South Carolina Electric & Gas Company; South Carolina Public Service Authority; Virgil C. Summer Nuclear Station, Units 2 and 3; Containment Hydrogen Igniter Changes, 92859-92860 [2016-30608]
Download as PDF
Federal Register / Vol. 81, No. 244 / Tuesday, December 20, 2016 / Notices
NUCLEAR REGULATORY
COMMISSION
[Docket Nos. 52–027 and 52–028; NRC–
2008–0441]
South Carolina Electric & Gas
Company; South Carolina Public
Service Authority; Virgil C. Summer
Nuclear Station, Units 2 and 3;
Containment Hydrogen Igniter
Changes
Nuclear Regulatory
Commission.
ACTION: Exemption and combined
license amendment; issuance.
AGENCY:
The U.S. Nuclear Regulatory
Commission (NRC) is granting an
exemption to allow a departure from
elements of the certification information
in Tier 1 of the AP1000 generic Design
Control Document (DCD), as specified in
License Amendment Request 14–18,
and is issuing License Amendment No.
54 to Combined Licenses (COLs), NPF–
93 and NPF–94. The COLs were issued
to South Carolina Electric & Gas
Company and the South Carolina Public
Service Authority, (both collectively
referred to as the licensee); for
construction and operation of the Virgil
C. Summer Nuclear Station (VCSNS)
Units 2 and 3, located in Fairfield
County, South Carolina.
The granting of the exemption allows
the changes to plant-specific Tier 1
information, and the associated COL
Appendix C, requested in the
amendment. Because the acceptability
of the exemption was determined in
part by the acceptability of the
amendment, the exemption and
amendment are being issued
concurrently.
SUMMARY:
The exemption was issued on
November 21, 2016.
ADDRESSES: Please refer to Docket ID
NRC–2008–0441 when contacting the
NRC about the availability of
information regarding this document.
You may obtain publicly-available
information related to this document
using any of the following methods:
• Federal Rulemaking Web site: Go to
https://www.regulations.gov and search
for Docket ID NRC–2008–0441. Address
questions about NRC dockets to Carol
Gallagher; telephone: 301–415–3463;
email: Carol.Gallagher@nrc.gov. For
technical questions, contact the
individual listed in the FOR FURTHER
INFORMATION CONTACT section of this
document.
• NRC’s Agencywide Documents
Access and Management System
(ADAMS): You may obtain publiclyavailable documents online in the
mstockstill on DSK3G9T082PROD with NOTICES
DATES:
VerDate Sep<11>2014
19:36 Dec 19, 2016
Jkt 241001
ADAMS Public Documents collection at
https://www.nrc.gov/reading-rm/
adams.html. To begin the search, select
‘‘ADAMS Public Documents’’ and then
select ‘‘Begin Web-based ADAMS
Search.’’ For problems with ADAMS,
please contact the NRC’s Public
Document Room (PDR) reference staff at
1–800–397–4209, 301–415–4737, or by
email to pdr.resource@nrc.gov. The
ADAMS accession number for each
document referenced (if it is available in
ADAMS) is provided the first time that
it is mentioned in this document. The
request for the amendment and
exemption was submitted by letter
dated May 6, 2015 (ADAMS Accession
No. ML15127A177) and supplemented
by letter dated December 15, 2015
(ADAMS Accession No. ML15350A193).
• NRC’s PDR: You may examine and
purchase copies of public documents at
the NRC’s PDR, Room O1–F21, One
White Flint North, 11555 Rockville
Pike, Rockville, Maryland 20852.
FOR FURTHER INFORMATION CONTACT:
William Gleaves, Office of New
Reactors, U.S. Nuclear Regulatory
Commission, Washington, DC 20555–
0001; telephone: 301–415–5848; email:
Bill.Gleaves@nrc.gov.
SUPPLEMENTARY INFORMATION:
I. Introduction
The NRC is granting an exemption
from Paragraph B of Section III, ‘‘Scope
and Contents,’’ of Appendix d, ‘‘Design
Certification Rule for the AP1000,’’ to
part 52 of title 10 of the Code of Federal
Regulations (10 CFR), and issuing
License Amendment No. 54 to COLs,
NPF–93 and NPF–94, to the licensee.
