBI and mailed to U.S. EPA/
OAQPS/CORE CBI Office, Attention:
Group Leader, Measurement Policy
Group, MD C404–02, 4930 Old Page Rd.,
Durham, NC 27703. The same file with
the CBI omitted shall be submitted to
the EPA via the EPA’s CDX as described
earlier in this paragraph.
(f) On and after March 25, 2021, or
once the reporting template has been
available on the CEDRI website for 1
year, whichever date is later, the owner
or operator shall submit the semiannual
compliance report required in paragraph
(a) of this section to the EPA via the
CEDRI. The CEDRI interface can be
accessed through the EPA’s CDX
(https://cdx.epa.gov). The owner or
operator must use the appropriate
electronic template on the CEDRI
website for this subpart (https://
www.epa.gov/electronic-reporting-airemissions/compliance-and-emissionsdata-reporting-interface-cedri). The date
report templates become available will
be listed on the CEDRI website. If the
reporting form for the semiannual
compliance report specific to this
subpart is not available in CEDRI at the
time that the report is due, you must
submit the report to the Administrator
at the appropriate addresses listed in
§ 63.13. Once the form has been
available in CEDRI for 1 year, you must
begin submitting all subsequent reports
via CEDRI. The reports must be
submitted by the deadlines specified in
this subpart, regardless of the method in
which the reports are submitted.
Owners or operators who claim that
some of the information required to be
submitted via CEDRI is CBI shall submit
a complete report generated using the
appropriate form in CEDRI, including
information claimed to be CBI, on a
compact disc, flash drive, or other
commonly used electronic storage
medium to the EPA. The electronic
medium shall be clearly marked as CBI
and mailed to U.S. EPA/OAQPS/CORE
CBI Office, Attention: Group Leader,
Measurement Policy Group, MD C404–
02, 4930 Old Page Rd., Durham, NC
27703. The same file with the CBI
omitted shall be submitted to the EPA
via the EPA’s CDX as described earlier
in this paragraph.
(g) If you are required to electronically
submit a report through the CEDRI in
the EPA’s CDX, you may assert a claim
of the EPA system outage for failure to
timely comply with the reporting
requirement. To assert a claim of the
EPA system outage, you must meet the
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
requirements outlined in paragraphs
(g)(1) through (7) of this section.
(1) You must have been or will be
precluded from accessing CEDRI and
submitting a required report within the
time prescribed due to an outage of
either the EPA’s CEDRI or CDX systems.
(2) The outage must have occurred
within the period of time beginning five
business days prior to the date that the
submission is due.
(3) The outage may be planned or
unplanned.
(4) You must submit notification to
the Administrator in writing as soon as
possible following the date you first
knew, or through due diligence should
have known, that the event may cause
or caused a delay in reporting.
(5) You must provide to the
Administrator a written description
identifying:
(i) The date(s) and time(s) when CDX
or CEDRI was accessed and the system
was unavailable;
(ii) A rationale for attributing the
delay in reporting beyond the regulatory
deadline to the EPA system outage;
(iii) Measures taken or to be taken to
minimize the delay in reporting; and
(iv) The date by which you propose to
report, or if you have already met the
reporting requirement at the time of the
notification, the date you reported.
(6) The decision to accept the claim
of the EPA system outage and allow an
extension to the reporting deadline is
solely within the discretion of the
Administrator.
(7) In any circumstance, the report
must be submitted electronically as
soon as possible after the outage is
resolved.
(h) If you are required to
electronically submit a report through
CEDRI in the EPA’s CDX, you may
assert a claim of force majeure for
failure to timely comply with the
reporting requirement. To assert a claim
of force majeure, you must meet the
requirements outlined in paragraphs
(h)(1) through (5) of this section.
(1) You may submit a claim if a force
majeure event is about to occur, occurs,
or has occurred or there are lingering
effects from such an event within the
period of time beginning five business
days prior to the date the submission is
due. For the purposes of this section, a
force majeure event is defined as an
event that will be or has been caused by
circumstances beyond the control of the
affected facility, its contractors, or any
entity controlled by the affected facility
that prevents you from complying with
the requirement to submit a report
electronically within the time period
prescribed. Examples of such events are
acts of nature (e.g., hurricanes,
PO 00000
Frm 00024
Fmt 4701
Sfmt 4700
earthquakes, or floods), acts of war or
terrorism, or equipment failure or safety
hazard beyond the control of the
affected facility (e.g., large scale power
outage).
(2) You must submit notification to
the Administrator in writing as soon as
possible following the date you first
knew, or through due diligence should
have known, that the event may cause
or has caused a delay in reporting.
(3) You must provide to the
Administrator:
(i) A written description of the force
majeure event;
(ii) A rationale for attributing the
delay in reporting beyond the regulatory
deadline to the force majeure event;
(iii) Measures taken or to be taken to
minimize the delay in reporting; and
(iv) The date by which you propose to
report, or if you have already met the
reporting requirement at the time of the
notification, the date you reported.
(4) The decision to accept the claim
of force majeure and allow an extension
to the reporting deadline is solely
within the discretion of the
Administrator.
(5) In any circumstance, the reporting
must occur as soon as possible after the
force majeure event occurs.
■ 7. Section 63.3512 is amended by
revising paragraphs (i), (j) introductory
text, and (j)(1) and (2) to read as follows:
§ 63.3512
What records must I keep?
*
*
*
*
*
(i) Before August 24, 2020, a record of
the date, time, and duration of each
deviation. On and after August 24, 2020,
for each deviation from an emission
limitation reported under
§ 63.3511(a)(5) through (8), a record of
the information specified in paragraphs
(i)(1) through (4) of this section, as
applicable.
(1) The date, time, and duration of the
deviation, as reported under
§ 63.3511(a)(5) through (8).
(2) A list of the affected sources or
equipment for which the deviation
occurred and the cause of the deviation,
as reported under § 63.3511(a)(5)
through (8).
(3) An estimate of the quantity of each
regulated pollutant emitted over any
applicable emission limit in § 63.3490
or any applicable operating limit in
Table 4 to this subpart, and a
description of the method used to
calculate the estimate, as reported under
§ 63.3511(a)(5) through (8).
(4) A record of actions taken to
minimize emissions in accordance with
§ 63.3500(b) and any corrective actions
taken to return the affected unit to its
normal or usual manner of operation.
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
(j) If you use the emission rate with
add-on controls option or the control
efficiency/outlet concentration option,
you must also keep the records specified
in paragraphs (j)(1) through (8) of this
section.
(1) Before August 24, 2020, for each
deviation, a record of whether the
deviation occurred during a period of
startup, shutdown, or malfunction. On
and after August 24, 2020, a record of
whether the deviation occurred during a
period of startup, shutdown, or
malfunction is not required.
(2) Before August 24, 2020, the
records in § 63.6(e)(3)(iii) through (v)
related to startup, shutdown, and
malfunction. On and after August 24,
2020, the records in § 63.6(e)(3)(iii)
through (v) related to startup, shutdown,
and malfunction are not required.
*
*
*
*
*
■ 8. Section 63.3513 is amended by
revising paragraph (a) to read as follows:
§ 63.3513 In what form and for how long
must I keep my records?
(a) Your records must be kept in a
form suitable and readily available for
expeditious review, according to
§ 63.10(b)(1). Where appropriate, the
records may be maintained as electronic
spreadsheets or as a database. On and
after August 24, 2020, any records
required to be maintained by this
subpart that are in reports that were
submitted electronically via the EPA’s
CEDRI may be maintained in electronic
format. This ability to maintain
electronic copies does not affect the
requirement for facilities to make
records, data, and reports available
upon request to a delegated air agency
or the EPA as part of an on-site
compliance evaluation.
*
*
*
*
*
■ 9. Section 63.3521 is amended by
revising paragraphs (a)(1)(i), (a)(2),
(a)(4), (b)(1), and (c) to read as follows:
§ 63.3521 How do I demonstrate initial
compliance with the emission limitations?
jbell on DSKJLSW7X2PROD with RULES2
*
*
*
*
*
(a) * * *
(1) * * *
(i) Count each organic HAP in Table
8 to this subpart that is measured to be
present at 0.1 percent by mass or more
and at 1.0 percent by mass or more for
other compounds. For example, if
toluene (not listed in Table 8 to this
subpart) is measured to be 0.5 percent
of the material by mass, you do not have
to count it. Express the mass fraction of
each organic HAP you count as a value
truncated to four places after the
decimal point (e.g., 0.3791).
*
*
*
*
*
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
(2) Method 24 (appendix A to 40 CFR
part 60). For coatings, you may use
Method 24 to determine the mass
fraction of nonaqueous volatile matter
and use that value as a substitute for
mass fraction of organic HAP. As an
alternative to using Method 24, you may
use ASTM D2369–10 (2015), ‘‘Test
Method for Volatile Content of
Coatings’’ (incorporated by reference,
see § 63.14).
*
*
*
*
*
(4) Information from the supplier or
manufacturer of the material. You may
rely on information other than that
generated by the test methods specified
in paragraphs (a)(1) through (3) of this
section, such as manufacturer’s
formulation data, if it represents each
organic HAP in Table 8 to this subpart
that is present at 0.1 percent by mass or
more and at 1.0 percent by mass or more
for other compounds. For example, if
toluene (not listed in Table 8 to this
subpart) is 0.5 percent of the material by
mass, you do not have to count it. If
there is a disagreement between such
information and results of a test
conducted according to paragraphs
(a)(1) through (3) of this section, then
the test method results will take
precedence unless, after consultation, a
regulated source can demonstrate to the
satisfaction of the enforcement agency
that the formulation data are correct.
*
*
*
*
*
(b) * * *
(1) ASTM Method D2697–03 (2014) or
D6093–97 (2016). You may use ASTM
D2697–03 (2014), ‘‘Standard Test
Method for Volume Nonvolatile Matter
in Clear or Pigmented Coatings,’’
(incorporated by reference, see § 63.14)
or ASTM D6093–97 (2016), ‘‘Standard
Test Method for Percent Volume
Nonvolatile Matter in Clear or
Pigmented Coatings Using a Helium Gas
Pycnometer’’ (incorporated by reference,
see § 63.14), to determine the volume
fraction of coating solids for each
coating. Divide the nonvolatile volume
percent obtained with the methods by
100 to calculate volume fraction of
coating solids. If these values cannot be
determined using these methods, the
owner/operator may submit an
alternative technique for determining
the values for approval by the
Administrator.
*
*
*
*
*
(c) Determine the density of each
coating. Determine the density of each
coating used during the compliance
period from test results using ASTM
Method D1475–13 ‘‘Standard Test
Method for Density of Liquid Coatings,
Inks, and Related Products’’
(incorporated by reference, see § 63.14)
PO 00000
Frm 00025
Fmt 4701
Sfmt 4700
10851
or information from the supplier or
manufacturer of the material. If there is
disagreement between ASTM Method
D1475–13 test results and the supplier’s
or manufacturer’s information, the test
results will take precedence.
*
*
*
*
*
■ 10. Section 63.3531 is amended by
revising paragraph (c) to read as follows:
§ 63.3531 How do I demonstrate initial
compliance with the emission limitations?
*
*
*
*
*
(c) Determine the density of each
material. Determine the density of each
coating and thinner used during each
month from test results using ASTM
D1475–13 or ASTM D2111–10 (2015)
(both incorporated by reference, see
§ 63.14), information from the supplier
or manufacturer of the material, or
reference sources providing density or
specific gravity data for pure materials.
If there is disagreement between ASTM
D1475–13 or ASTM D2111–10 (2015)
test results and such other information
sources, the test results will take
precedence.
*
*
*
*
*
■ 11. Section 63.3540 is amended by
revising the section heading and
paragraphs (a)(1), (a)(4), and (b)(1) to
read as follows:
§ 63.3540 By what date must I conduct
performance tests and initial compliance
demonstrations?
(a) * * *
(1) All emission capture systems, addon control devices, and CPMS must be
installed and operating no later than the
applicable compliance date specified in
§ 63.3483. Except for solvent recovery
systems for which you conduct liquidliquid material balances according to
§ 63.3541(i), you must conduct
according to the schedule in paragraphs
(a)(1)(i) and (ii) of this section initial
and periodic performance tests of each
capture system and add-on control
device according to the procedures in
§§ 63.3543, 63.3544, and 63.3545 and
establish the operating limits required
by § 63.3492. For a solvent recovery
system for which you conduct liquidliquid material balances according to
§ 63.3541(i), you must initiate the first
material balance no later than the
applicable compliance date specified in
§ 63.3483.
(i) You must conduct the initial
performance test and establish the
operating limits required by § 63.3492
no later than 180 days after the
applicable compliance date specified in
§ 63.3483.
(ii) If you are not required to complete
periodic performance tests as a
requirement of renewing your facility’s
E:\FR\FM\25FER2.SGM
25FER2
jbell on DSKJLSW7X2PROD with RULES2
10852
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
operating permit under 40 CFR part 70
or 40 CFR part 71, you must conduct the
first periodic performance test before
March 25, 2023, unless you already
have conducted a performance test on or
after March 25, 2018. Thereafter you
must conduct a performance test no
later than 5 years following the previous
performance test. Operating limits must
be confirmed or reestablished during
each performance test. If you are
required to complete periodic
performance tests as a requirement of
renewing your facility’s operating
permit under 40 CFR part 70 or 40 CFR
part 71, you must conduct the periodic
testing in accordance with the terms and
schedule required by your permit
conditions.
*
*
*
*
*
(4) For the initial compliance
demonstration, you do not need to
comply with the operating limits for the
emission capture system and add-on
control device required by § 63.3492
until after you have completed the
initial performance tests specified in
paragraph (a)(1) of this section. Instead,
you must maintain a log detailing the
operation and maintenance of the
emission capture system, add-on control
device, and continuous parameter
monitors during the period between the
compliance date and the performance
test. You must begin complying with the
operating limits established based on
the initial performance tests specified in
paragraph (a)(1) of this section for your
affected source on the date you
complete the performance tests. The
requirements in this paragraph (a)(4) do
not apply to solvent recovery systems
for which you conduct liquid-liquid
material balances according to the
requirements in § 63.3541(i).
(b) * * *
(1) All emission capture systems, addon control devices, and CPMS must be
installed and operating no later than the
applicable compliance date specified in
§ 63.3483. Except for solvent recovery
systems for which you conduct liquidliquid material balances according to
§ 63.3541(i), you must conduct
according to the schedule in paragraphs
(b)(1)(i) and (ii) of this section initial
and periodic performance tests of each
capture system and add-on control
device according to the procedures in
§§ 63.3543, 63.3544, and 63.3545 and
establish the operating limits required
by § 63.3492. For a solvent recovery
system for which you conduct liquidliquid material balances according to
§ 63.3541(i), you must initiate the first
material balance no later than the
compliance date specified in § 63.3483.
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
(i) You must conduct the initial
performance test and establish the
operating limits required by § 63.3492
no later than 180 days after the
applicable compliance date specified in
§ 63.3483.
(ii) If you are not required to complete
periodic performance tests as a
requirement of renewing your facility’s
operating permit under 40 CFR part 70
or 40 CFR part 71, you must conduct the
first periodic performance test before
March 25, 2023, unless you already
have conducted a performance test on or
after March 25, 2018. Thereafter you
must conduct a performance test no
later than 5 years following the previous
performance test. Operating limits must
be confirmed or reestablished during
each performance test. If you are
required to complete periodic
performance tests as a requirement of
renewing your facility’s operating
permit under 40 CFR part 70 or 40 CFR
part 71, you must conduct the periodic
testing in accordance with the terms and
schedule required by your permit
conditions.
*
*
*
*
*
■ 12. Section 63.3541 is amended by
revising paragraphs (h) introductory text
and (i)(3) to read as follows:
§ 63.3541 How do I demonstrate initial
compliance?
*
*
*
*
*
(h) Calculate the organic HAP
emission reduction for each controlled
coating operation not using liquid-liquid
material balances. For each controlled
coating operation using an emission
capture system and add-on control
device, other than a solvent recovery
system for which you conduct liquidliquid material balances, calculate the
organic HAP emission reduction, using
Equation 1 of this section. The
calculation applies the emission capture
system efficiency and add-on control
device efficiency to the mass of organic
HAP contained in the coatings and
thinners that are used in the coating
operation served by the emission
capture system and add-on control
device during each month. For any
period of time a deviation specified in
§ 63.3542(c) or (d) occurs in the
controlled coating operation, you must
assume zero efficiency for the emission
capture system and add-on control
device, unless you have other data
indicating the actual efficiency of the
emission capture system and add-on
control device, and the use of these data
has been approved by the
Administrator. Equation 1 of this
section treats the materials used during
such a deviation as if they were used on
PO 00000
Frm 00026
Fmt 4701
Sfmt 4700
an uncontrolled coating operation for
the time period of the deviation.
*
*
*
*
*
(i) * * *
(3) Determine the mass fraction of
volatile organic matter for each coating
and thinner used in the coating
operation controlled by the solvent
recovery system during the month, in kg
volatile organic matter per kg coating.
You may determine the volatile organic
matter mass fraction using Method 24 of
40 CFR part 60, appendix A, ASTM
D2369–10 (2015), ‘‘Test Method for
Volatile Content of Coatings’’
(incorporated by reference, see § 63.14),
or an EPA approved alternative method.
Alternatively, you may determine the
volatile organic matter mass fraction
using information provided by the
manufacturer or supplier of the coating.
In the event of any inconsistency
between information provided by the
manufacturer or supplier and the results
of Method 24 of 40 CFR part 60,
appendix A, ASTM D2369–10 (2015) or
an approved alternative method, the test
method results will take precedence
unless, after consultation, a regulated
source can demonstrate to the
satisfaction of the enforcement agency
that the formulation data are correct.
*
*
*
*
*
■ 13. Section 63.3542 is amended by
revising paragraphs (f) and (h) to read as
follows:
§ 63.3542 How do I demonstrate
continuous compliance with the emission
limitations?
*
*
*
*
*
(f) As part of each semiannual
compliance report required in § 63.3511,
you must identify the coating
operation(s) for which you used the
emission rate with add-on controls
option. If there were no deviations from
the emission limits in § 63.3490, the
operating limits in § 63.3492, and the
work practice standards in § 63.3493,
submit a statement that you were in
compliance with the emission
limitations during the reporting period
because the organic HAP emission rate
for each compliance period was less
than or equal to the applicable emission
limit in § 63.3490, and you achieved the
operating limits required by § 63.3492
and the work practice standards
required by § 63.3493 during each
compliance period.
*
*
*
*
*
(h) Before August 24, 2020, consistent
with §§ 63.6(e) and 63.7(e)(1),
deviations that occur during a period of
startup, shutdown, or malfunction of the
emission capture system, add-on control
device, or coating operation that may
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
affect emission capture or control device
efficiency are not violations if you
demonstrate to the Administrator’s
satisfaction that you were operating in
accordance with § 63.6(e)(1). The
Administrator will determine whether
deviations that occur during a period
you identify as a startup, shutdown, or
malfunction are violations according to
the provisions in § 63.6(e). On and after
August 24, 2020, deviations that occur
due to malfunction of the emission
capture system, add-on control device,
or coating operation that may affect
emission capture or control device
efficiency are required to operate in
accordance with § 63.3500(b). The
Administrator will determine whether
the deviations are violations according
to the provisions in § 63.3500(b).
*
*
*
*
*
■ 14. Section 63.3543 is amended by
revising paragraphs (a) introductory text
and (a)(1) to read as follows:
jbell on DSKJLSW7X2PROD with RULES2
§ 63.3543 What are the general
requirements for performance tests?
(a) Before August 24, 2020, you must
conduct each performance test required
by § 63.3540 according to the
requirements in § 63.7(e)(1) and under
the conditions in this section unless you
obtain a waiver of the performance test
according to the provisions in § 63.7(h).
On and after August 24, 2020, you must
conduct each performance test required
by § 63.3540 according to the
requirements in this section unless you
obtain a waiver of the performance test
according to the provisions in § 63.7(h).
(1) Representative coating operation
operating conditions. You must conduct
the performance test under
representative operating conditions for
the coating operation. Operations during
periods of startup, shutdown, or
nonoperation do not constitute
representative conditions for purposes
of conducting a performance test. The
owner or operator may not conduct
performance tests during periods of
malfunction. You must record the
process information that is necessary to
document operating conditions during
the test and explain why the conditions
represent normal operation. Upon
request, you must make available to the
Administrator such records as may be
necessary to determine the conditions of
performance tests.
*
*
*
*
*
■ 15. Section 63.3544 is amended by
revising the introductory text to read as
follows:
§ 63.3544 How do I determine the emission
capture system efficiency?
You must use the procedures and test
methods in this section to determine
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
capture efficiency as part of each
performance test required by § 63.3540.
*
*
*
*
*
■ 16. Section 63.3545 is amended by
revising the introductory text, paragraph
(b) introductory text, and paragraphs
(b)(1) through (4) to read as follows:
§ 63.3545 How do I determine the add-on
control device emission destruction or
removal efficiency?
You must use the procedures and test
methods in this section to determine the
add-on control device emission
destruction or removal efficiency as part
of the performance tests required by
§ 63.3540. For each performance test,
you must conduct three test runs as
specified in § 63.7(e)(3) and each test
run must last at least 1 hour.
*
*
*
*
*
(b) Measure total gaseous organic
mass emissions as carbon at the inlet
and outlet of the add-on control device
simultaneously using either Method 25
or 25A of appendix A–7 to 40 CFR part
60 as specified in paragraphs (b)(1)
through (5) of this section. You must use
the same method for both the inlet and
outlet measurements.
(1) Use Method 25 of appendix A–7
to 40 CFR part 60 if the add-on control
device is an oxidizer and you expect the
total gaseous organic concentration as
carbon to be more than 50 ppm at the
control device outlet.
(2) Use Method 25A of appendix A–
7 to 40 CFR part 60 if the add-on control
device is an oxidizer and you expect the
total gaseous organic concentration as
carbon to be 50 ppm or less at the
control device outlet.
(3) Use Method 25A of appendix A–
7 to 40 CFR part 60 if the add-control
device is not an oxidizer.
(4) You may use Method 18 of
appendix A–6 to 40 CFR part 60 to
subtract methane emissions from
measured total gaseous organic mass
emissions as carbon.
*
*
*
*
*
■ 17. Section 63.3546 is amended by
revising the introductory text and
paragraphs (a)(1) and (2), (b)(1) through
(3), (d)(1), (e)(1) and (2), (f)(1) through
(3), and (f)(5) and (6) to read as follows:
§ 63.3546 How do I establish the emission
capture system and add-on control device
operating limits during the performance
test?
During performance tests required by
§ 63.3540 and described in §§ 63.3543,
63.3544, and 63.3545, you must
establish the operating limits required
by § 63.3492 unless you have received
approval for alternative monitoring and
operating limits under § 63.8(f) as
specified in § 63.3492.
PO 00000
Frm 00027
Fmt 4701
Sfmt 4700
10853
(a) * * *
(1) During performance tests, you
must monitor and record the
combustion temperature at least once
every 15 minutes during each of the
three test runs. You must monitor the
temperature in the firebox of the
thermal oxidizer or immediately
downstream of the firebox before any
substantial heat exchange occurs.
(2) For each performance test, use the
data collected during the performance
test to calculate and record the average
combustion temperature maintained
during the performance test. That
average combustion temperature is the
minimum operating limit for your
thermal oxidizer.
(b) * * *
(1) During performance tests, you
must monitor and record the
temperature at the inlet to the catalyst
bed and the temperature difference
across the catalyst bed at least once
every 15 minutes during each of the
three test runs.
(2) For each performance test, use the
data collected during the performance
test to calculate and record the average
temperature at the inlet to the catalyst
bed and the average temperature
difference across the catalyst bed
maintained during the performance test.
The average temperature difference is
the minimum operating limit for your
catalytic oxidizer.
(3) As an alternative to monitoring the
temperature difference across the
catalyst bed, you may monitor the
temperature at the inlet to the catalyst
bed and implement a site-specific
inspection and maintenance plan for
your catalytic oxidizer as specified in
paragraph (b)(4) of this section. During
performance tests, you must monitor
and record the temperature at the inlet
to the catalyst bed at least once every 15
minutes during each of the three test
runs. For each performance test, use the
data collected during the performance
test to calculate and record the average
temperature at the inlet to the catalyst
bed during the performance test. That is
the minimum operating limit for your
catalytic oxidizer.
*
*
*
*
*
(d) * * *
(1) During performance tests, you
must monitor and record the total
regeneration desorbing gas (e.g., steam
or nitrogen) mass flow for each
regeneration cycle, and the carbon bed
temperature after each carbon bed
regeneration and cooling cycle for the
regeneration cycle either immediately
preceding or immediately following the
performance test.
*
*
*
*
*
E:\FR\FM\25FER2.SGM
25FER2
jbell on DSKJLSW7X2PROD with RULES2
10854
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
(e) * * *
(1) During performance tests, monitor
and record the condenser outlet
(product side) gas temperature at least
once every 15 minutes during each of
the three test runs of the performance
test.
(2) For each performance test, use the
data collected during the performance
test to calculate and record the average
condenser outlet (product side) gas
temperature maintained during the
performance test. This average
condenser outlet gas temperature is the
maximum operating limit for your
condenser.
(f) * * *
(1) During performance tests, monitor
and record the inlet temperature to the
desorption/reactivation zone of the
concentrator at least once every 15
minutes during each of the three runs of
the performance test.
(2) For each performance test, use the
data collected during the performance
test to calculate and record the average
temperature. This is the minimum
operating limit for the desorption/
reactivation zone inlet temperature.
(3) During each performance test,
monitor and record an indicator(s) of
performance for the desorption/
reactivation fan operation at least once
every 15 minutes during each of the
three runs of the performance test. The
indicator can be speed in revolutions
per minute (rpm), power in amps, static
pressure, or flow rate.
*
*
*
*
*
(5) During each performance test,
monitor the rotational speed of the
concentrator at least once every 15
minutes during each of the three runs of
the performance test.
(6) For each performance test, use the
data collected during the performance
test to calculate and record the average
rotational speed. This is the minimum
operating limit for the rotational speed
of the concentrator. However, the
indicator range for the rotational speed
may be changed if an engineering
evaluation is conducted and a
determination made that the change in
speed will not affect compliance with
the emission limit.
*
*
*
*
*
■ 18. Section 63.3547 is amended by
revising paragraphs (a)(4) and (5), (a)(7),
and (c)(3) introductory text to read as
follows:
have available necessary parts for
routine repairs of the monitoring
equipment. On and after August 24,
2020, you must maintain the CPMS at
all times in accordance with
§ 63.3500(b) and keep necessary parts
readily available for routine repairs of
the monitoring equipment.
(5) Before August 24, 2020, you must
operate the CPMS and collect emission
capture system and add-on control
device parameter data at all times that
a controlled coating operation is
operating, except during monitoring
malfunctions, associated repairs, and
required quality assurance or control
activities (including, if applicable,
calibration checks and required zero
and span adjustments). On and after
August 24, 2020, you must operate the
CPMS and collect emission capture
system and add-on control device
parameter data at all times in
accordance with § 63.3500(b).
*
*
*
*
*
(7) A monitoring malfunction is any
sudden, infrequent, not reasonably
preventable failure of the CPMS to
provide valid data. Monitoring failures
that are caused, in part, by poor
maintenance or careless operation are
not malfunctions. Before August 24,
2020, any period for which the
monitoring system is out of control and
data are not available for required
calculations is a deviation from the
monitoring requirements. On and after
August 24, 2020, except for periods of
required quality assurance or control
activities, any period for which the
CPMS fails to operate and record data
continuously as required by paragraph
(a)(5) of this section, or generates data
that cannot be included in calculating
averages as specified in (a)(6) of this
section constitutes a deviation from the
monitoring requirements.
*
*
*
*
*
(c) * * *
(3) For all thermal oxidizers and
catalytic oxidizers, you must meet the
requirements in paragraphs (a) and
(c)(3)(i) through (ii) of this section for
each gas temperature monitoring device.
For the purposes of this paragraph
(c)(3), a thermocouple is part of the
temperature sensor.
*
*
*
*
*
■ 19. Section 63.3550 is amended by
revising the section heading and
paragraphs (a)(1), (a)(4), and (b)(1) to
read as follows:
§ 63.3547 What are the requirements for
continuous parameter monitoring system
installation, operation, and maintenance?
§ 63.3550 By what date must I conduct
performance tests and initial compliance
demonstrations?
(a) * * *
(4) Before August 24, 2020, you must
maintain the CPMS at all times and
(a) * * *
(1) All emission capture systems, addon control devices, and CPMS must be
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
PO 00000
Frm 00028
Fmt 4701
Sfmt 4700
installed and operating no later than the
applicable compliance date specified in
§ 63.3483. You must conduct according
to the schedule in paragraphs (a)(1)(i)
and (ii) of this section initial and
periodic performance tests of each
capture system and add-on control
device according to §§ 63.3553, 63.3554,
and 63.3555 and establish the operating
limits required by § 63.3492.
(i) You must conduct the initial
performance test and establish the
operating limits required by § 63.3492
no later than 180 days after the
applicable compliance date specified in
§ 63.3483.
(ii) If you are not required to complete
periodic performance tests as a
requirement of renewing your facility’s
operating permit under 40 CFR part 70
or 40 CFR part 71, you must conduct the
first periodic performance test before
March 25, 2023, unless you already
have conducted a performance test on or
after March 25, 2018. Thereafter you
must conduct a performance test no
later than 5 years following the previous
performance test. Operating limits must
be confirmed or reestablished during
each performance test. If you are
required to complete periodic
performance tests as a requirement of
renewing your facility’s operating
permit under 40 CFR part 70 or 40 CFR
part 71, you must conduct the periodic
testing in accordance with the terms and
schedule required by your permit
conditions.
*
*
*
*
*
(4) For the initial compliance
demonstration, you do not need to
comply with the operating limits for the
emission capture system and add-on
control device required by § 63.3492
until after you have completed the
initial performance tests specified in
paragraph (a)(1) of this section. Instead,
you must maintain a log detailing the
operation and maintenance of the
emission capture system, add-on control
device, and continuous parameter
monitors during the period between the
compliance date and the performance
test. You must begin complying with the
operating limits established based on
the initial performance tests specified in
paragraph (a)(1) of this section on the
date you complete the performance
tests.
(b) * * *
(1) All emission capture systems, addon control devices, and CPMS must be
installed and operating no later than the
applicable compliance date specified in
§ 63.3483. Except for solvent recovery
systems for which you conduct liquidliquid material balances according to
§ 63.3541(i), you must conduct
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
according to the schedule in paragraphs
(a)(1)(i) and (ii) of this section initial
and periodic performance tests of each
capture system and add-on control
device according to the procedures in
§§ 63.3543, 63.3544, and 63.3545 and
establish the operating limits required
by § 63.3492.
(i) You must conduct the initial
performance test and establish the
operating limits required by § 63.3492
no later than 180 days after the
applicable compliance date specified in
§ 63.3483.
(ii) If you are not required to complete
periodic performance tests as a
requirement of renewing your facility’s
operating permit under 40 CFR part 70
or 40 CFR part 71, you must conduct the
first periodic performance test before
March 25, 2023, unless you already
have conducted a performance test on or
after March 25, 2018. Thereafter you
must conduct a performance test no
later than 5 years following the previous
performance test. Operating limits must
be confirmed or reestablished during
each performance test. If you are
required to complete periodic
performance tests as a requirement of
renewing your facility’s operating
permit under 40 CFR part 70 or 40 CFR
part 71, you must conduct the periodic
testing in accordance with the terms and
schedule required by your permit
conditions.
*
*
*
*
*
■ 20. Section 63.3552 is amended by
revising paragraph (g) to read as follows:
§ 63.3552 How do I demonstrate
continuous compliance with the emission
limitations?
jbell on DSKJLSW7X2PROD with RULES2
*
*
*
*
*
(g) Before August 24, 2020, consistent
with §§ 63.6(e) and 63.7(e)(1),
deviations that occur during a period of
startup, shutdown, or malfunction of the
emission capture system, add-on control
device, or coating operation that may
affect emission capture or control device
efficiency are not violations if you
demonstrate to the Administrator’s
satisfaction that you were operating in
accordance with § 63.6(e)(1). The
Administrator will determine whether
deviations that occur during a period
you identify as a startup, shutdown, or
malfunction are violations, according to
the provisions in § 63.6(e). On and after
August 24, 2020 deviations that occur
due to malfunction of the emission
capture system, add-on control device,
or coating operation that may affect
emission capture or control device
efficiency are required to operate in
accordance with § 63.3500(b). The
Administrator will determine whether
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
the deviations are violations according
to the provisions in § 63.3500(b).
*
*
*
*
*
■ 21. Section 63.3553 is amended by
revising paragraphs (a) introductory text
and (a)(1) to read as follows:
§ 63.3553 What are the general
requirements for performance tests?
(a) Before August 24, 2020, you must
conduct each performance test required
by § 63.3550 according to the
requirements in § 63.7(e)(1) and under
the conditions in this section unless you
obtain a waiver of the performance test
according to the provisions in § 63.7(h).
On and after August 24, 2020, you must
conduct each performance test required
by § 63.3550 according to the
requirements in this section unless you
obtain a waiver of the performance test
according to the provisions in § 63.7(h).
(1) Representative coating operating
conditions. You must conduct the
performance test under representative
operating conditions for the coating
operation(s). Operations during periods
of startup, shutdown, or nonoperation
do not constitute representative
conditions for purposes of conducting a
performance test. The owner or operator
may not conduct performance tests
during periods of malfunction. You
must record the process information
that is necessary to document operating
conditions during the test and explain
why the conditions represent normal
operation. Upon request, you must make
available to the Administrator such
records as may be necessary to
determine the conditions of
performance tests.
*
*
*
*
*
■ 22. Section 63.3555 is amended by
revising the introductory text, paragraph
(b) introductory text, and paragraphs
(b)(1) through (4) to read as follows:
§ 63.3555 How do I determine the outlet
THC emissions and add-on control device
emission destruction or removal efficiency?
You must use the procedures and test
methods in this section to determine
either the outlet THC emissions or addon control device emission destruction
or removal efficiency as part of the
performance tests required by § 63.3550.
You must conduct three test runs as
specified in § 63.7(e)(3), and each test
run must last at least 1 hour.
*
*
*
*
*
(b) Measure total gaseous organic
mass emissions as carbon at the inlet
and outlet of the add-on control device
simultaneously using either Method 25
or 25A of appendix A–7 to 40 CFR part
60 as specified in paragraphs (b)(1)
through (3) of this section. You must use
PO 00000
Frm 00029
Fmt 4701
Sfmt 4700
10855
the same method for both the inlet and
outlet measurements.
(1) Use Method 25 of appendix A–7
to 40 CFR part 60 if the add-on control
device is an oxidizer, and you expect
the total gaseous organic concentration
as carbon to be more than 50 ppm at the
control device outlet.
(2) Use Method 25A of appendix A–
7 to 40 CFR part 60 if the add-on control
device is an oxidizer, and you expect
the total gaseous organic concentration
as carbon to be 50 ppm or less at the
control device outlet.
(3) Use Method 25A of appendix A–
7 to 40 CFR part 60 if the add-on control
device is not an oxidizer.
(4) You may use Method 18 of
appendix A–6 to 40 CFR part 60 to
subtract methane emissions from
measured total gaseous organic mass
emissions as carbon.
*
*
*
*
*
■ 23. Section 63.3556 is amended by
revising the introductory text and
paragraphs (a)(1) and (2), (b)(1) through
(3), (d)(1), (e)(1) and (2), (f)(1) through
(3), and (f)(5) and (6) to read as follows:
§ 63.3556 How do I establish the emission
capture system and add-on control device
operating limits during the performance
test?
During the performance tests required
by § 63.3550 and described in
§§ 63.3553, 63.3554, and 63.3555, you
must establish the operating limits
required by § 63.3492 according to this
section, unless you have received
approval for alternative monitoring and
operating limits under § 63.8(f) as
specified in § 63.3492.
(a) * * *
(1) During performance tests, you
must monitor and record the
combustion temperature at least once
every 15 minutes during each of the
three test runs. You must monitor the
temperature in the firebox of the
thermal oxidizer or immediately
downstream of the firebox before any
substantial heat exchange occurs.
(2) For each performance test, use the
data collected during the performance
test to calculate and record the average
combustion temperature maintained
during the performance test. That
average combustion temperature is the
minimum operating limit for your
thermal oxidizer.
(b) * * *
(1) During performance tests, you
must monitor and record the
temperature at the inlet to the catalyst
bed and the temperature difference
across the catalyst bed at least once
every 15 minutes during each of the
three test runs.
E:\FR\FM\25FER2.SGM
25FER2
jbell on DSKJLSW7X2PROD with RULES2
10856
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
(2) For each performance test, use the
data collected during the performance
test to calculate and record the average
temperature at the inlet to the catalyst
bed and the average temperature
difference across the catalyst bed
maintained during the performance test.
The average temperature difference is
the minimum operating limit for your
catalytic oxidizer.
(3) As an alternative to monitoring the
temperature difference across the
catalyst bed, you may monitor the
temperature at the inlet to the catalyst
bed and implement a site-specific
inspection and maintenance plan for
your catalytic oxidizer as specified in
paragraph (b)(4) of this section. During
performance tests, you must monitor
and record the temperature at the inlet
to the catalyst bed at least once every 15
minutes during each of the three test
runs. Use the data collected during each
performance test to calculate and record
the average temperature at the inlet to
the catalyst bed during the performance
test. That is the minimum operating
limit for your catalytic oxidizer.
*
*
*
*
*
(d) * * *
(1) You must monitor and record the
total regeneration desorbing gas (e.g.,
steam or nitrogen) mass flow for each
regeneration cycle, and the carbon bed
temperature after each carbon bed
regeneration and cooling cycle for the
regeneration cycle either immediately
preceding or immediately following
performance tests.
*
*
*
*
*
(e) * * *
(1) During performance tests, monitor
and record the condenser outlet
(product side) gas temperature at least
once every 15 minutes during each of
the three test runs.
(2) For each performance test, use the
data collected during the performance
test to calculate and record the average
condenser outlet (product side) gas
temperature maintained during the
performance test. This average
condenser outlet gas temperature is the
maximum operating limit for your
condenser.
(f) * * *
(1) During performance tests, monitor
and record the inlet temperature to the
desorption/reactivation zone of the
concentrator at least once every 15
minutes during each of the three runs of
the performance test.
(2) For each performance test, use the
data collected during the performance
test to calculate and record the average
temperature. This is the minimum
operating limit for the desorption/
reactivation zone inlet temperature.
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
(3) During performance tests, monitor
and record an indicator(s) of
performance for the desorption/
reactivation fan operation at least once
every 15 minutes during each of the
three runs of the performance test. The
indicator can be speed in rpm, power in
amps, static pressure, or flow rate.
*
*
*
*
*
(5) During performance tests, monitor
the rotational speed of the concentrator
at least once every 15 minutes during
each of the three runs of a performance
test.
(6) For each performance test, use the
data collected during the performance
test to calculate and record the average
rotational speed. This is the minimum
operating limit for the rotational speed
of the concentrator. However, the
indicator range for the rotational speed
may be changed if an engineering
evaluation is conducted and a
determination made that the change in
speed will not affect compliance with
the emission limit.
*
*
*
*
*
■ 24. Section 63.3557 is amended by
revising paragraphs (a)(4) and (5), (a)(7),
and (c)(3) introductory text to read as
follows:
§ 63.3557 What are the requirements for
continuous parameter monitoring system
installation, operation, and maintenance?
(a) * * *
(4) You must maintain the CPMS at
all times in accordance with
§ 63.3500(b) and have readily available
necessary parts for routine repairs of the
monitoring equipment.
(5) You must operate the CPMS and
collect emission capture system and
add-on control device parameter data at
all times in accordance with
§ 63.3500(b) that a controlled coating
operation is operating, except during
monitoring malfunctions, associated
repairs, and required quality assurance
or control activities (including, if
applicable, calibration checks and
required zero and span adjustments).
*
*
*
*
*
(7) A monitoring malfunction is any
sudden, infrequent, not reasonably
preventable failure of the CPMS to
provide valid data. Monitoring failures
that are caused, in part, by poor
maintenance or careless operation are
not malfunctions. Before August 24,
2020, any period for which the
monitoring system is out of control and
data are not available for required
calculations is a deviation from the
monitoring requirements. On and after
August 24, 2020, except for periods of
required quality assurance or control
activities, any period for which the
PO 00000
Frm 00030
Fmt 4701
Sfmt 4700
CPMS fails to operate and record data
continuously as required by paragraph
(a)(5) of this section, or generates data
that cannot be included in calculating
averages as specified in (a)(6) of this
section constitutes a deviation from the
monitoring requirements.
*
*
*
*
*
(c) * * *
(3) For all thermal oxidizers and
catalytic oxidizers, you must meet the
requirements in paragraphs (a) and
(c)(3)(i) through (ii) of this section for
each gas temperature monitoring device.
For the purposes of this paragraph
(c)(3), a thermocouple is part of the
temperature sensor.
*
*
*
*
*
■ 25. Section 63.3561 is amended by
removing the definition for ‘‘Deviation’’
and adding definitions for ‘‘Deviation,
before’’ and ‘‘Deviation, on and after’’ in
alphabetical order to read as follows:
§ 63.3561
subpart?
What definitions apply to this
*
*
*
*
*
Deviation, before August 24, 2020,
means any instance in which an affected
source subject to this subpart or an
owner or operator of such a source:
(1) Fails to meet any requirement or
obligation established by this subpart
including but not limited to any
emission limit, operating limit, or work
practice standard; or
(2) Fails to meet any term or condition
that is adopted to implement an
applicable requirement in this subpart
and that is included in the operating
permit for any affected source required
to obtain such a permit; or
(3) Fails to meet any emission limit,
operating limit, or work practice
standard in this subpart during startup,
shutdown, or malfunction regardless of
whether or not such failure is permitted
by this subpart.
Deviation, on and after August 24,
2020, means any instance in which an
affected source subject to this subpart or
an owner or operator of such a source:
(1) Fails to meet any requirement or
obligation established by this subpart
including but not limited to any
emission limit, operating limit, or work
practice standard; or
(2) Fails to meet any term or condition
that is adopted to implement an
applicable requirement in this subpart
and that is included in the operating
permit for any affected source required
to obtain such a permit.
*
*
*
*
*
■ 26. Table 5 to subpart KKKK of part
63 is revised to read as follows:
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
10857
TABLE 5 TO SUBPART KKKK OF PART 63—APPLICABILITY OF GENERAL PROVISIONS TO SUBPART KKKK
You must comply with the applicable General Provisions requirements according to the following table:
Citation
Subject
Applicable to subpart KKKK
§ 63.1(a)(1)–(4) ..............................
§ 63.1(a)(6) .....................................
§ 63.1(a)(10)–(12) ..........................
§ 63.1(b)(1) .....................................
General Applicability .....................
Source Category Listing ...............
Timing and Overlap Clarifications
Initial Applicability Determination ..
Yes.
Yes.
Yes.
Yes ................................................
§ 63.1(b)(3) .....................................
Applicability Determination Recordkeeping.
Applicability after Standard Established.
Applicability of Permit Program for
Area Sources.
Extensions and Notifications ........
Applicability of Permit Program
before Relevant Standard is Set.
Definitions .....................................
Yes.
Yes.
Yes.
Yes.
Yes.
Yes.
§ 63.6(e)(1)(i)–(ii) ...........................
Units and Abbreviations ...............
Prohibited Activities ......................
Circumvention/Fragmentation .......
Construction/Reconstruction .........
Requirements for Existing, Newly
Constructed,
and
Reconstructed Sources.
Application for Approval of Construction/Reconstruction.
Approval of Construction/Reconstruction.
Approval of Construction/Reconstruction Based on Prior State
Review.
Compliance with Standards and
Maintenance Requirements—
Applicability.
Compliance Dates for New and
Reconstructed Sources.
Compliance Dates for Existing
Sources.
Operation and Maintenance .........
§ 63.6(e)(1)(iii) ................................
§ 63.6(e)(3)(i), (e)(3)(iii)–(ix) ...........
Operation and Maintenance .........
SSMP ............................................
§ 63.6(f)(1) ......................................
Compliance Except during Startup, Shutdown, and Malfunction.
Methods for Determining Compliance.
Use of an Alternative Standard ....
Compliance with Opacity/Visible
Emission Standards.
§ 63.1(c)(1) .....................................
§ 63.1(c)(2) .....................................
§ 63.1(c)(5) .....................................
§ 63.1(e) .........................................
§ 63.2 .............................................
§ 63.3 .............................................
§ 63.4(a)(1)–(2) ..............................
§ 63.4(b)–(c) ...................................
