Southern Nuclear Operating Company; Vogtle Electric Generating Plant, Units 3 and 4; Ventilation System Changes, 34994 [2017-15756]
Download as PDF
34994
Federal Register / Vol. 82, No. 143 / Thursday, July 27, 2017 / Notices
position of operability in the face of
conflicting information. The
information that engineering
management relied on to support
operability was demonstrably irrelevant.
The request, except for the
petitioner’s item 3, which does not
request enforcement action, is being
treated pursuant to 10 CFR 2.206 of the
Commission’s regulations. The request
has been referred to the Director of the
Office of Nuclear Reactor Regulation. As
provided by 10 CFR 2.206, appropriate
action will be taken on this petition
within a reasonable time. The petitioner
met with the Petition Review Board
(PRB) on April 13, 2017, to discuss the
petition; the transcript of that meeting is
an additional supplement to the petition
(ADAMS Accession No. ML17111A774).
On June 12, 2017, the petition manager
informed the petitioner that the PRB
accepted the petition items 1, 2, 4, and
5 for review under 10 CFR 2.206.
Dated at Rockville, Maryland, this 20th day
of July, 2017.
For the Nuclear Regulatory Commission.
Brian E. Holian,
Acting Director, Office of Nuclear Reactor
Regulation.
[FR Doc. 2017–15859 Filed 7–26–17; 8:45 am]
BILLING CODE 7590–01–P
NUCLEAR REGULATORY
COMMISSION
[Docket Nos. 52–025 and 52–026; NRC–
2008–0252]
Southern Nuclear Operating Company;
Vogtle Electric Generating Plant, Units
3 and 4; Ventilation System Changes
Nuclear Regulatory
Commission.
ACTION: License amendment application;
withdrawal by applicant.
AGENCY:
The U.S. Nuclear Regulatory
Commission (NRC) has granted the
request of Southern Nuclear Operating
Company (SNC) to withdraw its
application dated December 9, 2016, for
a proposed amendment and exemption
to Combined Licenses (COL), NPF–91
and NPF–92 for the Vogtle Electric
Generating Plant Units 3 and 4,
respectively. The proposed amendment
would have revised the COLs
concerning the design details of the
containment recirculation cooling
system (VCS) and radiologically
controlled area ventilation system
(VAS). SNC submitted the withdrawal
request in a letter dated June 28, 2017.
DATES: July 27, 2017.
ADDRESSES: Please refer to Docket ID
NRC–2008–0252 when contacting the
mstockstill on DSK30JT082PROD with NOTICES
SUMMARY:
VerDate Sep<11>2014
19:17 Jul 26, 2017
Jkt 241001
NRC about the availability of
information regarding this document.
You may obtain publicly-available
information related to this document
using any of the following methods:
• Federal Rulemaking Web site: Go to
https://www.regulations.gov and search
for Docket ID NRC–2008–0252. Address
questions about NRC dockets to Carol
Gallagher; telephone: 301–415–3463;
email: Carol.Gallagher@nrc.gov. For
technical questions, contact the
individual listed in the FOR FURTHER
INFORMATION CONTACT section of this
document.
• NRC’s Agencywide Documents
Access and Management System
(ADAMS): You may obtain publiclyavailable documents online in the
ADAMS Public Documents collection at
https://www.nrc.gov/reading-rm/
adams.html. To begin the search, select
‘‘ADAMS Public Documents’’ and then
select ‘‘Begin Web-based ADAMS
Search.’’ For problems with ADAMS,
please contact the NRC’s Public
Document Room (PDR) reference staff at
1–800–397–4209, 301–415–4737, or by
email to pdr.resource@nrc.gov. The
ADAMS accession number for each
document referenced (if it is available in
ADAMS) is provided the first time that
it is mentioned in this document. The
request for the amendment and
exemption was submitted by letter
dated December 9, 2016, and is
available in ADAMS under Accession
No. ML16344A411.