The exemption is required by Paragraph
A.4 of Section VIII, ‘‘Processes for
Changes and Departures,’’ Appendix d,
to 10 CFR part 52 to allow the licensee
to depart from Tier 1 information. With
the requested amendment, the licensee
sought proposed changes to the Updated
Final Safety Analysis Report (UFSAR)
in the form of departures from the
incorporated plant-specific Design
Control Document (DCD) Tier 2
information. The proposed amendment
also involves related changes to plantspecific Tier 1 information, with
corresponding changes to the associated
COL Appendix C information.
Specifically, the licensee requested
changes to plant-specific Tier 1 (and
COL Appendix C) tables and UFSAR
tables, text, and figures related to the
addition of two hydrogen igniters above
the in-containment refueling water
storage tank roof vents. Part of the
justification for granting the exemption
was provided by the review of the
amendment. Because the exemption is
PO 00000
Frm 00090
Fmt 4703
Sfmt 4703
92859
necessary in order to issue the requested
license amendment, the NRC granted
the exemption and issued the
amendment concurrently, rather than in
sequence. This included issuing a
combined safety evaluation containing
the NRC staff’s review of both the
exemption request and the license
amendment. The exemption met all
applicable regulatory criteria set forth in
10 CFR 50.12, 10 CFR 52.7, and Section
VIII.A.4 of Appendix d to 10 CFR part
52. The license amendment was found
to be acceptable as well. The combined
safety evaluation is available in ADAMS
under Accession No. ML16145A474.
Identical exemption documents
(except for referenced unit numbers and
license numbers) were issued to the
licensee for VCSNS Units 2 and 3 (COLs
NPF–93 and NPF–94). The exemption
documents for VCSNS Units 2 and 3 can
be found in ADAMS under Accession
Nos. ML16145A455 and ML16281A132,
respectively. The exemption is
reproduced (with the exception of
abbreviated titles and additional
citations) in Section II of this document.
The amendment documents for COLs
NPF–93 and NPF–94 are available in
ADAMS under Accession Nos.
ML16145A408 and ML16145A423,
respectively. A summary of the
amendment documents is provided in
Section III of this document.
II. Exemption
Reproduced below is the exemption
document issued to VCSNS Units 2 and
Unit 3. It makes reference to the
combined safety evaluation that
provides the reasoning for the findings
made by the NRC (and listed under Item
1) in order to grant the exemption:
1. In a letter dated May 6, 2015, as
supplemented by letter dated December
15, 2015, the licensee requested from
the Commission an exemption to allow
departures to plant-specific Tier 1, and
the associated COL Appendix C,
information from the certified AP1000
DCD that was incorporated by reference
to 10 CFR part 52, Appendix d, as part
of License Amendment Request 14–18,
‘‘Containment Hydrogen Igniter
Changes.’’
For the reasons set forth in Section
3.1, of the NRC staff’s Safety Evaluation
that supports this license amendment,
which can be found at ADAMS
Accession No. ML16145A474, the
Commission finds that:
A. The exemption is authorized by
law;
B. the exemption presents no undue
risk to public health and safety;
C. the exemption is consistent with
the common defense and security;
E:\FR\FM\20DEN1.SGM
20DEN1
92860
Federal Register / Vol. 81, No. 244 / Tuesday, December 20, 2016 / Notices
mstockstill on DSK3G9T082PROD with NOTICES
D. special circumstances are present
in that the application of the rule in this
circumstance is not necessary to serve
the underlying purpose of the rule;
E. the special circumstances outweigh
any decrease in safety that may result
from the reduction in standardization
caused by the exemption; and
F. the exemption will not result in a
significant decrease in the level of safety
otherwise provided by the design.