§ 63.5(a) .........................................
§ 63.5(b)(1), (3), (4), (6) .................
§ 63.5(d)(1)(i)–(ii)(F), (d)(1)(ii)(H),
(d)(1)(ii)(J), (d)(1)(iii), (d)(2)–(4).
§ 63.5(e) .........................................
§ 63.5(f) ..........................................
§ 63.6(a) .........................................
§ 63.6(b)(1)–(5), (b)(7) ...................
§ 63.6(c)(1), (2), (5) ........................
§ 63.6(f)(2)–(3) ...............................
§ 63.6(g) .........................................
§ 63.6(h) .........................................
§ 63.6(i)(1)–(14) .............................
§ 63.6(i)(16) ....................................
§ 63.6(j) ..........................................
§ 63.7(a)(1) .....................................
jbell on DSKJLSW7X2PROD with RULES2
§ 63.7(a)(2) except (a)(2)(i)–(viii) ...
VerDate Sep<11>2014
20:57 Feb 24, 2020
Explanation
Yes.
No .................................................
Yes ................................................
Yes.
Yes.
Yes.
Yes ................................................
Yes ................................................
Yes before August 24, 2020, No
on and after August 24, 2020.
Yes.
Yes before August 24, 2020, No
on and after August 24, 2020.
Yes before August 24, 2020, No
on and after August 24, 2020.
Yes.
Yes.
No .................................................
Performance
Test
ments—Dates.
Yes ................................................
PO 00000
Frm 00031
Fmt 4701
Additional definitions are specified
in § 63.3561.
Yes.
Yes.
Yes.
Jkt 250001
Area sources are not subject to
subpart KKKK.
Yes.
Yes.
Extension of Compliance ..............
Compliance Extensions and Administrator’s Authority.
Presidential Compliance Exemption.
Performance
Test
Requirements—Applicability.
Require-
Applicability to subpart KKKK is
also specified in § 63.3481.
Section 63.3483 specifies the
compliance dates.
Section 63.3483 specifies the
compliance dates.
See § 63.3500(b) for general duty
requirement.
Subpart KKKK does not establish
opacity standards and does not
require continuous opacity monitoring systems (COMS).
Yes.
Yes ................................................
Sfmt 4700
E:\FR\FM\25FER2.SGM
Applies to all affected sources.
Additional requirements for performance testing are specified
in
§§ 63.3543,
63.3544,
63.3545, 63.3554, and 63.3555.
Applies only to performance tests
for capture system and control
device efficiency at sources
using these to comply with the
standards. Sections 63.3540
and 63.3550 specify the schedule for performance test requirements that are earlier than
those specified in § 63.7(a)(2).
25FER2
10858
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
TABLE 5 TO SUBPART KKKK OF PART 63—APPLICABILITY OF GENERAL PROVISIONS TO SUBPART KKKK—Continued
You must comply with the applicable General Provisions requirements according to the following table:
Citation
Subject
§ 63.7(a)(3) .....................................
Performance Tests Required by
the Administrator.
Performance
Test
Requirements—Notification, Quality Assurance, Facilities Necessary
for Safe Testing, Conditions
During Test.
Conduct of Performance Tests ....
§ 63.7(b)–(d) ...................................
§ 63.7(e)(1) .....................................
§ 63.7(e)(2)–(4) ..............................
§ 63.7(f) ..........................................
jbell on DSKJLSW7X2PROD with RULES2
§ 63.7(g)–(h) ...................................
Applicable to subpart KKKK
Conduct of Performance Tests ....
Performance
Test
Requirements—Use of Alternative Test
Method.
Performance
Test
Requirements—Data Analysis, Recordkeeping, Reporting, Waiver of
Test.
Explanation
Yes.
Yes ................................................
Yes before August 24, 2020, No
on and after August 24, 2020.
Yes.
Yes ................................................
Yes ................................................
§ 63.8(a)(1)–(2) ..............................
Monitoring Requirements—Applicability.
Yes ................................................
§ 63.8(a)(4) .....................................
Additional
ments.
Require-
No .................................................
§ 63.8(b) .........................................
§ 63.8(c)(1) .....................................
Conduct of Monitoring ..................
Continuous Monitoring System
(CMS) Operation and Maintenance.
Yes.
Yes before August 24, 2020, No
on and after August 24, 2020.
§ 63.8(c)(2)–(3) ..............................
CMS Operation and Maintenance
Yes ................................................
§ 63.8(c)(4) .....................................
CMS ..............................................
No .................................................
§ 63.8(c)(5) .....................................
COMS ...........................................
No .................................................
§ 63.8(c)(6) .....................................
CMS Requirements ......................
No .................................................
§ 63.8(c)(7) .....................................
§ 63.8(c)(8) .....................................
CMS Out-of-Control Periods ........
CMS Out-of-Control Periods Reporting.
Yes.
No .................................................
§ 63.8(d)–(e) ...................................
Quality Control Program and CMS
Performance Evaluation.
Use of an Alternative Monitoring
Method.
Alternative to Relative Accuracy
Test.
No.
§ 63.8(f)(1)–(5) ...............................
§ 63.8(f)(6) ......................................
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
Monitoring
PO 00000
Frm 00032
Fmt 4701
Applies only to performance tests
for capture system and add-on
control device efficiency at
sources using these to comply
with the standards.
See §§ 63.3543 and 63.3553.
Applies to all test methods except
those used to determine capture system efficiency.
Applies only to performance tests
for capture system and add-on
control device efficiency at
sources using these to comply
with the standards.
Applies only to monitoring of capture system and add-on control
device efficiency at sources
using these to comply with the
standards. Additional requirements for monitoring are specified in §§ 63.3547 and 63.3557.
Subpart KKKK does not have
monitoring requirements for
flares.
Sections 63.3547 and 63.3557
specify the requirements for the
operation of CMS for capture
systems and add-on control devices at sources using these to
comply.
Applies only to monitoring of capture system and add-on control
device efficiency at sources
using these to comply with the
standards. Additional requirements for CMS operations and
maintenance are specified in
§§ 63.3547 and 63.3557.
Sections 63.3547 and 63.3557
specify the requirements for the
operation of CMS for capture
systems and add-on control devices at sources using these to
comply.
Subpart KKKK does not have
opacity or visible emission
standards.
Sections 63.3547 and 63.3557
specify the requirements for
monitoring systems for capture
systems and add-on control devices at sources using these to
comply.
Section 63.3511 requires reporting of CMS out of control periods.
Yes.
No .................................................
Sfmt 4700
E:\FR\FM\25FER2.SGM
Section 63.8(f)(6) provisions are
not applicable because subpart
KKKK does not require CEMS.
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
10859
TABLE 5 TO SUBPART KKKK OF PART 63—APPLICABILITY OF GENERAL PROVISIONS TO SUBPART KKKK—Continued
You must comply with the applicable General Provisions requirements according to the following table:
Citation
Subject
Applicable to subpart KKKK
Explanation
§ 63.8(g) .........................................
Data Reduction .............................
No .................................................
Sections
63.3542,
63.3547,
63.3552 and 63.3557 specify
monitoring data reduction.
§ 63.9(a) .........................................
§ 63.9(b)(1)–(2) ..............................
§ 63.9(b)(4)(i), (b)(4)(v), (b)(5) .......
Notification Applicability ................
Initial Notifications .........................
Application for Approval of Construction or Reconstruction.
Request for Extension of Compliance.
Special Compliance Requirement
Notification.
Notification of Performance Test ..
Yes.
Yes.
Yes.
§ 63.9(f) ..........................................
Notification of Visible Emissions/
Opacity Test.
No .................................................
§ 63.9(g) .........................................
Additional Notifications When
Using CMS.
Notification of Compliance Status
No.
Clarifications .................................
Adjustment of Submittal Deadlines.
Change in Previous Information ...
Recordkeeping/Reporting—Applicability and General Information.
General Recordkeeping Requirements.
Recordkeeping of Occurrence and
Duration of Startups and Shutdowns and of Failures to Meet
Standards.
Recordkeeping Relevant to Maintenance of Air Pollution Control
and Monitoring Equipment.
Actions Taken to Minimize Emissions During Startup, Shutdown, and Malfunction.
Yes.
Yes.
§ 63.10(b)(2)(vi) ..............................
Recordkeeping for CMS Malfunctions.
Yes before August 24, 2020, No
on and after August 24, 2020.
§ 63.10(b)(2)
§ 63.10(b)(2)
§ 63.10(b)(2)
§ 63.10(b)(3)
Records ........................................
.......................................................
.......................................................
Recordkeeping Requirements for
Applicability Determinations.
Additional Recordkeeping Requirements for Sources with
CMS.
.......................................................
Additional Recordkeeping Requirements for Sources with
CMS.
Yes.
No.
Yes.
Yes.
Additional Recordkeeping Requirements for Sources with
CMS.
Records Regarding the Startup,
Shutdown, and Malfunction
Plan.
General Reporting Requirements
Yes.
§ 63.9(c) .........................................
§ 63.9(d) .........................................
§ 63.9(e) .........................................
§ 63.9(h)(1)–(3) ..............................
§ 63.9(h)(5)–(6) ..............................
§ 63.9(i) ..........................................
§ 63.9(j) ..........................................
§ 63.10(a) .......................................
§ 63.10(b)(1) ...................................
§ 63.10(b)(2)(i)–(ii) ..........................
§ 63.10(b)(2)(iii) ..............................
§ 63.10(b)(2)(iv)–(v) .......................
(vii)–(xii) ....................
(xiii) ...........................
(xiv) ...........................
...................................
§ 63.10(c)(1) ...................................
§ 63.10(c)(5)–(6) ............................
§ 63.10(c)(7)–(8) ............................
jbell on DSKJLSW7X2PROD with RULES2
§ 63.10(c)(10)–(14) ........................
§ 63.10(c)(15) .................................
§ 63.10(d)(1) ...................................
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
PO 00000
Frm 00033
Fmt 4701
Yes.
Yes.
Yes ................................................
Yes ................................................
Applies only to capture system
and add-on control device performance tests at sources using
these to comply with the standards.
Subpart KKKK does not have
opacity or visible emission
standards.
Section 63.3510 specifies the
dates for submitting the notification of compliance status.
Yes.
Yes.
Yes ................................................
Yes before August 24, 2020, No
on and after August 24, 2020.
Additional requirements are specified in §§ 63.3512 and 63.3513.
See § 63.3512(i).
Yes.
Yes before August 24, 2020, No
on and after August 24, 2020.
See § 63.3512(i)(4) for a record of
actions taken to minimize emissions duration a deviation from
the standard.
See § 63.3512(i) for records of
periods of deviation from the
standard, including instances
where a CMS is inoperative or
out-of-control.
Yes.
Yes.
No .................................................
See § 63.3512(i) for records of
periods of deviation from the
standard, including instances
where a CMS is inoperative or
out-of-control.
Yes before August 24, 2020, No
on and after August 24, 2020.
Yes ................................................
Sfmt 4700
E:\FR\FM\25FER2.SGM
Additional requirements are specified in § 63.3511.
25FER2
10860
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
TABLE 5 TO SUBPART KKKK OF PART 63—APPLICABILITY OF GENERAL PROVISIONS TO SUBPART KKKK—Continued
You must comply with the applicable General Provisions requirements according to the following table:
Citation
Subject
Applicable to subpart KKKK
Explanation
§ 63.10(d)(2) ...................................
Report of Performance Test Results.
Reporting Opacity or Visible
Emissions Observations.
Yes ................................................
Additional requirements are specified in § 63.3511(b).
Subpart KKKK does not require
opacity or visible emissions observations.
Progress Reports for Sources
with Compliance Extensions.
Startup, Shutdown, Malfunction
Reports.
Additional CMS Reports ...............
Excess Emissions/CMS Performance Reports.
Yes.
§ 63.10(e)(4) ...................................
COMS Data Reports ....................
No .................................................
§ 63.10(f) ........................................
§ 63.11 ...........................................
Yes.
No .................................................
§ 63.12 ...........................................
§ 63.13(a) .......................................
Recordkeeping/Reporting Waiver
Control Device Requirements/
Flares.
State Authority and Delegations ...
Addresses .....................................
§ 63.13(b) .......................................
§ 63.13(c) .......................................
Submittal to State Agencies .........
Submittal to State Agencies .........
§ 63.14 ...........................................
§ 63.15 ...........................................
Incorporation by Reference ..........
Availability of Information/Confidentiality.
§ 63.10(d)(3) ...................................
§ 63.10(d)(4) ...................................
§ 63.10(d)(5) ...................................
§ 63.10(e)(1)–(2) ............................
§ 63.10(e)(3) ...................................
No .................................................
Yes before August 24, 2020, No
on and after August 24, 2020.
No.
No .................................................
See § 63.3511(a)(7) and (8).
Section 63.3511(b) specifies the
contents of periodic compliance
reports.
Subpart KKKK does not specify
requirements for opacity or
COMS.
Subpart KKKK does not specify
use of flares for compliance.
Yes.
Yes before August 24, 2020, No
on and after August 24, 2020.
Yes.
Yes before August 24, 2020, No
unless the state requires the
submittal via CEDRI, on and
after August 24, 2020.
Yes.
Yes.
27. Table 8 to subpart KKKK of part
63 is added to read as follows:
■
TABLE 8 TO SUBPART KKKK OF PART 63—LIST OF HAZARDOUS AIR POLLUTANTS THAT MUST BE COUNTED TOWARD
TOTAL ORGANIC HAP CONTENT IF PRESENT AT 0.1 PERCENT OR MORE BY MASS
jbell on DSKJLSW7X2PROD with RULES2
Chemical name
CAS No.
1,1,2,2-Tetrachloroethane ....................................................................................................................................................................
1,1,2-Trichloroethane ...........................................................................................................................................................................
1,1-Dimethylhydrazine .........................................................................................................................................................................
1,2-Dibromo-3-chloropropane ..............................................................................................................................................................
1,2-Diphenylhydrazine .........................................................................................................................................................................
1,3-Butadiene .......................................................................................................................................................................................
1,3-Dichloropropene ............................................................................................................................................................................
1,4-Dioxane ..........................................................................................................................................................................................
2,4,6-Trichlorophenol ...........................................................................................................................................................................
2,4/2,6-Dinitrotoluene (mixture) ...........................................................................................................................................................
2,4-Dinitrotoluene .................................................................................................................................................................................
2,4-Toluene diamine ............................................................................................................................................................................
2-Nitropropane .....................................................................................................................................................................................
3,3′-Dichlorobenzidine .........................................................................................................................................................................
3,3′-Dimethoxybenzidine .....................................................................................................................................................................
3,3′-Dimethylbenzidine ........................................................................................................................................................................
4,4′-Methylene bis(2-chloroaniline) ......................................................................................................................................................
Acetaldehyde .......................................................................................................................................................................................
Acrylamide ...........................................................................................................................................................................................
Acrylonitrile ..........................................................................................................................................................................................
Allyl chloride .........................................................................................................................................................................................
alpha-Hexachlorocyclohexane (a-HCH) ..............................................................................................................................................
Aniline ..................................................................................................................................................................................................
Benzene ...............................................................................................................................................................................................
Benzidine .............................................................................................................................................................................................
Benzotrichloride ...................................................................................................................................................................................
Benzyl chloride ....................................................................................................................................................................................
beta-Hexachlorocyclohexane (b-HCH) ................................................................................................................................................
Bis(2-ethylhexyl)phthalate ....................................................................................................................................................................
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
PO 00000
Frm 00034
Fmt 4701
Sfmt 4700
E:\FR\FM\25FER2.SGM
25FER2
79–34–5
79–00–5
57–14–7
96–12–8
122–66–7
106–99–0
542–75–6
123–91–1
88–06–2
25321–14–6
121–14–2
95–80–7
79–46–9
91–94–1
119–90–4
119–93–7
101–14–4
75–07–0
79–06–1
107–13–1
107–05–1
319–84–6
62–53–3
71–43–2
92–87–5
98–07–7
100–44–7
319–85–7
117–81–7
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
10861
TABLE 8 TO SUBPART KKKK OF PART 63—LIST OF HAZARDOUS AIR POLLUTANTS THAT MUST BE COUNTED TOWARD
TOTAL ORGANIC HAP CONTENT IF PRESENT AT 0.1 PERCENT OR MORE BY MASS—Continued
Chemical name
CAS No.
Bis(chloromethyl)ether .........................................................................................................................................................................
Bromoform ...........................................................................................................................................................................................
Captan .................................................................................................................................................................................................
Carbon tetrachloride ............................................................................................................................................................................
Chlordane ............................................................................................................................................................................................
Chlorobenzilate ....................................................................................................................................................................................
Chloroform ...........................................................................................................................................................................................
Chloroprene .........................................................................................................................................................................................
Cresols (mixed) ....................................................................................................................................................................................
DDE .....................................................................................................................................................................................................
Dichloroethyl ether ...............................................................................................................................................................................
Dichlorvos ............................................................................................................................................................................................
Epichlorohydrin ....................................................................................................................................................................................
Ethyl acrylate .......................................................................................................................................................................................
Ethylene dibromide ..............................................................................................................................................................................
Ethylene dichloride ..............................................................................................................................................................................
Ethylene oxide .....................................................................................................................................................................................
Ethylene thiourea .................................................................................................................................................................................
Ethylidene dichloride (1,1-Dichloroethane) ..........................................................................................................................................
Formaldehyde ......................................................................................................................................................................................
Heptachlor ............................................................................................................................................................................................
Hexachlorobenzene .............................................................................................................................................................................
Hexachlorobutadiene ...........................................................................................................................................................................
Hexachloroethane ................................................................................................................................................................................
Hydrazine .............................................................................................................................................................................................
Isophorone ...........................................................................................................................................................................................
Lindane (hexachlorocyclohexane, all isomers) ...................................................................................................................................
m-Cresol ..............................................................................................................................................................................................
Methylene chloride ...............................................................................................................................................................................
Naphthalene .........................................................................................................................................................................................
Nitrobenzene ........................................................................................................................................................................................
Nitrosodimethylamine ..........................................................................................................................................................................
o-Cresol ...............................................................................................................................................................................................
o-Toluidine ...........................................................................................................................................................................................
Parathion ..............................................................................................................................................................................................
p-Cresol ...............................................................................................................................................................................................
p-Dichlorobenzene ...............................................................................................................................................................................
Pentachloronitrobenzene .....................................................................................................................................................................
Pentachlorophenol ...............................................................................................................................................................................
Propoxur ..............................................................................................................................................................................................
Propylene dichloride ............................................................................................................................................................................
Propylene oxide ...................................................................................................................................................................................
Quinoline ..............................................................................................................................................................................................
Tetrachloroethene ................................................................................................................................................................................
Toxaphene ...........................................................................................................................................................................................
Trichloroethylene .................................................................................................................................................................................
Trifluralin ..............................................................................................................................................................................................
Vinyl bromide .......................................................................................................................................................................................
Vinyl chloride .......................................................................................................................................................................................
Vinylidene chloride ...............................................................................................................................................................................
Subpart SSSS—National Emission
Standards for Hazardous Air
Pollutants: Surface Coating of Metal
Coil
28. Section 63.5090 is amended by
revising paragraph (a) and adding
paragraph (e) to read as follows:
jbell on DSKJLSW7X2PROD with RULES2
■
§ 63.5090
Does this subpart apply to me?
(a) The provisions of this subpart
apply to each facility that is a major
source of HAP, as defined in § 63.2, at
which a coil coating line is operated,
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
except as provided in paragraphs (b)
and (e) of this section.
*
*
*
*
*
(e) This subpart does not apply to the
application of incidental markings
(including letters, numbers, or symbols)
that are added to bare metal coils and
that are used for only product
identification or for product inventory
control. The application of letters,
numbers, or symbols to a coated metal
coil is considered a coil coating process
and part of the coil coating affected
source.
PO 00000
Frm 00035
Fmt 4701
Sfmt 4700
542–88–1
75–25–2
133–06–2
56–23–5
57–74–9
510–15–6
67–66–3
126–99–8
1319–77–3
3547–04–4
111–44–4
62–73–7
106–89–8
140–88–5
106–93–4
107–06–2
75–21–8
96–45–7
75–34–3
50–00–0
76–44–8
118–74–1
87–68–3
67–72–1
302–01–2
78–59–1
58–89–9
108–39–4
75–09–2
91–20–3
98–95–3
62–75–9
95–48–7
95–53–4
56–38–2
106–44–5
106–46–7
82–68–8
87–86–5
114–26–1
78–87–5
75–56–9
91–22–5
127–18–4
8001–35–2
79–01–6
1582–09–8
593–60–2
75–01–4
75–35–4
29. Section 63.5110 is amended by
removing the definition for ‘‘Deviation’’
and adding definitions for ‘‘Deviation,
before’’ and ‘‘Deviation, on and after’’ in
alphabetical order to read as follows:
■
§ 63.5110 What special definitions are
used in this subpart?
*
*
*
*
*
Deviation, before August 24, 2020,
means any instance in which an affected
source, subject to this subpart, or an
owner or operator of such a source:
(1) Fails to meet any requirement or
obligation established by this subpart
including, but not limited to, any
E:\FR\FM\25FER2.SGM
25FER2
10862
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
emission limitation (including any
operating limit) or work practice
standard; or
(2) Fails to meet any term or condition
that is adopted to implement an
applicable requirement in this subpart
and that is included in the operating
permit for any affected source required
to obtain such a permit; or
(3) Fails to meet any emission
limitation (including any operating
limit) or work practice standard in this
subpart during start-up, shutdown, or
malfunction, regardless of whether or
not such failure is permitted by this
subpart.
Deviation, on and after August 24,
2020, means any instance in which an
affected source, subject to this subpart,
or an owner or operator of such a
source:
(1) Fails to meet any requirement or
obligation established by this subpart
including, but not limited to, any
emission limitation (including any
operating limit) or work practice
standard; or
(2) Fails to meet any term or condition
that is adopted to implement an
applicable requirement in this subpart
and that is included in the operating
permit for any affected source required
to obtain such a permit.
*
*
*
*
*
■ 30. Section 63.5121 is amended by
revising paragraph (a) to read as follows:
§ 63.5121
meet?
What operating limits must I
(a) Except as provided in paragraph
(b) of this section, for any coil coating
line for which you use an add-on
control device, unless you use a solvent
recovery system and conduct a liquidliquid material balance according to
§ 63.5170(e)(1), you must meet the
applicable operating limits specified in
Table 1 to this subpart. You must
establish the operating limits during
performance tests according to the
requirements in § 63.5160(d)(3) and
Table 1 to § 63.5160. You must meet the
operating limits established during the
most recent performance test required in
§ 63.5160 at all times after you establish
them.
*
*
*
*
*
■ 31. Section 63.5130 is amended by
revising paragraph (a) to read as follows:
§ 63.5130
When must I comply?
(a) For an existing affected source, the
compliance date is June 10, 2005.
*
*
*
*
*
■ 32. Section 63.5140 is amended by:
■ a. Revising paragraph (a);
■ b. Redesignating paragraph (b) as (c);
and
■ c. Adding paragraph (b).
The revision and addition read as
follows:
§ 63.5140 What general requirements must
I meet to comply with the standards?
(a) Before August 24, 2020, you must
be in compliance with the applicable
emission standards in § 63.5120 and the
operating limits in Table 1 to this
subpart at all times, except during
periods of start-up, shutdown, and
malfunction of any capture system and
control device used to comply with this
subpart. On and after August 24, 2020
you must be in compliance with the
applicable emission standards in
§ 63.5120 and the operating limits in
Table 1 to this subpart at all times. If
you are complying with the emission
standards of this subpart without the
use of a capture system and control
device, you must be in compliance with
the standards at all times.
(b) Before August 24, 2020, you must
always operate and maintain your
affected source, including air pollution
control and monitoring equipment,
according to the provisions in
§ 63.6(e)(1). On and after August 24,
2020, at all times, you must operate and
maintain your affected source, including
associated air pollution control
equipment and monitoring equipment,
in a manner consistent with safety and
good air pollution control practices for
minimizing emissions. The general duty
to minimize emissions does not require
the owner or operator to make any
further efforts to reduce emissions if
levels required by the applicable
standard have been achieved.
Determination of whether a source is
operating in compliance with operation
and maintenance requirements will be
based on information available to the
Administrator that may include, but is
not limited to, monitoring results,
review of operation and maintenance
procedures, review of operation and
maintenance records, and inspection of
the affected source.
*
*
*
*
*
■ 33. Section 63.5150 is amended by
revising paragraph (a) introductory text,
paragraph (a)(4)(i), and paragraph (b) to
read as follows:
§ 63.5150 If I use a control device to
comply with the emission standards, what
monitoring must I do?
*
*
*
*
*
(a) To demonstrate continuing
compliance with the standards, you
must monitor and inspect each capture
system and each control device required
to comply with § 63.5120 following the
date on which the initial performance
test of the capture system and control
device is completed. You must install
and operate the monitoring equipment
as specified in paragraphs (a)(1) through
(4) of this section. On and after August
24, 2020, you must also maintain the
monitoring equipment at all times in
accordance with § 63.5140(b) and keep
the necessary parts readily available for
routine repairs of the monitoring
equipment.
*
*
*
*
*
(4) * * *
(i) The monitoring plan must identify
the operating parameter to be monitored
to ensure that the capture efficiency
measured during compliance tests is
maintained, explain why this parameter
is appropriate for demonstrating
ongoing compliance, and identify the
specific monitoring procedures.
*
*
*
*
*
(b) If an operating parameter
monitored in accordance with
paragraphs (a)(3) and (4) of this section
is out of the allowed range specified in
Table 1 to this subpart it will be
considered a deviation from the
operating limit.
■ 34. Section 63.5160 is amended by
revising Table 1 and paragraphs (b)(1)(i),
(b)(2), (b)(4), (c), (d) introductory text,
(d)(1) introductory text, (d)(1)(vi)
introductory text, (d)(1)(vii), (d)(2),
(d)(3) introductory text, (d)(3)(i)(A),
(d)(3)(ii)(D) introductory text, and (e)
introductory text to read as follows:
§ 63.5160 What performance tests must I
complete?
jbell on DSKJLSW7X2PROD with RULES2
TABLE 1 TO § 63.5160—REQUIRED PERFORMANCE TESTING SUMMARY
If you control HAP on your coil
coating line by:
You must:
1. Limiting HAP or Volatile matter
content of coatings.
Determine the HAP or volatile matter and solids content of coating materials according to the procedures in § 63.5160(b) and (c).
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
PO 00000
Frm 00036
Fmt 4701
Sfmt 4700
E:\FR\FM\25FER2.SGM
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
10863
TABLE 1 TO § 63.5160—REQUIRED PERFORMANCE TESTING SUMMARY—Continued
If you control HAP on your coil
coating line by:
You must:
2. Using a capture system and
add-on control device.
Except as specified in paragraph (a) of this section, conduct an initial performance test within 180 days of the applicable compliance date in § 63.5130, and conduct periodic performance tests within 5 years following the previous performance test, as follows: If you are not required to complete periodic performance tests as a requirement of renewing your facility’s operating permit under 40 CFR part 70 or 40 CFR part 71, you must conduct the first periodic performance test before March 25, 2023, unless you already have conducted a performance test on or after March 25, 2018; thereafter, you must conduct a performance
test no later than 5 years following the previous performance test. Operating limits must be confirmed or reestablished during
each performance test. If you are required to complete periodic performance tests as a requirement of renewing your facility’s
operating permit under 40 CFR part 70 or 40 CFR part 71, you must conduct the periodic testing in accordance with the terms
and schedule required by your permit conditions. For each performance test: (1) For each capture and control system, determine the destruction or removal efficiency of each control device according to § 63.5160(d) and the capture efficiency of each
capture system according to § 63.5160(e), and (2) confirm or re-establish the operating limits.
jbell on DSKJLSW7X2PROD with RULES2
*
*
*
*
*
(b) * * *
(1) * * *
(i) Count only those organic HAP in
Table 3 to this subpart that are
measured to be present at greater than
or equal to 0.1 weight percent and
greater than or equal to 1.0 weight
percent for other organic HAP
compounds.
*
*
*
*
*
(2) Method 24 in appendix A–7 of part
60. For coatings, you may determine the
total volatile matter content as weight
fraction of nonaqueous volatile matter
and use it as a substitute for organic
HAP, using Method 24 in appendix A–
7 of part 60. As an alternative to using
Method 24, you may use ASTM D2369–
10 (2015), ‘‘Test Method for Volatile
Content of Coatings’’ (incorporated by
reference, see § 63.14). The
determination of total volatile matter
content using a method specified in this
paragraph (b)(2) or as provided in
paragraph (b)(3) of this section may be
performed by the manufacturer of the
coating and the results provided to you.
*
*
*
*
*
(4) Formulation data. You may use
formulation data provided that the
information represents each organic
HAP in Table 3 to this subpart that is
present at a level equal to or greater than
0.1 percent and equal to or greater than
1.0 percent for other organic HAP
compounds in any raw material used,
weighted by the mass fraction of each
raw material used in the material.
Formulation data may be provided to
you by the manufacturer of the coating
material. In the event of any
inconsistency between test data
obtained with the test methods specified
in paragraphs (b)(1) through (3) of this
section and formulation data, the test
data will govern.
(c) Solids content and density. You
must determine the solids content and
the density of each coating material
applied. You may determine the volume
solids content using ASTM D2697–
03(2014) Standard Test Method for
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
Volume Nonvolatile Matter in Clear or
Pigmented Coatings (incorporated by
reference, see § 63.14) or ASTM D6093–
97 (2016) Standard Test Method for
Percent Volume Nonvolatile Matter in
Clear or Pigmented Coatings Using a
Helium Gas Pycnometer (incorporated
by reference, see § 63.14), or an EPA
approved alternative method. You must
determine the density of each coating
using ASTM D1475–13 ‘‘Standard Test
Method for Density of Liquid Coatings,
Inks, and Related Products’’
(incorporated by reference, see § 63.14)
or ASTM D2111–10 (2015) ‘‘Standard
Test Methods for Specific Gravity and
Density of Halogenated Organic
Solvents and Their Admixtures’’
(incorporated by reference, see § 63.14).
The solids determination using ASTM
D2697–03(2014) or ASTM D6093–97
(2016) and the density determination
using ASTM D1475–13 or ASTM 2111–
10 (2015) may be performed by the
manufacturer of the material and the
results provided to you. Alternatively,
you may rely on formulation data
provided by material providers to
determine the volume solids. In the
event of any inconsistency between test
data obtained with the ASTM test
methods specified in this section and
formulation data, the test data will
govern.
(d) Control device destruction or
removal efficiency. If you are using an
add-on control device, such as an
oxidizer, to comply with the standard in
§ 63.5120, you must conduct
performance tests according to Table 1
to § 63.5160 to establish the destruction
or removal efficiency of the control
device or the outlet HAP concentration
achieved by the oxidizer, according to
the methods and procedures in
paragraphs (d)(1) and (2) of this section.
During performance tests, you must
establish the operating limits required
by § 63.5121 according to paragraph
(d)(3) of this section.
(1) Performance tests conducted to
determine the destruction or removal
efficiency of the control device must be
PO 00000
Frm 00037
Fmt 4701
Sfmt 4700
performed such that control device inlet
and outlet testing is conducted
simultaneously. To determine the outlet
organic HAP concentration achieved by
the oxidizer, only oxidizer outlet testing
must be conducted. The data must be
reduced in accordance with the test
methods and procedures in paragraphs
(d)(1)(i) through (ix).
*
*
*
*
*
(vi) Method 25 or 25A in appendix A–
7 of part 60 is used to determine total
gaseous non-methane organic matter
concentration. You may use Method 18
in appendix A–6 of part 60 to subtract
methane emissions from measured total
gaseous organic mass emissions as
carbon. Use the same test method for
both the inlet and outlet measurements,
which must be conducted
simultaneously. You must submit
notification of the intended test method
to the Administrator for approval along
with notification of the performance test
required under § 63.7 (b). You must use
Method 25A if any of the conditions
described in paragraphs (d)(1)(vi)(A)
through (D) of this section apply to the
control device.
*
*
*
*
*
(vii) Each performance test must
consist of three separate runs, except as
provided by § 63.7(e)(3); each run must
be conducted for at least 1 hour under
the conditions that exist when the
affected source is operating under
normal operating conditions. For the
purpose of determining volatile organic
matter concentrations and mass flow
rates, the average of the results of all
runs will apply. If you are
demonstrating compliance with the
outlet organic HAP concentration limit
in § 63.5120(a)(3), only the average
outlet volatile organic matter
concentration must be determined.
*
*
*
*
*
(2) You must record such process
information as may be necessary to
determine the conditions in existence at
the time of the performance test. Before
August 24, 2020, operations during
periods of start-up, shutdown, and
E:\FR\FM\25FER2.SGM
25FER2
10864
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
malfunction will not constitute
representative conditions for the
purpose of a performance test. On and
after August 24, 2020, you must conduct
the performance test under
representative operating conditions for
the coating operation. Operations during
periods of start-up, shutdown, or
nonoperation do not constitute
representative conditions for the
purpose of a performance test. The
owner or operator may not conduct
performance tests during periods of
malfunction. You must record the
process information that is necessary to
document operating conditions during
the test and explain why the conditions
represent normal operation. Upon
request, you must make available to the
Administrator such records as may be
necessary to determine the conditions of
performance tests.
(3) Operating limits. If you are using
a capture system and add-on control
device other than a solvent recovery
system for which you conduct a liquidliquid material balance to comply with
the requirements in § 63.5120, you must
establish the applicable operating limits
required by § 63.5121. These operating
limits apply to each capture system and
to each add-on emission control device
that is not monitored by CEMS, and you
must establish the operating limits
during performance tests required by
paragraph (d) of this section according
to the requirements in paragraphs
(d)(3)(i) through (iii) of this section.
(i) * * *
(A) During performance tests, you
must monitor and record the
combustion temperature at least once
every 15 minutes during each of the
three test runs. You must monitor the
temperature in the firebox of the
thermal oxidizer or immediately
downstream of the firebox before any
substantial heat exchange occurs.
*
*
*
*
*
(ii) * * *
(D) You must develop and implement
an inspection and maintenance plan for
your catalytic oxidizer(s) for which you
elect to monitor according to paragraph
(d)(3)(ii)(C) of this section. The plan
must address, at a minimum, the
elements specified in paragraphs
(d)(3)(ii)(D) (1) through (3) of this
section.
*
*
*
*
*
(e) Capture efficiency. If you are
required to determine capture efficiency
to meet the requirements of
§ 63.5170(e)(2), (f)(1) and (2), (g)(2)
through (4), or (i)(2) and (3), you must
determine capture efficiency using the
procedures in paragraph (e)(1), (2), or (3)
of this section, as applicable.
*
*
*
*
*
35. Section 63.5170 is amended by
revising Table 1 and paragraphs (c)(1)
and (2), (c)(4) introductory text, (e)(2)
introductory text, (f)(1) introductory
text, (f)(2), (g)(2) introductory text, (g)(3)
introductory text, (g)(4) introductory
text, Equation 11 of paragraph (h)(6), (i)
introductory text, and (i)(1) to read as
follows:
■
§ 63.5170 How do I demonstrate
compliance with the standards?
*
*
*
*
*
TABLE 1 TO § 63.5170—COMPLIANCE DEMONSTRATION REQUIREMENTS INDEX
If you choose to demonstrate compliance by:
Then you must demonstrate that:
1. Use of ‘‘as purchased’’ compliant coatings ....
a. Each coating material used during the 12-month compliance period does not exceed 0.046
kg HAP per liter solids, as purchased. Paragraph (a) of this section.
a. Each coating material used does not exceed 0.046 kg HAP per liter solids on a rolling 12month average as applied basis, determined monthly. Paragraphs (b)(1) of this section; or
b. Average of all coating materials used does not exceed 0.046 kg HAP per liter solids on a
rolling 12-month average as applied basis, determined monthly. Paragraph (b)(2) of this
section.
Overall organic HAP control efficiency is at least 98 percent on a monthly basis for individual
or groups of coil coating lines; or overall organic HAP control efficiency is at least 98 percent during performance tests conducted according to Table 1 to § 63.5170 and operating
limits are achieved continuously for individual coil coating lines; or oxidizer outlet HAP concentration is no greater than 20 ppmv and there is 100-percent capture efficiency during
performance tests conducted according to Table 1 to § 63.5170 and operating limits are
achieved continuously for individual coil coating lines. Paragraph (c) of this section.
Average equivalent emission rate does not exceed 0.046 kg HAP per liter solids on a rolling
12-month average as applied basis, determined monthly. Paragraph (d) of this section.
2. Use of ‘‘as applied’’ compliant coatings ..........
3. Use of a capture system and control device ..
4. Use of a combination of compliant coatings
and control devices and maintaining an acceptable equivalent emission rate.
jbell on DSKJLSW7X2PROD with RULES2
*
*
*
*
*
(c) * * *
(1) If the affected source uses one
compliance procedure to limit organic
HAP emissions to the level specified in
§ 63.5120(a)(1) or (3) and has only
always-controlled work stations, then
you must demonstrate compliance with
the provisions of paragraph (e) of this
section when emissions from the
affected source are controlled by one or
more solvent recovery devices.
(2) If the affected source uses one
compliance procedure to limit organic
HAP emissions to the level specified in
§ 63.5120(a)(1) or (3) and has only
always-controlled work stations, then
you must demonstrate compliance with
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
the provisions of paragraph (f) of this
section when emissions are controlled
by one or more oxidizers.
*
*
*
*
*
(4) The method of limiting organic
HAP emissions to the level specified in
§ 63.5120(a)(3) is the installation and
operation of a PTE around each work
station and associated curing oven in
the coating line and the ventilation of
all organic HAP emissions from each
PTE to an oxidizer with an outlet
organic HAP concentration of no greater
than 20 ppmv on a dry basis. An
enclosure that meets the requirements
in § 63.5160(e)(1) is considered a PTE.
Compliance of the oxidizer with the
outlet organic HAP concentration limit
PO 00000
Frm 00038
Fmt 4701
Sfmt 4700
is demonstrated either through
continuous emission monitoring
according to paragraph (c)(4)(ii) of this
section or through performance tests
according to the requirements of
§ 63.5160(d) and Table 1 to § 63.5160. If
this method is selected, you must meet
the requirements of paragraph (c)(4)(i) of
this section to demonstrate continuing
achievement of 100 percent capture of
organic HAP emissions and either
paragraph (c)(4)(ii) or paragraph
(c)(4)(iii) of this section, respectively, to
demonstrate continuous compliance
with the oxidizer outlet organic HAP
concentration limit through continuous
E:\FR\FM\25FER2.SGM
25FER2
10865
emission monitoring or continuous
operating parameter monitoring:
*
*
*
*
*
(e) * * *
(2) Continuous emission monitoring of
control device performance. Use
continuous emission monitors to
demonstrate recovery efficiency,
conduct performance tests of capture
efficiency and volumetric flow rate, and
continuously monitor a site specific
operating parameter to ensure that
capture efficiency and volumetric flow
rate are maintained following the
procedures in paragraphs (e)(2)(i)
through (xi) of this section:
*
*
*
*
*
(f) * * *
(1) Continuous monitoring of capture
system and control device operating
parameters. Demonstrate compliance
through performance tests of capture
efficiency and control device efficiency
and continuous monitoring of capture
system and control device operating
parameters as specified in paragraphs
(f)(1)(i) through (xi) of this section:
*
*
*
*
*
(2) Continuous emission monitoring of
control device performance. Use
continuous emission monitors, conduct
performance tests of capture efficiency,
and continuously monitor a site specific
operating parameter to ensure that
capture efficiency is maintained.
Compliance must be demonstrated in
accordance with paragraph (e)(2) of this
section.
(g) * * *
(2) Solvent recovery system using
performance test and continuous
monitoring compliance demonstration.
For each solvent recovery system used
to control one or more coil coating
stations for which you choose to comply
by means of performance testing of
capture efficiency, continuous emission
monitoring of the control device, and
continuous monitoring of a capture
system operating parameter, each month
of the 12-month compliance period you
must meet the requirements of
paragraphs (g)(2)(i) and (ii) of this
section:
*
*
*
*
*
(3) Oxidizer using performance tests
and continuous monitoring of operating
parameters compliance demonstration.
For each oxidizer used to control
emissions from one or more work
stations for which you choose to
demonstrate compliance through
performance tests of capture efficiency,
control device efficiency, and
continuous monitoring of capture
system and control device operating
parameters, each month of the 12-month
compliance period you must meet the
requirements of paragraphs (g)(3)(i)
through (iii) of this section:
*
*
*
*
*
(4) Oxidizer using continuous
emission monitoring compliance
demonstration. For each oxidizer used
to control emissions from one or more
work stations for which you choose to
demonstrate compliance through
capture efficiency testing, continuous
emission monitoring of the control
device, and continuous monitoring of a
capture system operating parameter,
each month of the 12-month compliance
period you must meet the requirements
in paragraphs (g)(4)(i) and (ii) of this
section:
*
*
*
*
*
(h) * * *
(6) * * *
*
The revisions and addition read as
follows:
section. The start-up, shutdown, and
malfunction plan and start-up,
shutdown, and malfunction report are
no longer required on and after August
24, 2020.
*
*
*
*
*
(g) * * *
(2) * * *
(v) A statement that there were no
deviations from the applicable emission
limit in § 63.5120 or the applicable
operating limit(s) established according
to § 63.5121 during the reporting period,
and that no CEMS were inoperative,
inactive, malfunctioning, out-of-control,
repaired, or adjusted.
(h) You must submit, for each
deviation occurring at an affected source
where you are not using CEMS to
comply with the standards in this
subpart, the semi-annual compliance
report containing the information in
paragraphs (g)(2)(i) through (iv) of this
section and the information in
paragraphs (h)(1) through (4) of this
section:
*
*
*
*
*
(2) Before August 24, 2020, you must
provide information on the number,
duration, and cause of deviations
*
*
*
*
(i) Capture and control system
compliance demonstration procedures
using a CPMS for a coil coating line. If
you use an add-on control device, to
demonstrate compliance for each
capture system and each control device
through performance tests and
continuous monitoring of capture
system and control device operating
parameters, you must meet the
requirements in paragraphs (i)(1)
through (3) of this section.
(1) Conduct performance tests
according to the schedule in Table 1 to
§ 63.5160 to determine the control
device destruction or removal
efficiency, DRE, according to
§ 63.5160(d) and Table 1 to § 63.5160.
*
*
*
*
*
■ 36. Section 63.5180 is amended by:
■ a. Revising paragraphs (f) introductory
text and (f)(1);
■ b. Removing and reserving paragraph
(f)(2);
■ c. Revising paragraphs (g)(2)(v), (h)
introductory text, (h)(2) and (3);
■ d. Adding paragraph (h)(4); and
■ e. Revising paragraphs (i) introductory
text, (i)(1) through (4), (i)(6), and (i)(9).
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
§ 63.5180
What reports must I submit?
*
*
*
*
*
(f) Before August 24, 2020, you must
submit start-up, shutdown, and
malfunction reports as specified in
§ 63.10(d)(5) if you use a control device
to comply with this subpart.
(1) Before August 24, 2020, if your
actions during a start-up, shutdown, or
malfunction of an affected source
(including actions taken to correct a
malfunction) are not completely
consistent with the procedures specified
in the source’s start-up, shutdown, and
malfunction plan specified in § 63.6
(e)(3) and required before August 24,
2020, you must state such information
in the report. The start-up, shutdown, or
malfunction report will consist of a
letter containing the name, title, and
signature of the responsible official who
is certifying its accuracy, that will be
submitted to the Administrator.
Separate start-up, shutdown, or
malfunction reports are not required if
the information is included in the report
specified in paragraph (g) of this
PO 00000
Frm 00039
Fmt 4701
Sfmt 4700
E:\FR\FM\25FER2.SGM
25FER2
ER25FE20.001
jbell on DSKJLSW7X2PROD with RULES2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
jbell on DSKJLSW7X2PROD with RULES2
10866
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
(including unknown cause, if
applicable) as applicable, and the
corrective action taken. On and after
August 24, 2020, you must provide
information on the number, date, time,
duration, and cause of deviations from
an emission limit in § 63.5120 or any
applicable operating limit established
according to § 63.5121 (including
unknown cause, if applicable) as
applicable, and the corrective action
taken.
(3) Before August 24, 2020, you must
provide information on the number,
duration, and cause for continuous
parameter monitoring system downtime
incidents (including unknown cause
other than downtime associated with
zero and span and other daily
calibration checks, if applicable). On
and after August 24, 2020, you must
provide the information specified in
paragraphs (h)(3)(i) and (ii) of this
section.
(i) Number, date, time, duration,
cause (including unknown cause), and
descriptions of corrective actions taken
for continuous parameter monitoring
systems that are inoperative (except for
zero (low-level) and high-level checks).