• NRC’s PDR: You may examine and
purchase copies of public documents at
the NRC’s PDR, Room O1–F21, One
White Flint North, 11555 Rockville
Pike, Rockville, Maryland 20852.
FOR FURTHER INFORMATION CONTACT:
Ruth C. Reyes, Office of New Reactors,
U.S. Nuclear Regulatory Commission,
Washington, DC 20555–0001; telephone:
301–415–3249; email: Ruth.Reyes@
nrc.gov.
SUPPLEMENTARY INFORMATION: The NRC
has granted the request of SNC (the
licensee) to withdraw its December 9,
2016, application (ADAMS Accession
No. ML16344A411) for proposed
amendment and exemption to COL
NPF–91 and NPF–92 for the Vogtle
Electric Generating Plant Units 3 and 4,
respectively, located in Burke County,
Georgia.
The proposed amendment would
have changed plant-specific Tier 1 (and
COL Appendix C) Tables 2.7.5–1, 2.7.5–
2, and 2.7.7–3 and associated Updated
Final Safety Analysis Report text, tables,
and figures related to: (1) Modifying the
configuration of the containment
recirculation fan coil unit assemblies of
the VCS, and revising the values for the
PO 00000
Frm 00072
Fmt 4703
Sfmt 4703
various design parameters affected by
this re-configuration, (2) adding a fourth
pressure differential indicator to the
radiologically controlled area
ventilation system to be located in the
auxiliary building component cooling
system valve room, and (3) reducing the
total ventilation flow provided through
the VAS fuel handling area ventilation
subsystem as a result of a reduction in
heat loads in the areas serviced by the
VAS.
This proposed amendment request
was noticed in the Federal Register (82
FR 13662) dated March 14, 2017.
Dated at Rockville, Maryland, this 18th day
of July 2017.
For the Nuclear Regulatory Commission.
Jennifer Dixon-Herrity,
Chief, Licensing Branch 4, Division of New
Reactor Licensing, Office of New Reactors.
[FR Doc. 2017–15756 Filed 7–26–17; 8:45 am]
BILLING CODE 7590–01–P
NUCLEAR REGULATORY
COMMISSION
[NRC–2017–0127]
Information Collection: Licenses and
Radiation Safety Requirements for
Irradiators
Nuclear Regulatory
Commission.
ACTION: Renewal of existing information
collection; request for comment.
AGENCY:
The U.S. Nuclear Regulatory
Commission (NRC) invites public
comment on the renewal of Office of
Management and Budget (OMB)
approval for an existing collection of
information. The information collection
is entitled, ‘‘Licenses and Radiation
Safety Requirements for Irradiators.’’
DATES: Submit comments by September
25, 2017. Comments received after this
date will be considered if it is practical
to do so, but the Commission is able to
ensure consideration only for comments
received on or before this date.
ADDRESSES: You may submit comments
by any of the following methods:
• Federal Rulemaking Web site: Go to
https://www.regulations.gov and search
for Docket ID NRC–2017–0127. Address
questions about NRC dockets to Carol
Gallagher; telephone: 301–415–3463;
email: Carol.Gallagher@nrc.gov. For
technical questions, contact the
individual listed in the FOR FURTHER
INFORMATION CONTACT section of this
document.
• Mail comments to: David Cullison,
Office of the Chief Information Officer,
Mail Stop: T–5 F53, U.S. Nuclear
SUMMARY:
E:\FR\FM\27JYN1.SGM
27JYN1
Agencies
[Federal Register Volume 82, Number 143 (Thursday, July 27, 2017)]
[Notices]
[Page 34994]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 2017-15756]
-----------------------------------------------------------------------
NUCLEAR REGULATORY COMMISSION
[Docket Nos. 52-025 and 52-026; NRC-2008-0252]
Southern Nuclear Operating Company; Vogtle Electric Generating
Plant, Units 3 and 4; Ventilation System Changes
AGENCY: Nuclear Regulatory Commission.