2. Accordingly, the licensee is granted
an exemption from the certified AP1000
DCD plant-specific Tier 1 information,
with corresponding changes to
Appendix C of the Facility Combined
License as described in the licensee’s
request dated May 6, 2015, as
supplemented by letter dated December
15, 2015. This exemption is related to,
and necessary for, the granting of
License Amendment No. 54, which is
being issued concurrently with this
exemption.
3. As explained in Section 5 of the
NRC staff’s Safety Evaluation that
supports this license amendment, this
exemption meets the eligibility criteria
for categorical exclusion set forth in 10
CFR 51.22(c)(9). Therefore, pursuant to
10 CFR 51.22(b), no environmental
impact statement or environmental
assessment needs to be prepared in
connection with the issuance of the
exemption.
4. This exemption is effective as of the
date of its issuance.
III. License Amendment Request
By letter dated May 6, 2015, as
supplemented by letter dated December
15, 2015, the licensee requested that the
NRC amend the COLs for VCSNS, Units
2 and 3, COLs NPF–93 and NPF–94. The
proposed amendment is described in
Section I of this Federal Register Notice.
The Commission has determined for
these amendments that the application
complies with the standards and
requirements of the Atomic Energy Act
of 1954, as amended (the Act), and the
Commission’s rules and regulations.
The Commission has made appropriate
findings as required by the Act and the
Commission’s rules and regulations in
10 CFR chapter I, which are set forth in
the license amendment.
A notice of consideration of issuance
of amendment to facility operating
license or COL, as applicable, proposed
no significant hazards consideration
determination, and opportunity for a
hearing in connection with these
actions, was published in the Federal
Register on September 29, 2015 (80 FR
58519). No comments were received
during the 30-day comment period. The
supplement contained no information
that would change the original proposed
VerDate Sep<11>2014
19:36 Dec 19, 2016
Jkt 241001
no significant hazards consideration
determination.
The Commission has determined that
these amendments satisfy the criteria for
categorical exclusion in accordance
with 10 CFR 51.22. Therefore, pursuant
to 10 CFR 51.22(b), no environmental
impact statement or environmental
assessment need be prepared for these
amendments.
IV. Conclusion
Using the reasons set forth in the
combined safety evaluation, the staff
granted the exemption and issued the
amendment that the licensee requested
by letter dated May 6, 2015 and
supplemented on December 15, 2015.
The exemption and amendment were
issued on November 21, 2016 as part of
a combined package to the licensee
(ADAMS Accession No. ML16145A391).
Dated at Rockville, Maryland, this 12th day
of December 2016.
For the Nuclear Regulatory Commission.
Jennifer Dixon-Herrity,
Chief, Licensing Branch 4, Division of New
Reactor Licensing, Office of New Reactors.
[FR Doc. 2016–30608 Filed 12–19–16; 8:45 am]
BILLING CODE 7590–01–P
NUCLEAR REGULATORY
COMMISSION
[Docket Nos. 52–025 and 52–026; NRC–
2008–0252]
Southern Nuclear Operating Company,
Inc., Vogtle Electric Generating Plant,
Units 3 and 4; Initial Test Program
Changes
Nuclear Regulatory
Commission.
ACTION: Exemption and combined
license amendment; issuance.
AGENCY:
The U.S. Nuclear Regulatory
Commission (NRC) is granting an
exemption to allow a departure from the
certification information of Tier 1 of the
generic design control document (DCD)
and is issuing License Amendment No.
34 to Combined Licenses (COL), NPF–
91 and NPF–92. The COLs were issued
to Southern Nuclear Operating
Company, Inc., and Georgia Power
Company, Oglethorpe Power
Corporation, MEAG Power SPVM, LLC,
MEAG Power SPVJ, LLC, MEAG Power
SPVP, LLC, Authority of Georgia, and
the City of Dalton, Georgia (the
licensee); for construction and operation
of the Vogtle Electric Generating Plant
(VEGP) Units 3 and 4, located in Burke
County, Georgia.
The granting of the exemption allows
the changes to Tier 1 information asked
for in the amendment. Because the
SUMMARY:
PO 00000
Frm 00091
Fmt 4703
Sfmt 4703
acceptability of the exemption was
determined in part by the acceptability
of the amendment, the exemption and
amendment are being issued
concurrently.