(ii) Number, date, time, duration,
cause (including unknown cause), and
descriptions of corrective actions taken
for continuous parameter monitoring
systems that are out of control as
specified in § 63.8(c)(7).
(4) On and after August 24, 2020, for
each deviation from an emission limit in
§ 63.5120 or any applicable operating
limit established according to § 63.5121,
you must provide a list of the affected
source or equipment, an estimate of the
quantity of each regulated pollutant
emitted over any emission limit in
§ 63.5120, a description of the method
used to estimate the emissions, and the
actions you took to minimize emissions
in accordance with § 63.5140(b).
(i) You must submit, for each
deviation from the applicable emission
limit in § 63.5120 or the applicable
operation limit(s) established according
to § 63.5121 occurring at an affected
source where you are using CEMS to
comply with the standards in this
subpart, the semi-annual compliance
report containing the information in
paragraphs (g)(2)(i) through (iv) of this
section, and the information in
paragraphs (i)(1) through (12) of this
section:
(1) The date and time that each
malfunction of the capture system or
add-on control devices started and
stopped.
(2) Before August 24, 2020, the date
and time that each CEMS was
inoperative, except for zero (low-level)
and high-level checks. On and after
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
August 24, 2020, for each instance that
the CEMS was inoperative, except for
zero (low-level) and high-level checks,
the date, time, and duration that the
CEMS was inoperative; the cause
(including unknown cause) for the
CEMS being inoperative; and a
description of corrective actions taken.
(3) Before August 24, 2020, the date
and time that each CEMS was out-ofcontrol, including the information in
§ 63.8(c)(8). On and after August 24,
2020, for each instance that the CEMS
was out-of-control, as specified in
§ 63.8(c)(7), the date, time, and duration
that the CEMS was out-of-control; the
cause (including unknown cause) for
the CEMS being out-of-control; and
descriptions of corrective actions taken.
(4) Before August 24, 2020, the date
and time that each deviation started and
stopped, and whether each deviation
occurred during a period of start-up,
shutdown, or malfunction or during
another period. On and after August 24,
2020, the date, time, and duration of
each deviation from an emission limit in
§ 63.5120. For each deviation, an
estimate of the quantity of each
regulated pollutant emitted over any
emission limit in § 63.5120 to this
subpart, and a description of the method
used to estimate the emissions.
*
*
*
*
*
(6) Before August 24, 2020, a
breakdown of the total duration of the
deviations during the reporting period
into those that are due to start-up,
shutdown, control equipment problems,
process problems, other known causes,
and other unknown causes. On and after
August 24, 2020, a breakdown of the
total duration of the deviations during
the reporting period into those that are
due to control equipment problems,
process problems, other known causes,
and other unknown causes.
*
*
*
*
*
(9) Before August 24, 2020, a brief
description of the metal coil coating
line. On and after August 24, 2020, a list
of the affected source or equipment,
including a brief description of the
metal coil coating line.
*
*
*
*
*
■ 37. Section 63.5181 is added to read
as follows:
§ 63.5181 What are my electronic reporting
requirements?
(a) Beginning no later than August 24,
2020, you must submit the results of
each performance test as required in
§ 63.5180(e) following the procedure
specified in paragraphs (a)(1) through
(3) of this section.
(1) For data collected using test
methods supported by the EPA’s
PO 00000
Frm 00040
Fmt 4701
Sfmt 4700
Electronic Reporting Tool (ERT) as
listed on the EPA’s ERT website
(https://www.epa.gov/electronicreporting-air-emissions/electronicreporting-tool-ert) at the time of the test,
you must submit the results of the
performance test to the EPA via the
Compliance and Emissions Data
Reporting Interface (CEDRI). The CEDRI
interface can be accessed through the
EPA’s Central Data Exchange (CDX)
(https://cdx.epa.gov/). Performance test
data must be submitted in a file format
generated through the use of the EPA’s
ERT or an alternate electronic file
format consistent with the extensible
markup language (XML) schema listed
on the EPA’s ERT website.
(2) For data collected using test
methods that are not supported by the
EPA’s ERT as listed on the EPA’s ERT
website at the time of the test, you must
submit the results of the performance
test in portable document format (PDF)
using the attachment module of the
ERT.
(3) If you claim that some of the
performance test information being
submitted under paragraph (a)(1) of this
section is confidential business
information (CBI), you must submit a
complete file generated through the use
of the EPA’s ERT or an alternate
electronic file consistent with the XML
schema listed on the EPA’s ERT
website, including information claimed
to be CBI, on a compact disc, flash drive
or other commonly used electronic
storage medium to the EPA. The
electronic medium must be clearly
marked as CBI and mailed to U.S. EPA/
OAQPS/CORE CBI Office, Attention:
Group Leader, Measurement Policy
Group, MD C404–02, 4930 Old Page Rd.,
Durham, NC 27703. The same ERT or
alternate file with the CBI omitted must
be submitted to the EPA via the EPA’s
CDX as described in paragraph (a)(1) of
this section.
(b) Beginning on August 24, 2020, the
owner or operator shall submit the
initial notifications required in § 63.9(b)
and the notification of compliance
status required in §§ 63.9(h) and
63.5180(d) to the EPA via the CEDRI.
The CEDRI interface can be accessed
through the EPA’s CDX (https://
cdx.epa.gov). The owner or operator
must upload to CEDRI an electronic
copy of each applicable notification in
PDF. The applicable notification must
be submitted by the deadline specified
in this subpart, regardless of the method
in which the reports are submitted.
Owners or operators who claim that
some of the information required to be
submitted via CEDRI is CBI shall submit
a complete report generated using the
appropriate form in CEDRI or an
E:\FR\FM\25FER2.SGM
25FER2
jbell on DSKJLSW7X2PROD with RULES2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
alternate electronic file consistent with
the XML schema listed on the EPA’s
CEDRI website, including information
claimed to be CBI, on a compact disc,
flash drive, or other commonly used
electronic storage medium to the EPA.
The electronic medium shall be clearly
marked as CBI and mailed to U.S. EPA/
OAQPS/CORE CBI Office, Attention:
Group Leader, Measurement Policy
Group, MD C404–02, 4930 Old Page Rd.,
Durham, NC 27703. The same file with
the CBI omitted shall be submitted to
the EPA via the EPA’s CDX as described
earlier in this paragraph.
(c) Beginning on March 25, 2021, or
once the reporting template has been
available on the CEDRI website for 1
year, whichever date is later, the owner
or operator shall submit the semiannual
compliance report required in
§ 63.5180(g) through (i), as applicable, to
the EPA via the CEDRI. The CEDRI
interface can be accessed through the
EPA’s CDX (https://cdx.epa.gov). The
owner or operator must use the
appropriate electronic template on the
CEDRI website for this subpart (https://
www.epa.gov/electronic-reporting-airemissions/compliance-and-emissionsdata-reporting-interface-cedri). The date
on which the report templates become
available will be listed on the CEDRI
website. If the reporting form for the
semiannual compliance report specific
to this subpart is not available in CEDRI
at the time that the report is due, you
must submit the report to the
Administrator at the appropriate
addresses listed in § 63.13. Once the
form has been available in CEDRI for 1
year, you must begin submitting all
subsequent reports via CEDRI. The
reports must be submitted by the
deadlines specified in this subpart,
regardless of the method in which the
reports are submitted. Owners or
operators who claim that some of the
information required to be submitted via
CEDRI is CBI shall submit a complete
report generated using the appropriate
form in CEDRI, including information
claimed to be CBI, on a compact disc,
flash drive, or other commonly used
electronic storage medium to the EPA.
The electronic medium shall be clearly
marked as CBI and mailed to U.S. EPA/
OAQPS/CORE CBI Office, Attention:
Group Leader, Measurement Policy
Group, MD C404–02, 4930 Old Page Rd.,
Durham, NC 27703. The same file with
the CBI omitted shall be submitted to
the EPA via the EPA’s CDX as described
earlier in this paragraph.
(d) If you are required to
electronically submit a report through
the CEDRI in the EPA’s CDX, you may
assert a claim of EPA system outage for
failure to timely comply with the
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
reporting requirement. To assert a claim
of EPA system outage, you must meet
the requirements outlined in paragraphs
(g)(1) through (7) of this section.
(1) You must have been or will be
precluded from accessing CEDRI and
submitting a required report within the
time prescribed due to an outage of
either the EPA’s CEDRI or CDX systems.
(2) The outage must have occurred
within the period of time beginning five
business days prior to the date that the
submission is due.
(3) The outage may be planned or
unplanned.
(4) You must submit notification to
the Administrator in writing as soon as
possible following the date you first
knew, or through due diligence should
have known, that the event may cause
or caused a delay in reporting.
(5) You must provide to the
Administrator a written description
identifying:
(i) The date(s) and time(s) when CDX
or CEDRI was accessed and the system
was unavailable;
(ii) A rationale for attributing the
delay in reporting beyond the regulatory
deadline to the EPA system outage;
(iii) Measures taken or to be taken to
minimize the delay in reporting; and
(iv) The date by which you propose to
report, or if you have already met the
reporting requirement at the time of the
notification, the date you reported.
(6) The decision to accept the claim
of EPA system outage and allow an
extension to the reporting deadline is
solely within the discretion of the
Administrator.
(7) In any circumstance, the report
must be submitted electronically as
soon as possible after the outage is
resolved.
(e) If you are required to electronically
submit a report through CEDRI in the
EPA’s CDX, you may assert a claim of
force majeure for failure to timely
comply with the reporting requirement.
To assert a claim of force majeure, you
must meet the requirements outlined in
paragraphs (h)(1) through (5) of this
section.
(1) You may submit a claim if a force
majeure event is about to occur, occurs,
or has occurred or there are lingering
effects from such an event within the
period of time beginning five business
days prior to the date the submission is
due. For the purposes of this section, a
force majeure event is defined as an
event that will be or has been caused by
circumstances beyond the control of the
affected facility, its contractors, or any
entity controlled by the affected facility
that prevents you from complying with
the requirement to submit a report
electronically within the time period
PO 00000
Frm 00041
Fmt 4701
Sfmt 4700
10867
prescribed. Examples of such events are
acts of nature (e.g., hurricanes,
earthquakes, or floods), acts of war or
terrorism, or equipment failure or safety
hazard beyond the control of the
affected facility (e.g., large scale power
outage).
(2) You must submit notification to
the Administrator in writing as soon as
possible following the date you first
knew, or through due diligence should
have known, that the event may cause
or has caused a delay in reporting.
(3) You must provide to the
Administrator:
(i) A written description of the force
majeure event;
(ii) A rationale for attributing the
delay in reporting beyond the regulatory
deadline to the force majeure event;
(iii) Measures taken or to be taken to
minimize the delay in reporting; and
(iv) The date by which you propose to
report, or if you have already met the
reporting requirement at the time of the
notification, the date you reported.
(4) The decision to accept the claim
of force majeure and allow an extension
to the reporting deadline is solely
within the discretion of the
Administrator.
(5) In any circumstance, the reporting
must occur as soon as possible after the
force majeure event occurs.
■ 38. Section 63.5190 is amended by
adding paragraphs (a)(5) and (c) to read
as follows:
§ 63.5190
What records must I maintain?
(a) * * *
(5) On and after August 24, 2020, for
each deviation from an emission
limitation reported under § 63.5180(h)
or (i), a record of the information
specified in paragraphs (a)(5)(i) through
(iv) of this section, as applicable.
(i) The date, time, and duration of the
deviation, as reported under
§ 63.5180(h) and (i).
(ii) A list of the affected sources or
equipment for which the deviation
occurred and the cause of the deviation,
as reported under § 63.5180(h) and (i).
(iii) An estimate of the quantity of
each regulated pollutant emitted over
any applicable emission limit in
§ 63.5120 to this subpart or any
applicable operating limit established
according to § 63.5121 to this subpart,
and a description of the method used to
calculate the estimate, as reported under
§ 63.5180(h) and (i).
(iv) A record of actions taken to
minimize emissions in accordance with
§ 63.5140(b) and any corrective actions
taken to return the affected unit to its
normal or usual manner of operation.
*
*
*
*
*
E:\FR\FM\25FER2.SGM
25FER2
10868
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
(c) Any records required to be
maintained by this subpart that are in
reports that were submitted
electronically via the EPA’s CEDRI may
be maintained in electronic format. This
ability to maintain electronic copies
does not affect the requirement for
39. Table 2 to subpart SSSS of part 63
is revised to read as follows:
■
Table 2 to Subpart SSSS of Part 63—
Applicability of General Provisions to
Subpart SSSS
You must comply with the applicable
General Provisions requirements
according to the following table:
General provisions reference
Subject
Applicable to subpart SSSS
§ 63.1(a)(1)–(4) ..............................
§ 63.1(a)(6) .....................................
§ 63.1(a)(10)–(12) ..........................
§ 63.1(b)(1) .....................................
General Applicability .....................
Source Category Listing ...............
Timing and Overlap Clarifications
Initial Applicability Determination ..
Yes.
Yes.
Yes.
Yes ................................................
§ 63.1(b)(3) .....................................
Applicability Determination Recordkeeping.
Applicability after Standard Established.
Applicability of Permit Program for
Area Sources.
Extensions and Notifications ........
Applicability of Permit Program
Before Relevant Standard is
Set.
Definitions .....................................
Yes.
Units and Abbreviations ...............
Prohibited Activities ......................
Circumvention/Fragmentation .......
Construction/Reconstruction .........
Requirements for Existing, Newly
Constructed, and Reconstructed Sources.
Application for Approval of Construction/Reconstruction.
Yes.
Yes.
Yes.
Yes.
Yes.
Yes.
§ 63.6(e)(3)(i), (e)(3)(iii)–(ix) ...........
Approval of Construction/Reconstruction.
Approval of Construction/Reconstruction Based on Prior State
Review.
Compliance with Standards and
Maintenance Requirements-Applicability.
Compliance Dates for New and
Reconstructed Sources.
Compliance Dates for Existing
Sources.
General Duty to Minimize Emissions and Requirement to Correct Malfunctions As Soon As
Possible.
Operation and Maintenance Requirements.
SSMP Requirements ....................
§ 63.6(f)(1) ......................................
SSM Exemption ............................
§ 63.6(f)(2)–(3) ...............................
Compliance with Non-Opacity
Emission Standards.
Alternative Non-Opacity Emission
Standard.
Compliance with Opacity/Visible
Emission Standards.
§ 63.1(c)(1) .....................................
§ 63.1(c)(2) .....................................
§ 63.1(c)(5) .....................................
§ 63.1(e) .........................................
§ 63.2 .............................................
§ 63.3 .............................................
§ 63.4(a)(1)–(2) ..............................
§ 63.4(b)–(c) ...................................
§ 63.5(a) .........................................
§ 63.5(b)(1), (3), (4), (6) .................
§ 63.5(d)(1)(i)–(ii)(F), (d)(1)(ii)(H),
(d)(1)(ii)(J), (d)(1)(iii), (d)(2)–(4).
§ 63.5(e) .........................................
§ 63.5(f) ..........................................
§ 63.6(a) .........................................
§ 63.6(b)(1)–(5), (b)(7) ...................
§ 63.6(c)(1), (2), (5) ........................
§ 63.6(e)(1)(i)–(ii) ...........................
§ 63.6(e)(1)(iii) ................................
§ 63.6(g) .........................................
§ 63.6(h) .........................................
§ 63.6(i)(1)–(14), (i)(16) ..................
jbell on DSKJLSW7X2PROD with RULES2
facilities to make records, data, and
reports available upon request to a
delegated air agency or the EPA as part
of an on-site compliance evaluation.
§ 63.7(a)–(d) except (a)(2)(i)–(viii)
§ 63.7(e)(1) .....................................
Extension of Compliance and Administrator’s Authority.
Presidential Compliance Exemption.
Performance Test Requirements
Performance Testing ....................
§ 63.7(e)(2)–(4) ..............................
§ 63.7(f) ..........................................
Conduct of Performance Tests ....
Alternative Test Method ...............
§ 63.6(j) ..........................................
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
PO 00000
Frm 00042
Fmt 4701
Explanation
Applicability to Subpart SSSS is
also specified in § 63.5090.
Yes.
Yes.
Yes.
Yes.
Yes ................................................
Yes ................................................
Additional definitions are specified
in § 63.5110.
Only total HAP emissions in terms
of tons per year are required for
§ 63.5(d)(1)(ii)(H).
Yes.
Yes.
Yes ................................................
Yes ................................................
Yes before August 24, 2020, No
on and after August 24, 2020.
Section 63.5130 specifies the
compliance dates.
Section 63.5130 specifies the
compliance dates.
See § 63.5140(b) for general duty
requirement.
Yes.
Yes before August 24, 2020, No
on and after August 24, 2020.
Yes before August 24, 2020, No
on and after August 24, 2020.
Yes.
See § 63.5140(b) for general duty
requirement.
Yes.
No .................................................
Subpart SSSS does not establish
opacity standards or visible
emission standards.
Yes.
Yes.
Yes.
Yes before August 24, 2020, No
on and after August 24, 2020.
Yes.
Yes ................................................
Sfmt 4700
E:\FR\FM\25FER2.SGM
See § 63.5160(d)(2).
EPA retains approval authority.
25FER2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
General provisions reference
Subject
§ 63.7(g)–(h) ...................................
Explanation
Data Analysis and Waiver of
Tests.
Monitoring Requirements—Applicability.
Yes.
§ 63.8(a)(4) .....................................
Additional Monitoring Requirements.
No .................................................
§ 63.8(b) .........................................
§ 63.8(c)(1) .....................................
Conduct of Monitoring ..................
Operation and Maintenance of
Continuous Monitoring System
(CMS).
Yes.
Yes before August 24, 2020, No
on and after August 24, 2020.
§ 63.8(c)(2)–(3) ..............................
CMS Operation and Maintenance
Yes ................................................
§ 63.8(c)(4)–(5) ..............................
CMS Continuous Operation Procedures.
CMS Requirements ......................
No .................................................
CMS Quality Control, Written Procedures, and Performance
Evaluation.
Use of an Alternative Monitoring
Method.
Alternative to Relative Accuracy
Test.
Yes ................................................
§ 63.8(g) .........................................
Data Reduction .............................
No .................................................
§ 63.9(a) .........................................
§ 63.9(b)(1) .....................................
§ 63.9(b)(2) .....................................
Notification of Applicability ............
Initial Notifications .........................
Initial Notifications .........................
Yes.
Yes.
Yes ................................................
§ 63.9(b)(4)(i), (b)(4)(v), (b)(5) .......
Application for Approval of Construction or Reconstruction.
Request for Extension of Compliance, New Source Notification
for Special Compliance Requirements, and Notification of
Performance Test.
Yes.
§ 63.9(f) ..........................................
Notification of Visible Emissions/
Opacity Test.
No .................................................
§ 63.9(g) .........................................
Additional Notifications When
Using CMS.
Notification of Compliance Status
No .................................................
Clarifications .................................
Adjustment of Submittal Deadlines.
Change in Previous Information ...
Recordkeeping/Reporting—Applicability and General Information.
General Recordkeeping Requirements.
Recordkeeping of Occurrence and
Duration of Startups and Shutdowns and Recordkeeping of
Failures to Meet Standards.
Maintenance Records ...................
Yes.
Yes.
§ 63.8(a)(1)–(2) ..............................
§ 63.8(c)(6)–(8) ..............................
§ 63.8(d)–(e) ...................................
§ 63.8(f)(1)–(5) ...............................
§ 63.8(f)(6) ......................................
§ 63.9(c)–(e) ...................................
§ 63.9(h)(1)–(3) ..............................
§ 63.9(h)(5)–(6) ..............................
§ 63.9(i) ..........................................
§ 63.9(j) ..........................................
§ 63.10(a) .......................................
jbell on DSKJLSW7X2PROD with RULES2
Applicable to subpart SSSS
§ 63.10(b)(1) ...................................
§ 63.10(b)(2)(i)–(ii) ..........................
§ 63.10(b)(2)(iii) ..............................
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
PO 00000
Frm 00043
Fmt 4701
10869
Yes ................................................
Yes ................................................
Additional requirements for monitoring are specified in
§ 63.5150(a).
Subpart SSSS does not have
monitoring requirements for
flares.
Section 63.5150(a) specifies the
requirements for the operation
of CMS for capture systems
and add-on control devices at
sources using these to comply.
Applies only to monitoring of capture system and add-on control
device efficiency at sources
using these to comply with the
standards. Additional requirements for CMS operations and
maintenance are specified in
§ 63.5170.
Subpart SSSS does not require
COMS.
Provisions only apply if CEMS are
used.
Provisions only apply if CEMS are
used.
Yes ................................................
EPA retains approval authority.
No .................................................
Section 63.8(f)(6) provisions are
not applicable because subpart
SSSS does not require CEMS.
Sections 63.5170, 63.5140,
63.5150, and 63.5150 specify
monitoring data reduction.
Yes ................................................
Yes ................................................
With the exception that
§ 63.5180(b)(1) provides 2
years after the proposal date
for submittal of the initial notification for existing sources.
Notification of performance test
requirement applies only to
capture system and add-on
control device performance
tests at sources using these to
comply with the standards.
Subpart SSSS does not require
opacity and visible emissions
observations.
Provisions for COMS are not applicable.
Section 63.5130 specifies the
dates for submitting the notification of compliance status.
Yes.
Yes.
Yes ................................................
Yes before August 24, 2020, No
on and after August 24, 2020.
Additional requirements are specified in § 63.5190.
See § 63.5190(a)(5).
Yes.
Sfmt 4700
E:\FR\FM\25FER2.SGM
25FER2
10870
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
General provisions reference
Subject
§ 63.10(b)(2)(iv)–(v) .......................
Actions Taken to Minimize Emissions During Startup, Shutdown, and Malfunction.
Recordkeeping for CMS Malfunctions.
Other CMS Requirements ............
Recordkeeping Requirements for
Applicability Determinations.
Additional CMS Recordkeeping
Requirements.
General Reporting Requirements
and Report of Performance
Test Results.
Reporting Opacity or Visible
Emissions Observations.
Yes before August 24, 2020, No
on and after August 24, 2020.
See § 63.5190(a)(5).
Yes before August 24, 2020, No
on and after August 24, 2020.
Yes.
Yes.
See § 63.5190(a)(5).
No .................................................
See § 63.5190(a)(5).
Yes ................................................
Additional requirements are specified in § 63.5180(e).
No .................................................
Subpart SSSS does not require
opacity and visible emissions
observations.
Yes.
§ 63.12 ...........................................
§ 63.13(a) .......................................
Progress Reports for Sources
with Compliance Extensions.
Startup, Shutdown, Malfunction
Reports.
Additional Reporting Requirements for Sources with CMS.
Recordkeeping/Reporting Waiver
Control Device Requirements/
Flares.
State Authority and Delegations ...
Addresses .....................................
§ 63.13(b) .......................................
§ 63.13(c) .......................................
Submittal to State Agencies .........
Submittal to State Agencies .........
§ 63.14 ...........................................
Incorporation by Reference ..........
§ 63.15 ...........................................
Availability of Information/Confidentiality.
§ 63.10(b)(2)(vi) ..............................
§ 63.10(b)(2)(vii)–(xiv) ....................
§ 63.10(b)(3) ...................................
§ 63.10(c) .......................................
§ 63.10(d)(1)–(2) ............................
§ 63.10(d)(3) ...................................
§ 63.10(d)(4) ...................................
§ 63.10(d)(5) ...................................
§ 63.10(e) .......................................
§ 63.10(f) ........................................
§ 63.11 ...........................................
Applicable to subpart SSSS
Explanation
Yes before August 24, 2020, No
on and after August 24, 2020.
No.
Yes.
No .................................................
Yes.
Yes before August 24, 2020, No
on and after August 24, 2020.
Yes.
Yes before August 24, 2020, No
unless the state requires the
submittal via CEDRI, on and
after August 24, 2020.
Yes ................................................
Subpart SSSS does not specify
use of flares for compliance.
Subpart SSSS includes provisions
for alternative ASTM and ASME
test methods that are incorporated by reference.
Yes.
40. Table 3 to subpart SSSS of part 63
is added to read as follows:
■
TABLE 3 TO SUBPART SSSS OF PART 63—LIST OF HAZARDOUS AIR POLLUTANTS THAT MUST BE COUNTED TOWARD
TOTAL ORGANIC HAP CONTENT IF PRESENT AT 0.1 PERCENT OR MORE BY MASS
jbell on DSKJLSW7X2PROD with RULES2
Chemical name
CAS No.
1,1,2,2-Tetrachloroethane ..............................................................................................................................................................
1,1,2-Trichloroethane .....................................................................................................................................................................
1,1-Dimethylhydrazine ...................................................................................................................................................................
1,2-Dibromo-3-chloropropane ........................................................................................................................................................
1,2-Diphenylhydrazine ...................................................................................................................................................................
1,3-Butadiene .................................................................................................................................................................................
1,3-Dichloropropene ......................................................................................................................................................................
1,4-Dioxane ....................................................................................................................................................................................
2,4,6-Trichlorophenol .....................................................................................................................................................................
2,4/2,6-Dinitrotoluene (mixture) .....................................................................................................................................................
2,4-Dinitrotoluene ...........................................................................................................................................................................
2,4-Toluene diamine ......................................................................................................................................................................
2-Nitropropane ...............................................................................................................................................................................
3,3′-Dichlorobenzidine ...................................................................................................................................................................
3,3′-Dimethoxybenzidine ...............................................................................................................................................................
3,3′-Dimethylbenzidine ..................................................................................................................................................................
4,4′-Methylene bis(2-chloroaniline) ................................................................................................................................................
Acetaldehyde .................................................................................................................................................................................
Acrylamide .....................................................................................................................................................................................
Acrylonitrile ....................................................................................................................................................................................
Allyl chloride ...................................................................................................................................................................................
alpha-Hexachlorocyclohexane (a-HCH) ........................................................................................................................................
Aniline ............................................................................................................................................................................................
Benzene .........................................................................................................................................................................................
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
PO 00000
Frm 00044
Fmt 4701
Sfmt 4700
E:\FR\FM\25FER2.SGM
25FER2
79–34–5
79–00–5
57–14–7
96–12–8
122–66–7
106–99–0
542–75–6
123–91–1
88–06–2
25321–14–6
121–14–2
95–80–7
79–46–9
91–94–1
119–90–4
119–93–7
101–14–4
75–07–0
79–06–1
107–13–1
107–05–1
319–84–6
62–53–3
71–43–2
Federal Register / Vol. 85, No. 37 / Tuesday, February 25, 2020 / Rules and Regulations
10871
TABLE 3 TO SUBPART SSSS OF PART 63—LIST OF HAZARDOUS AIR POLLUTANTS THAT MUST BE COUNTED TOWARD
TOTAL ORGANIC HAP CONTENT IF PRESENT AT 0.1 PERCENT OR MORE BY MASS—Continued
Chemical name
CAS No.
Benzidine .......................................................................................................................................................................................
Benzotrichloride .............................................................................................................................................................................
Benzyl chloride ..............................................................................................................................................................................
beta-Hexachlorocyclohexane (b-HCH) ..........................................................................................................................................
Bis(2-ethylhexyl)phthalate ..............................................................................................................................................................
Bis(chloromethyl)ether ...................................................................................................................................................................
Bromoform .....................................................................................................................................................................................
Captan ...........................................................................................................................................................................................
Carbon tetrachloride ......................................................................................................................................................................
Chlordane ......................................................................................................................................................................................
Chlorobenzilate ..............................................................................................................................................................................
Chloroform .....................................................................................................................................................................................
Chloroprene ...................................................................................................................................................................................
Cresols (mixed) ..............................................................................................................................................................................
DDE ...............................................................................................................................................................................................
Dichloroethyl ether .........................................................................................................................................................................
Dichlorvos ......................................................................................................................................................................................
Epichlorohydrin ..............................................................................................................................................................................
Ethyl acrylate .................................................................................................................................................................................
Ethylene dibromide ........................................................................................................................................................................
Ethylene dichloride ........................................................................................................................................................................
Ethylene oxide ...............................................................................................................................................................................
Ethylene thiourea ...........................................................................................................................................................................
Ethylidene dichloride (1,1-Dichloroethane) ....................................................................................................................................
Formaldehyde ................................................................................................................................................................................
Heptachlor ......................................................................................................................................................................................
Hexachlorobenzene .......................................................................................................................................................................
Hexachlorobutadiene .....................................................................................................................................................................
Hexachloroethane ..........................................................................................................................................................................
Hydrazine .......................................................................................................................................................................................
Isophorone .....................................................................................................................................................................................
Lindane (hexachlorocyclohexane, all isomers) .............................................................................................................................
m-Cresol ........................................................................................................................................................................................
Methylene chloride .........................................................................................................................................................................
Naphthalene ...................................................................................................................................................................................
Nitrobenzene ..................................................................................................................................................................................
Nitrosodimethylamine ....................................................................................................................................................................
o-Cresol .........................................................................................................................................................................................
o-Toluidine .....................................................................................................................................................................................
Parathion ........................................................................................................................................................................................
p-Cresol .........................................................................................................................................................................................
p-Dichlorobenzene .........................................................................................................................................................................
Pentachloronitrobenzene ...............................................................................................................................................................
Pentachlorophenol .........................................................................................................................................................................
Propoxur ........................................................................................................................................................................................
Propylene dichloride ......................................................................................................................................................................
Propylene oxide .............................................................................................................................................................................
Quinoline ........................................................................................................................................................................................
Tetrachloroethene ..........................................................................................................................................................................
Toxaphene .....................................................................................................................................................................................
Trichloroethylene ...........................................................................................................................................................................
Trifluralin ........................................................................................................................................................................................
Vinyl bromide .................................................................................................................................................................................
Vinyl chloride .................................................................................................................................................................................
Vinylidene chloride .........................................................................................................................................................................
[FR Doc. 2020–00303 Filed 2–24–20; 8:45 am]
jbell on DSKJLSW7X2PROD with RULES2
BILLING CODE 6560–50–P
VerDate Sep<11>2014
20:57 Feb 24, 2020
Jkt 250001
PO 00000
Frm 00045
Fmt 4701
Sfmt 9990
E:\FR\FM\25FER2.SGM
25FER2
92–87–5
98–07–7
100–44–7
319–85–7
117–81–7
542–88–1
75–25–2
133–06–2
56–23–5
57–74–9
510–15–6
67–66–3
126–99–8
1319–77–3
3547–04–4
111–44–4
62–73–7
106–89–8
140–88–5
106–93–4
107–06–2
75–21–8
96–45–7
75–34–3
50–00–0
76–44–8
118–74–1
87–68–3
67–72–1
302–01–2
78–59–1
58–89–9
108–39–4
75–09–2
91–20–3
98–95–3
62–75–9
95–48–7
95–53–4
56–38–2
106–44–5
106–46–7
82–68–8
87–86–5
114–26–1
78–87–5
75–56–9
91–22–5
127–18–4
8001–35–2
79–01–6
1582–09–8
593–60–2
75–01–4
75–35–4
Agencies
[Federal Register Volume 85, Number 37 (Tuesday, February 25, 2020)]
[Rules and Regulations]
[Pages 10828-10871]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 2020-00303]
[[Page 10827]]
Vol. 85
Tuesday,
No. 37
February 25, 2020
Part II
Environmental Protection Agency
-----------------------------------------------------------------------
40 CFR Part 63
National Emission Standards for Hazardous Air Pollutants: Surface
Coating of Metal Cans and Surface Coating of Metal Coil Residual Risk
and Technology Reviews; Final Rule
Federal Register / Vol. 85 , No. 37 / Tuesday, February 25, 2020 /
Rules and Regulations
[[Page 10828]]
-----------------------------------------------------------------------
ENVIRONMENTAL PROTECTION AGENCY
40 CFR Part 63
[EPA-HQ-OAR-2017-0684, EPA-HQ-OAR-2017-0685; FRL-10003-81-OAR]
RIN 2060-AT51
National Emission Standards for Hazardous Air Pollutants: Surface
Coating of Metal Cans and Surface Coating of Metal Coil Residual Risk
and Technology Reviews
AGENCY: Environmental Protection Agency (EPA).
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: The U.S. Environmental Protection Agency (EPA) is taking final
action on the residual risk and technology reviews (RTRs) conducted for
the Surface Coating of Metal Cans and Surface Coating of Metal Coil
source categories regulated under national emission standards for
hazardous air pollutants (NESHAP). The EPA is also taking final action
on amendments for the two source categories to address emissions during
periods of startup, shutdown, and malfunction (SSM); electronic
reporting of performance test results and compliance reports; the
addition of EPA Method 18 and updates to several measurement methods;
and the addition of requirements for periodic performance testing.
Additionally, several miscellaneous technical amendments are being made
to improve the clarity of the rule requirements. We are making no
revisions to the numerical emission limits for the two source
categories based on the residual risk and technology reviews.
DATES: This final rule is effective on February 25, 2020. The
incorporation by reference (IBR) of certain publications listed in the
rule is approved by the Director of the Federal Register as of February
25, 2020.
ADDRESSES: The EPA has established dockets for this action under Docket
ID No. EPA-HQ-OAR-2017-0684 for 40 Code of Federal Regulations (CFR)
part 63, subpart KKKK, Surface Coating of Metal Cans, and Docket ID No.
EPA-HQ-OAR-2017-0685 for 40 CFR part 63, subpart SSSS, Surface Coating
of Metal Coil. All documents in the docket are listed on the https://www.regulations.gov/ website. Although listed, some information is not
publicly available, e.g., confidential business information (CBI) or
other information whose disclosure is restricted by statute. Certain
other material, such as copyrighted material, is not placed on the
internet and will be publicly available only in hard copy form.
Publicly available docket materials are available either electronically
through https://www.regulations.gov/, or in hard copy at the EPA Docket
Center, WJC West Building, Room Number 3334, 1301 Constitution Ave. NW,
Washington, DC. The Public Reading Room hours of operation are 8:30
a.m. to 4:30 p.m. Eastern Standard Time (EST), Monday through Friday.
The telephone number for the Public Reading Room is (202) 566-1744, and
the telephone number for the EPA Docket Center is (202) 566-1742.
FOR FURTHER INFORMATION CONTACT: For questions about this final action,
contact Ms. Paula Hirtz, Minerals and Manufacturing Group, Sector
Policies and Programs Division (D243-04), Office of Air Quality
Planning and Standards, U.S. Environmental Protection Agency, Research
Triangle Park, North Carolina 27711; telephone number: (919) 541-2618;
fax number: (919) 541-4991; and email address: [email protected]. For
specific information regarding the risk modeling methodology, contact
Mr. Chris Sarsony, Health and Environmental Impacts Division (C539-02),
Office of Air Quality Planning and Standards, U.S. Environmental
Protection Agency, Research Triangle Park, North Carolina 27711;
telephone number: (919) 541-4843; fax number: (919) 541-0840; and email
address: [email protected]. For information about the applicability
of these NESHAP to a particular entity, contact Mr. John Cox, Office of
Enforcement and Compliance Assurance, U.S. Environmental Protection
Agency, WJC South Building (Mail Code 2227A), 1200 Pennsylvania Avenue
NW, Washington, DC 20460; telephone number: (202) 564-1395; and email
address: [email protected].
SUPPLEMENTARY INFORMATION:
Preamble acronyms and abbreviations. We use multiple acronyms and
terms in this preamble. While this list may not be exhaustive, to ease
the reading of this preamble and for reference purposes, the EPA
defines the following terms and acronyms here:
ASTM American Society for Testing and Materials
BPA bisphenol A
BPA-NI not intentionally containing BPA
CAA Clean Air Act
CBI Confidential Business Information
CDX Central Data Exchange
CEDRI Compliance and Emissions Data Reporting Interface
CEMS continuous emissions monitoring systems
CFR Code of Federal Regulations
DGME diethylene glycol monobutyl ether
EPA Environmental Protection Agency
ERT Electronic Reporting Tool
HAP hazardous air pollutant(s)
HCl hydrochloric acid
HF hydrogen fluoride
HI hazard index
HQ hazard quotient
HQREL hazard quotient recommended exposure limit
IBR incorporation by reference
ICR Information Collection Request
kg kilogram
km kilometer
MACT maximum achievable control technology
MIR maximum individual risk
NAAQS National Ambient Air Quality Standards
NAICS North American Industry Classification System
NESHAP national emission standards for hazardous air pollutants
NSPS new source performance standard
NSR New Source Review
NTTAA National Technology Transfer and Advancement Act
OAQPS Office of Air Quality Planning and Standards
OMB Office of Management and Budget
OSHA Occupational Safety and Health Administration
PB-HAP hazardous air pollutants known to be persistent and bio-
accumulative in the environment
PDF portable document format
PRA Paperwork Reduction Act
PTE permanent total enclosure
REL reference exposure level
RFA Regulatory Flexibility Act
RTR residual risk and technology review
SSM startup, shutdown, and malfunction
TOSHI target organ-specific hazard index
tpy tons per year
[mu]g/m3 micrograms per cubic meter
UMRA Unfunded Mandates Reform Act
VCS voluntary consensus standards
Background information. On June 4, 2019, the EPA proposed revisions
to the Surface Coating of Metal Cans NESHAP and the Surface Coating of
Metal Coil NESHAP based on our RTRs. In this action, we are finalizing
decisions and revisions to the rules. In this preamble, we summarize
some of the more significant comments we timely received regarding the
proposed rule and provide our responses. A summary of all the public
comments on the proposed rules and the EPA's responses to those
comments is available in the ``Summary of Public Comments and Responses
for the Risk and Technology Reviews for the Surface Coating of Metal
Cans and the Surface Coating of Metal Coil NESHAP,'' in Docket ID Nos.
EPA-HQ-OAR-2017-0684 and EPA-HQ-OAR-2017-0685. A ``track changes''
version of the regulatory language that incorporates the changes in
this action is available in the docket for each rule.
Organization of this document. The information in this preamble is
organized as follows:
[[Page 10829]]
I. General Information
A. Does this action apply to me?
B. Where can I get a copy of this document and other related
information?
C. Judicial Review and Administrative Reconsideration
II. Background
A. What is the statutory authority for this action?
B. What are the source categories and how does the NESHAP
regulate HAP emissions from the source categories?
C. What changes did we propose for the source categories in our
June 4, 2019, RTR proposal?
III. What is included in these final rules?
A. What are the final rule amendments based on the risk reviews
for the Surface Coating of Metal Cans and Surface Coating of Metal
Coil source categories?
B. What are the final rule amendments based on the technology
reviews for the Surface Coating of Metal Cans and Surface Coating of
Metal Coil source categories?
C. What are the final rule amendments addressing emissions
during periods of SSM?
D. What other changes have been made to the NESHAP?
E. What are the effective and compliance dates of the revisions
to the standards?
F. What are the requirements for submission of performance test
data to the EPA?
IV. What is the rationale for our final decisions and amendments for
the Surface Coating of Metal Cans and Surface Coating of Metal Coil
source categories?
A. Residual Risk Reviews
B. Technology Reviews
C. Electronic Reporting Provisions
D. SSM Provisions
E. Ongoing Compliance Demonstrations
V. Summary of Cost, Environmental, and Economic Impacts and
Additional Analyses Conducted
A. What are the affected sources?
B. What are the air quality impacts?
C. What are the cost impacts?
D. What are the economic impacts?
E. What are the benefits?
F. What analysis of environmental justice did we conduct?
G. What analysis of children's environmental health did we
conduct?
VI. Statutory and Executive Order Reviews
A. Executive Order 12866: Regulatory Planning and Review and
Executive Order 13563: Improving Regulation and Regulatory Review
B. Executive Order 13771: Reducing Regulations and Controlling
Regulatory Costs
C. Paperwork Reduction Act (PRA)
D. Regulatory Flexibility Act (RFA)
E. Unfunded Mandates Reform Act (UMRA)
F. Executive Order 13132: Federalism
G. Executive Order 13175: Consultation and Coordination With
Indian Tribal Governments
H. Executive Order 13045: Protection of Children From
Environmental Health Risks and Safety Risks
I. Executive Order 13211: Actions Concerning Regulations That
Significantly Affect Energy Supply, Distribution, or Use
J. National Technology Transfer and Advancement Act (NTTAA) and
1 CFR Part 51
K. Executive Order 12898: Federal Actions To Address
Environmental Justice in Minority Populations and Low-Income
Populations
L. Congressional Review Act (CRA)
I. General Information
A. Does this action apply to me?
Regulated entities. Categories and entities potentially regulated
by this action are shown in Table 1 of this preamble.
Table 1--NESHAP and Industrial Source Categories Affected by This Final
Action
------------------------------------------------------------------------
NAICS \1\
NESHAP source category code Regulated entities \2\
------------------------------------------------------------------------
Surface Coating of Metal Cans..... 332431 Two-piece Beverage Can
Facilities, Three-piece
Food Can Facilities, Two-
piece Draw and Iron
Facilities, One-piece
Aerosol Can Facilities.
332115
332116
332812
332999
332431 Can Assembly Facilities.
332812 End Manufacturing
Facilities.
Surface Coating of Metal Coil..... 325992 Photographic Film, Paper,
Plate, and Chemical
Manufacturing.
326199 All Other Plastics
Product Manufacturing.
331110 Iron and Steel Mills and
Ferroalloy
Manufacturing.
331221 Rolled Steel Shape
Manufacturing.
331315 Aluminum Sheet, Plate,
and Foil Manufacturing.
331318 Other Aluminum Rolling,
Drawing, and Extruding.
331420 Copper Rolling, Drawing,
Extruding, and Alloying.
332311 Prefabricated Metal
Building and Component
Manufacturing.
332312 Fabricated Structural
Metal Manufacturing.
332322 Sheet Metal Work
Manufacturing.
\3\ Metal Coating, Engraving
332812 (except Jewelry and
Silverware), and Allied
Services to
Manufacturers.
332999 All Other Miscellaneous
Fabricated Metal Product
Manufacturing.
333249 Other Industrial
Machinery Manufacturing.
337920 Blind and Shade
Manufacturing.
------------------------------------------------------------------------
\1\ North American Industry Classification System.
\2\ Regulated entities are major source facilities that apply surface
coatings to these parts or products.
\3\ The majority of coil coating facilities are included in NAICS Code
332812.
Table 1 of this preamble is not intended to be exhaustive, but
rather to provide a guide for readers regarding entities likely to be
affected by the final action for the source categories listed. To
determine whether your facility is affected, you should examine the
applicability criteria in the appropriate NESHAP. If you have any
questions regarding the applicability of any aspect of these NESHAP,
please contact the appropriate person listed in the preceding FOR
FURTHER INFORMATION CONTACT section of this preamble.
B. Where can I get a copy of this document and other related
information?
In addition to being available in the dockets, an electronic copy
of this final action will also be available on the internet. Following
signature by the EPA Administrator, the EPA will post
[[Page 10830]]
copies of this final action at: https://www.epa.gov/stationary-sources-air-pollution/surface-coating-metal-cans-national-emission-standards-hazardous and https://www.epa.gov/stationary-sources-air-pollution/surface-coating-metal-coil-national-emission-standards-hazardous.
Following publication in the Federal Register, the EPA will post the
Federal Register version and key technical documents at these same
websites.
Additional information is available on the RTR website at https://www.epa.gov/stationary-sources-air-pollution/risk-and-technology-review-national-emissions-standards-hazardous. This information
includes an overview of the RTR program, links to project websites for
the RTR source categories, and detailed emissions data and other data
we used as inputs to the risk assessments.
C. Judicial Review and Administrative Reconsideration
Under Clean Air Act (CAA) section 307(b)(1), judicial review of
this final action is available only by filing a petition for review in
the United States Court of Appeals for the District of Columbia Circuit
(the Court) by April 27, 2020. Under CAA section 307(b)(2), the
requirements established by these final rules may not be challenged
separately in any civil or criminal proceedings brought by the EPA to
enforce the requirements.
Section 307(d)(7)(B) of the CAA further provides that only an
objection to a rule or procedure which was raised with reasonable
specificity during the period for public comment (including any public
hearing) may be raised during judicial review. This section also
provides a mechanism for the EPA to reconsider the rule if the person
raising an objection can demonstrate to the Administrator that it was
impracticable to raise such objection within the period for public
comment or if the grounds for such objection arose after the period for
public comment (but within the time specified for judicial review) and
if such objection is of central relevance to the outcome of the rule.
Any person seeking to make such a demonstration should submit a
Petition for Reconsideration to the Office of the Administrator, U.S.
EPA, Room 3000, WJC South Building, 1200 Pennsylvania Ave. NW,
Washington, DC 20460, with a copy to both the person(s) listed in the
preceding FOR FURTHER INFORMATION CONTACT section, and the Associate
General Counsel for the Air and Radiation Law Office, Office of General
Counsel (Mail Code 2344A), U.S. EPA, 1200 Pennsylvania Ave. NW,
Washington, DC 20460.