ACTION: License amendment application; withdrawal by applicant.
-----------------------------------------------------------------------
SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) has granted the
request of Southern Nuclear Operating Company (SNC) to withdraw its
application dated December 9, 2016, for a proposed amendment and
exemption to Combined Licenses (COL), NPF-91 and NPF-92 for the Vogtle
Electric Generating Plant Units 3 and 4, respectively. The proposed
amendment would have revised the COLs concerning the design details of
the containment recirculation cooling system (VCS) and radiologically
controlled area ventilation system (VAS). SNC submitted the withdrawal
request in a letter dated June 28, 2017.
DATES: July 27, 2017.
ADDRESSES: Please refer to Docket ID NRC-2008-0252 when contacting the
NRC about the availability of information regarding this document. You
may obtain publicly-available information related to this document
using any of the following methods:
Federal Rulemaking Web site: Go to https://www.regulations.gov and search for Docket ID NRC-2008-0252. Address
questions about NRC dockets to Carol Gallagher; telephone: 301-415-
3463; email: Carol.Gallagher@nrc.gov. For technical questions, contact
the individual listed in the FOR FURTHER INFORMATION CONTACT section of
this document.
NRC's Agencywide Documents Access and Management System
(ADAMS): You may obtain publicly-available documents online in the
ADAMS Public Documents collection at https://www.nrc.gov/reading-rm/adams.html. To begin the search, select ``ADAMS Public Documents'' and
then select ``Begin Web-based ADAMS Search.'' For problems with ADAMS,
please contact the NRC's Public Document Room (PDR) reference staff at
1-800-397-4209, 301-415-4737, or by email to pdr.resource@nrc.gov. The
ADAMS accession number for each document referenced (if it is available
in ADAMS) is provided the first time that it is mentioned in this
document. The request for the amendment and exemption was submitted by
letter dated December 9, 2016, and is available in ADAMS under
Accession No. ML16344A411.
NRC's PDR: You may examine and purchase copies of public
documents at the NRC's PDR, Room O1-F21, One White Flint North, 11555
Rockville Pike, Rockville, Maryland 20852.
FOR FURTHER INFORMATION CONTACT: Ruth C. Reyes, Office of New Reactors,
U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001;
telephone: 301-415-3249; email: Ruth.Reyes@nrc.gov.
SUPPLEMENTARY INFORMATION: The NRC has granted the request of SNC (the
licensee) to withdraw its December 9, 2016, application (ADAMS
Accession No. ML16344A411) for proposed amendment and exemption to COL
NPF-91 and NPF-92 for the Vogtle Electric Generating Plant Units 3 and
4, respectively, located in Burke County, Georgia.
The proposed amendment would have changed plant-specific Tier 1
(and COL Appendix C) Tables 2.7.5-1, 2.7.5-2, and 2.7.7-3 and
associated Updated Final Safety Analysis Report text, tables, and
figures related to: (1) Modifying the configuration of the containment
recirculation fan coil unit assemblies of the VCS, and revising the
values for the various design parameters affected by this re-
configuration, (2) adding a fourth pressure differential indicator to
the radiologically controlled area ventilation system to be located in
the auxiliary building component cooling system valve room, and (3)
reducing the total ventilation flow provided through the VAS fuel
handling area ventilation subsystem as a result of a reduction in heat
loads in the areas serviced by the VAS.
This proposed amendment request was noticed in the Federal Register
(82 FR 13662) dated March 14, 2017.
Dated at Rockville, Maryland, this 18th day of July 2017.
For the Nuclear Regulatory Commission.
Jennifer Dixon-Herrity,
Chief, Licensing Branch 4, Division of New Reactor Licensing, Office of
New Reactors.
[FR Doc. 2017-15756 Filed 7-26-17; 8:45 am]