DATES: The Exemption was issued on
June 4, 2015.
ADDRESSES: Please refer to Docket ID
NRC–2008–0252 when contacting the
NRC about the availability of
information regarding this document.
You may access information related to
this document, which the NRC
possesses and is publicly available,
using any of the following methods:
• Federal Rulemaking Web site: Go to
https://www.regulations.gov and search
for Docket ID NRC–2008–0252. Address
questions about NRC dockets to Carol
Gallagher; telephone: 301–415–3463;
email: Carol.Gallagher@nrc.gov. For
technical questions, contact the
individual listed in the FOR FURTHER
INFORMATION CONTACT section of this
document.
• NRC’s Agencywide Documents
Access and Management System
(ADAMS): You may obtain publiclyavailable documents online in the
ADAMS Public Documents collection at
https://www.nrc.gov/reading-rm/
adams.html. To begin the search, select
‘‘ADAMS Public Documents’’ and then
select ‘‘Begin Web-based ADAMS
Search.’’ For problems with ADAMS,
please contact the NRC’s Public
Document Room (PDR) reference staff at
1–800–397–4209, 301–415–4737, or by
email to pdr.resource@nrc.gov. The
ADAMS accession number for each
document referenced (if it is available in
ADAMS) is provided the first time that
it is mentioned in this document. The
request for the amendment and
exemption was submitted by letter
dated November 21, 2014, and available
in ADAMS under Accession No.
ML14325A835.
• NRC’s PDR: You may examine and
purchase copies of public documents at
the NRC’s PDR, Room O1–F21, One
White Flint North, 11555 Rockville
Pike, Rockville, Maryland 20852.
FOR FURTHER INFORMATION CONTACT:
Chandu Patel, Office of New Reactors,
U.S. Nuclear Regulatory Commission,
Washington, DC 20555–0001; telephone:
301–415–3025; email: Chandu.Patel@
nrc.gov.
SUPPLEMENTARY INFORMATION:
I. Introduction
The NRC is granting an exemption
from Paragraph B of Section III, ‘‘Scope
and Contents,’’ of Appendix d, ‘‘Design
Certification Rule for the AP1000,’’ to
part 52 of title 10 of the Code of Federal
Regulations (10 CFR), and issuing
E:\FR\FM\20DEN1.SGM
20DEN1
Agencies
[Federal Register Volume 81, Number 244 (Tuesday, December 20, 2016)]
[Notices]
[Pages 92859-92860]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 2016-30608]
[[Page 92859]]
-----------------------------------------------------------------------
NUCLEAR REGULATORY COMMISSION
[Docket Nos. 52-027 and 52-028; NRC-2008-0441]
South Carolina Electric & Gas Company; South Carolina Public
Service Authority; Virgil C. Summer Nuclear Station, Units 2 and 3;
Containment Hydrogen Igniter Changes
AGENCY: Nuclear Regulatory Commission.
ACTION: Exemption and combined license amendment; issuance.
-----------------------------------------------------------------------
SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) is granting an
exemption to allow a departure from elements of the certification
information in Tier 1 of the AP1000 generic Design Control Document
(DCD), as specified in License Amendment Request 14-18, and is issuing
License Amendment No. 54 to Combined Licenses (COLs), NPF-93 and NPF-
94. The COLs were issued to South Carolina Electric & Gas Company and
the South Carolina Public Service Authority, (both collectively
referred to as the licensee); for construction and operation of the
Virgil C. Summer Nuclear Station (VCSNS) Units 2 and 3, located in
Fairfield County, South Carolina.
The granting of the exemption allows the changes to plant-specific
Tier 1 information, and the associated COL Appendix C, requested in the
amendment. Because the acceptability of the exemption was determined in
part by the acceptability of the amendment, the exemption and amendment
are being issued concurrently.
DATES: The exemption was issued on November 21, 2016.