II. Background
A. What is the statutory authority for this action?
Section 112 of the CAA establishes a two-stage regulatory process
to address emissions of hazardous air pollutants (HAP) from stationary
sources. In the first stage, we must identify categories of sources
emitting one or more of the HAP listed in CAA section 112(b) and then
promulgate technology-based NESHAP for those sources. ``Major sources''
are those that emit, or have the potential to emit, any single HAP at a
rate of 10 tons per year (tpy) or more, or 25 tpy or more of any
combination of HAP. For major sources, these standards are commonly
referred to as maximum achievable control technology (MACT) standards
and must reflect the maximum degree of emission reductions of HAP
achievable (after considering cost, energy requirements, and non-air
quality health and environmental impacts). In developing MACT
standards, CAA section 112(d)(2) directs the EPA to consider the
application of measures, processes, methods, systems, or techniques,
including, but not limited to, those that reduce the volume of or
eliminate HAP emissions through process changes, substitution of
materials, or other modifications; enclose systems or processes to
eliminate emissions; collect, capture, or treat HAP when released from
a process, stack, storage, or fugitive emissions point; are design,
equipment, work practice, or operational standards; or any combination
of the above.
For these MACT standards, the statute specifies certain minimum
stringency requirements, which are referred to as MACT floor
requirements, and which may not be based on cost considerations. See
CAA section 112(d)(3). For new sources, the MACT floor cannot be less
stringent than the emission control achieved in practice by the best-
controlled similar source. The MACT floor for existing sources can be
less stringent than floors for new sources, but they cannot be less
stringent than the average emission limitation achieved by the best-
performing 12 percent of existing sources in the category or
subcategory (or the best-performing five sources for categories or
subcategories with fewer than 30 sources). In developing MACT
standards, we must also consider control options that are more
stringent than the floor under CAA section 112(d)(2). We may establish
standards more stringent than the floor, based on the consideration of
the cost of achieving the emissions reductions, any non-air quality
health and environmental impacts, and energy requirements.
In the second stage of the regulatory process, the CAA requires the
EPA to undertake two different analyses, which we refer to as the
technology review and the residual risk review. Under the technology
review, we must review the technology-based standards and revise them
``as necessary (taking into account developments in practices,
processes, and control technologies)'' no less frequently than every 8
years, pursuant to CAA section 112(d)(6). Under the residual risk
review, we must evaluate the risk to public health remaining after
application of the technology-based standards and revise the standards,
if necessary, to provide an ample margin of safety to protect public
health or to prevent, taking into consideration costs, energy, safety,
and other relevant factors, an adverse environmental effect. The
residual risk review is required within 8 years after promulgation of
the technology-based standards, pursuant to CAA section 112(f). In
conducting the residual risk review, if the EPA determines that the
current standards provide an ample margin of safety to protect public
health, it is not necessary to revise the MACT standards pursuant to
CAA section 112(f).\1\ For more information on the statutory authority
for this rule, see the proposal preamble (84 FR 25908, June 4, 2019)
and the memorandum, CAA Section 112 Risk and Technology Reviews:
Statutory Authority and Methodology, December 14, 2017, in the Surface
Coating of Metal Cans Docket and the Surface Coating of Metal Coil
Docket.
---------------------------------------------------------------------------
\1\ The Court has affirmed this approach of implementing CAA
section 112(f)(2)(A): NRDC v. EPA, 529 F.3d 1077, 1083 (D.C. Cir.
2008) (``If EPA determines that the existing technology-based
standards provide an `ample margin of safety,' then the Agency is
free to readopt those standards during the residual risk
rulemaking.'').
---------------------------------------------------------------------------
B. What are the source categories and how do the NESHAP regulate HAP
emissions from the source categories?
1. What is the Surface Coating of Metal Cans source category and how
does the current NESHAP regulate its HAP emissions?
The EPA promulgated the Surface Coating of Metal Cans NESHAP on
November 13, 2003 (68 FR 64432). The standards are codified at 40 CFR
part 63, subpart KKKK. The Surface Coating of Metal Cans industry
consists of facilities that are engaged in the surface coating of metal
cans and ends (including decorative tins) and metal crowns and
[[Page 10831]]
closures. The source category covered by this MACT standard currently
includes five facilities.
The Surface Coating of Metal Cans NESHAP (40 CFR 63.3561) defines a
``metal can'' as ``a single-walled container manufactured from metal
substrate equal to or thinner than 0.3785 millimeter (mm) (0.0149
inch)'' and includes coating operations for four subcategories: (1)
One- and two- piece draw and iron can body coating; (2) sheetcoating;
(3) three-piece can body assembly coating; and (4) end coating. The
Surface Coating of Metal Cans NESHAP also defines a ``coating'' as ``a
material that is applied to a substrate for decorative, protective, or
functional purposes. Such materials include, but are not limited to,
paints, sealants, caulks, inks, adhesives, and maskants.'' This source
category is further described in the June 4, 2019, RTR proposal. See 84
FR 25908.
The primary HAP emitted from this source category are organic HAP
and include glycol ethers, formaldehyde, xylenes, toluene, methyl
isobutyl ketone, 2-(hexyloxy) ethanol, ethyl benzene, and methanol.
These HAP account for 99 percent of the HAP emissions from the source
category. The HAP emissions from the Surface Coating of Metal Cans
source category are emitted from the coating materials which include
the coatings, thinners, and cleaning materials used in the coating
operations. The coating operations include: The equipment used to apply
the coatings; the equipment to dry or cure the coatings after
application; all storage containers and mixing vessels; all manual and
automated equipment and containers used to convey the coating
materials; and all storage containers and manual and automated
equipment used for conveying waste materials generated by the coating
operations. The coating application lines and the drying and curing
ovens are the largest sources of HAP emissions. The coating application
lines apply an exterior base coat to two- and three-piece cans using a
lithographic/printing (i.e., roll) application process. The inside,
side seam, and repair coatings are spray applied using airless spray
equipment and are a minor portion of the can coating operations. As
indicated by the name, repair spray coatings are used to cover breaks
in the coating that are caused during the formation of the score in
easy-open ends or to provide, after the manufacturing process, an
additional protective layer for corrosion resistance.
The Surface Coating of Metal Cans NESHAP specifies numerical
emission limits for existing sources and for new or reconstructed
sources for organic HAP emissions from four subcategories of can
coating operations. Within the four subcategories are several different
types of coatings with separate emission limits. The specific organic
HAP emission limits are provided in Tables 1 and 2 of 40 CRF part 63,
subpart KKKK.
The Surface Coating of Metal Cans NESHAP provides that emission
limits can be achieved using several different options, including a
compliant material option, an emission rate without add-on controls
option (averaging option), an emission rate with add-on controls
option, or a control efficiency/outlet concentration option. For any
coating operation(s) on which the facility uses the compliant material
option or the emission rate without add-on controls option, the
facility is not required to meet any work practice standards.
If the facility uses the emission rate with add-on controls option,
the facility must develop and implement a work practice plan to
minimize organic HAP emissions from the storage, mixing, and conveying
of coatings, thinners, and cleaning materials used in, and waste
materials generated by, the coating operation(s) using that option. The
plan must specify practices and procedures to ensure that a set of
minimum work practices specified in the NESHAP are implemented. The
facility must also comply with site-specific operating limits for the
emission capture and control system.
2. What is the Surface Coating of Metal Coil source category and how
does the current NESHAP regulate its HAP emissions?
The EPA promulgated the Surface Coating of Metal Coil source
category NESHAP on June 10, 2002 (67 FR 39794). The standards are
codified at 40 CFR part 63, subpart SSSS. The Surface Coating of Metal
Coil industry consists of facilities that operate a metal coil coating
line. The source category covered by this MACT standard currently
includes 48 facilities.
The Surface Coating of Metal Coil NESHAP (40 CFR 63.5110) defines a
``coil coating line'' as ``a process and the collection of equipment
used to apply an organic coating to the surface of metal coil.'' A coil
coating line includes a web unwind or feed section, a series of one or
more work stations, and any associated curing oven, wet section, and
quench station. A work station is ``a unit on a coil coating line where
the coating material is deposited onto the metal coil substrate'' or a
coating application station. This source category is further described
in the June 4, 2019, RTR proposal. See 84 FR 25909.
The primary HAP emitted from metal coil coating operations are
organic HAP and include xylenes, glycol ethers, naphthalene,
isophorone, toluene, diethylene glycol monobutyl ether (DGME), and
ethyl benzene. The majority of organic HAP emissions are from the
coating application stations and the curing ovens.
The Surface Coating of Metal Coil NESHAP specifies numerical
emission limits for organic HAP emissions from the coating application
stations and associated curing ovens. The Surface Coating of Metal Coil
NESHAP provides that emission limits can be achieved using several
different options: (1) Use only individually compliant coatings with an
organic HAP content that does not exceed 0.046 kilogram (kg)/liter of
solids applied, (2) use coatings with an average organic HAP content
that does not exceed 0.046 kg/liter of solids on a rolling 12-month
average, (3) use a capture system and add-on control device to either
reduce emissions by 98 percent or use a 100-percent efficient capture
system (permanent total enclosure (PTE)) and an oxidizer to reduce
organic HAP emissions to no more than 20 parts per million by volume as
carbon, or (4) use a combination of compliant coatings and control
devices to maintain an average equivalent emission rate of organic HAP
not exceeding 0.046 kg/liter of solids on a rolling 12-month average
basis. These compliance options apply to an individual coil coating
line, to multiple lines as a group, or to the entire affected source.
C. What changes did we propose for the source categories in our June 4,
2019, RTR proposal?
On June 4, 2019, the EPA published proposed rule amendments in the
Federal Register for the Surface Coating of Metal Cans NESHAP, 40 CFR
part 63, subpart KKKK, and the Surface Coating of Metal Coil NESHAP, 40
CFR part 63, subpart SSSS, that took into consideration the RTR
analyses.
For each source category, we proposed that the risks are
acceptable, and that additional emission controls for each source
category are not necessary to provide an ample margin of safety. For
the technology reviews, we did not identify any developments in
practices, processes, or control technologies, and, therefore, we did
not propose any changes to the standards under CAA section 112(d)(6).
We also proposed the following amendments:
[[Page 10832]]
For each source category, a requirement for electronic
submittal of notifications, semi-annual reports, and compliance reports
(which include performance test reports);
for each source category, revisions to the SSM provisions
of each NESHAP in order to ensure that they are consistent with the
Court decision in Sierra Club v. EPA, 551 F. 3d 1019 (D.C. Cir. 2008),
which vacated two provisions that exempted source owners and operators
from the requirement to comply with otherwise applicable CAA section
112(d) emission standards during periods of SSM;
for the Surface Coating of Metal Coil NESHAP, adding the
option of conducting EPA Method 18 of appendix A to 40 CFR part 60,
``Measurement of Gaseous Organic Compound Emissions by Gas
Chromatography,'' to measure and then subtract methane emissions from
measured total gaseous organic mass emissions as carbon;
for the Surface Coating of Metal Coil NESHAP, revising 40
CFR 63.5090 to clarify that the NESHAP does not apply to the
application of markings (including letters, numbers, or symbols) to
bare metal coils that are used for product identification or for
product inventory control;
for each source category, removing references to paragraph
(d)(4) of the Occupational Safety and Health Administration's (OSHA's)
Hazard Communication standard (29 CFR 1910.1200), which dealt with
OSHA-defined carcinogens, and replacing that reference with a list of
HAP that must be regarded as potentially carcinogenic based on EPA
guidelines;
for each source category, a requirement to conduct
performance testing and reestablish operating limits no less frequently
than every 5 years for sources that are using add-on controls to
demonstrate compliance; and
for each source category, Incorporation by Reference (IBR)
of alternative test methods and references to updated alternative test
methods; and several minor editorial and technical changes in each
subpart.
III. What is included in these final rules?
This action finalizes the EPA's determinations pursuant to the RTR
provisions of CAA section 112 for the Surface Coating of Metal Cans
source category and the Surface Coating of Metal Coil source category.
This action also finalizes other changes to the NESHAP for each source
category, including:
A requirement for electronic submittal of notifications,
semi-annual reports, and compliance reports (which include performance
test reports);
revisions to the SSM provisions;
removing references to paragraph (d)(4) of OSHA's Hazard
Communication standard (29 CFR 1910.1200), which dealt with OSHA-
defined carcinogens, and replacing that reference with a list of HAP
that must be regarded as potentially carcinogenic based on EPA
guidelines;
adding a requirement to conduct performance testing and
reestablish operating limits no less frequently than every 5 years for
sources that are using add-on controls to demonstrate compliance,
unless they are already required to perform comparable periodic testing
as a condition of renewing their title V operating permit;
IBR of alternative test methods and references to updated
alternative test methods; and
several minor editorial and technical changes.
This action also finalizes the proposed changes to the NESHAP for the
Surface Coating of Metal Coil source category by adding the option of
conducting EPA Method 18 of appendix A to 40 CFR part 60, ``Measurement
of Gaseous Organic Compound Emissions by Gas Chromatography,'' to
measure and then subtract methane emissions from measured total gaseous
organic mass emissions as carbon; and by revising 40 CFR 63.5090 to
clarify that the NESHAP does not apply to the application of markings
(including letters, numbers, or symbols) to bare metal coils that are
used for product identification or for product inventory control.
A. What are the final rule amendments based on the risk reviews for the
Surface Coating of Metal Cans and Surface Coating of Metal Coil source
categories?
This section describes the final amendments to the Surface Coating
of Metal Cans NESHAP (subpart KKKK) and the Surface Coating of Metal
Coil NESHAP (subpart SSSS) being promulgated pursuant to CAA section
112(f). In this action, we are finalizing our proposed determinations
that risks from these two subparts are acceptable, and that the
standards provide an ample margin of safety to protect public health
and to prevent an adverse environmental effect. The EPA proposed no
changes to these two subparts based on the risk reviews conducted
pursuant to CAA section 112(f). The EPA received no new data or other
information during the public comment period that causes us to change
those proposed determinations. Therefore, we are not requiring
additional controls under CAA section 112(f)(2) for either of the two
subparts in this action.
B. What are the final rule amendments based on the technology reviews
for the Surface Coating of Metal Cans and the Surface Coating of Metal
Coil source categories?
We determined that there are no developments in practices,
processes, and control technologies that warrant revisions to the MACT
standards for these source categories. Therefore, we are not finalizing
revisions to the MACT standards under CAA section 112(d)(6).
C. What are the final rule amendments addressing emissions during
periods of startup, shutdown, and malfunction?
We are finalizing the proposed amendments to the Surface Coating of
Metal Cans NESHAP and the Surface Coating of Metal Coil NESHAP to
eliminate the SSM exemption. Consistent with Sierra Club v. EPA, 551 F.
3d 1019 (D.C. Cir. 2008), the EPA is establishing standards in these
rules that apply at all times. As detailed in section IV.C of the
proposal preamble (84 FR 25904, June 4, 2019), Table 5 to Subpart KKKK
of Part 63 and Table 2 to Subpart SSSS of Part 63 (General Provisions
applicability tables) are being revised to change several references
related to the provisions that apply during periods of SSM. We also
eliminated or revised certain recordkeeping and reporting requirements
related to the eliminated SSM exemption. The EPA also made other
harmonizing changes to remove or modify inappropriate, unnecessary, or
redundant language in the absence of the SSM exemption. We determined
that facilities in both of these source categories can meet the
applicable emission standards in the Surface Coating of Metal Cans
NESHAP and the Surface Coating of Metal Coil NESHAP at all times,
including periods of startup and shutdown. Therefore, the EPA
determined that no additional standards are needed to address emissions
during these periods. The legal rationale and explanation of the
changes for SSM periods are set forth in the proposed rule. See 84 FR
25925 through 25929 and 25936 through 25939.
Further, the EPA is not finalizing standards for malfunctions. As
discussed in section IV.C of the June 4, 2019, proposal preamble, the
EPA interprets CAA section 112 as not requiring emissions that occur
during periods of malfunction to be factored into development of CAA
section 112 standards, although the EPA has the discretion to set
standards for malfunctions where feasible. For these
[[Page 10833]]
source categories, it is unlikely that a malfunction would result in a
violation of the standards, and no comments or information were
submitted that support a contrary conclusion. Refer to section IV.C of
the June 4, 2019 proposal preamble for further discussion of the EPA's
rationale for the decision not to set standards for malfunctions, as
well as a discussion of the actions a source could take in the unlikely
event that a source fails to comply with the applicable CAA section
112(d) standards as a result of a malfunction event, given that
administrative and judicial procedures for addressing exceedances of
the standards fully recognize that violations may occur despite good
faith efforts to comply and the EPA can consider all relevant
information when determining the appropriate response to those
situations.
We are finalizing a revision to the performance testing
requirements at 40 CFR 63.4164 and 40 CFR 63.5160. The final
performance testing provisions prohibit performance testing during
startup, shutdown, or malfunction as these conditions are not
representative of steady state operating conditions. The final rules
also require that operators maintain records to document that operating
conditions during performance tests represent steady state conditions.
D. What other changes have been made to the NESHAPs?
For both the Surface Coating of Metal Cans NESHAP and the Surface
Coating of Metal Coil NESHAP, the EPA is finalizing, as proposed,
several other revisions that are described in the following paragraphs.
To increase the ease and efficiency of data submittal and data
accessibility, we are finalizing a requirement that owners and
operators of facilities in the Surface Coating of Metal Cans and
Surface Coating of Metal Coil source categories submit electronic
copies of required performance test reports through the EPA's Central
Data Exchange (CDX) website using an electronic performance test report
tool called the Electronic Reporting Tool (ERT). We also are
finalizing, as proposed, provisions that allow facility operators the
ability to seek extensions for submitting electronic reports for
circumstances beyond the control of the facility, i.e., for a possible
outage in the CDX or Compliance and Emissions Data Reporting Interface
(CEDRI) or for a force majeure event in the time just prior to a
report's due date, as well as the process to assert such a claim.
For each subpart, we also are changing the format of references to
test methods in 40 CFR part 60, appendix A to indicate where, in the
eight sections of appendix A, each method is found.
For each subpart, we are finalizing the proposal to re-designate
the list of applicable organic HAP that must be used when a facility
chooses to use the compliant material option (i.e., for calculating
total organic HAP content of a coating material present at 0.1 percent
or greater by mass). To specify the applicable HAP, we are changing the
rule to remove the reference to paragraph (d)(4) of OSHA's Hazard
Communication standard (29 CFR 1910.1200) and replace it with a new
table in each subpart (Table 8 in 40 CFR part 63, subpart KKKK and
Table 3 in 40 CFR part 63, subpart SSSS) that lists the applicable HAP.
The organic HAP in these new tables are those HAP that were categorized
in the EPA's ``Prioritized Chronic Dose-Response Values for Screening
Risk Assessments'' (dated May 9, 2014) as a ``human carcinogen,''
``probable human carcinogen,'' or ``possible human carcinogen''
according to The Risk Assessment Guidelines of 1986 (EPA/600/8-87/045,
August 1987) \2\ or as ``carcinogenic to humans,'' ``likely to be
carcinogenic to humans,'' or with ``suggestive evidence of carcinogenic
potential'' according to the Guidelines for Carcinogen Risk Assessment
(EPA/630/P-03/001F, March 2005).
---------------------------------------------------------------------------
\2\ See https://www.epa.gov/fera/dose-response-assessment-assessing-health-risks-associated-exposure-hazardous-air-pollutants.
---------------------------------------------------------------------------
We are including in the final rule for each subpart a requirement
for facilities that use control devices to conduct control device
performance testing no less frequently than once every 5 years. For
facilities with title V permits that require comparable periodic
testing prior to permit renewal, no additional testing is required, and
we included provisions in the rule to allow sources to harmonize the
NESHAP testing schedule with a facility's current title V testing
schedule.
1. Technical Amendments to the Surface Coating of Metal Cans NESHAP
In the final rule, we are amending 40 CFR 63.3481(c)(5), as
proposed, to revise the reference to ``future subpart MMMM'' of this
part by removing the word ``future'' because subpart MMMM was
promulgated in 2004.
We are revising the monitoring provisions for thermal and catalytic
oxidizers, as proposed, to clarify that a thermocouple is part of the
temperature sensor referred to in 40 CFR 63.3547(c)(3) and 40 CFR
63.3557(c)(3) for purposes of performing periodic calibration and
verification checks.
Currently, 40 CFR 63.3513(a) allows records, ``where appropriate,''
to be maintained as ``electronic spreadsheets'' or a ``database.'' As
proposed, we are adding a clarification to this provision that the
allowance to retain electronic records applies to all records that were
submitted as reports electronically via the EPA's CEDRI. We are also
adding text to the same provision, as proposed, clarifying that this
ability to maintain electronic copies does not affect the requirement
for facilities to make records, data, and reports available upon
request to a delegated air agency or the EPA as part of an on-site
compliance evaluation.
In the final rule, as proposed, we are adding and updating test
methods that are incorporated by reference. In accordance with
requirements of 1 CFR 51.5, the EPA is incorporating by reference the
following voluntary consensus standards (VCS) described in the
amendments to 40 CFR 63.14:
ASTM D1475-13, Standard Test Method for Density of Liquid
Coatings, Inks, and Related Products, proposed to be IBR approved for
40 CFR 63.3521(c) and 63.3531(c);
ASTM D2111-10 (2015), Standard Test Methods for Specific
Gravity and Density of Halogenated Organic Solvents and Their
Admixtures, proposed to be IBR approved for 40 CFR 63.3521(c) and
63.3531(c);
ASTM D2369-10 (2015), Test Method for Volatile Content of
Coatings, proposed to be IBR approved for 40 CFR 63.3521(a)(2) and
63.3541(i)(3);
ASTM D2697-03 (2014), Standard Test Method for Volume
Nonvolatile Matter in Clear or Pigmented Coatings, proposed to be IBR
approved for 40 CFR 63.3521(b)(1); and
ASTM D6093-97 (2016), Standard Test Method for Percent
Volume Nonvolatile Matter in Clear or Pigmented Coatings Using Helium
Gas Pycnometer, proposed to be IBR approved for 40 CFR 63.3521(b)(1).
2. Technical Amendments to the Surface Coating of Metal Coil NESHAP
We are finalizing, as proposed, changes to 40 CFR 63.5090 to
clarify that 40 CFR part 63, subpart SSSS does not apply to the
application to bare metal coils of markings (including letters,
numbers, or symbols) that are used for product identification or for
product inventory control.
We are finalizing amendments to 40 CFR 63.5160(d) in 40 CFR part
63, subpart SSSS, as proposed, to add the option of conducting EPA
Method 18 of appendix A to 40 CFR part 60,
[[Page 10834]]
``Measurement of Gaseous Organic Compound Emissions by Gas
Chromatography,'' to measure and then subtract methane emissions from
measured total gaseous organic mass emissions, as carbon, for those
facilities using the emission rate with add-on control compliance
option and EPA Method 25A to measure control device destruction
efficiency.
Currently 40 CFR 63.5190 specifies records that must be maintained.
We are adding, as proposed, clarification to 40 CFR 63.5190(c) that
specifies the allowance to retain electronic records applies to all
records that were submitted as reports electronically via the EPA's
CEDRI. We are also adding text to the same provision clarifying that
this ability to maintain electronic copies does not affect the
requirement for facilities to make records, data, and reports available
upon request to a delegated air agency or the EPA as part of an on-site
compliance evaluation.
We are clarifying and harmonizing, as proposed, the general duty
requirement in 40 CFR 63.5140(a) with the reporting requirements in 40
CFR 63.5180(g)(2)(v) and 40 CFR 63.5180(h)(4) and the recordkeeping
requirement in 40 CFR 63.5190(a)(5), by including new language in 40
CFR 63.5140(a) to read as, ``. . . you must be in compliance with the
applicable emission standards in Sec. 63.5120 and the operating limits
in Table 1 of this subpart at all times.''
We are revising, as proposed, the text in the semi-annual reporting
provisions of 40 CFR 63.5180(g)(2)(v) to read, ``A statement that there
were no deviations from the applicable emission limit in Sec. 63.5120
or the applicable operating limit(s) established according to Sec.
63.5121 during the reporting period, and that no continuous emissions
monitoring systems (CEMS) were inoperative, inactive, malfunctioning,
out-of-control, repaired, or adjusted.'' Conforming changes are also
being made to the reporting requirement at 40 CFR 63.5180(h)(4) and the
recordkeeping requirement at 40 CFR 63.5190(a)(5).
We are revising, as proposed, one instance in 40 CFR 63.5160(e) in
which an erroneous rule citation, ``Sec. 63.5170(h)(2) through (4),''
is made by correcting the citation to ``Sec. 63.5170(g)(2) through
(4).''
We are amending, as proposed, 40 CFR 63.5130(a) to clarify that the
compliance date for existing affected sources is June 10, 2005.
We are amending, as proposed, 40 CFR 63.5160(d)(3)(ii)(D) to
correct a typographical error in a reference to paragraphs
``(d)(3)(ii)(D)(1 (3).'' The correct reference is to paragraphs
(d)(3)(ii)(D)(1)-(3).
We are amending, as proposed, 40 CFR 63.5170(c)(1) and (2) to
correct the cross references to 40 CFR 63.5120(a)(1) or (2). The
correct cross references are to 40 CFR 63.5120(a)(1) or (3).
We are amending, as proposed, Equation 11 in 40 CFR 63.5170 so that
the value calculated by the equation is correctly identified as
``He'' instead of just ``e.''
In the final rule, as proposed, we are adding and updating test
methods that are incorporated by reference. In accordance with
requirements of 1 CFR 51.5, the EPA is incorporating by reference the
following methods and VCS described in the amendments to 40 CFR 63.14:
ASTM D1475-13, Standard Test Method for Density of Liquid
Coatings, Inks, and Related Products, proposed to be IBR approved for
40 CFR 63.5160(c);
ASTM D2111-10 (2015), Standard Test Methods for Specific
Gravity and Density of Halogenated Organic Solvents and Their
Admixtures, proposed to be IBR approved for 40 CFR 63.5160(c);
ASTM D2369-10 (2015), Test Method for Volatile Content of
Coatings, proposed to be IBR approved for 40 CFR 63.5160(b)(2);
ASTM D2697-03 (2014), Standard Test Method for Volume
Nonvolatile Matter in Clear or Pigmented Coatings, proposed to be IBR
approved for 40 CFR 63.5160(c); and
ASTM D6093-97 (2016), Standard Test Method for Percent
Volume Nonvolatile Matter in Clear or Pigmented Coatings Using Helium
Gas Pycnometer, proposed to be IBR approved for 40 CFR 63.5160(c).
E. What are the effective and compliance dates of the revisions to the
standards?
The revisions to the MACT standards being promulgated in this
action are effective on February 25, 2020.
The compliance date for existing affected sources in both the
Surface Coating of Metal Cans and Surface Coating of Metal Coil source
categories is August 24, 2020, with the exception of the electronic
format for submitting semiannual compliance reports. New sources must
comply with all of the standards immediately upon the effective date of
the standard, February 25, 2020, or upon startup, whichever is later,
with the exception of the electronic format for submitting semiannual
compliance reports. For the electronic format for submitting semiannual
compliance reports, both existing and new affected sources will have 1
year after the electronic reporting templates are available on CEDRI,
or 1 year after February 25, 2020, whichever is later. The EPA selected
these compliance dates based on experience with similar industries and
the EPA's detailed justification for the selected compliance dates is
included in the preamble to the proposed rule (84 FR 25931 and 25942).
F. What are the requirements for submission of performance test data to
the EPA?
As proposed, the EPA is taking a step to increase the ease and
efficiency of data submittal and data accessibility. Specifically, the
EPA is finalizing the requirement for owners and operators of
facilities in the Surface Coating of Metal Cans and Surface Coating of
Metal Coil source categories to submit electronic copies of certain
required performance test reports.
Data will be collected by direct computer-to-computer electronic
transfer using EPA-provided software. This EPA-provided software is an
electronic performance test report tool called the ERT. The ERT will
generate an electronic report package which will be submitted to CEDRI
and then archived to the EPA's CDX. A description of the ERT and
instructions for using ERT can be found at https://www3.epa.gov/ttn/chief/ert/. The CEDRI interface can be accessed through the
CDX website (https://cdx.epa.gov/).
The requirement to submit performance test data electronically to
the EPA does not create any additional performance testing requirements
and will apply only to those performance tests conducted using test
methods that are supported by the ERT. A listing of the pollutants and
test methods supported by the ERT is available at the ERT website.
Through this approach, industry will save time in the performance test
submittal process. Additionally, this rulemaking will benefit industry
by reducing recordkeeping costs, as the performance test reports that
are submitted to the EPA using CEDRI are no longer required to be kept
in hard copy.
State, local, and tribal agencies may benefit from a more
streamlined and accurate review of performance test data that will
become available to the public through WebFIRE. Having such data
publicly available enhances transparency and accountability. For a more
thorough discussion of electronic reporting of performance tests using
direct computer-to-computer electronic transfer and using EPA-provided
software, see the discussion in the
[[Page 10835]]
preamble of the proposed rules (84 FR 25904, June 24, 2019) and the
memorandum, Electronic Reporting Requirements for New Source
Performance Standards (NSPS) and National Emission Standards for
Hazardous Air Pollutants (NESHAP) Rules, August 8, 2018, in the Surface
Coating of Metal Cans and Surface Coating of Metal Coil Dockets.
In summary, in addition to supporting regulation development,
control strategy development, and other air pollution control
activities, having an electronic database populated with performance
test data will save industry, state/local/tribal agencies, and the EPA
significant time, money, and effort while improving the quality of
emission inventories and air quality regulations.
IV. What is the rationale for our final decisions and amendments for
the Surface Coating of Metal Cans and Surface Coating of Metal Coil
source categories?
For each issue, this section provides a description of what we
proposed and what we are finalizing for the issue, the EPA's rationale
for the final decisions and amendments, and a summary of key comments
and responses. For all comments not discussed in this preamble, comment
summaries and the EPA's responses can be found in the comment summary
and response document available in the Surface Coating of Metal Cans
and Surface Coating of Metal Coil Dockets.
A. Residual Risk Reviews
1. What did we propose pursuant to CAA section 112(f)?
a. Surface Coating of Metal Cans (40 CFR Part 63, subpart KKKK) Source
Category
Pursuant to CAA section 112(f), the EPA conducted a residual risk
review and presented the results of this review, along with our
proposed decisions regarding risk acceptability and ample margin of
safety, in sections IV.A.2.a and b of the proposed rule preamble (84 FR
25904, June 24, 2019). The results of this review are presented briefly
below in Table 2 of this preamble. Additional detail is provided in the
residual risk technical support document titled, Residual Risk
Assessment for the Surface Coating of Metal Cans Source Category in
Support of the 2019 Risk and Technology Review Proposed Rule, which is
available in the Surface Coating of Metal Cans Docket.
Table 2--Surface Coating of Metal Cans Source Category Inhalation Risk Assessment Results at Proposal
--------------------------------------------------------------------------------------------------------------------------------------------------------
Maximum individual Estimated population Estimated annual Maximum chronic
cancer risk (in 1 at increased risk of cancer incidence noncancer TOSHI \1\
million) cancer >=1-in-1 (cases per year) ------------------------
------------------------ million ------------------------ Maximum screening acute
Risk assessment ------------------------ Based on Based on noncancer HQ \2\
Based on Based on Based on Based on Based on Based on actual allowable
actual allowable actual allowable actual allowable emissions emissions
emissions emissions emissions emissions emissions emissions
--------------------------------------------------------------------------------------------------------------------------------------------------------
Source Category............... 3 3 700 800 0.0009 0.001 0.02 0.02 HQREL = 0.4.
Whole Facility................ 8 .......... 1,500 .......... 0.002 .......... 0.2 .......... ........................
--------------------------------------------------------------------------------------------------------------------------------------------------------
\1\ The target organ-specific hazard index (TOSHI) is the sum of the chronic noncancer hazard quotients (HQ) values for substances that affect the same
target organ or organ system.
\2\ The maximum estimated acute exposure concentration was divided by available short-term threshold values to develop HQ values (HQREL = hazard
quotient reference exposure level).
The results of the proposal inhalation risk modeling using actual
emissions data, as shown in Table 2 of this preamble, indicate that the
maximum individual cancer risk based on actual emissions (lifetime) is
3-in-1 million (driven by formaldehyde), the maximum chronic noncancer
TOSHI value based on actual emissions is 0.02 (driven by formaldehyde),
and the maximum screening acute noncancer HQ value (off-facility site)
could be up to 0.4 (driven by formaldehyde). At proposal, the total
annual cancer incidence (national) from these facilities based on
actual emission levels was estimated to be 0.0009 excess cancer cases
per year, or one case in every 1,100 years.
The results of the proposal inhalation risk modeling using
allowable emissions data, as shown in Table 2 of this preamble,
indicate that the maximum individual cancer risk based on allowable
emissions (lifetime) is 3-in-1 million (driven by formaldehyde), and
the maximum chronic noncancer TOSHI value based on allowable emissions
is 0.02 (driven by formaldehyde). At proposal, the total annual cancer
incidence (national) from these facilities based on allowable emissions
was estimated to be 0.001 excess cancer cases per year, or one case in
every 1,000 years.
The maximum individual cancer risk (lifetime) for the whole
facility was determined to be 8-in-1 million at proposal, driven by
formaldehyde from miscellaneous industrial processes (other/not
classified) and acetaldehyde from beer production (brew kettle). At
proposal, the total estimated cancer incidence from the whole facility
was determined to be 0.002 excess cancer cases per year, or one excess
case in every 500 years. Approximately 1,500 people were estimated to
have cancer risks above 1-in-1 million from exposure to HAP emitted
from both MACT and non-MACT sources at three of the five facilities in
this source category. The maximum facility-wide TOSHI for the source
category was estimated to be 0.2, mainly driven by emissions of
acetaldehyde from beer production (brew kettle) and formaldehyde from
miscellaneous industrial processes (other/not classified).
There are no persistent and bioaccumulative HAP (PB HAP) emitted by
facilities in this source category; therefore, we did not estimate any
human health multi-pathway risks from this source category. Two
environmental HAP are emitted by sources within this source category:
Hydrochloric acid (HCl) and hydrogen fluoride (HF). Therefore, at
proposal, we conducted a screening-level evaluation of the potential
adverse environmental risks associated with emissions of HCl and HF.
Based on this evaluation, we proposed that we do not expect an adverse
environmental effect as a result of HAP emissions from this source
category.
We weighed all health risk factors, including those shown in Table
2 of this preamble, in our risk acceptability determination and
proposed that the residual risks from the Surface Coating of Metal Cans
source category are acceptable (section IV.A.2.a of proposal preamble,
84 FR 25922, June 4, 2019).
We then considered whether 40 CFR part 63, subpart KKKK provides an
ample margin of safety to protect public health and prevents, taking
into consideration costs, energy, safety, and other relevant factors,
an adverse
[[Page 10836]]
environmental effect. In considering whether the standards should be
tightened to provide an ample margin of safety to protect public
health, we considered the same risk factors that we considered for our
acceptability determination and also considered the costs,
technological feasibility, and other relevant factors related to
emissions control options that might further reduce risk associated
with emissions from the source category. Related to risk, the baseline
risks were low, and regardless of the availability of further control
options, little risk reduction could be realized. As discussed further
in section IV.B of this preamble, the only development identified in
the technology review was the ongoing development and the potential
future conversion from conventional interior can coatings that contain
bisphenol A (BPA) to interior coatings that do not intentionally
contain BPA (BPA-NI). Since BPA and BPA-NI are not HAP, this change
would have no effect on the HAP emissions. There were no other
technological developments identified that affect HAP emissions for the
Surface Coating of Metal Cans source category. Therefore, given the low
baseline risks and lack of options for further risk reductions, we
proposed that additional emission controls for this source category are
not necessary to provide an ample margin of safety (section IV.A.2.b of
proposal preamble, 84 FR 25922, June 4, 2019).
b. Surface Coating of Metal Coil (40 CFR Part 63, Subpart KKKK) Source
Category
Pursuant to CAA section 112(f), the EPA conducted a residual risk
review and presented the results of this review, along with our
proposed decisions regarding risk acceptability and ample margin of
safety, in sections IV.B.2.a and b of the proposed rule preamble (84 FR
25904, June 24, 2019). The results of this review are presented briefly
below in Table 3 of this preamble. Additional detail is provided in the
residual risk technical support document titled, Residual Risk
Assessment for the Surface Coating of Metal Coil Source Category in
Support of the 2019 Risk and Technology Review Proposed Rule, which is
available in the Surface Coating of Metal Coil Docket.
Table 3--Surface Coating of Metal Coil Source Category Inhalation Risk Assessment Results at Proposal
--------------------------------------------------------------------------------------------------------------------------------------------------------
Maximum individual Estimated population Estimated annual Maximum chronic
cancer risk (in 1 at increased risk of cancer incidence noncancer TOSHI \1\
million) cancer >= 1-in-1 (cases per year) ------------------------
------------------------ million ------------------------ Maximum screening
Risk assessment ------------------------ Based on Based on acute noncancer HQ \2\
Based on Based on Based on Based on Based on Based on actual allowable
actual allowable actual allowable actual allowable emissions emissions
emissions emissions emissions emissions emissions emissions
--------------------------------------------------------------------------------------------------------------------------------------------------------
Source Category................. 10 10 19,000 24,000 0.005 0.006 0.1 0.1 HQREL = 3.
Whole Facility.................. 40 .......... 270,000 .......... 0.03 .......... 5 .......... ......................
--------------------------------------------------------------------------------------------------------------------------------------------------------
\1\ The TOSHI is the sum of the chronic noncancer HQ values for substances that affect the same target organ or organ system.
\2\ The maximum estimated acute exposure concentration was divided by available short-term threshold values to develop HQ values (HQREL = hazard
quotient reference exposure level).
The results of the proposal inhalation risk modeling using actual
emissions data, as shown in Table 3 of this preamble, indicate that the
maximum individual cancer risk based on actual emissions (lifetime) is
10-in-1 million (driven by naphthalene from solvent storage), the
maximum chronic noncancer TOSHI value based on actual emissions is 0.1
(driven by glycol ethers from prime and finish coating application),
and the maximum screening acute noncancer HQ value (off-facility site)
could be up to 3 (driven by DGME). At proposal, the total annual cancer
incidence (national) from these facilities based on actual emission
levels was estimated to be 0.005 excess cancer cases per year, or one
case in every 200 years.
The results of the proposal inhalation risk modeling using
allowable emissions data, as shown in Table 3 of this preamble,
indicate that the maximum individual cancer risk based on allowable
emissions (lifetime) is 10-in-1 million (driven by naphthalene from
solvent storage), and the maximum chronic noncancer TOSHI value based
on allowable emissions is 0.1 (driven by glycol ethers from prime and
finish coating application). At proposal, the total annual cancer
incidence (national) from these facilities based on allowable emissions
was estimated to be 0.006 excess cancer cases per year, or one case in
every 167 years.
The maximum individual cancer risk (lifetime) for the whole
facility was determined to be 40-in-1 million at proposal, driven by
naphthalene from equipment cleanup of metal coil coating processes. At
proposal, the total estimated cancer incidence from the whole facility
was determined to be 0.03 excess cancer cases per year, or one excess
case in every 30 years. Approximately 270,000 people were estimated to
have cancer risks above 1-in-1 million from exposure to HAP emitted
from both MACT and non-MACT sources of the 48 facilities in this source
category. The maximum facility-wide TOSHI for the source category was
estimated to be 5, driven by emissions of chlorine from a secondary
aluminum fluxing process.
One PB HAP is emitted by facilities in the source category: lead.
In evaluating the potential for multipathway effects from emissions of
lead, the modeled maximum annual lead concentration of 0.0004
micrograms per cubic meter ([micro]g/m\3\) was compared to the National
Ambient Air Quality Standards (NAAQS) for lead of 0.15 microgram per
cubic meter ([micro]g/m\3\). Results of this analysis confirmed that
the NAAQS for lead would not be exceeded by any facility. Based on this
evaluation, we proposed that there is no significant potential for
human health multi-pathway risks as a result of HAP emissions from this
source category. Two environmental HAP are emitted by sources within
this source category: HF and lead. Therefore, at proposal we conducted
a screening-level evaluation of the potential adverse environmental
risks associated with emissions of HF and lead. Based on this
evaluation, we proposed that we do not expect an adverse environmental
effect as a result of HAP emissions from this source category.
We weighed all health risk factors, including those shown in Table
3 of this preamble, in our risk acceptability determination and
proposed that the residual risks from the Surface Coating of Metal Coil
source category are acceptable (section IV.B.2.a of proposal preamble,
84 FR 25933 June 4, 2019).
We then considered whether 40 CFR part 63, subpart SSSS provides an
ample margin of safety to protect public
[[Page 10837]]
health and prevents, taking into consideration costs, energy, safety,
and other relevant factors, an adverse environmental effect. In
considering whether the standards should be tightened to provide an
ample margin of safety to protect public health, we considered the same
risk factors that we considered for our acceptability determination and
also considered the costs, technological feasibility, and other
relevant factors related to emissions control options that might
further reduce risk associated with emissions from the source category.
As discussed further in section IV.B of this preamble, based on our
technology review, we did not identify any developments in practices,
processes, or control technologies, and, therefore, we did not propose
any changes to the standards under CAA section 112(d)(6).
Due to the low baseline risks for the Surface Coating of Metal Coil
source category and lack of options for further risk reductions, we
proposed that additional emission controls for this source category are
not necessary to provide an ample margin of safety (section IV.B.2.b of
proposal preamble, 84 FR 25934, June 4, 2019).
2. How did the risk reviews change?
We have not changed any aspect of the risk assessment for either of
these two source categories as a result of public comments received on
the June 2019 proposal.
3. What key comments did we receive on the risk reviews, and what are
our responses?
We received comments in support of and against the proposed
residual risk reviews and our determinations that no revisions were
warranted under CAA section 112(f)(2) for either source category.
Generally, the comments that were not supportive of our determinations
based on the risk reviews suggested changes to the underlying risk
assessment methodology. For example, one commenter stated that the EPA
should lower the acceptability benchmark so that risks below 100-in-1
million are deemed unacceptable, include emissions outside of the
source categories in question in the risk assessment, and assume that
pollutants with noncancer health risks have no safe level of exposure.
After review of all the comments received, we determined that no
changes to our Science Advisory Board-approved residual risk review
process were necessary. The comments and our specific responses can be
found in the document, Summary of Public Comments and Responses for the
Risk and Technology Reviews for Surface Coating of Metal Cans and
Surface Coating of Metal Coil, available in the dockets for these
actions (Docket ID Nos. EPA-HQ-OAR-2017-0684 and EPA-HQ-OAR-2017-0685).
4. What is the rationale for our final approach and final decisions for
the risk reviews?
As noted in our proposal, the EPA sets standards under CAA section
112(f)(2) using ``a two-step standard-setting approach, with an
analytical first step to determine an `acceptable risk' that considers
all health information, including risk estimation uncertainty, and
includes a presumptive limit on the maximum individual risk (MIR) of
``approximately 1-in-10 thousand'' (see 54 FR 38045, September 14,
1989). We weigh all health risk factors in our risk acceptability
determination, including the cancer MIR, cancer incidence, the maximum
chronic noncancer TOSHI, the maximum acute noncancer HQ, the extent of
noncancer risks, the distribution of cancer and noncancer risks in the
exposed population, and the risk estimation uncertainties.
Since proposal, neither the risk assessment nor our determinations
regarding risk acceptability, ample margin of safety, or adverse
environmental effects have changed. For the reasons explained in the
proposed rule, we determined that the risks from the Surface Coating of
Metal Cans and the Surface Coating of Metal Coil source categories are
acceptable, and that the current standards provide an ample margin of
safety to protect public health and prevent an adverse environmental
effect. Therefore, we are not revising either subpart to require
additional controls pursuant to CAA section 112(f)(2) based on the
residual risk review, and we are readopting the existing standards
under CAA section 112(f)(2).
B. Technology Reviews
1. What did we propose pursuant to CAA section 112(d)(6)?
Based on our review, we did not identify any developments in
practices, processes, or control technologies for the Surface Coating
of Metal Cans source category, and, therefore, we did not propose any
changes to the standards under CAA section 112(d)(6). A brief summary
of the EPA's findings in conducting the technology review of metal can
coating operations was included in the preamble to the proposed rule
(84 FR 25922, June 4, 2019), and a detailed discussion of the EPA's
technology review and findings was included in the memorandum,
Technology Review for Surface Coating Operations in the Metal Can
Category, April 24, 2019, in the Surface Coating of Metal Cans Docket.
Based on our review, we did not identify any developments in
practices, processes, or control technologies for the Surface Coating
of Metal Coil source category, and, therefore, we did not propose any
changes to the standards under CAA section 112(d)(6). A brief summary
of the EPA's findings in conducting the technology review of coil
coating operations was included in the preamble to the proposed rule
(84 FR 25934, June 4, 2019), and a detailed discussion of the EPA's
technology review and findings was included in the memorandum,
Technology Review for Surface Coating Operations in the Metal Coil
Category, September 2017, in the Surface Coating of Metal Coil Docket.
2. How did the technology reviews change?
We are making no changes to the conclusions of the technology
reviews and are finalizing the results of the technology reviews for
the Surface Coating of Metal Cans and Surface Coating of Metal Coil
source categories as proposed.
3. What key comments did we receive on the technology reviews, and what
are our responses?
We received two general comments supporting the results of our
technology reviews for metal cans and metal coil surface coating and
one comment objecting to our conclusions that there have been no
technology developments in these two source categories.
Comment: One commenter alleged that the EPA has not met the legal
obligation under CAA section 112(d)(6) to review and revise emission
standards ``as necessary'' to account for ``developments in practices,
processes, and control technologies.'' The commenter objected that the
EPA proposed no revisions to the emission limits and claimed the EPA
provided no legally valid or rational explanation for its determination
of a lack of ``developments'' for these two source categories. The
commenter pointed out that the EPA identified several HAP control
advancements, including alternative coatings, developments for similar
source categories, and work practices and housekeeping measures for
metal coil facilities, which would reduce emissions and are in use at a
number of facilities, yet failed to determine that it was ``necessary''
to revise the standard. In addition, the
[[Page 10838]]
commenter alleged that the EPA technology review analysis did not
consider some relevant sources to determine ``developments.'' As
examples, the commenter stated that the EPA did not analyze any control
methods or requirements from other national or state or local
jurisdictions that might have proven more effective; did not appear to
analyze the different methods or brands of emission controls
implemented to see which was most effective, efficient, or reliable;
and did not examine facility procedures or best practices, including
records of malfunctions, to identify best practices to mitigate
malfunctions.
Response: We disagree with the commenter that the EPA has failed to
meet the CAA's legal obligation to complete the technology reviews for
the Surface Coating of Metal Cans and Surface Coating of Metal Coil
source categories. The EPA concluded there were no HAP control
advancements for these source categories as a result of the technology
reviews. The technology reviews included review of coatings currently
used by these source categories and any advancements in the coatings;
review of HAP control requirements in NESHAP for similar coating source
categories and application of those HAP controls to the Surface Coating
of Metal Cans and Surface Coating of Metal Coil source categories;
state and local HAP control requirements in facility title V operating
permits and application of those HAP controls to the Surface Coating of
Metal Cans and Surface Coating of Metal Coil source categories; and
work practices and housekeeping measures currently used by these source
categories and any advances that were applicable to these source
categories.
As stated in the proposal preamble (84 FR 25935) for the Surface
Coating of Metal Coil source category, alternatives to solvent borne
coatings have been in use by the coil coating industry since
development of the 2002 Surface Coating of Metal Coil NESHAP but are
not considered to be suitable for all end-product applications. The
2002 proposed NESHAP provided an alternative facility HAP emission
limit of 0.24 pounds of HAP per gallon of solids applied which was
established to provide a compliance option for facilities that chose to
limit their coating line HAP emissions either through a combination of
low-HAP coatings and add-on controls or through the use of waterborne,
high solids, or other pollution prevention coatings. The EPA found no
developments in alternative coating technologies during the technology
review that would result in achievable emission rates that are
substantially lower than those reflected in the current emission
limits.
The commenter also asserted that the EPA did not consider
developments in control methods for similar source categories and did
not analyze the regulations set by state or local jurisdictions that
might have proven more effective than the NESHAP requirements. We
disagree with the commenter and refer the commenter to the technology
review memorandums titled Technology Review for Surface Coating
Operations in the Metal Can Category and Technology Review for Surface
Coating Operations in the Metal Coil Category which summarizes the
EPA's review of the title V operating permits for the five metal can
facilities and for 39 metal coil facilities that are major sources and
subject to these NESHAP. The title V operating permits incorporate all
relevant local, state, or Regional emission limitations, as well as
federal limitations. In no case did the EPA find a facility subject to
a HAP limit more stringent than the limits in the current NESHAP or a
facility using a control technology that was not considered during
development of the NESHAP and reflected in the current standards. The
results of the technology reviews were documented in these memorandums
in the respective docket for each proposed rule.
The technology basis for MACT for metal coil coating operations in
the 2002 Surface Coating of Metal Coil NESHAP was emission capture and
add on control with an overall control efficiency of 98 percent for new
or reconstructed sources and existing sources. This overall control
efficiency represents the use of PTE to achieve 100-percent capture of
application station HAP emissions and a thermal oxidizer to achieve a
destruction efficiency of 98 percent. No technology was identified
during the technology review that could achieve a better overall
control efficiency than the use of a PTE to capture HAP emissions from
the coating application station and a thermal oxidizer to destroy HAP
emissions from the coating application and the curing oven.
It would not be feasible, nor is it required under CAA section
112(d)(6), for the EPA to evaluate HAP control advancement by examining
different brands of emission controls to see which was most effective,
efficient, or reliable, as suggested by the commenter. Similarly, it
would not be feasible to examine facility procedures or best practices,
nor review records of malfunctions to identify best practices to
mitigate malfunctions. That information is not currently available to
the EPA. If the information was available, it would be difficult, if
not impossible, to correlate that information with emissions
performance and develop practical regulatory requirements. Instead, the
current emission limits are based on actual performance of existing
sources in the two categories determined to represent the MACT level of
control for new and existing sources. The performance data used to
develop the emission limits were collected during emission tests when
the control devices were performing properly and the emission sources
were at steady-state operating conditions. Data collected during
periods of startup, shutdown, or malfunction were not used to establish
the emission limits. After the initial compliance demonstration,
facilities using add-on controls must comply with operating limits to
ensure the add-on controls continue to be properly operated and
maintained to achieve the same level of performance as during the
performance test. Facilities experiencing deviations from the emission
limits or the operating limits must report these deviations to the EPA,
and the EPA will then determine on a case-by-case basis whether the
deviation constitutes a violation. Because of the diversity of factors
that could lead to a malfunction in these source categories, it would
not be practical for the EPA to prescribe specific actions that must be
taken to reduce the frequency of malfunctions or to minimize emissions
in the event of a malfunction.
The commenter also asserted that the EPA identified work practices
and housekeeping measures for metal coil facilities, which would reduce
emissions and are in use at a number of facilities yet failed to
determine that it was ``necessary'' to revise the standard. The
commenter's assertion appears to be based on a statement in the
preamble to the proposal where we note that the facility survey
conducted as part of the development of the 2002 MACT standard for
Surface Coating of Metal Coil had revealed several types of work
practices and housekeeping measures in use at that time. (84 FR at
25935). We also noted in the preamble, however, that we had identified
no developments in work practices or procedures for the Surface Coating
of Metal Coil source category. As the commenter has provided no
additional information regarding possible developments and as the EPA
has no information about developments in such work practices and
housekeeping measures, we do not agree that it is necessary to revise
the
[[Page 10839]]
standard for this source category as a result of the technology review.
4. What is the rationale for our final approach for the technology
reviews?
For the reasons explained in the preamble to the proposed rules (84
FR 25922 and 25934, June 4, 2019), and in the comment responses above
in section IV.B.3 of this preamble, we are making no changes and are
finalizing the results of the technology reviews as proposed.
C. Electronic Reporting Provisions
1. What did we propose?
In the June 4, 2019, notice we proposed to require owners and
operators of surface coating of metal can and metal coil facilities to
submit electronic copies of notifications, reports, and performance
tests through the EPA's CDX, using the CEDRI. These include the initial
notifications required in 40 CFR 63.9(b) and 63.3510(b) for metal can
coating and 63.5180(b) for metal coil coating; notifications of
compliance status required in 40 CFR 63.9(h) and 63.3510(c) for metal
can coating and 63.5180(d) for metal coil coating; the performance test
reports required in 40 CFR 63.3511(b) for metal can coating and
63.5160(d) for metal coil coating; and the semiannual reports required
in 40 CFR 63.3511(a) for metal can coating and 63.5180(g) for metal
coil coating. A description of the electronic submission process is
provided in the memorandum, Electronic Reporting Requirements for New
Source Performance Standards (NSPS) and National Emission Standards for
Hazardous Air Pollutants (NESHAP), August 8, 2018, in the Surface
Coating of Metal Cans and Surface Coating of Metal Coil Dockets. The
proposed rule requirements would replace the current rule requirements
to submit the notifications and reports to the Administrator at the
appropriate address listed in 40 CFR 63.13. The proposed rule
requirement would not affect submittals required by state air agencies.
For metal can facilities, the proposed compliance schedule language in
40 CFR 63.3511(f) for submission of semiannual compliance reports would
have provided 181 days after the final rule is published to begin
electronic reporting or 1 year after the 40 CFR part 63, subpart KKKK
semiannual compliance report template is available in CEDRI, whichever
is later. For metal coil facilities, the proposed compliance schedule
language in 40 CFR 63.5181(c) for submission of semiannual compliance
reports would have provided 1 year after the final rule is published to
begin electronic reporting or 1 year after the 40 CFR part 63, subpart
SSSS semiannual compliance report template is available in CEDRI,
whichever is later.
2. What changed since proposal?
For metal can facilities, the compliance schedule language in
proposed 40 CFR 63.3511(f) for submission of semiannual compliance
reports has been revised from the proposed 181 days, to either 1 year
after the final rule is published or 1 year after the 40 CFR part 63,
subpart KKKK, semiannual compliance report template is available in
CEDRI, whichever is later. No changes were made to the metal coil
compliance schedule.
3. What key comments did we receive and what are our responses?
Comment: One commenter suggested that the EPA change the metal can
compliance schedule language in proposed 40 CFR 63.3511(f) for
submission of semiannual compliance reports to give facilities either
1year (instead of 181 days) after the final rule is published to begin
electronic reporting or 1 year after the 40 CFR part 63, subpart KKKK,
semiannual compliance report template is available in CEDRI, whichever
is later. The commenter recommended revising 40 CFR 63.3511(f) to say
that on and after the date 1 year (instead of 181 days) after the date
of publication of the final rule in the Federal Register, or once the
reporting template has been available on the CEDRI website for 1 year,
whichever date is later, the owner or operator is required to submit
the semiannual compliance report via the CEDRI. The commenter noted
that the proposed 181-day requirement for 40 CFR part 63, subpart KKKK,
is not consistent with the 1-year requirement the EPA is proposing for
40 CFR 63.5181(c) in 40 CFR part 63, subpart SSSS for the Surface
Coating of Metal Coil source category. The commenter also argued that 1
year would be justified because metal can coating facilities are not
currently using CEDRI and would need to learn how to access and use
CEDRI.
Response: The EPA agrees that both rules should be consistent and
that the owners and operators should have 1 year after the date of
publication of the final rule or 1 year after the reporting template
has been on CEDRI, whichever is later, before they are required to
submit semiannual compliance reports via CEDRI. This will provide users
1 year to become familiar with the template and electronic reporting
system prior to being required to submit reports electronically. This
will provide adequate time for facilities to adjust to electronic
reporting, as well as assure that the forms will work properly, prior
to the date that owners and operators must start submitting these
reports electronically. The EPA encourages users to become familiar
with the system well in advance of being required to use it. For
previous rulemakings with reports required to be submitted
electronically via CEDRI, prior to a compliance reporting deadline, the
EPA has provided webinars to our various stakeholders on the access and
reporting of the given report in CEDRI. The EPA is planning to provide
this same service to the industry trade association and facilities
subject to the 40 CFR part 63, subparts KKKK and SSSS electronic
reporting requirements, if requested to do so. The EPA plans to publish
the final template on CEDRI about the same time the final rule is
signed and published. Although facilities will have up to 1 year after
the final template is on CEDRI to begin using the template and
submitting reports via CEDRI, facilities may begin submitting reports
via CEDRI as soon as the final template is available.
Comment: One commenter stated they will need an interactive
discussion with the EPA (e.g., by conference call or webinar) to answer
questions about how to use CEDRI and about the draft electronic
reporting template before they can effectively comment on whether the
template is appropriate and workable for metal can surface coating
facilities subject to subpart 40 CFR part 63, KKKK. The commenter
further asked that the EPA not finalize the reporting template until
after the proposed rule is finalized.
Response: The EPA agrees that interactive discussions via
conference calls or a webinar with the industry trade organization and
members would be appropriate to review the electronic reporting process
using CEDRI and to collaborate on improvements to the draft electronic
reporting template. The EPA has arranged interactive discussions with
both the metal can and metal coil industry trade organizations and
members in an attempt to finalize the electronic reporting templates
concurrent with the final rule promulgation. If that is the case
facilities will have 1 year after the final rule is published to submit
notifications and semiannual compliance reports using the electronic
reporting template in CEDRI. If the reporting templates are not
finalized concurrent with the final rule promulgation, the EPA will
continue to work with the industry trade organizations and members to
finalize the templates and will make the final templates available on
the CEDRI
[[Page 10840]]
website. Facilities would then be required to submit notifications and
semiannual compliance reports using the electronic reporting template
in CEDRI one year after the reporting template has been available on
the CEDRI website.
4. What is the rationale for our final approach for the electronic
reporting provisions?
For the reasons explained in the preamble to the proposed rules (84
FR 25922 and 25934, June 4, 2019), and in the comment responses above
in section IV.C.3 of this preamble, we are finalizing the electronic
reporting provisions for both 40 CFR parts 63, subparts KKKK and SSSS,
as proposed with the exception of the change in date by which
electronic reporting must commence for the Surface Coating of Metal
Cans source category (described in section IV.C.2 of this preamble).
D. SSM Provisions
1. What did we propose?
In the June 4, 2019, action, we proposed amendments to the Surface
Coating of Metal Cans NESHAP and the Surface Coating of Metal Coil
NESHAP to remove and revise provisions related to SSM that are not
consistent with the requirement that the standards apply at all times.
More information concerning the elimination of SSM provisions is in the
preamble to the proposed rule (84 FR 25909, June 4, 2019).
2. What changed since proposal?
We are finalizing the SSM provisions as proposed with no changes
(84 FR 25909, June 4, 2019).
3. What key comments did we receive and what are our responses?
Comment: One commenter noted that new language has been proposed
for 40 CFR 63.5150(a) which states that on and after the compliance
date sources must also maintain the monitoring equipment at all times
in accordance with 40 CFR 63.5140(b) and keep the necessary parts
readily available for routine repairs of the monitoring equipment. The
commenter expressed concern that different inspectors could have
different interpretations of what parts would be ``necessary'' to be
kept readily available and what repairs would be ``routine.'' The
commenter recommended revising the proposed language for 40 CFR
63.5150(a) to omit ``and keep the necessary parts readily available for
routine repairs of the monitoring equipment.''
The commenter argued that the compliance requirement language will
always be open to some degree of interpretation, but the suggested
change would minimize differences in how this new language is
interpreted and allow the individual facilities to manage and defend
their compliance practices required in this section as they see best.
Response: The EPA disagrees with the commenter and is not accepting
this recommended change. The requirement is not new, it was simply
moved from the 40 CFR part 63 General Provisions to subparts KKKK and
SSSS. The language proposed for 40 CFR 63.5150(a) replaces language in
40 CFR 63.8(c)(1)(i) and (ii) that no longer applies. The EPA is
amending Table 5 to Subpart KKKK of Part 63 so that 40 CFR 63.8(c)(1)
no longer applies because 40 CFR 63.8(c)(1)(iii) requires, ``The owner
or operator of an affected source must develop a written startup,
shutdown, and malfunction plan for CMS as specified in Sec.
63.6(e)(3).'' Because 40 CFR 63.8(c)(1) no longer applies as part of
the amendments to remove the SSM exemptions, the provisions of 40 CFR
63.8(c)(1)(i) and (ii) are being added to each subpart. The EPA
disagrees that the proposed language would lead to differences in
interpretation and the commenter provided no evidence that the same
language led to compliance issues when it was located only in 40 CFR
63.8(c)(1)(ii).
4. What is the rationale for our final approach for the SSM provisions?
For the reasons explained in the proposed rule and after evaluation
of the comments on the proposed amendments to the SSM provisions for
the Surface Coating of Metal Cans NESHAP and the Surface Coating of
Metal Coil NESHAP, we are finalizing the proposed revisions related to
SSM that are not consistent with the requirement that the standards
apply at all times. More information concerning the proposed amendments
to the SSM provisions is in the preamble to the proposed rule (84 FR
25909, June 4, 2019).
E. Ongoing Compliance Demonstrations
1. What did we propose?
In the June 4, 2019, action we proposed to require owners and
operators of surface coating of metal can facilities and surface
coating of metal coil facilities to conduct periodic performance
testing of add-on control devices on a regular frequency of every 5
years to ensure the equipment continues to operate properly for
facilities using the emission rate with add-on controls compliance
option. This proposed periodic testing requirement included an
exception to the general requirement for periodic testing for
facilities using the catalytic oxidizer control options and following
catalyst maintenance procedures that are found in both 40 CFR part 63,
subparts KKKK and SSSS. These catalyst maintenance procedures include
annual testing of the catalyst and other maintenance procedures that
provide ongoing demonstrations that the control system is operating
properly and may, thus, be considered comparable to conducting a
performance test. The proposed periodic performance testing requirement
also allows an exception from periodic testing for facilities using
CEMS to show actual emissions. The use of CEMS to demonstrate
compliance would obviate the need for periodic testing.
This proposed requirement did not require periodic testing or CEMS
monitoring of facilities using the compliant materials option or the
emission-rate without add-on controls compliance option because these
two compliance options do not use any add-on controls or control
efficiency measurements in the compliance calculations.
The proposed periodic performance testing requirement requires
facilities complying with the standards using emission capture systems
and add-on controls and which are not already on a 5-year testing
schedule to conduct the first of the periodic performance tests within
3 years of the effective date of the revised standards. Afterward, they
would generally conduct periodic testing before they renew their title
V operating permits, but in no case more than 5 years following the
previous performance test. Additionally, facilities that have already
tested as a condition of their permit within the last 2 years before
the effective date would be permitted to maintain their current 5-year
schedule.
2. What changed since proposal?
We have revised the proposed periodic testing language in 40 CFR
part 63, subparts KKKK and SSSS, since proposal to clarify that
facilities already conducting comparable periodic testing as a
requirement of renewing their title V operating permit under 40 CFR
part 70 or part 71 may continue with their current testing schedule. We
also reformatted the electronic reporting language in 40 CFR part 63,
subparts KKKK and SSSS, to provide clarification on the requirements
for asserting a claim of EPA system outage or force majeure for failure
to timely comply with the reporting requirements.
[[Page 10841]]
3. What key comments did we receive and what are our responses?
Comment: One commenter recommended that language in the proposed
rule for 40 CFR part 63, subpart KKKK should be revised to more clearly
state that facilities are permitted to use the performance tests
conducted under their title V permits, as required by state and local
permitting authorities, to meet the proposed requirement for periodic
performance testing under 40 CFR part 63, subpart KKKK. The commenter
suggested that the EPA modify the proposed language for 40 CFR
63.3540(a)(1)(ii), 63.3540(b)(1)(ii), 63.3550(a)(1)(ii), and
63.3550(b)(1)(ii) and offered clarifying language to say that if a
source is not required to complete periodic performance tests as a
requirement of renewing its title V operating permit under 40 CFR part
70 or 40 CFR part 71, it must conduct the first periodic performance
test before the date 3 years after date of publication of the final
rule in the Federal Register, unless the source has already conducted a
performance test on or after the date 2 years before the date of
publication of the final rule in the Federal Register. The commenter
then suggested adding language to say that if a source is already
required to complete periodic performance tests as a requirement of
renewing its title V operating permit under 40 CFR part 70 or 40 CFR
part 71, it must conduct the periodic testing in accordance with the
terms and schedule required by its permit conditions.
Response: The EPA agrees that the recommended changes would clarify
that facilities can continue to use tests conducted under title V to
meet the 40 CFR part 63, subpart KKKK requirement to conduct periodic
performance tests. The EPA is making the recommended changes to 40 CFR
63.3540(a)(1)(ii), 63.3540(b)(1)(ii), 63.3550(a)(1)(ii), and
63.3550(b)(1)(ii) and is making comparable changes to Table 1 To 40 CFR
63.5160--Required Performance Testing Summary, in 40 CFR part 63,
subpart SSSS.
4. What is the rationale for our final approach for the ongoing
compliance demonstrations?
For the reasons explained in the preamble to the proposed rules (84
FR 25922 and 25934, June 4, 2019), and in the comment responses above
in section IV.C.3 of this preamble, we are finalizing the periodic
testing provisions for both 40 CFR part 63, subparts KKKK and SSSS, as
proposed with the exception of the rule clarification change described
for 40 CFR part 63, subparts KKKK and SSSS in section IV.D.2 of this
preamble.
V. Summary of Cost, Environmental, and Economic Impacts and Additional
Analyses Conducted
A. What are the affected sources?
Currently, five major sources subject to the Surface Coating of
Metal Cans NESHAP are operating in the United States. The affected
source under the NESHAP is the collection of all equipment used to
apply coating to a metal can or end (including decorative tins), or
metal crown or closure, and to dry or cure the coating after
application; all storage containers and mixing vessels in which
coatings, thinners, and cleaning materials are stored or mixed; all
manual and automated equipment and containers used for conveying
coatings, thinners, and cleaning materials; and all storage containers
and all manual and automated equipment and containers used for
conveying waste materials generated by the coating operations. A
coating operation always includes at least the point at which a coating
is applied and all subsequent points in the affected source where
organic HAP emissions from that coating occur. There may be multiple
coating operations in an affected source.
Currently, 48 major sources subject to the Surface Coating of Metal
Coil NESHAP are operating in the United States. The affected source
under the NESHAP is the collection of all the coil coating lines at a
facility, including the equipment used to apply an organic coating to
the surface of metal coil. A coil coating line includes a web unwind or
feed section, a series of one or more work stations, and any associated
curing oven, wet section, and quench station. A coil coating line does
not include ancillary operations such as mixing/thinning, cleaning,
wastewater treatment, and storage of coating material. Metal coil is a
continuous metal strip that is at least 0.15 mm (0.006 inch) thick,
which is packaged in a roll or coil prior to coating. Material less
than 0.15 mm (0.006 inch) thick is considered metal foil, not metal
coil. The NESHAP applies to coating lines on which more than 15 percent
of the material coated, based on surface area, meets the definition of
metal coil. There may be multiple coating operations in an affected
source.
B. What are the air quality impacts?
The EPA estimates the current emissions of volatile organic HAP
from the Surface Coating of Metal Cans source category are
approximately 77 tpy and the current emissions of volatile organic HAP
from the Surface Coating of Metal Coil source category are
approximately 291 tpy.
The amendments require that all 53 major sources in the Surface
Coating of Metal Cans and Surface Coating of Metal Coil source
categories comply with the relevant emission standards at all times,
including periods of SSM. We were unable to quantify the emissions that
occur during periods of SSM or the specific emissions reductions that
will occur as a result of this action. However, eliminating the SSM
exemption has the potential to reduce emissions by requiring facilities
to meet the applicable standard during SSM periods.
The amendments will have no effect on the energy needs of the
affected facilities in either of the two source categories and will,
therefore, have no adverse energy impacts or indirect or secondary air
emissions impacts. Energy impacts consist of the electricity and steam
needed to operate control devices and other equipment. Indirect or
secondary air emissions impacts are impacts that would result from the
increased energy usage associated with the operation of control devices
(e.g., increased secondary emissions of criteria pollutants from power
plants).
C. What are the cost impacts?
We estimate that each facility in these two source categories will
experience increased costs as a result of these final amendments for
recordkeeping and reporting. Each facility will experience costs to
read and understand the rule amendments. Costs associated with
elimination of the SSM exemption were estimated as part of the
reporting and recordkeeping costs and include time for re-evaluating
and modifying, as necessary, previously developed SSM record systems.
Costs associated with the requirement to electronically submit
notifications and semi-annual compliance reports using CEDRI were
estimated as part of the reporting and recordkeeping costs and include
time for becoming familiar with CEDRI and the reporting template for
semi-annual compliance reports. The recordkeeping and reporting costs
are presented in section VI.C of this preamble.
We are also finalizing a requirement for performance testing no
less frequently than every 5 years for sources in each source category
that use the add-on controls compliance options. We estimate that the
new periodic testing requirement will impose additional costs for 22
facilities across the two source categories. We estimate that one
facility using three add-on control devices subject to the Surface
Coating of
[[Page 10842]]
Metal Cans NESHAP will incur costs to conduct control device
performance testing because it is using the emission rate with add-on
controls compliance option and is not required by its title V operating
permit to conduct testing every 5 years. We estimate that 21 facilities
subject to the Surface Coating of Metal Coil NESHAP will incur costs to
conduct periodic testing because they are currently using the emission
rate with add-on controls compliance option and are not required by
their title V operating permits to conduct testing every 5 years. These
21 metal coil coating facilities have a total of 30 add-on control
devices. This total does not include facilities in the Surface Coating
of Metal Coil source category that have add-on controls and are
currently required to perform periodic performance testing as a
condition of their title V operating permit. The cost for a facility to
conduct a destruction or removal efficiency performance test using EPA
Method 25 or 25A is estimated to be about $19,000, with tests of
additional control devices at the same facility costing 25 percent less
due to reduced travel costs. The estimated total cost for the one metal
can surface coating facility to test three add-on control devices in a
single year would be $47,000. The estimated total cost for all 21 metal
coil facilities to test 30 add-on control devices in a single year,
plus two retests to account for 5 percent of control devices failing to
pass the first test, would be $560,000. The total annualized testing
cost is estimated to be approximately $11,000 per year for the Surface
Coating of Metal Cans source category, and $130,000 per year for the
Surface Coating of Metal Coil source category, including retests. In
addition to the testing costs, each facility performing a test will
have an estimated additional $5,500 in reporting costs in the year in
which the test occurs.
As a result of changes to recordkeeping and reporting requirements,
a one-time review of the updated rule language, and the addition of the
periodic testing requirement for facilities using add-on controls, the
costs of the final amendments are estimated to be $21,800 for the
Surface Coating of Metal Cans source category and $271,000 for the
Surface Coating of Metal Coil source category averaged over the first 3
years after the amendments are finalized. For further information on
the estimated costs, see the cost tables in the memoranda titled
Estimated Costs/Impacts of the 40 CFR part 63 Subparts KKKK and SSSS
Monitoring Review Revisions, February 2019, and the Economic Impact and
Small Business Screening Assessments for Hazardous Air Pollutants for
Metal Cans Coating Plants (Subpart KKKK) and the Economic Impact and
Small Business Screening Assessments for Hazardous Air Pollutants for
Metal Coil Coating Plants (Subpart SSSS) in the Surface Coating of
Metal Cans and Surface Coating of Metal Coil Dockets.
D. What are the economic impacts?
The economic impact analysis is designed to inform decision makers
about the potential economic consequences of a regulatory action. For
the final revisions, the EPA estimated the cost of becoming familiar
with the rule and re-evaluating and revising, as necessary, previously
developed SSM record systems and performing periodic emissions testing
at certain facilities with add-on controls that are not already
required to perform testing. To assess the maximum potential impact,
the largest cost expected to be experienced in any 1 year is compared
to the total sales for the ultimate owners of the affected facilities
to estimate the total burden for each ultimate owner.
For the final revisions to the NESHAP for the Surface Coating of
Metal Cans, the annualized cost is estimated to be $11,000 for the five
affected entities. The five affected facilities are owned by three
different parent companies, and the total costs associated with the
final requirements range from 0.00002 to 0.77 percent of annual sales
revenue per ultimate owner. These costs are not expected to result in a
significant market impact, regardless of whether they are passed on to
the purchaser or absorbed by the firms.
For the final revisions to the NESHAP for the Surface Coating of
Metal Coil, the annualized cost is estimated to be $130,000 for the 48
affected entities. The 48 affected facilities are owned by 25 different
parent companies, and the total costs associated with the proposed
requirements range from 0.00001 to 0.28 percent of annual sales revenue
per ultimate owner. These costs are not expected to result in a
significant market impact, regardless of whether they are passed on to
the purchaser or absorbed by the firms.
The EPA also prepared a small business screening assessment to
determine whether any of the identified affected entities are small
entities, as defined by the U.S. Small Business Administration. One of
the facilities potentially affected by the final revisions to the
NESHAP for the Surface Coating of Metal Cans is a small entity. Ten of
the facilities potentially affected by the final revisions to the
NESHAP for the Surface Coating of Metal Coil are small entities.
However, the annualized costs associated with the final revisions for
the seven ultimate owners of these eleven affected small entities range
from 0.0029 to 0.77 percent of annual sales revenues per ultimate
owner. Therefore, there are no significant economic impacts on a
substantial number of small entities from these final amendments.
More information and details of this analysis are provided in the
technical documents titled Economic Impact and Small Business Screening
Assessments for Proposed Amendments to the National Emission Standards
for Hazardous Air Pollutants for the Surface Coating of Metal Cans
(Subpart KKKK) and Economic Impact and Small Business Screening
Assessments for Proposed Amendments to the National Emission Standards
for Hazardous Air Pollutants for the Surface Coating of Metal Coil
(Subpart SSSS), available in the Surface Coating of Metal Cans and
Surface Coating of Metal Coil Dockets, respectively.
E. What are the benefits?
As stated above in section V.B of this preamble, we were unable to
quantify the specific emissions reductions associated with eliminating
the SSM exemption or as a result of adding the requirement to conduct
periodic add-on control device performance tests, although these final
revisions have the potential to reduce emissions of volatile organic
HAP.
Because these final amendments are not considered economically
significant, as defined by Executive Order 12866, and because we were
unable to quantify the specific emission reductions that will occur as
a result of this action, we did not monetize the benefits of reducing
these emissions. This does not mean that there are no benefits
associated with the potential reduction in volatile organic HAP from
this rule.
F. What analysis of environmental justice did we conduct?
Executive Order 12898 (59 FR 7629, February 16, 1994) establishes
federal executive policy on environmental justice. Its main provision
directs federal agencies, to the greatest extent practicable and
permitted by law, to make environmental justice part of their mission
by identifying and addressing, as appropriate, disproportionately high
and adverse human health or environmental effects of their programs,
policies, and activities on minority populations and low-income
populations in the United States.
[[Page 10843]]
To examine the potential for any environmental justice issues that
might be associated with these source categories, we performed a
demographic analysis for each source category, which is an assessment
of risks to individual demographic groups of the populations living
within 5 kilometers (km) and within 50 km of the facilities. In these
analyses, we evaluated the distribution of HAP-related cancer and
noncancer risks from each source category across different demographic
groups within the populations living near facilities.
1. Surface Coating of Metal Cans
The results of the demographic analysis for the Surface Coating of
Metal Cans source category are summarized in Table 4 of this preamble.
These results, for various demographic groups, are based on the
estimated risk from actual emissions levels for the population living
within 50 km of the facilities.
The results of the Surface Coating of Metal Cans source category
demographic analysis indicate that emissions from the source category
expose approximately 700 people to a cancer risk at or above 1-in-1
million and no one to a chronic noncancer TOSHI greater than 1. The
percentages of the population exposed to emissions from the source
category in three demographic groups (White, Above Poverty Level, and
Over 25 with a High School Diploma) are greater than their respective
nationwide percentages. The methodology and the results of the
demographic analysis are presented in more detail in the technical
report titled Risk and Technology Review--Analysis of Demographic
Factors for Populations Living Near Surface Coating of Metal Cans
Source Category Operations, May 2018, in the Surface Coating of Metal
Cans Docket.
Table 4--Surface Coating of Metal Cans Source Category Demographic Risk Analysis Results
----------------------------------------------------------------------------------------------------------------
Population with cancer Population with chronic
risk at or above 1-in-1 noncancer HI above 1
Nationwide million due to surface due to surface coating
coating of metal cans of metal cans
----------------------------------------------------------------------------------------------------------------
Total Population.............................. 317,746,049 700 0
----------------------------------------------------------------------------------------------------------------
White and Minority by Percent
----------------------------------------------------------------------------------------------------------------
White......................................... 62 92 0
Minority...................................... 38 8 0
----------------------------------------------------------------------------------------------------------------
Minority by Percent
----------------------------------------------------------------------------------------------------------------
African American.............................. 12 0 0
Native American............................... 0.8 0 0
Hispanic...................................... 18 4 0
Other and Multiracial......................... 7 4 0
----------------------------------------------------------------------------------------------------------------
Income by Percent
----------------------------------------------------------------------------------------------------------------
Below Poverty Level........................... 14 4 0
Above Poverty Level........................... 86 96 0
----------------------------------------------------------------------------------------------------------------
Education by Percent
----------------------------------------------------------------------------------------------------------------
Over 25 and without High School Diploma....... 14 4 0
Over 25 and with a High School Diploma........ 86 96 0
----------------------------------------------------------------------------------------------------------------
Linguistically Isolated by Percent
----------------------------------------------------------------------------------------------------------------
Linguistically Isolated....................... 6 0 0
----------------------------------------------------------------------------------------------------------------
2. Surface Coating of Metal Coil
The results of the demographic analysis for the Surface Coating of
Metal Coil source category are summarized in Table 5 of this preamble.
These results, for various demographic groups, are based on the
estimated risk from actual emissions levels for the population living
within 50 km of the facilities.
The results of the Surface Coating of Metal Coil source category
demographic analysis indicate that emissions from the source category
expose approximately 19,000 people to a cancer risk at or above 1-in-1
million and no one is exposed to a chronic noncancer TOSHI greater than
1. The percentages of the population exposed to emissions from the
source category in three demographic groups (White, African American,
and Over 25 and with a High School Diploma) are greater than their
respective nationwide percentages.
The methodology and the results of the demographic analysis are
presented in a technical report, Risk and Technology Review--Analysis
of Demographic Factors for Populations Living Near Surface Coating of
Metal Coil Source Category Operations, May 2017, available in the
Surface Coating of Metal Coil Docket.
[[Page 10844]]
Table 5--Surface Coating of Metal Coil Source Category Demographic Risk Analysis Results
----------------------------------------------------------------------------------------------------------------
Population with cancer Population with chronic
risk at or above 1-in-1 noncancer HI above 1
Nationwide million due to surface due to surface coating
coating of metal coil of metal coil
----------------------------------------------------------------------------------------------------------------
Total Population.............................. 317,746,049 19,000 0
----------------------------------------------------------------------------------------------------------------
White and Minority by Percent
----------------------------------------------------------------------------------------------------------------
White......................................... 62 70 0
Minority...................................... 38 30 0
----------------------------------------------------------------------------------------------------------------
Minority by Percent
----------------------------------------------------------------------------------------------------------------
African American.............................. 12 21 0
Native American............................... 0.8 0.1 0
Hispanic...................................... 18 4 0
Other and Multiracial......................... 7 5 0
----------------------------------------------------------------------------------------------------------------
Income by Percent
----------------------------------------------------------------------------------------------------------------
Below Poverty Level........................... 14 15 0
Above Poverty Level........................... 86 85 0
----------------------------------------------------------------------------------------------------------------
Education by Percent
----------------------------------------------------------------------------------------------------------------
Over 25 and without High School Diploma....... 14 10 0
Over 25 and with a High School Diploma........ 86 90 0
----------------------------------------------------------------------------------------------------------------
Linguistically Isolated by Percent
----------------------------------------------------------------------------------------------------------------
Linguistically Isolated....................... 6 1 0
----------------------------------------------------------------------------------------------------------------
G. What analysis of children's environmental health did we conduct?
This action is not subject to Executive Order 13045 because it is
not economically significant as defined in Executive Order 12866, and
because the EPA does not believe the environmental health or safety
risks addressed by this action present a disproportionate risk to
children. This action's health and risk assessments are summarized in
section IV.A of this preamble and are further documented in the
Residual Risk Assessment for the Surface Coating of Metal Cans Source
Category in Support of the 2019 Risk and Technology Review Proposed
Rule, and the Residual Risk Assessment for the Surface Coating of Metal
Coil Source Category in Support of the 2019 Risk and Technology Review
Proposed Rule, in the Surface Coating of Metal Cans and Surface Coating
of Metal Coil Dockets, respectively.
VI. Statutory and Executive Order Reviews
Additional information about these statutes and Executive Orders
can be found at https://www.epa.gov/laws-regulations/laws-and-executive-orders.
A. Executive Order 12866: Regulatory Planning and Review and Executive
Order 13563: Improving Regulation and Regulatory Review
This action is not a significant regulatory action and was,
therefore, not submitted to Office of Management and Budget (OMB) for
review.
B. Executive Order 13771: Reducing Regulations and Controlling
Regulatory Costs
This action is not an Executive Order 13771 regulatory action
because this action is not significant under Executive Order 12866.
C. Paperwork Reduction Act (PRA)
The information collection activities in this action have been
submitted for approval to OMB under the PRA, as discussed for each
source category covered by this action in sections VI.C.1 and 2.
1. Surface Coating of Metal Cans
The Information Collection Request (ICR) document that the EPA
prepared for this source category has been assigned EPA ICR number
2079.08. You can find a copy of the ICR document in the Surface Coating
of Metal Cans Docket (Docket ID No. EPA-HQ-OAR-2017-0684), and it is
briefly summarized here. The information collection requirements are
not enforced until OMB approves them.
As part of the RTR for the Surface Coating of Metal Cans NESHAP,
the EPA is not revising the emission limit requirements. The EPA is
revising the SSM provisions of the rule and requiring the use of
electronic data reporting for future performance test data submittals,
notifications, and reports. This information is being collected to
assure compliance with 40 CFR part 63, subpart KKKK.
Respondents/affected entities: Facilities performing surface
coating of metal cans.
Respondent's obligation to respond: Mandatory (40 CFR part 63,
subpart KKKK).
Estimated number of respondents: In the 3 years after the
amendments are final, approximately five respondents per year will be
subject to the NESHAP and no additional respondents are expected to
become subject to the NESHAP during that period.
Frequency of response: The total number of responses in year 1 is
15 and in year 3 is one. Year 2 would have no responses.
Total estimated burden: The average annual information collection
burden to the five metal can facilities over the 3 years after the
amendments are finalized is estimated to be 54 hours (per year). The
average annual burden to the
[[Page 10845]]
Agency over the 3 years after the amendments are finalized is estimated
to be 23 hours (per year). Burden is defined at 5 CFR 1320.3(b).
Total estimated cost: The average annual labor cost to the metal
can facilities is estimated to be $6,200 in the first 3 years after the
amendments are finalized. The average annual capital and operation and
maintenance (O&M) cost is estimated to be $15,600 over this period. The
average annual Agency cost over the first 3 years after the amendments
are finalized is estimated to be $1,090.
2. Surface Coating of Metal Coil
The ICR document that the EPA prepared for this source category has
been assigned EPA ICR number 1957.10. You can find a copy of the ICR
document in the Surface Coating of Metal Coil Docket (Docket ID No.
EPA-HQ-OAR-2017-0685), and it is briefly summarized here. The
information collection requirements are not enforced until OMB approves
them.
As part of the RTR for the Surface Coating of Metal Coil NESHAP,
the EPA is not revising the emission limit requirements. The EPA is
revising the SSM provisions of the rule and requiring the use of
electronic data reporting for future performance test data submittals,
notifications, and reports. This information is being collected to
assure compliance with 40 CFR part 63, subpart SSSS.
Respondents/affected entities: Facilities performing surface
coating of metal coil.
Respondent's obligation to respond: Mandatory (40 CFR part 63,
subpart SSSS).
Estimated number of respondents: In the 3 years after the
amendments are finalized, approximately 48 respondents per year will be
subject to the NESHAP and no additional respondents are expected to
become subject to the NESHAP during that period.
Frequency of response: The total number of responses in year 1 is
144 and in year 3 is 69. Year 2 would have no responses.
Total estimated burden: The average annual burden to the 48 metal
coil coating facilities over the 3 years after the amendments are
finalized is estimated to be 738 hours (per year). The average annual
burden to the Agency over the 3 years after the amendments are
finalized is estimated to be 179 hours (per year). Burden is defined at
5 CFR 1320.3(b).
Total estimated cost: The average annual cost to the 48 metal coil
coating facilities is estimated to be $85,000 in labor costs and
$186,000 in capital and O&M costs in the first 3 years after the
amendments are finalized. The average annual Agency cost over the first
3 years after the amendments are finalized is estimated to be $8,530.
An agency may not conduct or sponsor, and a person is not required
to respond to, a collection of information unless it displays a
currently valid OMB control number. The OMB control numbers for the
EPA's regulations in 40 CFR are listed in 40 CFR part 9. When OMB
approves the ICRs, the Agency will announce that approval in the
Federal Register and publish a technical amendment to 40 CFR part 9 to
display the OMB control number for the approved information collection
actions contained in the final rule.
D. Regulatory Flexibility Act (RFA)
I certify that this action will not have a significant economic
impact on a substantial number of small entities under the RFA. The
eleven small entities that are subject to the requirements of this
action are small businesses. The Agency has determined that the seven
ultimate owners of these eleven affected small entities (21 percent of
the facilities affected by this action) so impacted may experience an
impact of 0.0029 to 0.77 percent of annual sales revenues per ultimate
owner. Details of this analysis are described in section V.D above and
in the economic impact memorandums located in the dockets for this
action.
E. Unfunded Mandates Reform Act (UMRA)
This action does not contain an unfunded mandate of $100 million or
more as described in UMRA, 2 U.S.C. 1531-1538, and does not
significantly or uniquely affect small governments. The action imposes
no enforceable duty on any state, local, or tribal governments or the
private sector.
F. Executive Order 13132: Federalism
This action does not have federalism implications. It will not have
substantial direct effects on the states, on the relationship between
the national government and the states, or on the distribution of power
and responsibilities among the various levels of government.
G. Executive Order 13175: Consultation and Coordination With Indian
Tribal Governments
This action does not have tribal implications as specified in
Executive Order 13175. No tribal facilities are known to be engaged in
any of the industries that would be affected by this action (metal can
surface coating and metal coil surface coating). Thus, Executive Order
13175 does not apply to this action.
H. Executive Order 13045: Protection of Children From Environmental
Health Risks and Safety Risks
This action is not subject to Executive Order 13045 because it is
not economically significant as defined in Executive Order 12866, and
because the EPA does not believe the environmental health or safety
risks addressed by this action present a disproportionate risk to
children. This action's health and risk assessments are contained in
sections III.A and C, IV.A.1 and 2, IV.B.1 and 2, and IV.C.1 and 2 of
the proposal preamble (84 FR 25904, June 4, 2019) and are further
documented in the Residual Risk Assessment for the Surface Coating of
Metal Cans Source Category in Support of the 2019 Risk and Technology
Review Proposed Rule and the Residual Risk Assessment for the Surface
Coating of Metal Coil Source Category in Support of the 2019 Risk and
Technology Review Proposed Rule in the Surface Coating of Metal Cans
Docket and the Surface Coating of Metal Coil Docket, respectively.
I. Executive Order 13211: Actions Concerning Regulations That
Significantly Affect Energy Supply, Distribution, or Use
This action is not subject to Executive Order 13211 because it is
not a significant regulatory action under Executive Order 12866.
J. National Technology Transfer and Advancement Act (NTTAA) and 1 CFR
Part 51
This rulemaking involves technical standards. The EPA amended the
Surface Coating of Metal Coil NESHAP in this action to provide owners
and operators with the option of conducting two new methods: EPA Method
18 of appendix A to 40 CFR part 60, ``Measurement of Gaseous Organic
Compound Emissions by Gas Chromatography,'' to measure and subtract
methane emissions from measured total gaseous organic mass emissions as
carbon, and ASTM Method D1475-13, ``Standard Test Method for Density of
Liquid Coatings, Inks, and Related Products.'' We are incorporating
ASTM Method D1475-13 by reference. We are adding these two standards to
the Surface Coating of Metal Coil NESHAP only, as these methods are
already provided in the Surface Coating of Metal Cans NESHAP.