ADDRESSES: Please refer to Docket ID NRC-2008-0441 when contacting the
NRC about the availability of information regarding this document. You
may obtain publicly-available information related to this document
using any of the following methods:
Federal Rulemaking Web site: Go to https://www.regulations.gov and search for Docket ID NRC-2008-0441. Address
questions about NRC dockets to Carol Gallagher; telephone: 301-415-
3463; email: Carol.Gallagher@nrc.gov. For technical questions, contact
the individual listed in the FOR FURTHER INFORMATION CONTACT section of
this document.
NRC's Agencywide Documents Access and Management System
(ADAMS): You may obtain publicly-available documents online in the
ADAMS Public Documents collection at https://www.nrc.gov/reading-rm/adams.html. To begin the search, select ``ADAMS Public Documents'' and
then select ``Begin Web-based ADAMS Search.'' For problems with ADAMS,
please contact the NRC's Public Document Room (PDR) reference staff at
1-800-397-4209, 301-415-4737, or by email to pdr.resource@nrc.gov. The
ADAMS accession number for each document referenced (if it is available
in ADAMS) is provided the first time that it is mentioned in this
document. The request for the amendment and exemption was submitted by
letter dated May 6, 2015 (ADAMS Accession No. ML15127A177) and
supplemented by letter dated December 15, 2015 (ADAMS Accession No.
ML15350A193).
NRC's PDR: You may examine and purchase copies of public
documents at the NRC's PDR, Room O1-F21, One White Flint North, 11555
Rockville Pike, Rockville, Maryland 20852.
FOR FURTHER INFORMATION CONTACT: William Gleaves, Office of New
Reactors, U.S. Nuclear Regulatory Commission, Washington, DC 20555-
0001; telephone: 301-415-5848; email: Bill.Gleaves@nrc.gov.
SUPPLEMENTARY INFORMATION:
I. Introduction
The NRC is granting an exemption from Paragraph B of Section III,
``Scope and Contents,'' of Appendix d, ``Design Certification Rule for
the AP1000,'' to part 52 of title 10 of the Code of Federal Regulations
(10 CFR), and issuing License Amendment No. 54 to COLs, NPF-93 and NPF-
94, to the licensee. The exemption is required by Paragraph A.4 of
Section VIII, ``Processes for Changes and Departures,'' Appendix d, to
10 CFR part 52 to allow the licensee to depart from Tier 1 information.
With the requested amendment, the licensee sought proposed changes to
the Updated Final Safety Analysis Report (UFSAR) in the form of
departures from the incorporated plant-specific Design Control Document
(DCD) Tier 2 information. The proposed amendment also involves related
changes to plant-specific Tier 1 information, with corresponding
changes to the associated COL Appendix C information. Specifically, the
licensee requested changes to plant-specific Tier 1 (and COL Appendix
C) tables and UFSAR tables, text, and figures related to the addition
of two hydrogen igniters above the in-containment refueling water
storage tank roof vents. Part of the justification for granting the
exemption was provided by the review of the amendment. Because the
exemption is necessary in order to issue the requested license
amendment, the NRC granted the exemption and issued the amendment
concurrently, rather than in sequence. This included issuing a combined
safety evaluation containing the NRC staff's review of both the
exemption request and the license amendment. The exemption met all
applicable regulatory criteria set forth in 10 CFR 50.12, 10 CFR 52.7,
and Section VIII.A.4 of Appendix d to 10 CFR part 52. The license
amendment was found to be acceptable as well. The combined safety
evaluation is available in ADAMS under Accession No. ML16145A474.
Identical exemption documents (except for referenced unit numbers
and license numbers) were issued to the licensee for VCSNS Units 2 and
3 (COLs NPF-93 and NPF-94). The exemption documents for VCSNS Units 2
and 3 can be found in ADAMS under Accession Nos. ML16145A455 and
ML16281A132, respectively. The exemption is reproduced (with the
exception of abbreviated titles and additional citations) in Section II
of this document. The amendment documents for COLs NPF-93 and NPF-94
are available in ADAMS under Accession Nos. ML16145A408 and
ML16145A423, respectively. A summary of the amendment documents is
provided in Section III of this document.