The EPA is also amending the Surface Coating of Metal Cans NESHAP
to update three ASTM test methods and
[[Page 10846]]
amend the Surface Coating of Metal Coil NESHAP to update two ASTM test
methods. We are updating ASTM Method D1475-90, ``Standard Test Method
for Density of Liquid Coatings, Inks, and Related Products,'' in the
Surface Coating of Metal Cans NESHAP by incorporating by reference ASTM
Method D1475-13. The updated version, ASTM Method D1475-13, clarifies
units of measure and reduces the number of determinations required. We
are updating ASTM Method D2697-86 (1998), ``Standard Test Method for
Volume Nonvolatile Matter in Clear or Pigmented Coatings,'' in both the
Surface Coating of Metal Cans and the Surface Coating of Metal Coil
NESHAP by incorporating by reference ASTM D2697-03 (2014), which is the
updated version of the previously approved method. We are also updating
ASTM Method D6093-97 (2003), ``Standard Test Method for Percent Volume
Nonvolatile Matter in Clear or Pigmented Coatings Using Helium Gas
Pycnometer,'' in both the Surface Coating of Metal Cans and the Surface
Coating of Metal Coil NESHAP by incorporating by reference ASTM D6093-
97 (2016), which is the updated version of the previously approved
method. ASTM D2697-03 (2014) is a test method that can be used to
determine the volume of nonvolatile matter in clear and pigmented
coatings and ASTM D6093-97 (2016) is a test method that can be used to
determine the percent volume of nonvolatile matter in clear and
pigmented coatings.
For the Surface Coating of Metal Cans NESHAP and the Surface
Coating of Metal Coil NESHAP, we are incorporating by reference ASTM
D2369-10 (2015), ``Test Method for Volatile Content of Coatings,'' as
an alternative to EPA Method 24 for the determination of the volatiles
emitted by the surface coatings. The test method determines the weight
percent volatile content of solvent borne and water borne coatings
under specified test conditions. It is viable for coatings wherein one
or more parts may, at ambient conditions, contain liquid co-reactants
that are volatile until a chemical reaction has occurred with another
component of a multi-package system.
For the Surface Coating of Metal Cans and the Surface Coating of
Metal Coil NESHAP, we are incorporating by reference ASTM D2111-10
(2015), ``Standard Test Methods for Specific Gravity and Density of
Halogenated Organic Solvents and Their Admixtures,'' for the
determination of the specific gravity of halogenated organic solvents
and solvent admixtures in surface coatings. ASTM D2111-10 (2015)
includes three test methods to measure specific gravity using suitable
apparatus (i.e., a hydrometer, a pycnometer, or an electronic
densitometer), procedures, and details underlying the interpretation of
test data and the selection of numerical limits.
The ASTM standards are available from the American Society for
Testing and Materials (ASTM), 100 Barr Harbor Drive, Post Office Box
C700, West Conshohocken, PA 19428-2959. See https://www.astm.org/.
The EPA decided not to include certain other VCS; these methods are
impractical as alternatives because of the lack of equivalency,
documentation, validation date, and other important technical and
policy considerations. The search and review results have been
documented and are in the memoranda titled Voluntary Consensus Standard
Results for Surface Coating of Metal Cans, August 16, 2018, and
Voluntary Consensus Standard Results for Surface Coating of Metal Coil,
August 16, 2018, in the Surface Coating of Metal Cans Docket and the
Surface Coating of Metal Coil Docket, respectively.
Under 40 CFR 63.7(f) and 40 CFR 63.8(f) of subpart A of the General
Provisions, a source may apply to the EPA for permission to use
alternative test methods or alternative monitoring requirements in
place of any required testing methods, performance specifications, or
procedures in the final rule or any amendments.
K. Executive Order 12898: Federal Actions To Address Environmental
Justice in Minority Populations and Low-Income Populations
The EPA believes that this action does not have disproportionately
high and adverse human health or environmental effects on minority
populations, low-income populations, and/or indigenous peoples, as
specified in Executive Order 12898 (59 FR 7629, February 16, 1994)
because it does not significantly affect the level of protection
provided to human health or the environment. The documentation for this
decision is contained in section IV of this preamble and the technical
reports titled Risk and Technology Review--Analysis of Demographic
Factors for Populations Living Near Surface Coating of Metal Cans
Source Category Operations, May 2018, and Risk and Technology Review--
Analysis of Demographic Factors for Populations Living Near Surface
Coating of Metal Coil Source Category Operations, May 2018, which are
available in the Surface Coating of Metal Cans and Surface Coating of
Metal Coil Dockets, respectively.
L. Congressional Review Act (CRA)
This action is subject to the CRA, and the EPA will submit a rule
report to each House of the Congress and to the Comptroller General of
the United States. This action is not a ``major rule'' as defined by 5
U.S.C. 804(2)
List of Subjects in 40 CFR Part 63
Environmental protection, Administrative practice and procedures,
Air pollution control, Hazardous substances, Incorporation by
reference, Surface Coating of Metal Cans, Surface Coating of Metal
Coil, Reporting and recordkeeping requirements, Appendix A.
Dated: December 20, 2019.
Andrew R. Wheeler,
Administrator.
For the reasons stated in the preamble, the EPA amends 40 CFR part
63 as follows:
PART 63--NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS
FOR SOURCE CATEGORIES
0
1. The authority citation for part 63 continues to read as follows:
Authority: 42 U.S.C. 7401 et seq.
Subpart A--General Provisions
0
2. Section 63.14 is amended by revising paragraphs (h)(13), (21), (26),
(29), (30), (78) and (79) to read as follows:
Sec. 63.14 Incorporations by reference.
* * * * *
(h) * * *
(13) ASTM D1475-13, Standard Test Method for Density of Liquid
Coatings, Inks, and Related Products, approved November 1, 2013, IBR
approved for Sec. Sec. 63.3521(c), 63.3531(c), 63.4141(b) and (c),
63.4741(b) and (c), 63.4751(c), 63.4941(b) and (c), and 63.5160(c).
* * * * *
(21) ASTM D2111-10 (Reapproved 2015), Standard Test Methods for
Specific Gravity and Density of Halogenated Organic Solvents and Their
Admixtures, approved June 1, 2015, IBR approved for Sec. Sec.
63.3531(c), 63.4141(b) and (c), 63.4741(a), and 63.5160(c).
* * * * *
(26) ASTM D2369-10 (Reapproved 2015)\e\, Standard Test Method for
Volatile Content of Coatings, approved June 1, 2015, IBR approved for
Sec. Sec. 63.3521(a), 63.3541(i), 63.4141(a) and (b), 63.4161(h),
63.4321(e), 63.4341(e), 63.4351(d), 63.4741(a), 63.4941(a) and (b),
63.4961(j), and 63.5160(b).
* * * * *
[[Page 10847]]
(29) ASTM D2697-86 (Reapproved 1998), Standard Test Method for
Volume Nonvolatile Matter in Clear or Pigmented Coatings, IBR approved
for Sec. Sec. 63.3161(f), 63.3941(b), 63.4141(b), 63.4741(b), and
63.4941(b).
(30) ASTM D2697-03 (Reapproved 2014), Standard Test Method for
Volume Nonvolatile Matter in Clear or Pigmented Coatings, approved July
1, 2014, IBR approved for Sec. Sec. 63.3521(b), 63.4141(b), 63.4741(a)
and (b), 63.4941(b), and 63.5160(c).
* * * * *
(78) ASTM D6093-97 (Reapproved 2003), Standard Test Method for
Percent Volume Nonvolatile Matter in Clear or Pigmented Coatings Using
a Helium Gas Pycnometer, IBR approved for Sec. Sec. 63.3161 and
63.3941.
(79) ASTM D6093-97 (Reapproved 2016), Standard Test Method for
Percent Volume Nonvolatile Matter in Clear or Pigmented Coatings Using
a Helium Gas Pycnometer, Approved December 1, 2016, IBR approved for
Sec. Sec. 63.3521(b), 63.4141(b), 63.4741(a) and (b), 63.4941(b), and
63.5160(c).
* * * * *
Subpart KKKK--National Emission Standards for Hazardous Air
Pollutants: Surface Coating of Metal Cans
0
3. Section 63.3481 is amended by revising paragraph (c)(5) to read as
follows:
Sec. 63.3481 Am I subject to this subpart?
* * * * *
(c) * * *
(5) Surface coating of metal pails, buckets, and drums. Subpart
MMMM of this part covers surface coating of all miscellaneous metal
parts and products not explicitly covered by another subpart.
0
4. Section 63.3492 is amended by revising paragraph (b) to read as
follows:
Sec. 63.3492 What operating limits must I meet?
* * * * *
(b) For any controlled coating operation(s) on which you use the
emission rate with add-on controls option or the control efficiency/
outlet concentration option, except those for which you use a solvent
recovery system and conduct a liquid-liquid material balance according
to Sec. 63.3541(i), you must meet the operating limits specified in
Table 4 to this subpart. Those operating limits apply to the emission
capture and control systems for the coating operation(s) used for
purposes of complying with this subpart. You must establish the
operating limits during the performance tests required in Sec. 63.3540
or Sec. 63.3550 according to the requirements in Sec. 63.3546 or
Sec. 63.3556. You must meet the operating limits established during
the most recent performance tests required in Sec. 63.3540 or Sec.
63.3550 at all times after they have been established during the
performance test.
* * * * *
0
5. Section 63.3500 is amended by revising paragraphs (a)(1), (b), and
(c) to read as follows:
Sec. 63.3500 What are my general requirements for complying with this
subpart?
(a) * * *
(1) Any coating operation(s) for which you use the compliant
material option or the emission rate without add-on controls option, as
specified in Sec. 63.3491(a) and (b), must be in compliance with the
applicable emission limit in Sec. 63.3490 at all times.
* * * * *
(b) Before August 24, 2020, you must always operate and maintain
your affected source, including all air pollution control and
monitoring equipment you use for purposes of complying with this
subpart, according to the provisions in Sec. 63.6(e)(1)(i). On and
after August 24, 2020, at all times, the owner or operator must operate
and maintain any affected source, including associated air pollution
control equipment and monitoring equipment, in a manner consistent with
safety and good air pollution control practices for minimizing
emissions. The general duty to minimize emissions does not require the
owner or operator to make any further efforts to reduce emissions if
levels required by the applicable standard have been achieved.
Determination of whether a source is operating in compliance with
operation and maintenance requirements will be based on information
available to the Administrator that may include, but is not limited to,
monitoring results, review of operation and maintenance procedures,
review of operation and maintenance records, and inspection of the
affected source.
(c) Before August 24, 2020, if your affected source uses an
emission capture system and add-on control device for purposes of
complying with this subpart, you must develop a written startup,
shutdown, and malfunction plan (SSMP) according to the provisions in
Sec. 63.6(e)(3). The plan must address startup, shutdown, and
corrective actions in the event of a malfunction of the emission
capture system or the add-on control device. The plan must also address
any coating operation equipment that may cause increased emissions or
that would affect capture efficiency if the process equipment
malfunctions, such as conveyors that move parts among enclosures. On
and after August 24, 2020, the SSMP is not required.
0
6. Section 63.3511 is amended by:
0
a. Revising paragraphs (a)(4), (a)(5) introductory text, (a)(5)(i), and
(a)(5)(iv);
0
b. Adding paragraph (a)(5)(v);
0
c. Revising paragraph (a)(6) introductory text and (a)(6)(iii);
0
d. Adding paragraph (a)(6)(iv);
0
e. Revising paragraphs (a)(7) introductory text, (a)(7)(iii),
(a)(7)(vi) through (viii), (a)(7)(x), and (a)(7)(xiii) and (xiv);
0
f. Adding paragraph (a)(7)(xv);
0
g. Revising paragraphs (a)(8) introductory text, (a)(8)(i), (a)(8)(iv)
through (vi), (a)(8)(viii), and (a)(8)(xi) and (xii);
0
f. Adding paragraph (a)(8)(xiii);
0
g. Revising paragraph (c) introductory text; and
0
h. Adding paragraphs (d) through (h).
The revisions and additions read as follows:
Sec. 63.3511 What reports must I submit?
(a) * * *
(4) No deviations. If there were no deviations from the emission
limits, operating limits, or work practice standards in Sec. Sec.
63.3490, 63.3492, and 63.3493 that apply to you, the semiannual
compliance report must include a statement that there were no
deviations from the emission limitations during the reporting period.
If you used the emission rate with add-on controls option or the
control efficiency/outlet concentration option and there were no
periods during which the continuous parameter monitoring systems (CPMS)
were out of control as specified in Sec. 63.8(c)(7), the semiannual
compliance report must include a statement that there were no periods
during which the CPMS were out of control during the reporting period.
(5) Deviations: Compliant material option. If you used the
compliant material option and there was a deviation from the applicable
emission limit in Sec. 63.3490, the semiannual compliance report must
contain the information in paragraphs (a)(5)(i) through (v) of this
section.
(i) Identification of each coating used that deviated from the
emission limit, each thinner used that contained organic HAP, and the
date, time, and duration each was used.
* * * * *
[[Page 10848]]
(iv) Before August 24, 2020, a statement of the cause of each
deviation. On and after August 24, 2020, a statement of the cause of
each deviation (including unknown cause, if applicable).
(v) On and after August 24, 2020, the number of deviations and, for
each deviation, a list of the affected source or equipment, an estimate
of the quantity of each regulated pollutant emitted over any applicable
emission limit in Sec. 63.3490, a description of the method used to
estimate the emissions, and the actions you took to minimize emissions
in accordance with Sec. 63.3500(b).
(6) Deviations: Emission rate without add-on controls option. If
you used the emission rate without add-on controls option and there was
a deviation from the applicable emission limit in Sec. 63.3490, the
semiannual compliance report must contain the information in paragraphs
(a)(6)(i) through (iv) of this section.
* * * * *
(iii) Before August 24, 2020, a statement of the cause of each
deviation. On and after August 24, 2020, a statement of the cause of
each deviation (including unknown cause, if applicable).
(iv) On and after August 24, 2020, the number of deviations, date,
time, duration, a list of the affected source or equipment, an estimate
of the quantity of each regulated pollutant emitted over any applicable
emission limit in Sec. 63.3490, a description of the method used to
estimate the emissions, and the actions you took to minimize emissions
in accordance with Sec. 63.3500(b).
(7) Deviations: Emission rate with add-on controls option. If you
used the emission rate with add-on controls option and there was a
deviation from the applicable emission limit in Sec. 63.3490 or the
applicable operating limit(s) in Table 4 to this subpart (including any
periods when emissions bypassed the add-on control device and were
diverted to the atmosphere), before August 24, 2020, the semiannual
compliance report must contain the information in paragraphs (a)(7)(i)
through (xiv) of this section. That includes periods of startup,
shutdown, and malfunction during which deviations occurred. On and
after August 24, 2020, the semiannual compliance report must contain
the information in paragraphs (a)(7)(i) through (xii), (a)(7)(xiv), and
(a)(7)(xv) of this section. If you use the emission rate with add-on
controls option and there was a deviation from the applicable work
practice standards in Sec. 63.3493(b), the semiannual compliance
report must contain the information in paragraph (a)(7)(xiii) of this
section.
* * * * *
(iii) The date and time that each malfunction of the capture system
or add-on control devices started and stopped.
* * * * *
(vi) Before August 24, 2020, the date and time that each CPMS was
inoperative, except for zero (low-level) and high-level checks. On and
after August 24, 2020, the number of instances that the CPMS was
inoperative, and for each instance, except for zero (low-level) and
high-level checks, the date, time, and duration that the CPMS was
inoperative; the cause (including unknown cause) for the CPMS being
inoperative; and the actions you took to minimize emissions in
accordance with Sec. 63.3500(b).
(vii) Before August 24, 2020, the date, time, and duration that
each CPMS was out of control, including the information in Sec.
63.8(c)(8). On and after August 24, 2020, the number of instances that
the CPMS was out of control as specified in Sec. 63.8(c)(7) and, for
each instance, the date, time, and duration that the CPMS was out-of-
control; the cause (including unknown cause) for the CPMS being out-of-
control; and descriptions of corrective actions taken.
(viii) Before August 24, 2020, the date and time period of each
deviation from an operating limit in Table 4 to this subpart; date and
time period of any bypass of the add-on control device; and whether
each deviation occurred during a period of startup, shutdown, or
malfunction or during another period. On and after August 24, 2020, the
number of deviations from an operating limit in Table 4 to this subpart
and, for each deviation, the date, time, and duration of each
deviation; the date, time, and duration of any bypass of the add-on
control device.
* * * * *
(x) Before August 24, 2020, a breakdown of the total duration of
the deviations from the operating limits in Table 4 to this subpart and
bypasses of the add-on control device during the semiannual reporting
period into those that were due to startup, shutdown, control equipment
problems, process problems, other known causes, and other unknown
causes. On and after August 24, 2020, a breakdown of the total duration
of the deviations from the operating limits in Table 4 to this subpart
and bypasses of the add-on control device during the semiannual
reporting period into those that were due to control equipment
problems, process problems, other known causes, and other unknown
causes.
* * * * *
(xiii) Before August 24, 2020, for each deviation from the work
practice standards, a description of the deviation; the date, and time
period of the deviation; and the actions you took to correct the
deviation. On and after August 24, 2020, for deviations from the work
practice standards, the number of deviations, and, for each deviation,
the information in paragraphs (a)(7)(xiii)(A) and (B) of this section:
(A) A description of the deviation; the date, time, and duration of
the deviation; and the actions you took to minimize emissions in
accordance with Sec. 63.3500(b).
(B) The description required in paragraph (a)(7)(xiii)(A) of this
section must include a list of the affected sources or equipment for
which a deviation occurred and the cause of the deviation (including
unknown cause, if applicable.
(xiv) Before August 24, 2020, a statement of the cause of each
deviation. On and after August 24, 2020, for deviations from an
emission limit in Sec. 63.3490 or an operating limit in Table 4 to
this subpart, a statement of the cause of each deviation (including
unknown cause, if applicable) and the actions you took to minimize
emissions in accordance with Sec. 63.3500(b).
(xv) On and after August 24, 2020, for each deviation from an
emission limit in Sec. 63.3490 or operating limit in Table 4 to this
subpart, a list of the affected sources or equipment for which a
deviation occurred, an estimate of the quantity of each regulated
pollutant emitted over any emission limit in Sec. 63.3490 or operating
limit in Table 4 to this subpart, and a description of the method used
to estimate the emissions.
(8) Deviations: control efficiency/outlet concentration option. If
you used the control efficiency/outlet concentration option, and there
was a deviation from the applicable emission limit in Sec. 63.3490 or
the applicable operating limit(s) in Table 4 to this subpart (including
any periods when emissions bypassed the add-on control device and were
diverted to the atmosphere), before August 24, 2020, the semiannual
compliance report must contain the information in paragraphs (a)(8)(i)
through (xii) of this section. This includes periods of startup,
shutdown, and malfunction during which deviations occurred. On and
after August 24, 2020, the semiannual compliance report must specify
the number of deviations during the compliance period and contain the
[[Page 10849]]
information in paragraphs (a)(8)(i) through (x), (xii), and (xiii) of
this section. If you use the control efficiency/outlet concentration
option and there was a deviation from the applicable work practice
standards in Sec. 63.3493(b), the semiannual compliance report must
contain the information in paragraph (a)(8)(xi) of this section.
(i) The date and time that each malfunction of the capture system
or add-on control devices started and stopped.
* * * * *
(iv) Before August 24, 2020, the date and time that each CPMS was
inoperative, except for zero (low-level) and high-level checks. On and
after August 24, 2020, for each instance that the CPMS was inoperative,
except for zero (low-level) and high-level checks, the date, time, and
duration that the CPMS was inoperative; the cause (including unknown
cause) for the CPMS being inoperative; and the actions you took to
minimize emissions in accordance with Sec. 63.3500(b).
(v) For each instance that the CPMS was out of control as specified
in Sec. 63.8(c)(7), the date, time, and duration that the CPMS was out
of control; the cause (including unknown cause) for the CPMS being out
of control; and the actions you took to minimize emissions in
accordance with Sec. 63.3500(b).
(vi) Before August 24, 2020, the date and time period of each
deviation from an operating limit in Table 4 to this subpart; date and
time of any bypass of the add-on control device; and whether each
deviation occurred during a period of startup, shutdown, or malfunction
or during another period. On and after August 24, 2020, the date, time,
and duration of each deviation from an operating limit in Table 4 to
this subpart; and the date, time, and duration of any bypass of the
add-on control device.
* * * * *
(viii) Before August 24, 2020, a breakdown of the total duration of
the deviations from the operating limits in Table 4 to this subpart and
bypasses of the add-on control device during the semiannual reporting
period into those that were due to startup, shutdown, control equipment
problems, process problems, other known causes, and other unknown
causes. On and after August 24, 2020, a breakdown of the total duration
of the deviations from the operating limits in Table 4 to this subpart
and bypasses of the add-on control device during the semiannual
reporting period into those that were due to control equipment
problems, process problems, other known causes, and other unknown
causes.
* * * * *
(xi) Before August 24, 2020, for each deviation from the work
practice standards, a description of the deviation; the date and time
period of the deviation; and the actions you took to correct the
deviation. On and after August 24, 2020, for deviations from the work
practice standards in Sec. 63.3493(b), the number of deviations, and,
for each deviation, the information in paragraphs (a)(8)(xiii)(A) and
(B) of this section:
(A) A description of the deviation; the date, time, and duration of
the deviation; and the actions you took to minimize emissions in
accordance with Sec. 63.3500(b).
(B) The description required in paragraph (a)(8)(xi)(A) of this
section must include a list of the affected sources or equipment for
which a deviation occurred and the cause of the deviation (including
unknown cause, if applicable).
(xii) Before August 24, 2020, a statement of the cause of each
deviation. On and after August 24, 2020, for deviations from an
emission limit in Sec. 63.3490 or operating limit in Table 4 to this
subpart, a statement of the cause of each deviation (including unknown
cause, if applicable).
(xiii) On and after August 24, 2020, for each deviation from an
emission limit in Sec. 63.3490 or operating limit in Table 4 to this
subpart, a list of the affected sources or equipment for which a
deviation occurred, an estimate of the quantity of each regulated
pollutant emitted over any emission limit in Sec. 63.3490, and a
description of the method used to estimate the emissions.
* * * * *
(c) Startup, shutdown, malfunction reports. Before August 24, 2020,
if you used the emission rate with add-on controls option or the
control efficiency/outlet concentration option and you had a startup,
shutdown, or malfunction during the semiannual reporting period, you
must submit the reports specified in paragraphs (c)(1) and (2) of this
section. On and after August 24, 2020, the reports specified in
paragraphs (c)(1) and (2) of this section are not required.
* * * * *
(d) On and after August 24, 2020, you must submit the results of
the performance test required in Sec. Sec. 63.3540 and 63.3550
following the procedure specified in paragraphs (d)(1) through (3) of
this section.
(1) For data collected using test methods supported by the EPA's
Electronic Reporting Tool (ERT) as listed on the EPA's ERT website
(https://www.epa.gov/electronic-reporting-air-emissions/electronic-reporting-tool-ert) at the time of the test, you must submit the
results of the performance test to the EPA via the Compliance and
Emissions Data Reporting Interface (CEDRI). The CEDRI interface can be
accessed through the EPA's Central Data Exchange (CDX) (https://cdx.epa.gov/). Performance test data must be submitted in a file format
generated through the use of the EPA's ERT or an alternate electronic
file format consistent with the extensible markup language (XML) schema
listed on the EPA's ERT website.
(2) For data collected using test methods that are not supported by
the EPA's ERT as listed on the EPA's ERT website at the time of the
test, you must submit the results of the performance test in portable
document format (PDF) using the attachment module of the ERT.
(3) If you claim that some of the performance test information
being submitted under paragraph (d)(1) of this section is confidential
business information (CBI), you must submit a complete file generated
through the use of the EPA's ERT or an alternate electronic file
consistent with the XML schema listed on the EPA's ERT website,
including information claimed to be CBI, on a compact disc, flash
drive, or other commonly used electronic storage medium to the EPA. The
electronic medium must be clearly marked as CBI and mailed to U.S. EPA/
OAPQS/CORE CBI Office, Attention: Group Leader, Measurement Policy
Group, MD C404-02, 4930 Old Page Rd., Durham, NC 27703. The same ERT or
alternate file with the CBI omitted must be submitted to the EPA via
the EPA's CDX as described in paragraph (c)(1) of this section.
(e) On and after August 24, 2020, the owner or operator shall
submit the initial notifications required in Sec. 63.9(b) and the
notification of compliance status required in Sec. Sec. 63.9(h) and
63.3510(c) to the EPA via the CEDRI. The CEDRI interface can be
accessed through the EPA's CDX (https://cdx.epa.gov). The owner or
operator must upload to CEDRI an electronic copy of each applicable
notification in PDF. The applicable notification must be submitted by
the deadline specified in this subpart, regardless of the method in
which the reports are submitted. Owners or operators who claim that
some of the information required to be submitted via CEDRI is CBI shall
submit a complete report generated using the appropriate form in CEDRI
or an alternate electronic file consistent with the XML schema listed
on the EPA's
[[Page 10850]]
CEDRI website, including information claimed to be CBI, on a compact
disc, flash drive, or other commonly used electronic storage medium to
the EPA. The electronic medium shall be clearly marked as CBI and
mailed to U.S. EPA/OAQPS/CORE CBI Office, Attention: Group Leader,
Measurement Policy Group, MD C404-02, 4930 Old Page Rd., Durham, NC
27703. The same file with the CBI omitted shall be submitted to the EPA
via the EPA's CDX as described earlier in this paragraph.
(f) On and after March 25, 2021, or once the reporting template has
been available on the CEDRI website for 1 year, whichever date is
later, the owner or operator shall submit the semiannual compliance
report required in paragraph (a) of this section to the EPA via the
CEDRI. The CEDRI interface can be accessed through the EPA's CDX
(https://cdx.epa.gov). The owner or operator must use the appropriate
electronic template on the CEDRI website for this subpart (https://www.epa.gov/electronic-reporting-air-emissions/compliance-and-emissions-data-reporting-interface-cedri). The date report templates
become available will be listed on the CEDRI website. If the reporting
form for the semiannual compliance report specific to this subpart is
not available in CEDRI at the time that the report is due, you must
submit the report to the Administrator at the appropriate addresses
listed in Sec. 63.13. Once the form has been available in CEDRI for 1
year, you must begin submitting all subsequent reports via CEDRI. The
reports must be submitted by the deadlines specified in this subpart,
regardless of the method in which the reports are submitted. Owners or
operators who claim that some of the information required to be
submitted via CEDRI is CBI shall submit a complete report generated
using the appropriate form in CEDRI, including information claimed to
be CBI, on a compact disc, flash drive, or other commonly used
electronic storage medium to the EPA. The electronic medium shall be
clearly marked as CBI and mailed to U.S. EPA/OAQPS/CORE CBI Office,
Attention: Group Leader, Measurement Policy Group, MD C404-02, 4930 Old
Page Rd., Durham, NC 27703. The same file with the CBI omitted shall be
submitted to the EPA via the EPA's CDX as described earlier in this
paragraph.
(g) If you are required to electronically submit a report through
the CEDRI in the EPA's CDX, you may assert a claim of the EPA system
outage for failure to timely comply with the reporting requirement. To
assert a claim of the EPA system outage, you must meet the requirements
outlined in paragraphs (g)(1) through (7) of this section.
(1) You must have been or will be precluded from accessing CEDRI
and submitting a required report within the time prescribed due to an
outage of either the EPA's CEDRI or CDX systems.
(2) The outage must have occurred within the period of time
beginning five business days prior to the date that the submission is
due.
(3) The outage may be planned or unplanned.
(4) You must submit notification to the Administrator in writing as
soon as possible following the date you first knew, or through due
diligence should have known, that the event may cause or caused a delay
in reporting.
(5) You must provide to the Administrator a written description
identifying:
(i) The date(s) and time(s) when CDX or CEDRI was accessed and the
system was unavailable;
(ii) A rationale for attributing the delay in reporting beyond the
regulatory deadline to the EPA system outage;
(iii) Measures taken or to be taken to minimize the delay in
reporting; and
(iv) The date by which you propose to report, or if you have
already met the reporting requirement at the time of the notification,
the date you reported.
(6) The decision to accept the claim of the EPA system outage and
allow an extension to the reporting deadline is solely within the
discretion of the Administrator.
(7) In any circumstance, the report must be submitted
electronically as soon as possible after the outage is resolved.
(h) If you are required to electronically submit a report through
CEDRI in the EPA's CDX, you may assert a claim of force majeure for
failure to timely comply with the reporting requirement. To assert a
claim of force majeure, you must meet the requirements outlined in
paragraphs (h)(1) through (5) of this section.
(1) You may submit a claim if a force majeure event is about to
occur, occurs, or has occurred or there are lingering effects from such
an event within the period of time beginning five business days prior
to the date the submission is due. For the purposes of this section, a
force majeure event is defined as an event that will be or has been
caused by circumstances beyond the control of the affected facility,
its contractors, or any entity controlled by the affected facility that
prevents you from complying with the requirement to submit a report
electronically within the time period prescribed. Examples of such
events are acts of nature (e.g., hurricanes, earthquakes, or floods),
acts of war or terrorism, or equipment failure or safety hazard beyond
the control of the affected facility (e.g., large scale power outage).
(2) You must submit notification to the Administrator in writing as
soon as possible following the date you first knew, or through due
diligence should have known, that the event may cause or has caused a
delay in reporting.
(3) You must provide to the Administrator:
(i) A written description of the force majeure event;
(ii) A rationale for attributing the delay in reporting beyond the
regulatory deadline to the force majeure event;
(iii) Measures taken or to be taken to minimize the delay in
reporting; and
(iv) The date by which you propose to report, or if you have
already met the reporting requirement at the time of the notification,
the date you reported.
(4) The decision to accept the claim of force majeure and allow an
extension to the reporting deadline is solely within the discretion of
the Administrator.
(5) In any circumstance, the reporting must occur as soon as
possible after the force majeure event occurs.
0
7. Section 63.3512 is amended by revising paragraphs (i), (j)
introductory text, and (j)(1) and (2) to read as follows:
Sec. 63.3512 What records must I keep?
* * * * *
(i) Before August 24, 2020, a record of the date, time, and
duration of each deviation. On and after August 24, 2020, for each
deviation from an emission limitation reported under Sec.
63.3511(a)(5) through (8), a record of the information specified in
paragraphs (i)(1) through (4) of this section, as applicable.
(1) The date, time, and duration of the deviation, as reported
under Sec. 63.3511(a)(5) through (8).
(2) A list of the affected sources or equipment for which the
deviation occurred and the cause of the deviation, as reported under
Sec. 63.3511(a)(5) through (8).
(3) An estimate of the quantity of each regulated pollutant emitted
over any applicable emission limit in Sec. 63.3490 or any applicable
operating limit in Table 4 to this subpart, and a description of the
method used to calculate the estimate, as reported under Sec.
63.3511(a)(5) through (8).
(4) A record of actions taken to minimize emissions in accordance
with Sec. 63.3500(b) and any corrective actions taken to return the
affected unit to its normal or usual manner of operation.
[[Page 10851]]
(j) If you use the emission rate with add-on controls option or the
control efficiency/outlet concentration option, you must also keep the
records specified in paragraphs (j)(1) through (8) of this section.
(1) Before August 24, 2020, for each deviation, a record of whether
the deviation occurred during a period of startup, shutdown, or
malfunction. On and after August 24, 2020, a record of whether the
deviation occurred during a period of startup, shutdown, or malfunction
is not required.
(2) Before August 24, 2020, the records in Sec. 63.6(e)(3)(iii)
through (v) related to startup, shutdown, and malfunction. On and after
August 24, 2020, the records in Sec. 63.6(e)(3)(iii) through (v)
related to startup, shutdown, and malfunction are not required.
* * * * *
0
8. Section 63.3513 is amended by revising paragraph (a) to read as
follows:
Sec. 63.3513 In what form and for how long must I keep my records?
(a) Your records must be kept in a form suitable and readily
available for expeditious review, according to Sec. 63.10(b)(1). Where
appropriate, the records may be maintained as electronic spreadsheets
or as a database. On and after August 24, 2020, any records required to
be maintained by this subpart that are in reports that were submitted
electronically via the EPA's CEDRI may be maintained in electronic
format. This ability to maintain electronic copies does not affect the
requirement for facilities to make records, data, and reports available
upon request to a delegated air agency or the EPA as part of an on-site
compliance evaluation.
* * * * *
0
9. Section 63.3521 is amended by revising paragraphs (a)(1)(i), (a)(2),
(a)(4), (b)(1), and (c) to read as follows:
Sec. 63.3521 How do I demonstrate initial compliance with the
emission limitations?
* * * * *
(a) * * *
(1) * * *
(i) Count each organic HAP in Table 8 to this subpart that is
measured to be present at 0.1 percent by mass or more and at 1.0
percent by mass or more for other compounds. For example, if toluene
(not listed in Table 8 to this subpart) is measured to be 0.5 percent
of the material by mass, you do not have to count it. Express the mass
fraction of each organic HAP you count as a value truncated to four
places after the decimal point (e.g., 0.3791).
* * * * *
(2) Method 24 (appendix A to 40 CFR part 60). For coatings, you may
use Method 24 to determine the mass fraction of nonaqueous volatile
matter and use that value as a substitute for mass fraction of organic
HAP. As an alternative to using Method 24, you may use ASTM D2369-10
(2015), ``Test Method for Volatile Content of Coatings'' (incorporated
by reference, see Sec. 63.14).
* * * * *
(4) Information from the supplier or manufacturer of the material.
You may rely on information other than that generated by the test
methods specified in paragraphs (a)(1) through (3) of this section,
such as manufacturer's formulation data, if it represents each organic
HAP in Table 8 to this subpart that is present at 0.1 percent by mass
or more and at 1.0 percent by mass or more for other compounds. For
example, if toluene (not listed in Table 8 to this subpart) is 0.5
percent of the material by mass, you do not have to count it. If there
is a disagreement between such information and results of a test
conducted according to paragraphs (a)(1) through (3) of this section,
then the test method results will take precedence unless, after
consultation, a regulated source can demonstrate to the satisfaction of
the enforcement agency that the formulation data are correct.
* * * * *
(b) * * *
(1) ASTM Method D2697-03 (2014) or D6093-97 (2016). You may use
ASTM D2697-03 (2014), ``Standard Test Method for Volume Nonvolatile
Matter in Clear or Pigmented Coatings,'' (incorporated by reference,
see Sec. 63.14) or ASTM D6093-97 (2016), ``Standard Test Method for
Percent Volume Nonvolatile Matter in Clear or Pigmented Coatings Using
a Helium Gas Pycnometer'' (incorporated by reference, see Sec. 63.14),
to determine the volume fraction of coating solids for each coating.
Divide the nonvolatile volume percent obtained with the methods by 100
to calculate volume fraction of coating solids. If these values cannot
be determined using these methods, the owner/operator may submit an
alternative technique for determining the values for approval by the
Administrator.
* * * * *
(c) Determine the density of each coating. Determine the density of
each coating used during the compliance period from test results using
ASTM Method D1475-13 ``Standard Test Method for Density of Liquid
Coatings, Inks, and Related Products'' (incorporated by reference, see
Sec. 63.14) or information from the supplier or manufacturer of the
material. If there is disagreement between ASTM Method D1475-13 test
results and the supplier's or manufacturer's information, the test
results will take precedence.
* * * * *
0
10. Section 63.3531 is amended by revising paragraph (c) to read as
follows:
Sec. 63.3531 How do I demonstrate initial compliance with the
emission limitations?
* * * * *
(c) Determine the density of each material. Determine the density
of each coating and thinner used during each month from test results
using ASTM D1475-13 or ASTM D2111-10 (2015) (both incorporated by
reference, see Sec. 63.14), information from the supplier or
manufacturer of the material, or reference sources providing density or
specific gravity data for pure materials. If there is disagreement
between ASTM D1475-13 or ASTM D2111-10 (2015) test results and such
other information sources, the test results will take precedence.
* * * * *
0
11. Section 63.3540 is amended by revising the section heading and
paragraphs (a)(1), (a)(4), and (b)(1) to read as follows:
Sec. 63.3540 By what date must I conduct performance tests and
initial compliance demonstrations?
(a) * * *
(1) All emission capture systems, add-on control devices, and CPMS
must be installed and operating no later than the applicable compliance
date specified in Sec. 63.3483. Except for solvent recovery systems
for which you conduct liquid-liquid material balances according to
Sec. 63.3541(i), you must conduct according to the schedule in
paragraphs (a)(1)(i) and (ii) of this section initial and periodic
performance tests of each capture system and add-on control device
according to the procedures in Sec. Sec. 63.3543, 63.3544, and 63.3545
and establish the operating limits required by Sec. 63.3492. For a
solvent recovery system for which you conduct liquid-liquid material
balances according to Sec. 63.3541(i), you must initiate the first
material balance no later than the applicable compliance date specified
in Sec. 63.3483.
(i) You must conduct the initial performance test and establish the
operating limits required by Sec. 63.3492 no later than 180 days after
the applicable compliance date specified in Sec. 63.3483.
(ii) If you are not required to complete periodic performance tests
as a requirement of renewing your facility's
[[Page 10852]]
operating permit under 40 CFR part 70 or 40 CFR part 71, you must
conduct the first periodic performance test before March 25, 2023,
unless you already have conducted a performance test on or after March
25, 2018. Thereafter you must conduct a performance test no later than
5 years following the previous performance test. Operating limits must
be confirmed or reestablished during each performance test. If you are
required to complete periodic performance tests as a requirement of
renewing your facility's operating permit under 40 CFR part 70 or 40
CFR part 71, you must conduct the periodic testing in accordance with
the terms and schedule required by your permit conditions.
* * * * *
(4) For the initial compliance demonstration, you do not need to
comply with the operating limits for the emission capture system and
add-on control device required by Sec. 63.3492 until after you have
completed the initial performance tests specified in paragraph (a)(1)
of this section. Instead, you must maintain a log detailing the
operation and maintenance of the emission capture system, add-on
control device, and continuous parameter monitors during the period
between the compliance date and the performance test. You must begin
complying with the operating limits established based on the initial
performance tests specified in paragraph (a)(1) of this section for
your affected source on the date you complete the performance tests.
The requirements in this paragraph (a)(4) do not apply to solvent
recovery systems for which you conduct liquid-liquid material balances
according to the requirements in Sec. 63.3541(i).
(b) * * *
(1) All emission capture systems, add-on control devices, and CPMS
must be installed and operating no later than the applicable compliance
date specified in Sec. 63.3483. Except for solvent recovery systems
for which you conduct liquid-liquid material balances according to
Sec. 63.3541(i), you must conduct according to the schedule in
paragraphs (b)(1)(i) and (ii) of this section initial and periodic
performance tests of each capture system and add-on control device
according to the procedures in Sec. Sec. 63.3543, 63.3544, and 63.3545
and establish the operating limits required by Sec. 63.3492. For a
solvent recovery system for which you conduct liquid-liquid material
balances according to Sec. 63.3541(i), you must initiate the first
material balance no later than the compliance date specified in Sec.
63.3483.
(i) You must conduct the initial performance test and establish the
operating limits required by Sec. 63.3492 no later than 180 days after
the applicable compliance date specified in Sec. 63.3483.
(ii) If you are not required to complete periodic performance tests
as a requirement of renewing your facility's operating permit under 40
CFR part 70 or 40 CFR part 71, you must conduct the first periodic
performance test before March 25, 2023, unless you already have
conducted a performance test on or after March 25, 2018. Thereafter you
must conduct a performance test no later than 5 years following the
previous performance test. Operating limits must be confirmed or
reestablished during each performance test. If you are required to
complete periodic performance tests as a requirement of renewing your
facility's operating permit under 40 CFR part 70 or 40 CFR part 71, you
must conduct the periodic testing in accordance with the terms and
schedule required by your permit conditions.
* * * * *
0
12. Section 63.3541 is amended by revising paragraphs (h) introductory
text and (i)(3) to read as follows:
Sec. 63.3541 How do I demonstrate initial compliance?
* * * * *
(h) Calculate the organic HAP emission reduction for each
controlled coating operation not using liquid-liquid material balances.
For each controlled coating operation using an emission capture system
and add-on control device, other than a solvent recovery system for
which you conduct liquid-liquid material balances, calculate the
organic HAP emission reduction, using Equation 1 of this section. The
calculation applies the emission capture system efficiency and add-on
control device efficiency to the mass of organic HAP contained in the
coatings and thinners that are used in the coating operation served by
the emission capture system and add-on control device during each
month. For any period of time a deviation specified in Sec. 63.3542(c)
or (d) occurs in the controlled coating operation, you must assume zero
efficiency for the emission capture system and add-on control device,
unless you have other data indicating the actual efficiency of the
emission capture system and add-on control device, and the use of these
data has been approved by the Administrator. Equation 1 of this section
treats the materials used during such a deviation as if they were used
on an uncontrolled coating operation for the time period of the
deviation.
* * * * *
(i) * * *
(3) Determine the mass fraction of volatile organic matter for each
coating and thinner used in the coating operation controlled by the
solvent recovery system during the month, in kg volatile organic matter
per kg coating. You may determine the volatile organic matter mass
fraction using Method 24 of 40 CFR part 60, appendix A, ASTM D2369-10
(2015), ``Test Method for Volatile Content of Coatings'' (incorporated
by reference, see Sec. 63.14), or an EPA approved alternative method.
Alternatively, you may determine the volatile organic matter mass
fraction using information provided by the manufacturer or supplier of
the coating. In the event of any inconsistency between information
provided by the manufacturer or supplier and the results of Method 24
of 40 CFR part 60, appendix A, ASTM D2369-10 (2015) or an approved
alternative method, the test method results will take precedence
unless, after consultation, a regulated source can demonstrate to the
satisfaction of the enforcement agency that the formulation data are
correct.
* * * * *
0
13. Section 63.3542 is amended by revising paragraphs (f) and (h) to
read as follows:
Sec. 63.3542 How do I demonstrate continuous compliance with the
emission limitations?
* * * * *
(f) As part of each semiannual compliance report required in Sec.
63.3511, you must identify the coating operation(s) for which you used
the emission rate with add-on controls option. If there were no
deviations from the emission limits in Sec. 63.3490, the operating
limits in Sec. 63.3492, and the work practice standards in Sec.
63.3493, submit a statement that you were in compliance with the
emission limitations during the reporting period because the organic
HAP emission rate for each compliance period was less than or equal to
the applicable emission limit in Sec. 63.3490, and you achieved the
operating limits required by Sec. 63.3492 and the work practice
standards required by Sec. 63.3493 during each compliance period.
* * * * *
(h) Before August 24, 2020, consistent with Sec. Sec. 63.6(e) and
63.7(e)(1), deviations that occur during a period of startup, shutdown,
or malfunction of the emission capture system, add-on control device,
or coating operation that may
[[Page 10853]]
affect emission capture or control device efficiency are not violations
if you demonstrate to the Administrator's satisfaction that you were
operating in accordance with Sec. 63.6(e)(1). The Administrator will
determine whether deviations that occur during a period you identify as
a startup, shutdown, or malfunction are violations according to the
provisions in Sec. 63.6(e). On and after August 24, 2020, deviations
that occur due to malfunction of the emission capture system, add-on
control device, or coating operation that may affect emission capture
or control device efficiency are required to operate in accordance with
Sec. 63.3500(b). The Administrator will determine whether the
deviations are violations according to the provisions in Sec.
63.3500(b).
* * * * *
0
14. Section 63.3543 is amended by revising paragraphs (a) introductory
text and (a)(1) to read as follows:
Sec. 63.3543 What are the general requirements for performance tests?
(a) Before August 24, 2020, you must conduct each performance test
required by Sec. 63.3540 according to the requirements in Sec.
63.7(e)(1) and under the conditions in this section unless you obtain a
waiver of the performance test according to the provisions in Sec.
63.7(h). On and after August 24, 2020, you must conduct each
performance test required by Sec. 63.3540 according to the
requirements in this section unless you obtain a waiver of the
performance test according to the provisions in Sec. 63.7(h).
(1) Representative coating operation operating conditions. You must
conduct the performance test under representative operating conditions
for the coating operation. Operations during periods of startup,
shutdown, or nonoperation do not constitute representative conditions
for purposes of conducting a performance test. The owner or operator
may not conduct performance tests during periods of malfunction. You
must record the process information that is necessary to document
operating conditions during the test and explain why the conditions
represent normal operation. Upon request, you must make available to
the Administrator such records as may be necessary to determine the
conditions of performance tests.
* * * * *
0
15. Section 63.3544 is amended by revising the introductory text to
read as follows:
Sec. 63.3544 How do I determine the emission capture system
efficiency?
You must use the procedures and test methods in this section to
determine capture efficiency as part of each performance test required
by Sec. 63.3540.
* * * * *
0
16. Section 63.3545 is amended by revising the introductory text,
paragraph (b) introductory text, and paragraphs (b)(1) through (4) to
read as follows:
Sec. 63.3545 How do I determine the add-on control device emission
destruction or removal efficiency?
You must use the procedures and test methods in this section to
determine the add-on control device emission destruction or removal
efficiency as part of the performance tests required by Sec. 63.3540.
For each performance test, you must conduct three test runs as
specified in Sec. 63.7(e)(3) and each test run must last at least 1
hour.
* * * * *
(b) Measure total gaseous organic mass emissions as carbon at the
inlet and outlet of the add-on control device simultaneously using
either Method 25 or 25A of appendix A-7 to 40 CFR part 60 as specified
in paragraphs (b)(1) through (5) of this section. You must use the same
method for both the inlet and outlet measurements.
(1) Use Method 25 of appendix A-7 to 40 CFR part 60 if the add-on
control device is an oxidizer and you expect the total gaseous organic
concentration as carbon to be more than 50 ppm at the control device
outlet.
(2) Use Method 25A of appendix A-7 to 40 CFR part 60 if the add-on
control device is an oxidizer and you expect the total gaseous organic
concentration as carbon to be 50 ppm or less at the control device
outlet.
(3) Use Method 25A of appendix A-7 to 40 CFR part 60 if the add-
control device is not an oxidizer.
(4) You may use Method 18 of appendix A-6 to 40 CFR part 60 to
subtract methane emissions from measured total gaseous organic mass
emissions as carbon.
* * * * *
0
17. Section 63.3546 is amended by revising the introductory text and
paragraphs (a)(1) and (2), (b)(1) through (3), (d)(1), (e)(1) and (2),
(f)(1) through (3), and (f)(5) and (6) to read as follows:
Sec. 63.3546 How do I establish the emission capture system and add-
on control device operating limits during the performance test?
During performance tests required by Sec. 63.3540 and described in
Sec. Sec. 63.3543, 63.3544, and 63.3545, you must establish the
operating limits required by Sec. 63.3492 unless you have received
approval for alternative monitoring and operating limits under Sec.
63.8(f) as specified in Sec. 63.3492.
(a) * * *
(1) During performance tests, you must monitor and record the
combustion temperature at least once every 15 minutes during each of
the three test runs. You must monitor the temperature in the firebox of
the thermal oxidizer or immediately downstream of the firebox before
any substantial heat exchange occurs.
(2) For each performance test, use the data collected during the
performance test to calculate and record the average combustion
temperature maintained during the performance test. That average
combustion temperature is the minimum operating limit for your thermal
oxidizer.
(b) * * *
(1) During performance tests, you must monitor and record the
temperature at the inlet to the catalyst bed and the temperature
difference across the catalyst bed at least once every 15 minutes
during each of the three test runs.
(2) For each performance test, use the data collected during the
performance test to calculate and record the average temperature at the
inlet to the catalyst bed and the average temperature difference across
the catalyst bed maintained during the performance test. The average
temperature difference is the minimum operating limit for your
catalytic oxidizer.
(3) As an alternative to monitoring the temperature difference
across the catalyst bed, you may monitor the temperature at the inlet
to the catalyst bed and implement a site-specific inspection and
maintenance plan for your catalytic oxidizer as specified in paragraph
(b)(4) of this section. During performance tests, you must monitor and
record the temperature at the inlet to the catalyst bed at least once
every 15 minutes during each of the three test runs. For each
performance test, use the data collected during the performance test to
calculate and record the average temperature at the inlet to the
catalyst bed during the performance test. That is the minimum operating
limit for your catalytic oxidizer.
* * * * *
(d) * * *
(1) During performance tests, you must monitor and record the total
regeneration desorbing gas (e.g., steam or nitrogen) mass flow for each
regeneration cycle, and the carbon bed temperature after each carbon
bed regeneration and cooling cycle for the regeneration cycle either
immediately preceding or immediately following the performance test.
* * * * *
[[Page 10854]]
(e) * * *
(1) During performance tests, monitor and record the condenser
outlet (product side) gas temperature at least once every 15 minutes
during each of the three test runs of the performance test.
(2) For each performance test, use the data collected during the
performance test to calculate and record the average condenser outlet
(product side) gas temperature maintained during the performance test.
This average condenser outlet gas temperature is the maximum operating
limit for your condenser.
(f) * * *
(1) During performance tests, monitor and record the inlet
temperature to the desorption/reactivation zone of the concentrator at
least once every 15 minutes during each of the three runs of the
performance test.
(2) For each performance test, use the data collected during the
performance test to calculate and record the average temperature. This
is the minimum operating limit for the desorption/reactivation zone
inlet temperature.
(3) During each performance test, monitor and record an
indicator(s) of performance for the desorption/reactivation fan
operation at least once every 15 minutes during each of the three runs
of the performance test. The indicator can be speed in revolutions per
minute (rpm), power in amps, static pressure, or flow rate.
* * * * *
(5) During each performance test, monitor the rotational speed of
the concentrator at least once every 15 minutes during each of the
three runs of the performance test.
(6) For each performance test, use the data collected during the
performance test to calculate and record the average rotational speed.
This is the minimum operating limit for the rotational speed of the
concentrator. However, the indicator range for the rotational speed may
be changed if an engineering evaluation is conducted and a
determination made that the change in speed will not affect compliance
with the emission limit.
* * * * *
0
18. Section 63.3547 is amended by revising paragraphs (a)(4) and (5),
(a)(7), and (c)(3) introductory text to read as follows:
Sec. 63.3547 What are the requirements for continuous parameter
monitoring system installation, operation, and maintenance?
(a) * * *
(4) Before August 24, 2020, you must maintain the CPMS at all times
and have available necessary parts for routine repairs of the
monitoring equipment. On and after August 24, 2020, you must maintain
the CPMS at all times in accordance with Sec. 63.3500(b) and keep
necessary parts readily available for routine repairs of the monitoring
equipment.
(5) Before August 24, 2020, you must operate the CPMS and collect
emission capture system and add-on control device parameter data at all
times that a controlled coating operation is operating, except during
monitoring malfunctions, associated repairs, and required quality
assurance or control activities (including, if applicable, calibration
checks and required zero and span adjustments). On and after August 24,
2020, you must operate the CPMS and collect emission capture system and
add-on control device parameter data at all times in accordance with
Sec. 63.3500(b).
* * * * *
(7) A monitoring malfunction is any sudden, infrequent, not
reasonably preventable failure of the CPMS to provide valid data.
Monitoring failures that are caused, in part, by poor maintenance or
careless operation are not malfunctions. Before August 24, 2020, any
period for which the monitoring system is out of control and data are
not available for required calculations is a deviation from the
monitoring requirements. On and after August 24, 2020, except for
periods of required quality assurance or control activities, any period
for which the CPMS fails to operate and record data continuously as
required by paragraph (a)(5) of this section, or generates data that
cannot be included in calculating averages as specified in (a)(6) of
this section constitutes a deviation from the monitoring requirements.
* * * * *
(c) * * *
(3) For all thermal oxidizers and catalytic oxidizers, you must
meet the requirements in paragraphs (a) and (c)(3)(i) through (ii) of
this section for each gas temperature monitoring device. For the
purposes of this paragraph (c)(3), a thermocouple is part of the
temperature sensor.
* * * * *
0
19. Section 63.3550 is amended by revising the section heading and
paragraphs (a)(1), (a)(4), and (b)(1) to read as follows:
Sec. 63.3550 By what date must I conduct performance tests and
initial compliance demonstrations?
(a) * * *
(1) All emission capture systems, add-on control devices, and CPMS
must be installed and operating no later than the applicable compliance
date specified in Sec. 63.3483. You must conduct according to the
schedule in paragraphs (a)(1)(i) and (ii) of this section initial and
periodic performance tests of each capture system and add-on control
device according to Sec. Sec. 63.3553, 63.3554, and 63.3555 and
establish the operating limits required by Sec. 63.3492.
(i) You must conduct the initial performance test and establish the
operating limits required by Sec. 63.3492 no later than 180 days after
the applicable compliance date specified in Sec. 63.3483.
(ii) If you are not required to complete periodic performance tests
as a requirement of renewing your facility's operating permit under 40
CFR part 70 or 40 CFR part 71, you must conduct the first periodic
performance test before March 25, 2023, unless you already have
conducted a performance test on or after March 25, 2018. Thereafter you
must conduct a performance test no later than 5 years following the
previous performance test. Operating limits must be confirmed or
reestablished during each performance test. If you are required to
complete periodic performance tests as a requirement of renewing your
facility's operating permit under 40 CFR part 70 or 40 CFR part 71, you
must conduct the periodic testing in accordance with the terms and
schedule required by your permit conditions.
* * * * *
(4) For the initial compliance demonstration, you do not need to
comply with the operating limits for the emission capture system and
add-on control device required by Sec. 63.3492 until after you have
completed the initial performance tests specified in paragraph (a)(1)
of this section. Instead, you must maintain a log detailing the
operation and maintenance of the emission capture system, add-on
control device, and continuous parameter monitors during the period
between the compliance date and the performance test. You must begin
complying with the operating limits established based on the initial
performance tests specified in paragraph (a)(1) of this section on the
date you complete the performance tests.
(b) * * *
(1) All emission capture systems, add-on control devices, and CPMS
must be installed and operating no later than the applicable compliance
date specified in Sec. 63.3483. Except for solvent recovery systems
for which you conduct liquid-liquid material balances according to
Sec. 63.3541(i), you must conduct
[[Page 10855]]
according to the schedule in paragraphs (a)(1)(i) and (ii) of this
section initial and periodic performance tests of each capture system
and add-on control device according to the procedures in Sec. Sec.
63.3543, 63.3544, and 63.3545 and establish the operating limits
required by Sec. 63.3492.
(i) You must conduct the initial performance test and establish the
operating limits required by Sec. 63.3492 no later than 180 days after
the applicable compliance date specified in Sec. 63.3483.
(ii) If you are not required to complete periodic performance tests
as a requirement of renewing your facility's operating permit under 40
CFR part 70 or 40 CFR part 71, you must conduct the first periodic
performance test before March 25, 2023, unless you already have
conducted a performance test on or after March 25, 2018. Thereafter you
must conduct a performance test no later than 5 years following the
previous performance test. Operating limits must be confirmed or
reestablished during each performance test. If you are required to
complete periodic performance tests as a requirement of renewing your
facility's operating permit under 40 CFR part 70 or 40 CFR part 71, you
must conduct the periodic testing in accordance with the terms and
schedule required by your permit conditions.
* * * * *
0
20. Section 63.3552 is amended by revising paragraph (g) to read as
follows:
Sec. 63.3552 How do I demonstrate continuous compliance with the
emission limitations?
* * * * *
(g) Before August 24, 2020, consistent with Sec. Sec. 63.6(e) and
63.7(e)(1), deviations that occur during a period of startup, shutdown,
or malfunction of the emission capture system, add-on control device,
or coating operation that may affect emission capture or control device
efficiency are not violations if you demonstrate to the Administrator's
satisfaction that you were operating in accordance with Sec.
63.6(e)(1). The Administrator will determine whether deviations that
occur during a period you identify as a startup, shutdown, or
malfunction are violations, according to the provisions in Sec.
63.6(e). On and after August 24, 2020 deviations that occur due to
malfunction of the emission capture system, add-on control device, or
coating operation that may affect emission capture or control device
efficiency are required to operate in accordance with Sec. 63.3500(b).
The Administrator will determine whether the deviations are violations
according to the provisions in Sec. 63.3500(b).
* * * * *
0
21. Section 63.3553 is amended by revising paragraphs (a) introductory
text and (a)(1) to read as follows:
Sec. 63.3553 What are the general requirements for performance tests?
(a) Before August 24, 2020, you must conduct each performance test
required by Sec. 63.3550 according to the requirements in Sec.
63.7(e)(1) and under the conditions in this section unless you obtain a
waiver of the performance test according to the provisions in Sec.
63.7(h). On and after August 24, 2020, you must conduct each
performance test required by Sec. 63.3550 according to the
requirements in this section unless you obtain a waiver of the
performance test according to the provisions in Sec. 63.7(h).
(1) Representative coating operating conditions. You must conduct
the performance test under representative operating conditions for the
coating operation(s). Operations during periods of startup, shutdown,
or nonoperation do not constitute representative conditions for
purposes of conducting a performance test. The owner or operator may
not conduct performance tests during periods of malfunction. You must
record the process information that is necessary to document operating
conditions during the test and explain why the conditions represent
normal operation. Upon request, you must make available to the
Administrator such records as may be necessary to determine the
conditions of performance tests.
* * * * *
0
22. Section 63.3555 is amended by revising the introductory text,
paragraph (b) introductory text, and paragraphs (b)(1) through (4) to
read as follows:
Sec. 63.3555 How do I determine the outlet THC emissions and add-on
control device emission destruction or removal efficiency?
You must use the procedures and test methods in this section to
determine either the outlet THC emissions or add-on control device
emission destruction or removal efficiency as part of the performance
tests required by Sec. 63.3550. You must conduct three test runs as
specified in Sec. 63.7(e)(3), and each test run must last at least 1
hour.
* * * * *
(b) Measure total gaseous organic mass emissions as carbon at the
inlet and outlet of the add-on control device simultaneously using
either Method 25 or 25A of appendix A-7 to 40 CFR part 60 as specified
in paragraphs (b)(1) through (3) of this section. You must use the same
method for both the inlet and outlet measurements.
(1) Use Method 25 of appendix A-7 to 40 CFR part 60 if the add-on
control device is an oxidizer, and you expect the total gaseous organic
concentration as carbon to be more than 50 ppm at the control device
outlet.
(2) Use Method 25A of appendix A-7 to 40 CFR part 60 if the add-on
control device is an oxidizer, and you expect the total gaseous organic
concentration as carbon to be 50 ppm or less at the control device
outlet.
(3) Use Method 25A of appendix A-7 to 40 CFR part 60 if the add-on
control device is not an oxidizer.
(4) You may use Method 18 of appendix A-6 to 40 CFR part 60 to
subtract methane emissions from measured total gaseous organic mass
emissions as carbon.
* * * * *
0
23. Section 63.3556 is amended by revising the introductory text and
paragraphs (a)(1) and (2), (b)(1) through (3), (d)(1), (e)(1) and (2),
(f)(1) through (3), and (f)(5) and (6) to read as follows:
Sec. 63.3556 How do I establish the emission capture system and add-
on control device operating limits during the performance test?
During the performance tests required by Sec. 63.3550 and
described in Sec. Sec. 63.3553, 63.3554, and 63.3555, you must
establish the operating limits required by Sec. 63.3492 according to
this section, unless you have received approval for alternative
monitoring and operating limits under Sec. 63.8(f) as specified in
Sec. 63.3492.
(a) * * *
(1) During performance tests, you must monitor and record the
combustion temperature at least once every 15 minutes during each of
the three test runs. You must monitor the temperature in the firebox of
the thermal oxidizer or immediately downstream of the firebox before
any substantial heat exchange occurs.
(2) For each performance test, use the data collected during the
performance test to calculate and record the average combustion
temperature maintained during the performance test. That average
combustion temperature is the minimum operating limit for your thermal
oxidizer.
(b) * * *
(1) During performance tests, you must monitor and record the
temperature at the inlet to the catalyst bed and the temperature
difference across the catalyst bed at least once every 15 minutes
during each of the three test runs.
[[Page 10856]]
(2) For each performance test, use the data collected during the
performance test to calculate and record the average temperature at the
inlet to the catalyst bed and the average temperature difference across
the catalyst bed maintained during the performance test. The average
temperature difference is the minimum operating limit for your
catalytic oxidizer.
(3) As an alternative to monitoring the temperature difference
across the catalyst bed, you may monitor the temperature at the inlet
to the catalyst bed and implement a site-specific inspection and
maintenance plan for your catalytic oxidizer as specified in paragraph
(b)(4) of this section. During performance tests, you must monitor and
record the temperature at the inlet to the catalyst bed at least once
every 15 minutes during each of the three test runs. Use the data
collected during each performance test to calculate and record the
average temperature at the inlet to the catalyst bed during the
performance test. That is the minimum operating limit for your
catalytic oxidizer.
* * * * *
(d) * * *
(1) You must monitor and record the total regeneration desorbing
gas (e.g., steam or nitrogen) mass flow for each regeneration cycle,
and the carbon bed temperature after each carbon bed regeneration and
cooling cycle for the regeneration cycle either immediately preceding
or immediately following performance tests.
* * * * *
(e) * * *
(1) During performance tests, monitor and record the condenser
outlet (product side) gas temperature at least once every 15 minutes
during each of the three test runs.
(2) For each performance test, use the data collected during the
performance test to calculate and record the average condenser outlet
(product side) gas temperature maintained during the performance test.
This average condenser outlet gas temperature is the maximum operating
limit for your condenser.
(f) * * *
(1) During performance tests, monitor and record the inlet
temperature to the desorption/reactivation zone of the concentrator at
least once every 15 minutes during each of the three runs of the
performance test.
(2) For each performance test, use the data collected during the
performance test to calculate and record the average temperature. This
is the minimum operating limit for the desorption/reactivation zone
inlet temperature.
(3) During performance tests, monitor and record an indicator(s) of
performance for the desorption/reactivation fan operation at least once
every 15 minutes during each of the three runs of the performance test.
The indicator can be speed in rpm, power in amps, static pressure, or
flow rate.
* * * * *
(5) During performance tests, monitor the rotational speed of the
concentrator at least once every 15 minutes during each of the three
runs of a performance test.
(6) For each performance test, use the data collected during the
performance test to calculate and record the average rotational speed.
This is the minimum operating limit for the rotational speed of the
concentrator. However, the indicator range for the rotational speed may
be changed if an engineering evaluation is conducted and a
determination made that the change in speed will not affect compliance
with the emission limit.
* * * * *
0
24. Section 63.3557 is amended by revising paragraphs (a)(4) and (5),
(a)(7), and (c)(3) introductory text to read as follows:
Sec. 63.3557 What are the requirements for continuous parameter
monitoring system installation, operation, and maintenance?
(a) * * *
(4) You must maintain the CPMS at all times in accordance with
Sec. 63.3500(b) and have readily available necessary parts for routine
repairs of the monitoring equipment.
(5) You must operate the CPMS and collect emission capture system
and add-on control device parameter data at all times in accordance
with Sec. 63.3500(b) that a controlled coating operation is operating,
except during monitoring malfunctions, associated repairs, and required
quality assurance or control activities (including, if applicable,
calibration checks and required zero and span adjustments).
* * * * *
(7) A monitoring malfunction is any sudden, infrequent, not
reasonably preventable failure of the CPMS to provide valid data.
Monitoring failures that are caused, in part, by poor maintenance or
careless operation are not malfunctions. Before August 24, 2020, any
period for which the monitoring system is out of control and data are
not available for required calculations is a deviation from the
monitoring requirements. On and after August 24, 2020, except for
periods of required quality assurance or control activities, any period
for which the CPMS fails to operate and record data continuously as
required by paragraph (a)(5) of this section, or generates data that
cannot be included in calculating averages as specified in (a)(6) of
this section constitutes a deviation from the monitoring requirements.
* * * * *
(c) * * *
(3) For all thermal oxidizers and catalytic oxidizers, you must
meet the requirements in paragraphs (a) and (c)(3)(i) through (ii) of
this section for each gas temperature monitoring device. For the
purposes of this paragraph (c)(3), a thermocouple is part of the
temperature sensor.
* * * * *
0
25. Section 63.3561 is amended by removing the definition for
``Deviation'' and adding definitions for ``Deviation, before'' and
``Deviation, on and after'' in alphabetical order to read as follows:
Sec. 63.3561 What definitions apply to this subpart?
* * * * *
Deviation, before August 24, 2020, means any instance in which an
affected source subject to this subpart or an owner or operator of such
a source:
(1) Fails to meet any requirement or obligation established by this
subpart including but not limited to any emission limit, operating
limit, or work practice standard; or
(2) Fails to meet any term or condition that is adopted to
implement an applicable requirement in this subpart and that is
included in the operating permit for any affected source required to
obtain such a permit; or
(3) Fails to meet any emission limit, operating limit, or work
practice standard in this subpart during startup, shutdown, or
malfunction regardless of whether or not such failure is permitted by
this subpart.
Deviation, on and after August 24, 2020, means any instance in
which an affected source subject to this subpart or an owner or
operator of such a source:
(1) Fails to meet any requirement or obligation established by this
subpart including but not limited to any emission limit, operating
limit, or work practice standard; or
(2) Fails to meet any term or condition that is adopted to
implement an applicable requirement in this subpart and that is
included in the operating permit for any affected source required to
obtain such a permit.
* * * * *
0
26. Table 5 to subpart KKKK of part 63 is revised to read as follows:
[[Page 10857]]
Table 5 to Subpart KKKK of Part 63--Applicability of General Provisions to Subpart KKKK
You must comply with the applicable General Provisions requirements according to the following table:
----------------------------------------------------------------------------------------------------------------
Applicable to subpart
Citation Subject KKKK Explanation
----------------------------------------------------------------------------------------------------------------
Sec. 63.1(a)(1)-(4)................ General Applicability.. Yes....................
Sec. 63.1(a)(6).................... Source Category Listing Yes....................
Sec. 63.1(a)(10)-(12).............. Timing and Overlap Yes....................
Clarifications.
Sec. 63.1(b)(1).................... Initial Applicability Yes.................... Applicability to
Determination. subpart KKKK is also
specified in Sec.
63.3481.
Sec. 63.1(b)(3).................... Applicability Yes....................
Determination
Recordkeeping.
Sec. 63.1(c)(1).................... Applicability after Yes....................
Standard Established.
Sec. 63.1(c)(2).................... Applicability of Permit No..................... Area sources are not
Program for Area subject to subpart
Sources. KKKK.
Sec. 63.1(c)(5).................... Extensions and Yes....................
Notifications.
Sec. 63.1(e)....................... Applicability of Permit Yes....................
Program before
Relevant Standard is
Set.
Sec. 63.2.......................... Definitions............ Yes.................... Additional definitions
are specified in Sec.
63.3561.
Sec. 63.3.......................... Units and Abbreviations Yes....................
Sec. 63.4(a)(1)-(2)................ Prohibited Activities.. Yes....................
Sec. 63.4(b)-(c)................... Circumvention/ Yes....................
Fragmentation.
Sec. 63.5(a)....................... Construction/ Yes....................
Reconstruction.
Sec. 63.5(b)(1), (3), (4), (6)..... Requirements for Yes....................
Existing, Newly
Constructed, and
Reconstructed Sources.
Sec. 63.5(d)(1)(i)-(ii)(F), Application for Yes....................
(d)(1)(ii)(H), (d)(1)(ii)(J), Approval of
(d)(1)(iii), (d)(2)-(4). Construction/
Reconstruction.
Sec. 63.5(e)....................... Approval of Yes....................
Construction/
Reconstruction.
Sec. 63.5(f)....................... Approval of Yes....................
Construction/
Reconstruction Based
on Prior State Review.
Sec. 63.6(a)....................... Compliance with Yes....................
Standards and
Maintenance
Requirements--Applicab
ility.
Sec. 63.6(b)(1)-(5), (b)(7)........ Compliance Dates for Yes.................... Section 63.3483
New and Reconstructed specifies the
Sources. compliance dates.
Sec. 63.6(c)(1), (2), (5).......... Compliance Dates for Yes.................... Section 63.3483
Existing Sources. specifies the
compliance dates.
Sec. 63.6(e)(1)(i)-(ii)............ Operation and Yes before August 24, See Sec. 63.3500(b)
Maintenance. 2020, No on and after for general duty
August 24, 2020. requirement.
Sec. 63.6(e)(1)(iii)............... Operation and Yes....................
Maintenance.
Sec. 63.6(e)(3)(i), (e)(3)(iii)- SSMP................... Yes before August 24,
(ix). 2020, No on and after
August 24, 2020.
Sec. 63.6(f)(1).................... Compliance Except Yes before August 24,
during Startup, 2020, No on and after
Shutdown, and August 24, 2020.
Malfunction.
Sec. 63.6(f)(2)-(3)................ Methods for Determining Yes....................
Compliance.
Sec. 63.6(g)....................... Use of an Alternative Yes....................
Standard.
Sec. 63.6(h)....................... Compliance with Opacity/ No..................... Subpart KKKK does not
Visible Emission establish opacity
Standards. standards and does not
require continuous
opacity monitoring
systems (COMS).
Sec. 63.6(i)(1)-(14)............... Extension of Compliance Yes....................
Sec. 63.6(i)(16)................... Compliance Extensions Yes....................
and Administrator's
Authority.
Sec. 63.6(j)....................... Presidential Compliance Yes....................
Exemption.
Sec. 63.7(a)(1).................... Performance Test Yes.................... Applies to all affected
Requirements--Applicab sources. Additional
ility. requirements for
performance testing
are specified in Sec.
Sec. 63.3543,
63.3544, 63.3545,
63.3554, and 63.3555.
Sec. 63.7(a)(2) except (a)(2)(i)- Performance Test Yes.................... Applies only to
(viii). Requirements--Dates. performance tests for
capture system and
control device
efficiency at sources
using these to comply
with the standards.
Sections 63.3540 and
63.3550 specify the
schedule for
performance test
requirements that are
earlier than those
specified in Sec.
63.7(a)(2).
[[Page 10858]]
Sec. 63.7(a)(3).................... Performance Tests Yes....................
Required by the
Administrator.
Sec. 63.7(b)-(d)................... Performance Test Yes.................... Applies only to
Requirements--Notifica performance tests for
tion, Quality capture system and add-
Assurance, Facilities on control device
Necessary for Safe efficiency at sources
Testing, Conditions using these to comply
During Test. with the standards.
Sec. 63.7(e)(1).................... Conduct of Performance Yes before August 24, See Sec. Sec.
Tests. 2020, No on and after 63.3543 and 63.3553.
August 24, 2020.
Sec. 63.7(e)(2)-(4)................ Conduct of Performance Yes....................
Tests.
Sec. 63.7(f)....................... Performance Test Yes.................... Applies to all test
Requirements--Use of methods except those
Alternative Test used to determine
Method. capture system
efficiency.
Sec. 63.7(g)-(h)................... Performance Test Yes.................... Applies only to
Requirements--Data performance tests for
Analysis, capture system and add-
Recordkeeping, on control device
Reporting, Waiver of efficiency at sources
Test. using these to comply
with the standards.
Sec. 63.8(a)(1)-(2)................ Monitoring Yes.................... Applies only to
Requirements--Applicab monitoring of capture
ility. system and add-on
control device
efficiency at sources
using these to comply
with the standards.
Additional
requirements for
monitoring are
specified in Sec.
Sec. 63.3547 and
63.3557.
Sec. 63.8(a)(4).................... Additional Monitoring No..................... Subpart KKKK does not
Requirements. have monitoring
requirements for
flares.
Sec. 63.8(b)....................... Conduct of Monitoring.. Yes....................
Sec. 63.8(c)(1).................... Continuous Monitoring Yes before August 24, Sections 63.3547 and
System (CMS) Operation 2020, No on and after 63.3557 specify the
and Maintenance. August 24, 2020. requirements for the
operation of CMS for
capture systems and
add-on control devices
at sources using these
to comply.
Sec. 63.8(c)(2)-(3)................ CMS Operation and Yes.................... Applies only to
Maintenance. monitoring of capture
system and add-on
control device
efficiency at sources
using these to comply
with the standards.
Additional
requirements for CMS
operations and
maintenance are
specified in Sec.
Sec. 63.3547 and
63.3557.
Sec. 63.8(c)(4).................... CMS.................... No..................... Sections 63.3547 and
63.3557 specify the
requirements for the
operation of CMS for
capture systems and
add-on control devices
at sources using these
to comply.
Sec. 63.8(c)(5).................... COMS................... No..................... Subpart KKKK does not
have opacity or
visible emission
standards.
Sec. 63.8(c)(6).................... CMS Requirements....... No..................... Sections 63.3547 and
63.3557 specify the
requirements for
monitoring systems for
capture systems and
add-on control devices
at sources using these
to comply.
Sec. 63.8(c)(7).................... CMS Out-of-Control Yes....................
Periods.
Sec. 63.8(c)(8).................... CMS Out-of-Control No..................... Section 63.3511
Periods Reporting. requires reporting of
CMS out of control
periods.
Sec. 63.8(d)-(e)................... Quality Control Program No.....................
and CMS Performance
Evaluation.
Sec. 63.8(f)(1)-(5)................ Use of an Alternative Yes....................
Monitoring Method.
Sec. 63.8(f)(6).................... Alternative to Relative No..................... Section 63.8(f)(6)
Accuracy Test. provisions are not
applicable because
subpart KKKK does not
require CEMS.
[[Page 10859]]
Sec. 63.8(g)....................... Data Reduction......... No..................... Sections 63.3542,
63.3547, 63.3552 and
63.3557 specify
monitoring data
reduction.
Sec. 63.9(a)....................... Notification Yes....................
Applicability.
Sec. 63.9(b)(1)-(2)................ Initial Notifications.. Yes....................
Sec. 63.9(b)(4)(i), (b)(4)(v), Application for Yes....................
(b)(5). Approval of
Construction or
Reconstruction.
Sec. 63.9(c)....................... Request for Extension Yes....................
of Compliance.
Sec. 63.9(d)....................... Special Compliance Yes....................
Requirement
Notification.
Sec. 63.9(e)....................... Notification of Yes.................... Applies only to capture
Performance Test. system and add-on
control device
performance tests at
sources using these to
comply with the
standards.
Sec. 63.9(f)....................... Notification of Visible No..................... Subpart KKKK does not
Emissions/Opacity Test. have opacity or
visible emission
standards.
Sec. 63.9(g)....................... Additional No.....................
Notifications When
Using CMS.
Sec. 63.9(h)(1)-(3)................ Notification of Yes.................... Section 63.3510
Compliance Status. specifies the dates
for submitting the
notification of
compliance status.
Sec. 63.9(h)(5)-(6)................ Clarifications......... Yes....................
Sec. 63.9(i)....................... Adjustment of Submittal Yes....................
Deadlines.
Sec. 63.9(j)....................... Change in Previous Yes....................
Information.
Sec. 63.10(a)...................... Recordkeeping/ Yes....................
Reporting--Applicabili
ty and General
Information.
Sec. 63.10(b)(1)................... General Recordkeeping Yes.................... Additional requirements
Requirements. are specified in Sec.
Sec. 63.3512 and
63.3513.
Sec. 63.10(b)(2)(i)-(ii)........... Recordkeeping of Yes before August 24, See Sec. 63.3512(i).
Occurrence and 2020, No on and after
Duration of Startups August 24, 2020.
and Shutdowns and of
Failures to Meet
Standards.
Sec. 63.10(b)(2)(iii).............. Recordkeeping Relevant Yes....................
to Maintenance of Air
Pollution Control and
Monitoring Equipment.
Sec. 63.10(b)(2)(iv)-(v)........... Actions Taken to Yes before August 24, See Sec.
Minimize Emissions 2020, No on and after 63.3512(i)(4) for a
During Startup, August 24, 2020. record of actions
Shutdown, and taken to minimize
Malfunction. emissions duration a
deviation from the
standard.
Sec. 63.10(b)(2)(vi)............... Recordkeeping for CMS Yes before August 24, See Sec. 63.3512(i)
Malfunctions. 2020, No on and after for records of periods
August 24, 2020. of deviation from the
standard, including
instances where a CMS
is inoperative or out-
of-control.
Sec. 63.10(b)(2) (vii)-(xii)....... Records................ Yes....................
Sec. 63.10(b)(2) (xiii)............ ....................... No.....................
Sec. 63.10(b)(2) (xiv)............. ....................... Yes....................
Sec. 63.10(b)(3)................... Recordkeeping Yes....................
Requirements for
Applicability
Determinations.
Sec. 63.10(c)(1)................... Additional Yes....................
Recordkeeping
Requirements for
Sources with CMS.
Sec. 63.10(c)(5)-(6)............... ....................... Yes....................
Sec. 63.10(c)(7)-(8)............... Additional No..................... See Sec. 63.3512(i)
Recordkeeping for records of periods
Requirements for of deviation from the
Sources with CMS. standard, including
instances where a CMS
is inoperative or out-
of-control.
Sec. 63.10(c)(10)-(14)............. Additional Yes....................
Recordkeeping
Requirements for
Sources with CMS.
Sec. 63.10(c)(15).................. Records Regarding the Yes before August 24,
Startup, Shutdown, and 2020, No on and after
Malfunction Plan. August 24, 2020.
Sec. 63.10(d)(1)................... General Reporting Yes.................... Additional requirements
Requirements. are specified in Sec.
63.3511.
[[Page 10860]]
Sec. 63.10(d)(2)................... Report of Performance Yes.................... Additional requirements
Test Results. are specified in Sec.
63.3511(b).
Sec. 63.10(d)(3)................... Reporting Opacity or No..................... Subpart KKKK does not
Visible Emissions require opacity or
Observations. visible emissions
observations.
Sec. 63.10(d)(4)................... Progress Reports for Yes....................
Sources with
Compliance Extensions.
Sec. 63.10(d)(5)................... Startup, Shutdown, Yes before August 24, See Sec.
Malfunction Reports. 2020, No on and after 63.3511(a)(7) and (8).
August 24, 2020.
Sec. 63.10(e)(1)-(2)............... Additional CMS Reports. No.....................
Sec. 63.10(e)(3)................... Excess Emissions/CMS No..................... Section 63.3511(b)
Performance Reports. specifies the contents
of periodic compliance
reports.
Sec. 63.10(e)(4)................... COMS Data Reports...... No..................... Subpart KKKK does not
specify requirements
for opacity or COMS.
Sec. 63.10(f)...................... Recordkeeping/Reporting Yes....................
Waiver.
Sec. 63.11......................... Control Device No..................... Subpart KKKK does not
Requirements/Flares. specify use of flares
for compliance.
Sec. 63.12......................... State Authority and Yes....................
Delegations.
Sec. 63.13(a)...................... Addresses.............. Yes before August 24,
2020, No on and after
August 24, 2020.
Sec. 63.13(b)...................... Submittal to State Yes....................
Agencies.
Sec. 63.13(c)...................... Submittal to State Yes before August 24,
Agencies. 2020, No unless the
state requires the
submittal via CEDRI,
on and after August
24, 2020.
Sec. 63.14......................... Incorporation by Yes....................
Reference.
Sec. 63.15......................... Availability of Yes....................
Information/
Confidentiality.
----------------------------------------------------------------------------------------------------------------
0
27. Table 8 to subpart KKKK of part 63 is added to read as follows:
Table 8 to Subpart KKKK of Part 63--List of Hazardous Air Pollutants
That Must Be Counted Toward Total Organic HAP Content if Present at 0.1
Percent or More by Mass
------------------------------------------------------------------------
Chemical name CAS No.
------------------------------------------------------------------------
1,1,2,2-Tetrachloroethane............................... 79-34-5
1,1,2-Trichloroethane................................... 79-00-5
1,1-Dimethylhydrazine................................... 57-14-7
1,2-Dibromo-3-chloropropane............................. 96-12-8
1,2-Diphenylhydrazine................................... 122-66-7
1,3-Butadiene........................................... 106-99-0
1,3-Dichloropropene..................................... 542-75-6
1,4-Dioxane............................................. 123-91-1
2,4,6-Trichlorophenol................................... 88-06-2
2,4/2,6-Dinitrotoluene (mixture)........................ 25321-14-6
2,4-Dinitrotoluene...................................... 121-14-2
2,4-Toluene diamine..................................... 95-80-7
2-Nitropropane.......................................... 79-46-9
3,3'-Dichlorobenzidine.................................. 91-94-1
3,3'-Dimethoxybenzidine................................. 119-90-4
3,3'-Dimethylbenzidine.................................. 119-93-7
4,4'-Methylene bis(2-chloroaniline)..................... 101-14-4
Acetaldehyde............................................ 75-07-0
Acrylamide.............................................. 79-06-1
Acrylonitrile........................................... 107-13-1
Allyl chloride.......................................... 107-05-1
alpha-Hexachlorocyclohexane (a-HCH)..................... 319-84-6
Aniline................................................. 62-53-3
Benzene................................................. 71-43-2
Benzidine............................................... 92-87-5
Benzotrichloride........................................ 98-07-7
Benzyl chloride......................................... 100-44-7
beta-Hexachlorocyclohexane (b-HCH)...................... 319-85-7
Bis(2-ethylhexyl)phthalate.............................. 117-81-7
[[Page 10861]]
Bis(chloromethyl)ether.................................. 542-88-1
Bromoform............................................... 75-25-2
Captan.................................................. 133-06-2
Carbon tetrachloride.................................... 56-23-5
Chlordane............................................... 57-74-9
Chlorobenzilate......................................... 510-15-6
Chloroform.............................................. 67-66-3
Chloroprene............................................. 126-99-8
Cresols (mixed)......................................... 1319-77-3
DDE..................................................... 3547-04-4
Dichloroethyl ether..................................... 111-44-4
Dichlorvos.............................................. 62-73-7
Epichlorohydrin......................................... 106-89-8
Ethyl acrylate.......................................... 140-88-5
Ethylene dibromide...................................... 106-93-4
Ethylene dichloride..................................... 107-06-2
Ethylene oxide.......................................... 75-21-8
Ethylene thiourea....................................... 96-45-7
Ethylidene dichloride (1,1-Dichloroethane).............. 75-34-3
Formaldehyde............................................ 50-00-0
Heptachlor.............................................. 76-44-8
Hexachlorobenzene....................................... 118-74-1
Hexachlorobutadiene..................................... 87-68-3
Hexachloroethane........................................ 67-72-1
Hydrazine............................................... 302-01-2
Isophorone.............................................. 78-59-1
Lindane (hexachlorocyclohexane, all isomers)............ 58-89-9
m-Cresol................................................ 108-39-4
Methylene chloride...................................... 75-09-2
Naphthalene............................................. 91-20-3
Nitrobenzene............................................ 98-95-3
Nitrosodimethylamine.................................... 62-75-9
o-Cresol................................................ 95-48-7
o-Toluidine............................................. 95-53-4
Parathion............................................... 56-38-2
p-Cresol................................................ 106-44-5
p-Dichlorobenzene....................................... 106-46-7
Pentachloronitrobenzene................................. 82-68-8
Pentachlorophenol....................................... 87-86-5
Propoxur................................................ 114-26-1
Propylene dichloride.................................... 78-87-5
Propylene oxide......................................... 75-56-9
Quinoline............................................... 91-22-5
Tetrachloroethene....................................... 127-18-4
Toxaphene............................................... 8001-35-2
Trichloroethylene....................................... 79-01-6
Trifluralin............................................. 1582-09-8
Vinyl bromide........................................... 593-60-2
Vinyl chloride.......................................... 75-01-4
Vinylidene chloride..................................... 75-35-4
------------------------------------------------------------------------
Subpart SSSS--National Emission Standards for Hazardous Air
Pollutants: Surface Coating of Metal Coil
0
28. Section 63.5090 is amended by revising paragraph (a) and adding
paragraph (e) to read as follows:
Sec. 63.5090 Does this subpart apply to me?
(a) The provisions of this subpart apply to each facility that is a
major source of HAP, as defined in Sec. 63.2, at which a coil coating
line is operated, except as provided in paragraphs (b) and (e) of this
section.
* * * * *
(e) This subpart does not apply to the application of incidental
markings (including letters, numbers, or symbols) that are added to
bare metal coils and that are used for only product identification or
for product inventory control. The application of letters, numbers, or
symbols to a coated metal coil is considered a coil coating process and
part of the coil coating affected source.
0
29. Section 63.5110 is amended by removing the definition for
``Deviation'' and adding definitions for ``Deviation, before'' and
``Deviation, on and after'' in alphabetical order to read as follows:
Sec. 63.5110 What special definitions are used in this subpart?
* * * * *
Deviation, before August 24, 2020, means any instance in which an
affected source, subject to this subpart, or an owner or operator of
such a source:
(1) Fails to meet any requirement or obligation established by this
subpart including, but not limited to, any
[[Page 10862]]
emission limitation (including any operating limit) or work practice
standard; or
(2) Fails to meet any term or condition that is adopted to
implement an applicable requirement in this subpart and that is
included in the operating permit for any affected source required to
obtain such a permit; or
(3) Fails to meet any emission limitation (including any operating
limit) or work practice standard in this subpart during start-up,
shutdown, or malfunction, regardless of whether or not such failure is
permitted by this subpart.
Deviation, on and after August 24, 2020, means any instance in
which an affected source, subject to this subpart, or an owner or
operator of such a source:
(1) Fails to meet any requirement or obligation established by this
subpart including, but not limited to, any emission limitation
(including any operating limit) or work practice standard; or
(2) Fails to meet any term or condition that is adopted to
implement an applicable requirement in this subpart and that is
included in the operating permit for any affected source required to
obtain such a permit.
* * * * *
0
30. Section 63.5121 is amended by revising paragraph (a) to read as
follows:
Sec. 63.5121 What operating limits must I meet?
(a) Except as provided in paragraph (b) of this section, for any
coil coating line for which you use an add-on control device, unless
you use a solvent recovery system and conduct a liquid-liquid material
balance according to Sec. 63.5170(e)(1), you must meet the applicable
operating limits specified in Table 1 to this subpart. You must
establish the operating limits during performance tests according to
the requirements in Sec. 63.5160(d)(3) and Table 1 to Sec. 63.5160.
You must meet the operating limits established during the most recent
performance test required in Sec. 63.5160 at all times after you
establish them.
* * * * *
0
31. Section 63.5130 is amended by revising paragraph (a) to read as
follows:
Sec. 63.5130 When must I comply?
(a) For an existing affected source, the compliance date is June
10, 2005.
* * * * *
0
32. Section 63.5140 is amended by:
0
a. Revising paragraph (a);
0
b. Redesignating paragraph (b) as (c); and
0
c. Adding paragraph (b).
The revision and addition read as follows:
Sec. 63.5140 What general requirements must I meet to comply with the
standards?
(a) Before August 24, 2020, you must be in compliance with the
applicable emission standards in Sec. 63.5120 and the operating limits
in Table 1 to this subpart at all times, except during periods of
start-up, shutdown, and malfunction of any capture system and control
device used to comply with this subpart. On and after August 24, 2020
you must be in compliance with the applicable emission standards in
Sec. 63.5120 and the operating limits in Table 1 to this subpart at
all times. If you are complying with the emission standards of this
subpart without the use of a capture system and control device, you
must be in compliance with the standards at all times.
(b) Before August 24, 2020, you must always operate and maintain
your affected source, including air pollution control and monitoring
equipment, according to the provisions in Sec. 63.6(e)(1). On and
after August 24, 2020, at all times, you must operate and maintain your
affected source, including associated air pollution control equipment
and monitoring equipment, in a manner consistent with safety and good
air pollution control practices for minimizing emissions. The general
duty to minimize emissions does not require the owner or operator to
make any further efforts to reduce emissions if levels required by the
applicable standard have been achieved. Determination of whether a
source is operating in compliance with operation and maintenance
requirements will be based on information available to the
Administrator that may include, but is not limited to, monitoring
results, review of operation and maintenance procedures, review of
operation and maintenance records, and inspection of the affected
source.
* * * * *
0
33. Section 63.5150 is amended by revising paragraph (a) introductory
text, paragraph (a)(4)(i), and paragraph (b) to read as follows:
Sec. 63.5150 If I use a control device to comply with the emission
standards, what monitoring must I do?
* * * * *
(a) To demonstrate continuing compliance with the standards, you
must monitor and inspect each capture system and each control device
required to comply with Sec. 63.5120 following the date on which the
initial performance test of the capture system and control device is
completed. You must install and operate the monitoring equipment as
specified in paragraphs (a)(1) through (4) of this section. On and
after August 24, 2020, you must also maintain the monitoring equipment
at all times in accordance with Sec. 63.5140(b) and keep the necessary
parts readily available for routine repairs of the monitoring
equipment.
* * * * *
(4) * * *
(i) The monitoring plan must identify the operating parameter to be
monitored to ensure that the capture efficiency measured during
compliance tests is maintained, explain why this parameter is
appropriate for demonstrating ongoing compliance, and identify the
specific monitoring procedures.
* * * * *
(b) If an operating parameter monitored in accordance with
paragraphs (a)(3) and (4) of this section is out of the allowed range
specified in Table 1 to this subpart it will be considered a deviation
from the operating limit.
0
34. Section 63.5160 is amended by revising Table 1 and paragraphs
(b)(1)(i), (b)(2), (b)(4), (c), (d) introductory text, (d)(1)
introductory text, (d)(1)(vi) introductory text, (d)(1)(vii), (d)(2),
(d)(3) introductory text, (d)(3)(i)(A), (d)(3)(ii)(D) introductory
text, and (e) introductory text to read as follows:
Sec. 63.5160 What performance tests must I complete?
Table 1 to Sec. 63.5160--Required Performance Testing Summary
------------------------------------------------------------------------
If you control HAP on your
coil coating line by: You must:
------------------------------------------------------------------------
1. Limiting HAP or Volatile Determine the HAP or volatile matter and
matter content of coatings. solids content of coating materials
according to the procedures in Sec.