II. Exemption
Reproduced below is the exemption document issued to VCSNS Units 2
and Unit 3. It makes reference to the combined safety evaluation that
provides the reasoning for the findings made by the NRC (and listed
under Item 1) in order to grant the exemption:
1. In a letter dated May 6, 2015, as supplemented by letter dated
December 15, 2015, the licensee requested from the Commission an
exemption to allow departures to plant-specific Tier 1, and the
associated COL Appendix C, information from the certified AP1000 DCD
that was incorporated by reference to 10 CFR part 52, Appendix d, as
part of License Amendment Request 14-18, ``Containment Hydrogen Igniter
Changes.''
For the reasons set forth in Section 3.1, of the NRC staff's Safety
Evaluation that supports this license amendment, which can be found at
ADAMS Accession No. ML16145A474, the Commission finds that:
A. The exemption is authorized by law;
B. the exemption presents no undue risk to public health and
safety;
C. the exemption is consistent with the common defense and
security;
[[Page 92860]]
D. special circumstances are present in that the application of the
rule in this circumstance is not necessary to serve the underlying
purpose of the rule;
E. the special circumstances outweigh any decrease in safety that
may result from the reduction in standardization caused by the
exemption; and
F. the exemption will not result in a significant decrease in the
level of safety otherwise provided by the design.
2. Accordingly, the licensee is granted an exemption from the
certified AP1000 DCD plant-specific Tier 1 information, with
corresponding changes to Appendix C of the Facility Combined License as
described in the licensee's request dated May 6, 2015, as supplemented
by letter dated December 15, 2015. This exemption is related to, and
necessary for, the granting of License Amendment No. 54, which is being
issued concurrently with this exemption.
3. As explained in Section 5 of the NRC staff's Safety Evaluation
that supports this license amendment, this exemption meets the
eligibility criteria for categorical exclusion set forth in 10 CFR
51.22(c)(9). Therefore, pursuant to 10 CFR 51.22(b), no environmental
impact statement or environmental assessment needs to be prepared in
connection with the issuance of the exemption.
4. This exemption is effective as of the date of its issuance.
III. License Amendment Request
By letter dated May 6, 2015, as supplemented by letter dated
December 15, 2015, the licensee requested that the NRC amend the COLs
for VCSNS, Units 2 and 3, COLs NPF-93 and NPF-94. The proposed
amendment is described in Section I of this Federal Register Notice.
The Commission has determined for these amendments that the
application complies with the standards and requirements of the Atomic
Energy Act of 1954, as amended (the Act), and the Commission's rules
and regulations. The Commission has made appropriate findings as
required by the Act and the Commission's rules and regulations in 10
CFR chapter I, which are set forth in the license amendment.
A notice of consideration of issuance of amendment to facility
operating license or COL, as applicable, proposed no significant
hazards consideration determination, and opportunity for a hearing in
connection with these actions, was published in the Federal Register on
September 29, 2015 (80 FR 58519). No comments were received during the
30-day comment period. The supplement contained no information that
would change the original proposed no significant hazards consideration
determination.
The Commission has determined that these amendments satisfy the
criteria for categorical exclusion in accordance with 10 CFR 51.22.
Therefore, pursuant to 10 CFR 51.22(b), no environmental impact
statement or environmental assessment need be prepared for these
amendments.
IV. Conclusion
Using the reasons set forth in the combined safety evaluation, the
staff granted the exemption and issued the amendment that the licensee
requested by letter dated May 6, 2015 and supplemented on December 15,
2015.
The exemption and amendment were issued on November 21, 2016 as
part of a combined package to the licensee (ADAMS Accession No.
ML16145A391).
Dated at Rockville, Maryland, this 12th day of December 2016.
For the Nuclear Regulatory Commission.
Jennifer Dixon-Herrity,
Chief, Licensing Branch 4, Division of New Reactor Licensing, Office of
New Reactors.
[FR Doc. 2016-30608 Filed 12-19-16; 8:45 am]