63.5160(b) and (c).
[[Page 10863]]
2. Using a capture system and Except as specified in paragraph (a) of
add-on control device. this section, conduct an initial
performance test within 180 days of the
applicable compliance date in Sec.
63.5130, and conduct periodic
performance tests within 5 years
following the previous performance test,
as follows: If you are not required to
complete periodic performance tests as a
requirement of renewing your facility's
operating permit under 40 CFR part 70 or
40 CFR part 71, you must conduct the
first periodic performance test before
March 25, 2023, unless you already have
conducted a performance test on or after
March 25, 2018; thereafter, you must
conduct a performance test no later than
5 years following the previous
performance test. Operating limits must
be confirmed or reestablished during
each performance test. If you are
required to complete periodic
performance tests as a requirement of
renewing your facility's operating
permit under 40 CFR part 70 or 40 CFR
part 71, you must conduct the periodic
testing in accordance with the terms and
schedule required by your permit
conditions. For each performance test:
(1) For each capture and control system,
determine the destruction or removal
efficiency of each control device
according to Sec. 63.5160(d) and the
capture efficiency of each capture
system according to Sec. 63.5160(e),
and (2) confirm or re-establish the
operating limits.
------------------------------------------------------------------------
* * * * *
(b) * * *
(1) * * *
(i) Count only those organic HAP in Table 3 to this subpart that
are measured to be present at greater than or equal to 0.1 weight
percent and greater than or equal to 1.0 weight percent for other
organic HAP compounds.
* * * * *
(2) Method 24 in appendix A-7 of part 60. For coatings, you may
determine the total volatile matter content as weight fraction of
nonaqueous volatile matter and use it as a substitute for organic HAP,
using Method 24 in appendix A-7 of part 60. As an alternative to using
Method 24, you may use ASTM D2369-10 (2015), ``Test Method for Volatile
Content of Coatings'' (incorporated by reference, see Sec. 63.14). The
determination of total volatile matter content using a method specified
in this paragraph (b)(2) or as provided in paragraph (b)(3) of this
section may be performed by the manufacturer of the coating and the
results provided to you.
* * * * *
(4) Formulation data. You may use formulation data provided that
the information represents each organic HAP in Table 3 to this subpart
that is present at a level equal to or greater than 0.1 percent and
equal to or greater than 1.0 percent for other organic HAP compounds in
any raw material used, weighted by the mass fraction of each raw
material used in the material. Formulation data may be provided to you
by the manufacturer of the coating material. In the event of any
inconsistency between test data obtained with the test methods
specified in paragraphs (b)(1) through (3) of this section and
formulation data, the test data will govern.
(c) Solids content and density. You must determine the solids
content and the density of each coating material applied. You may
determine the volume solids content using ASTM D2697-03(2014) Standard
Test Method for Volume Nonvolatile Matter in Clear or Pigmented
Coatings (incorporated by reference, see Sec. 63.14) or ASTM D6093-97
(2016) Standard Test Method for Percent Volume Nonvolatile Matter in
Clear or Pigmented Coatings Using a Helium Gas Pycnometer (incorporated
by reference, see Sec. 63.14), or an EPA approved alternative method.
You must determine the density of each coating using ASTM D1475-13
``Standard Test Method for Density of Liquid Coatings, Inks, and
Related Products'' (incorporated by reference, see Sec. 63.14) or ASTM
D2111-10 (2015) ``Standard Test Methods for Specific Gravity and
Density of Halogenated Organic Solvents and Their Admixtures''
(incorporated by reference, see Sec. 63.14). The solids determination
using ASTM D2697-03(2014) or ASTM D6093-97 (2016) and the density
determination using ASTM D1475-13 or ASTM 2111-10 (2015) may be
performed by the manufacturer of the material and the results provided
to you. Alternatively, you may rely on formulation data provided by
material providers to determine the volume solids. In the event of any
inconsistency between test data obtained with the ASTM test methods
specified in this section and formulation data, the test data will
govern.
(d) Control device destruction or removal efficiency. If you are
using an add-on control device, such as an oxidizer, to comply with the
standard in Sec. 63.5120, you must conduct performance tests according
to Table 1 to Sec. 63.5160 to establish the destruction or removal
efficiency of the control device or the outlet HAP concentration
achieved by the oxidizer, according to the methods and procedures in
paragraphs (d)(1) and (2) of this section. During performance tests,
you must establish the operating limits required by Sec. 63.5121
according to paragraph (d)(3) of this section.
(1) Performance tests conducted to determine the destruction or
removal efficiency of the control device must be performed such that
control device inlet and outlet testing is conducted simultaneously. To
determine the outlet organic HAP concentration achieved by the
oxidizer, only oxidizer outlet testing must be conducted. The data must
be reduced in accordance with the test methods and procedures in
paragraphs (d)(1)(i) through (ix).
* * * * *
(vi) Method 25 or 25A in appendix A-7 of part 60 is used to
determine total gaseous non-methane organic matter concentration. You
may use Method 18 in appendix A-6 of part 60 to subtract methane
emissions from measured total gaseous organic mass emissions as carbon.
Use the same test method for both the inlet and outlet measurements,
which must be conducted simultaneously. You must submit notification of
the intended test method to the Administrator for approval along with
notification of the performance test required under Sec. 63.7 (b). You
must use Method 25A if any of the conditions described in paragraphs
(d)(1)(vi)(A) through (D) of this section apply to the control device.
* * * * *
(vii) Each performance test must consist of three separate runs,
except as provided by Sec. 63.7(e)(3); each run must be conducted for
at least 1 hour under the conditions that exist when the affected
source is operating under normal operating conditions. For the purpose
of determining volatile organic matter concentrations and mass flow
rates, the average of the results of all runs will apply. If you are
demonstrating compliance with the outlet organic HAP concentration
limit in Sec. 63.5120(a)(3), only the average outlet volatile organic
matter concentration must be determined.
* * * * *
(2) You must record such process information as may be necessary to
determine the conditions in existence at the time of the performance
test. Before August 24, 2020, operations during periods of start-up,
shutdown, and
[[Page 10864]]
malfunction will not constitute representative conditions for the
purpose of a performance test. On and after August 24, 2020, you must
conduct the performance test under representative operating conditions
for the coating operation. Operations during periods of start-up,
shutdown, or nonoperation do not constitute representative conditions
for the purpose of a performance test. The owner or operator may not
conduct performance tests during periods of malfunction. You must
record the process information that is necessary to document operating
conditions during the test and explain why the conditions represent
normal operation. Upon request, you must make available to the
Administrator such records as may be necessary to determine the
conditions of performance tests.
(3) Operating limits. If you are using a capture system and add-on
control device other than a solvent recovery system for which you
conduct a liquid-liquid material balance to comply with the
requirements in Sec. 63.5120, you must establish the applicable
operating limits required by Sec. 63.5121. These operating limits
apply to each capture system and to each add-on emission control device
that is not monitored by CEMS, and you must establish the operating
limits during performance tests required by paragraph (d) of this
section according to the requirements in paragraphs (d)(3)(i) through
(iii) of this section.
(i) * * *
(A) During performance tests, you must monitor and record the
combustion temperature at least once every 15 minutes during each of
the three test runs. You must monitor the temperature in the firebox of
the thermal oxidizer or immediately downstream of the firebox before
any substantial heat exchange occurs.
* * * * *
(ii) * * *
(D) You must develop and implement an inspection and maintenance
plan for your catalytic oxidizer(s) for which you elect to monitor
according to paragraph (d)(3)(ii)(C) of this section. The plan must
address, at a minimum, the elements specified in paragraphs
(d)(3)(ii)(D) (1) through (3) of this section.
* * * * *
(e) Capture efficiency. If you are required to determine capture
efficiency to meet the requirements of Sec. 63.5170(e)(2), (f)(1) and
(2), (g)(2) through (4), or (i)(2) and (3), you must determine capture
efficiency using the procedures in paragraph (e)(1), (2), or (3) of
this section, as applicable.
* * * * *
0
35. Section 63.5170 is amended by revising Table 1 and paragraphs
(c)(1) and (2), (c)(4) introductory text, (e)(2) introductory text,
(f)(1) introductory text, (f)(2), (g)(2) introductory text, (g)(3)
introductory text, (g)(4) introductory text, Equation 11 of paragraph
(h)(6), (i) introductory text, and (i)(1) to read as follows:
Sec. 63.5170 How do I demonstrate compliance with the standards?
* * * * *
Table 1 to Sec. 63.5170--Compliance Demonstration Requirements Index
------------------------------------------------------------------------
If you choose to demonstrate
compliance by: Then you must demonstrate that:
------------------------------------------------------------------------
1. Use of ``as purchased'' a. Each coating material used during
compliant coatings. the 12-month compliance period does
not exceed 0.046 kg HAP per liter
solids, as purchased. Paragraph (a)
of this section.
2. Use of ``as applied'' compliant a. Each coating material used does
coatings. not exceed 0.046 kg HAP per liter
solids on a rolling 12-month
average as applied basis,
determined monthly. Paragraphs
(b)(1) of this section; or
b. Average of all coating materials
used does not exceed 0.046 kg HAP
per liter solids on a rolling 12-
month average as applied basis,
determined monthly. Paragraph
(b)(2) of this section.
3. Use of a capture system and Overall organic HAP control
control device. efficiency is at least 98 percent
on a monthly basis for individual
or groups of coil coating lines; or
overall organic HAP control
efficiency is at least 98 percent
during performance tests conducted
according to Table 1 to Sec.
63.5170 and operating limits are
achieved continuously for
individual coil coating lines; or
oxidizer outlet HAP concentration
is no greater than 20 ppmv and
there is 100-percent capture
efficiency during performance tests
conducted according to Table 1 to
Sec. 63.5170 and operating limits
are achieved continuously for
individual coil coating lines.
Paragraph (c) of this section.
4. Use of a combination of Average equivalent emission rate
compliant coatings and control does not exceed 0.046 kg HAP per
devices and maintaining an liter solids on a rolling 12-month
acceptable equivalent emission average as applied basis,
rate. determined monthly. Paragraph (d)
of this section.
------------------------------------------------------------------------
* * * * *
(c) * * *
(1) If the affected source uses one compliance procedure to limit
organic HAP emissions to the level specified in Sec. 63.5120(a)(1) or
(3) and has only always-controlled work stations, then you must
demonstrate compliance with the provisions of paragraph (e) of this
section when emissions from the affected source are controlled by one
or more solvent recovery devices.
(2) If the affected source uses one compliance procedure to limit
organic HAP emissions to the level specified in Sec. 63.5120(a)(1) or
(3) and has only always-controlled work stations, then you must
demonstrate compliance with the provisions of paragraph (f) of this
section when emissions are controlled by one or more oxidizers.
* * * * *
(4) The method of limiting organic HAP emissions to the level
specified in Sec. 63.5120(a)(3) is the installation and operation of a
PTE around each work station and associated curing oven in the coating
line and the ventilation of all organic HAP emissions from each PTE to
an oxidizer with an outlet organic HAP concentration of no greater than
20 ppmv on a dry basis. An enclosure that meets the requirements in
Sec. 63.5160(e)(1) is considered a PTE. Compliance of the oxidizer
with the outlet organic HAP concentration limit is demonstrated either
through continuous emission monitoring according to paragraph
(c)(4)(ii) of this section or through performance tests according to
the requirements of Sec. 63.5160(d) and Table 1 to Sec. 63.5160. If
this method is selected, you must meet the requirements of paragraph
(c)(4)(i) of this section to demonstrate continuing achievement of 100
percent capture of organic HAP emissions and either paragraph
(c)(4)(ii) or paragraph (c)(4)(iii) of this section, respectively, to
demonstrate continuous compliance with the oxidizer outlet organic HAP
concentration limit through continuous
[[Page 10865]]
emission monitoring or continuous operating parameter monitoring:
* * * * *
(e) * * *
(2) Continuous emission monitoring of control device performance.
Use continuous emission monitors to demonstrate recovery efficiency,
conduct performance tests of capture efficiency and volumetric flow
rate, and continuously monitor a site specific operating parameter to
ensure that capture efficiency and volumetric flow rate are maintained
following the procedures in paragraphs (e)(2)(i) through (xi) of this
section:
* * * * *
(f) * * *
(1) Continuous monitoring of capture system and control device
operating parameters. Demonstrate compliance through performance tests
of capture efficiency and control device efficiency and continuous
monitoring of capture system and control device operating parameters as
specified in paragraphs (f)(1)(i) through (xi) of this section:
* * * * *
(2) Continuous emission monitoring of control device performance.
Use continuous emission monitors, conduct performance tests of capture
efficiency, and continuously monitor a site specific operating
parameter to ensure that capture efficiency is maintained. Compliance
must be demonstrated in accordance with paragraph (e)(2) of this
section.
(g) * * *
(2) Solvent recovery system using performance test and continuous
monitoring compliance demonstration. For each solvent recovery system
used to control one or more coil coating stations for which you choose
to comply by means of performance testing of capture efficiency,
continuous emission monitoring of the control device, and continuous
monitoring of a capture system operating parameter, each month of the
12-month compliance period you must meet the requirements of paragraphs
(g)(2)(i) and (ii) of this section:
* * * * *
(3) Oxidizer using performance tests and continuous monitoring of
operating parameters compliance demonstration. For each oxidizer used
to control emissions from one or more work stations for which you
choose to demonstrate compliance through performance tests of capture
efficiency, control device efficiency, and continuous monitoring of
capture system and control device operating parameters, each month of
the 12-month compliance period you must meet the requirements of
paragraphs (g)(3)(i) through (iii) of this section:
* * * * *
(4) Oxidizer using continuous emission monitoring compliance
demonstration. For each oxidizer used to control emissions from one or
more work stations for which you choose to demonstrate compliance
through capture efficiency testing, continuous emission monitoring of
the control device, and continuous monitoring of a capture system
operating parameter, each month of the 12-month compliance period you
must meet the requirements in paragraphs (g)(4)(i) and (ii) of this
section:
* * * * *
(h) * * *
(6) * * *
[GRAPHIC] [TIFF OMITTED] TR25FE20.001
* * * * *
(i) Capture and control system compliance demonstration procedures
using a CPMS for a coil coating line. If you use an add-on control
device, to demonstrate compliance for each capture system and each
control device through performance tests and continuous monitoring of
capture system and control device operating parameters, you must meet
the requirements in paragraphs (i)(1) through (3) of this section.
(1) Conduct performance tests according to the schedule in Table 1
to Sec. 63.5160 to determine the control device destruction or removal
efficiency, DRE, according to Sec. 63.5160(d) and Table 1 to Sec.
63.5160.
* * * * *
0
36. Section 63.5180 is amended by:
0
a. Revising paragraphs (f) introductory text and (f)(1);
0
b. Removing and reserving paragraph (f)(2);
0
c. Revising paragraphs (g)(2)(v), (h) introductory text, (h)(2) and
(3);
0
d. Adding paragraph (h)(4); and
0
e. Revising paragraphs (i) introductory text, (i)(1) through (4),
(i)(6), and (i)(9).
The revisions and addition read as follows:
Sec. 63.5180 What reports must I submit?
* * * * *
(f) Before August 24, 2020, you must submit start-up, shutdown, and
malfunction reports as specified in Sec. 63.10(d)(5) if you use a
control device to comply with this subpart.
(1) Before August 24, 2020, if your actions during a start-up,
shutdown, or malfunction of an affected source (including actions taken
to correct a malfunction) are not completely consistent with the
procedures specified in the source's start-up, shutdown, and
malfunction plan specified in Sec. 63.6 (e)(3) and required before
August 24, 2020, you must state such information in the report. The
start-up, shutdown, or malfunction report will consist of a letter
containing the name, title, and signature of the responsible official
who is certifying its accuracy, that will be submitted to the
Administrator. Separate start-up, shutdown, or malfunction reports are
not required if the information is included in the report specified in
paragraph (g) of this section. The start-up, shutdown, and malfunction
plan and start-up, shutdown, and malfunction report are no longer
required on and after August 24, 2020.
* * * * *
(g) * * *
(2) * * *
(v) A statement that there were no deviations from the applicable
emission limit in Sec. 63.5120 or the applicable operating limit(s)
established according to Sec. 63.5121 during the reporting period, and
that no CEMS were inoperative, inactive, malfunctioning, out-of-
control, repaired, or adjusted.
(h) You must submit, for each deviation occurring at an affected
source where you are not using CEMS to comply with the standards in
this subpart, the semi-annual compliance report containing the
information in paragraphs (g)(2)(i) through (iv) of this section and
the information in paragraphs (h)(1) through (4) of this section:
* * * * *
(2) Before August 24, 2020, you must provide information on the
number, duration, and cause of deviations
[[Page 10866]]
(including unknown cause, if applicable) as applicable, and the
corrective action taken. On and after August 24, 2020, you must provide
information on the number, date, time, duration, and cause of
deviations from an emission limit in Sec. 63.5120 or any applicable
operating limit established according to Sec. 63.5121 (including
unknown cause, if applicable) as applicable, and the corrective action
taken.
(3) Before August 24, 2020, you must provide information on the
number, duration, and cause for continuous parameter monitoring system
downtime incidents (including unknown cause other than downtime
associated with zero and span and other daily calibration checks, if
applicable). On and after August 24, 2020, you must provide the
information specified in paragraphs (h)(3)(i) and (ii) of this section.
(i) Number, date, time, duration, cause (including unknown cause),
and descriptions of corrective actions taken for continuous parameter
monitoring systems that are inoperative (except for zero (low-level)
and high-level checks).
(ii) Number, date, time, duration, cause (including unknown cause),
and descriptions of corrective actions taken for continuous parameter
monitoring systems that are out of control as specified in Sec.
63.8(c)(7).
(4) On and after August 24, 2020, for each deviation from an
emission limit in Sec. 63.5120 or any applicable operating limit
established according to Sec. 63.5121, you must provide a list of the
affected source or equipment, an estimate of the quantity of each
regulated pollutant emitted over any emission limit in Sec. 63.5120, a
description of the method used to estimate the emissions, and the
actions you took to minimize emissions in accordance with Sec.
63.5140(b).
(i) You must submit, for each deviation from the applicable
emission limit in Sec. 63.5120 or the applicable operation limit(s)
established according to Sec. 63.5121 occurring at an affected source
where you are using CEMS to comply with the standards in this subpart,
the semi-annual compliance report containing the information in
paragraphs (g)(2)(i) through (iv) of this section, and the information
in paragraphs (i)(1) through (12) of this section:
(1) The date and time that each malfunction of the capture system
or add-on control devices started and stopped.
(2) Before August 24, 2020, the date and time that each CEMS was
inoperative, except for zero (low-level) and high-level checks. On and
after August 24, 2020, for each instance that the CEMS was inoperative,
except for zero (low-level) and high-level checks, the date, time, and
duration that the CEMS was inoperative; the cause (including unknown
cause) for the CEMS being inoperative; and a description of corrective
actions taken.
(3) Before August 24, 2020, the date and time that each CEMS was
out-of-control, including the information in Sec. 63.8(c)(8). On and
after August 24, 2020, for each instance that the CEMS was out-of-
control, as specified in Sec. 63.8(c)(7), the date, time, and duration
that the CEMS was out-of-control; the cause (including unknown cause)
for the CEMS being out-of-control; and descriptions of corrective
actions taken.
(4) Before August 24, 2020, the date and time that each deviation
started and stopped, and whether each deviation occurred during a
period of start-up, shutdown, or malfunction or during another period.
On and after August 24, 2020, the date, time, and duration of each
deviation from an emission limit in Sec. 63.5120. For each deviation,
an estimate of the quantity of each regulated pollutant emitted over
any emission limit in Sec. 63.5120 to this subpart, and a description
of the method used to estimate the emissions.
* * * * *
(6) Before August 24, 2020, a breakdown of the total duration of
the deviations during the reporting period into those that are due to
start-up, shutdown, control equipment problems, process problems, other
known causes, and other unknown causes. On and after August 24, 2020, a
breakdown of the total duration of the deviations during the reporting
period into those that are due to control equipment problems, process
problems, other known causes, and other unknown causes.
* * * * *
(9) Before August 24, 2020, a brief description of the metal coil
coating line. On and after August 24, 2020, a list of the affected
source or equipment, including a brief description of the metal coil
coating line.
* * * * *
0
37. Section 63.5181 is added to read as follows:
Sec. 63.5181 What are my electronic reporting requirements?
(a) Beginning no later than August 24, 2020, you must submit the
results of each performance test as required in Sec. 63.5180(e)
following the procedure specified in paragraphs (a)(1) through (3) of
this section.
(1) For data collected using test methods supported by the EPA's
Electronic Reporting Tool (ERT) as listed on the EPA's ERT website
(https://www.epa.gov/electronic-reporting-air-emissions/electronic-reporting-tool-ert) at the time of the test, you must submit the
results of the performance test to the EPA via the Compliance and
Emissions Data Reporting Interface (CEDRI). The CEDRI interface can be
accessed through the EPA's Central Data Exchange (CDX) (https://cdx.epa.gov/). Performance test data must be submitted in a file format
generated through the use of the EPA's ERT or an alternate electronic
file format consistent with the extensible markup language (XML) schema
listed on the EPA's ERT website.
(2) For data collected using test methods that are not supported by
the EPA's ERT as listed on the EPA's ERT website at the time of the
test, you must submit the results of the performance test in portable
document format (PDF) using the attachment module of the ERT.
(3) If you claim that some of the performance test information
being submitted under paragraph (a)(1) of this section is confidential
business information (CBI), you must submit a complete file generated
through the use of the EPA's ERT or an alternate electronic file
consistent with the XML schema listed on the EPA's ERT website,
including information claimed to be CBI, on a compact disc, flash drive
or other commonly used electronic storage medium to the EPA. The
electronic medium must be clearly marked as CBI and mailed to U.S. EPA/
OAQPS/CORE CBI Office, Attention: Group Leader, Measurement Policy
Group, MD C404-02, 4930 Old Page Rd., Durham, NC 27703. The same ERT or
alternate file with the CBI omitted must be submitted to the EPA via
the EPA's CDX as described in paragraph (a)(1) of this section.
(b) Beginning on August 24, 2020, the owner or operator shall
submit the initial notifications required in Sec. 63.9(b) and the
notification of compliance status required in Sec. Sec. 63.9(h) and
63.5180(d) to the EPA via the CEDRI. The CEDRI interface can be
accessed through the EPA's CDX (https://cdx.epa.gov). The owner or
operator must upload to CEDRI an electronic copy of each applicable
notification in PDF. The applicable notification must be submitted by
the deadline specified in this subpart, regardless of the method in
which the reports are submitted. Owners or operators who claim that
some of the information required to be submitted via CEDRI is CBI shall
submit a complete report generated using the appropriate form in CEDRI
or an
[[Page 10867]]
alternate electronic file consistent with the XML schema listed on the
EPA's CEDRI website, including information claimed to be CBI, on a
compact disc, flash drive, or other commonly used electronic storage
medium to the EPA. The electronic medium shall be clearly marked as CBI
and mailed to U.S. EPA/OAQPS/CORE CBI Office, Attention: Group Leader,
Measurement Policy Group, MD C404-02, 4930 Old Page Rd., Durham, NC
27703. The same file with the CBI omitted shall be submitted to the EPA
via the EPA's CDX as described earlier in this paragraph.
(c) Beginning on March 25, 2021, or once the reporting template has
been available on the CEDRI website for 1 year, whichever date is
later, the owner or operator shall submit the semiannual compliance
report required in Sec. 63.5180(g) through (i), as applicable, to the
EPA via the CEDRI. The CEDRI interface can be accessed through the
EPA's CDX (https://cdx.epa.gov). The owner or operator must use the
appropriate electronic template on the CEDRI website for this subpart
(https://www.epa.gov/electronic-reporting-air-emissions/compliance-and-emissions-data-reporting-interface-cedri). The date on which the report
templates become available will be listed on the CEDRI website. If the
reporting form for the semiannual compliance report specific to this
subpart is not available in CEDRI at the time that the report is due,
you must submit the report to the Administrator at the appropriate
addresses listed in Sec. 63.13. Once the form has been available in
CEDRI for 1 year, you must begin submitting all subsequent reports via
CEDRI. The reports must be submitted by the deadlines specified in this
subpart, regardless of the method in which the reports are submitted.
Owners or operators who claim that some of the information required to
be submitted via CEDRI is CBI shall submit a complete report generated
using the appropriate form in CEDRI, including information claimed to
be CBI, on a compact disc, flash drive, or other commonly used
electronic storage medium to the EPA. The electronic medium shall be
clearly marked as CBI and mailed to U.S. EPA/OAQPS/CORE CBI Office,
Attention: Group Leader, Measurement Policy Group, MD C404-02, 4930 Old
Page Rd., Durham, NC 27703. The same file with the CBI omitted shall be
submitted to the EPA via the EPA's CDX as described earlier in this
paragraph.
(d) If you are required to electronically submit a report through
the CEDRI in the EPA's CDX, you may assert a claim of EPA system outage
for failure to timely comply with the reporting requirement. To assert
a claim of EPA system outage, you must meet the requirements outlined
in paragraphs (g)(1) through (7) of this section.
(1) You must have been or will be precluded from accessing CEDRI
and submitting a required report within the time prescribed due to an
outage of either the EPA's CEDRI or CDX systems.
(2) The outage must have occurred within the period of time
beginning five business days prior to the date that the submission is
due.
(3) The outage may be planned or unplanned.
(4) You must submit notification to the Administrator in writing as
soon as possible following the date you first knew, or through due
diligence should have known, that the event may cause or caused a delay
in reporting.
(5) You must provide to the Administrator a written description
identifying:
(i) The date(s) and time(s) when CDX or CEDRI was accessed and the
system was unavailable;
(ii) A rationale for attributing the delay in reporting beyond the
regulatory deadline to the EPA system outage;
(iii) Measures taken or to be taken to minimize the delay in
reporting; and
(iv) The date by which you propose to report, or if you have
already met the reporting requirement at the time of the notification,
the date you reported.
(6) The decision to accept the claim of EPA system outage and allow
an extension to the reporting deadline is solely within the discretion
of the Administrator.
(7) In any circumstance, the report must be submitted
electronically as soon as possible after the outage is resolved.
(e) If you are required to electronically submit a report through
CEDRI in the EPA's CDX, you may assert a claim of force majeure for
failure to timely comply with the reporting requirement. To assert a
claim of force majeure, you must meet the requirements outlined in
paragraphs (h)(1) through (5) of this section.
(1) You may submit a claim if a force majeure event is about to
occur, occurs, or has occurred or there are lingering effects from such
an event within the period of time beginning five business days prior
to the date the submission is due. For the purposes of this section, a
force majeure event is defined as an event that will be or has been
caused by circumstances beyond the control of the affected facility,
its contractors, or any entity controlled by the affected facility that
prevents you from complying with the requirement to submit a report
electronically within the time period prescribed. Examples of such
events are acts of nature (e.g., hurricanes, earthquakes, or floods),
acts of war or terrorism, or equipment failure or safety hazard beyond
the control of the affected facility (e.g., large scale power outage).
(2) You must submit notification to the Administrator in writing as
soon as possible following the date you first knew, or through due
diligence should have known, that the event may cause or has caused a
delay in reporting.
(3) You must provide to the Administrator:
(i) A written description of the force majeure event;
(ii) A rationale for attributing the delay in reporting beyond the
regulatory deadline to the force majeure event;
(iii) Measures taken or to be taken to minimize the delay in
reporting; and
(iv) The date by which you propose to report, or if you have
already met the reporting requirement at the time of the notification,
the date you reported.
(4) The decision to accept the claim of force majeure and allow an
extension to the reporting deadline is solely within the discretion of
the Administrator.
(5) In any circumstance, the reporting must occur as soon as
possible after the force majeure event occurs.
0
38. Section 63.5190 is amended by adding paragraphs (a)(5) and (c) to
read as follows:
Sec. 63.5190 What records must I maintain?
(a) * * *
(5) On and after August 24, 2020, for each deviation from an
emission limitation reported under Sec. 63.5180(h) or (i), a record of
the information specified in paragraphs (a)(5)(i) through (iv) of this
section, as applicable.
(i) The date, time, and duration of the deviation, as reported
under Sec. 63.5180(h) and (i).
(ii) A list of the affected sources or equipment for which the
deviation occurred and the cause of the deviation, as reported under
Sec. 63.5180(h) and (i).
(iii) An estimate of the quantity of each regulated pollutant
emitted over any applicable emission limit in Sec. 63.5120 to this
subpart or any applicable operating limit established according to
Sec. 63.5121 to this subpart, and a description of the method used to
calculate the estimate, as reported under Sec. 63.5180(h) and (i).
(iv) A record of actions taken to minimize emissions in accordance
with Sec. 63.5140(b) and any corrective actions taken to return the
affected unit to its normal or usual manner of operation.
* * * * *
[[Page 10868]]
(c) Any records required to be maintained by this subpart that are
in reports that were submitted electronically via the EPA's CEDRI may
be maintained in electronic format. This ability to maintain electronic
copies does not affect the requirement for facilities to make records,
data, and reports available upon request to a delegated air agency or
the EPA as part of an on-site compliance evaluation.
0
39. Table 2 to subpart SSSS of part 63 is revised to read as follows:
Table 2 to Subpart SSSS of Part 63--Applicability of General
Provisions to Subpart SSSS
You must comply with the applicable General Provisions requirements
according to the following table:
----------------------------------------------------------------------------------------------------------------
Applicable to subpart
General provisions reference Subject SSSS Explanation
----------------------------------------------------------------------------------------------------------------
Sec. 63.1(a)(1)-(4)................ General Applicability.. Yes....................
Sec. 63.1(a)(6).................... Source Category Listing Yes....................
Sec. 63.1(a)(10)-(12).............. Timing and Overlap Yes....................
Clarifications.
Sec. 63.1(b)(1).................... Initial Applicability Yes.................... Applicability to
Determination. Subpart SSSS is also
specified in Sec.
63.5090.
Sec. 63.1(b)(3).................... Applicability Yes....................
Determination
Recordkeeping.
Sec. 63.1(c)(1).................... Applicability after Yes....................
Standard Established.
Sec. 63.1(c)(2).................... Applicability of Permit Yes....................
Program for Area
Sources.
Sec. 63.1(c)(5).................... Extensions and Yes....................
Notifications.
Sec. 63.1(e)....................... Applicability of Permit Yes....................
Program Before
Relevant Standard is
Set.
Sec. 63.2.......................... Definitions............ Yes.................... Additional definitions
are specified in Sec.
63.5110.
Sec. 63.3.......................... Units and Abbreviations Yes....................
Sec. 63.4(a)(1)-(2)................ Prohibited Activities.. Yes....................
Sec. 63.4(b)-(c)................... Circumvention/ Yes....................
Fragmentation.
Sec. 63.5(a)....................... Construction/ Yes....................
Reconstruction.
Sec. 63.5(b)(1), (3), (4), (6)..... Requirements for Yes....................
Existing, Newly
Constructed, and
Reconstructed Sources.
Sec. 63.5(d)(1)(i)-(ii)(F), Application for Yes.................... Only total HAP
(d)(1)(ii)(H), (d)(1)(ii)(J), Approval of emissions in terms of
(d)(1)(iii), (d)(2)-(4). Construction/ tons per year are
Reconstruction. required for Sec.
63.5(d)(1)(ii)(H).
Sec. 63.5(e)....................... Approval of Yes....................
Construction/
Reconstruction.
Sec. 63.5(f)....................... Approval of Yes....................
Construction/
Reconstruction Based
on Prior State Review.
Sec. 63.6(a)....................... Compliance with Yes....................
Standards and
Maintenance
Requirements-
Applicability.
Sec. 63.6(b)(1)-(5), (b)(7)........ Compliance Dates for Yes.................... Section 63.5130
New and Reconstructed specifies the
Sources. compliance dates.
Sec. 63.6(c)(1), (2), (5).......... Compliance Dates for Yes.................... Section 63.5130
Existing Sources. specifies the
compliance dates.
Sec. 63.6(e)(1)(i)-(ii)............ General Duty to Yes before August 24, See Sec. 63.5140(b)
Minimize Emissions and 2020, No on and after for general duty
Requirement to Correct August 24, 2020. requirement.
Malfunctions As Soon
As Possible.
Sec. 63.6(e)(1)(iii)............... Operation and Yes....................
Maintenance
Requirements.
Sec. 63.6(e)(3)(i), (e)(3)(iii)- SSMP Requirements...... Yes before August 24,
(ix). 2020, No on and after
August 24, 2020.
Sec. 63.6(f)(1).................... SSM Exemption.......... Yes before August 24, See Sec. 63.5140(b)
2020, No on and after for general duty
August 24, 2020. requirement.
Sec. 63.6(f)(2)-(3)................ Compliance with Non- Yes....................
Opacity Emission
Standards.
Sec. 63.6(g)....................... Alternative Non-Opacity Yes....................
Emission Standard.
Sec. 63.6(h)....................... Compliance with Opacity/ No..................... Subpart SSSS does not
Visible Emission establish opacity
Standards. standards or visible
emission standards.
Sec. 63.6(i)(1)-(14), (i)(16)...... Extension of Compliance Yes....................
and Administrator's
Authority.
Sec. 63.6(j)....................... Presidential Compliance Yes....................
Exemption.
Sec. 63.7(a)-(d) except (a)(2)(i)- Performance Test Yes....................
(viii). Requirements.
Sec. 63.7(e)(1).................... Performance Testing.... Yes before August 24, See Sec.
2020, No on and after 63.5160(d)(2).
August 24, 2020.
Sec. 63.7(e)(2)-(4)................ Conduct of Performance Yes....................
Tests.
Sec. 63.7(f)....................... Alternative Test Method Yes.................... EPA retains approval
authority.
[[Page 10869]]
Sec. 63.7(g)-(h)................... Data Analysis and Yes....................
Waiver of Tests.
Sec. 63.8(a)(1)-(2)................ Monitoring Yes.................... Additional requirements
Requirements--Applicab for monitoring are
ility. specified in Sec.
63.5150(a).
Sec. 63.8(a)(4).................... Additional Monitoring No..................... Subpart SSSS does not
Requirements. have monitoring
requirements for
flares.
Sec. 63.8(b)....................... Conduct of Monitoring.. Yes....................
Sec. 63.8(c)(1).................... Operation and Yes before August 24, Section 63.5150(a)
Maintenance of 2020, No on and after specifies the
Continuous Monitoring August 24, 2020. requirements for the
System (CMS). operation of CMS for
capture systems and
add-on control devices
at sources using these
to comply.
Sec. 63.8(c)(2)-(3)................ CMS Operation and Yes.................... Applies only to
Maintenance. monitoring of capture
system and add-on
control device
efficiency at sources
using these to comply
with the standards.
Additional
requirements for CMS
operations and
maintenance are
specified in Sec.
63.5170.
Sec. 63.8(c)(4)-(5)................ CMS Continuous No..................... Subpart SSSS does not
Operation Procedures. require COMS.
Sec. 63.8(c)(6)-(8)................ CMS Requirements....... Yes.................... Provisions only apply
if CEMS are used.
Sec. 63.8(d)-(e)................... CMS Quality Control, Yes.................... Provisions only apply
Written Procedures, if CEMS are used.
and Performance
Evaluation.
Sec. 63.8(f)(1)-(5)................ Use of an Alternative Yes.................... EPA retains approval
Monitoring Method. authority.
Sec. 63.8(f)(6).................... Alternative to Relative No..................... Section 63.8(f)(6)
Accuracy Test. provisions are not
applicable because
subpart SSSS does not
require CEMS.
Sec. 63.8(g)....................... Data Reduction......... No..................... Sections 63.5170,
63.5140, 63.5150, and
63.5150 specify
monitoring data
reduction.
Sec. 63.9(a)....................... Notification of Yes....................
Applicability.
Sec. 63.9(b)(1).................... Initial Notifications.. Yes....................
Sec. 63.9(b)(2).................... Initial Notifications.. Yes.................... With the exception that
Sec. 63.5180(b)(1)
provides 2 years after
the proposal date for
submittal of the
initial notification
for existing sources.
Sec. 63.9(b)(4)(i), (b)(4)(v), Application for Yes....................
(b)(5). Approval of
Construction or
Reconstruction.
Sec. 63.9(c)-(e)................... Request for Extension Yes.................... Notification of
of Compliance, New performance test
Source Notification requirement applies
for Special Compliance only to capture system
Requirements, and and add-on control
Notification of device performance
Performance Test. tests at sources using
these to comply with
the standards.
Sec. 63.9(f)....................... Notification of Visible No..................... Subpart SSSS does not
Emissions/Opacity Test. require opacity and
visible emissions
observations.
Sec. 63.9(g)....................... Additional No..................... Provisions for COMS are
Notifications When not applicable.
Using CMS.
Sec. 63.9(h)(1)-(3)................ Notification of Yes.................... Section 63.5130
Compliance Status. specifies the dates
for submitting the
notification of
compliance status.
Sec. 63.9(h)(5)-(6)................ Clarifications......... Yes....................
Sec. 63.9(i)....................... Adjustment of Submittal Yes....................
Deadlines.
Sec. 63.9(j)....................... Change in Previous Yes....................
Information.
Sec. 63.10(a)...................... Recordkeeping/ Yes....................
Reporting--Applicabili
ty and General
Information.
Sec. 63.10(b)(1)................... General Recordkeeping Yes.................... Additional requirements
Requirements. are specified in Sec.
63.5190.
Sec. 63.10(b)(2)(i)-(ii)........... Recordkeeping of Yes before August 24, See Sec.
Occurrence and 2020, No on and after 63.5190(a)(5).
Duration of Startups August 24, 2020.
and Shutdowns and
Recordkeeping of
Failures to Meet
Standards.
Sec. 63.10(b)(2)(iii).............. Maintenance Records.... Yes....................
[[Page 10870]]
Sec. 63.10(b)(2)(iv)-(v)........... Actions Taken to Yes before August 24, See Sec.
Minimize Emissions 2020, No on and after 63.5190(a)(5).
During Startup, August 24, 2020.
Shutdown, and
Malfunction.
Sec. 63.10(b)(2)(vi)............... Recordkeeping for CMS Yes before August 24, See Sec.
Malfunctions. 2020, No on and after 63.5190(a)(5).
August 24, 2020.
Sec. 63.10(b)(2)(vii)-(xiv)........ Other CMS Requirements. Yes....................
Sec. 63.10(b)(3)................... Recordkeeping Yes....................
Requirements for
Applicability
Determinations.
Sec. 63.10(c)...................... Additional CMS No..................... See Sec.
Recordkeeping 63.5190(a)(5).
Requirements.
Sec. 63.10(d)(1)-(2)............... General Reporting Yes.................... Additional requirements
Requirements and are specified in Sec.
Report of Performance 63.5180(e).
Test Results.
Sec. 63.10(d)(3)................... Reporting Opacity or No..................... Subpart SSSS does not
Visible Emissions require opacity and
Observations. visible emissions
observations.
Sec. 63.10(d)(4)................... Progress Reports for Yes....................
Sources with
Compliance Extensions.
Sec. 63.10(d)(5)................... Startup, Shutdown, Yes before August 24,
Malfunction Reports. 2020, No on and after
August 24, 2020.
Sec. 63.10(e)...................... Additional Reporting No.....................
Requirements for
Sources with CMS.
Sec. 63.10(f)...................... Recordkeeping/Reporting Yes....................
Waiver.
Sec. 63.11......................... Control Device No..................... Subpart SSSS does not
Requirements/Flares. specify use of flares
for compliance.
Sec. 63.12......................... State Authority and Yes....................
Delegations.
Sec. 63.13(a)...................... Addresses.............. Yes before August 24,
2020, No on and after
August 24, 2020.
Sec. 63.13(b)...................... Submittal to State Yes....................
Agencies.
Sec. 63.13(c)...................... Submittal to State Yes before August 24,
Agencies. 2020, No unless the
state requires the
submittal via CEDRI,
on and after August
24, 2020.
Sec. 63.14......................... Incorporation by Yes.................... Subpart SSSS includes
Reference. provisions for
alternative ASTM and
ASME test methods that
are incorporated by
reference.
Sec. 63.15......................... Availability of Yes....................
Information/
Confidentiality.
----------------------------------------------------------------------------------------------------------------
0
40. Table 3 to subpart SSSS of part 63 is added to read as follows:
Table 3 to Subpart SSSS of Part 63--List of Hazardous Air Pollutants
That Must Be Counted Toward Total Organic HAP Content if Present at 0.1
Percent or More by Mass
------------------------------------------------------------------------
Chemical name CAS No.
------------------------------------------------------------------------
1,1,2,2-Tetrachloroethane............................ 79-34-5
1,1,2-Trichloroethane................................ 79-00-5
1,1-Dimethylhydrazine................................ 57-14-7
1,2-Dibromo-3-chloropropane.......................... 96-12-8
1,2-Diphenylhydrazine................................ 122-66-7
1,3-Butadiene........................................ 106-99-0
1,3-Dichloropropene.................................. 542-75-6
1,4-Dioxane.......................................... 123-91-1
2,4,6-Trichlorophenol................................ 88-06-2
2,4/2,6-Dinitrotoluene (mixture)..................... 25321-14-6
2,4-Dinitrotoluene................................... 121-14-2
2,4-Toluene diamine.................................. 95-80-7
2-Nitropropane....................................... 79-46-9
3,3'-Dichlorobenzidine............................... 91-94-1
3,3'-Dimethoxybenzidine.............................. 119-90-4
3,3'-Dimethylbenzidine............................... 119-93-7
4,4'-Methylene bis(2-chloroaniline).................. 101-14-4
Acetaldehyde......................................... 75-07-0
Acrylamide........................................... 79-06-1
Acrylonitrile........................................ 107-13-1
Allyl chloride....................................... 107-05-1
alpha-Hexachlorocyclohexane (a-HCH).................. 319-84-6
Aniline.............................................. 62-53-3
Benzene.............................................. 71-43-2
[[Page 10871]]
Benzidine............................................ 92-87-5
Benzotrichloride..................................... 98-07-7
Benzyl chloride...................................... 100-44-7
beta-Hexachlorocyclohexane (b-HCH)................... 319-85-7
Bis(2-ethylhexyl)phthalate........................... 117-81-7
Bis(chloromethyl)ether............................... 542-88-1
Bromoform............................................ 75-25-2
Captan............................................... 133-06-2
Carbon tetrachloride................................. 56-23-5
Chlordane............................................ 57-74-9
Chlorobenzilate...................................... 510-15-6
Chloroform........................................... 67-66-3
Chloroprene.......................................... 126-99-8
Cresols (mixed)...................................... 1319-77-3
DDE.................................................. 3547-04-4
Dichloroethyl ether.................................. 111-44-4
Dichlorvos........................................... 62-73-7
Epichlorohydrin...................................... 106-89-8
Ethyl acrylate....................................... 140-88-5
Ethylene dibromide................................... 106-93-4
Ethylene dichloride.................................. 107-06-2
Ethylene oxide....................................... 75-21-8
Ethylene thiourea.................................... 96-45-7
Ethylidene dichloride (1,1-Dichloroethane)........... 75-34-3
Formaldehyde......................................... 50-00-0
Heptachlor........................................... 76-44-8
Hexachlorobenzene.................................... 118-74-1
Hexachlorobutadiene.................................. 87-68-3
Hexachloroethane..................................... 67-72-1
Hydrazine............................................ 302-01-2
Isophorone........................................... 78-59-1
Lindane (hexachlorocyclohexane, all isomers)......... 58-89-9
m-Cresol............................................. 108-39-4
Methylene chloride................................... 75-09-2
Naphthalene.......................................... 91-20-3
Nitrobenzene......................................... 98-95-3
Nitrosodimethylamine................................. 62-75-9
o-Cresol............................................. 95-48-7
o-Toluidine.......................................... 95-53-4
Parathion............................................ 56-38-2
p-Cresol............................................. 106-44-5
p-Dichlorobenzene.................................... 106-46-7
Pentachloronitrobenzene.............................. 82-68-8
Pentachlorophenol.................................... 87-86-5
Propoxur............................................. 114-26-1
Propylene dichloride................................. 78-87-5
Propylene oxide...................................... 75-56-9
Quinoline............................................ 91-22-5
Tetrachloroethene.................................... 127-18-4
Toxaphene............................................ 8001-35-2
Trichloroethylene.................................... 79-01-6
Trifluralin.......................................... 1582-09-8
Vinyl bromide........................................ 593-60-2
Vinyl chloride....................................... 75-01-4
Vinylidene chloride.................................. 75-35-4
------------------------------------------------------------------------
[FR Doc. 2020-00303 Filed 2-24-20; 8:45 am]