Xcel Energy, Monticello Nuclear Generating Plant Independent Spent Fuel Storage Installation, 39069-39076 [2016-14188]
Download as PDF
Federal Register / Vol. 81, No. 115 / Wednesday, June 15, 2016 / Notices
National Endowment for the
Arts, Constitution Center, 400 7th St.
SW., Washington, DC 20506.
FOR FURTHER INFORMATION CONTACT:
Further information with reference to
these meetings can be obtained from Ms.
Kathy Plowitz-Worden, Office of
Guidelines & Panel Operations, National
Endowment for the Arts, Washington,
DC 20506; plowitzk@arts.gov, or call
202/682–5691.
SUPPLEMENTARY INFORMATION: The
closed portions of meetings are for the
purpose of Panel review, discussion,
evaluation, and recommendations on
financial assistance under the National
Foundation on the Arts and the
Humanities Act of 1965, as amended,
including information given in
confidence to the agency. In accordance
with the determination of the Chairman
of February 15, 2012, these sessions will
be closed to the public pursuant to
subsection (c)(6) of section 552b of title
5, United States Code.
ADDRESSES:
Dated: June 10, 2016.
Kathy Plowitz-Worden,
Panel Coordinator, National Endowment for
the Arts.
[FR Doc. 2016–14137 Filed 6–14–16; 8:45 am]
BILLING CODE 7537–01–P
NUCLEAR REGULATORY
COMMISSION
[Docket Nos. 72–58 and 50–263; NRC–2016–
0115]
Xcel Energy, Monticello Nuclear
Generating Plant Independent Spent
Fuel Storage Installation
Nuclear Regulatory
Commission.
ACTION: Exemption; issuance.
AGENCY:
The U.S. Nuclear Regulatory
Commission (NRC) is issuing an
exemption in response to a request
submitted by Xcel Energy on September
29, 2015, from meeting Technical
Specification (TS) 1.2.5 of Attachment A
of Certificate of Compliance (CoC) No.
1004, Amendment No. 10, which
requires that all dry shielded canister
(DSC) closure welds, except those
subjected to full volumetric inspection,
shall be dye penetrant tested in
accordance with the requirements of
American Society of Mechanical
Engineers (ASME) Boiler and Pressure
Vessel (B&PV) Code Section III, Division
1, Article NB–5000. This exemption
applies to one loaded Standardized
NUHOMS® 61BTH, DSC 16 (DSC 16), at
the Monticello Nuclear Generating Plant
(MNGP) Independent Spent Fuel
Storage Installation (ISFSI).
ehiers on DSK5VPTVN1PROD with NOTICES
SUMMARY:
VerDate Sep<11>2014
15:15 Jun 14, 2016
Jkt 238001
Please refer to Docket ID
NRC–2016–0115 when contacting the
NRC about the availability of
information regarding this document.
You may obtain publicly-available
information related to this document
using any of the following methods:
• Federal Rulemaking Web site: Go to
https://www.regulations.gov and search
for Docket ID NRC–2016–0115. Address
questions about NRC dockets to Carol
Gallagher; telephone: 301–415–3463;
email: Carol.Gallagher@nrc.gov. For
technical questions, contact the
individual listed in the FOR FURTHER
INFORMATION CONTACT section of this
document.
• NRC’s Agencywide Documents
Access and Management System
(ADAMS): You may obtain publiclyavailable documents online in the
ADAMS Public Documents collection at
https://www.nrc.gov/reading-rm/
adams.html. To begin the search, select
‘‘ADAMS Public Documents’’ and then
select ‘‘Begin Web-based ADAMS
Search.’’ For problems with ADAMS,
please contact the NRC’s Public
Document Room (PDR) reference staff at
1–800–397–4209, 301–415–4737, or by
email to pdr.resource@nrc.gov. For the
convenience of the reader, the ADAMS
accession numbers are provided in a
table in the ‘‘Availability of Documents’’
section of this document.
• NRC’s PDR: You may examine and
purchase copies of public documents at
the NRC’s PDR, Room O1–F21, One
White Flint North, 11555 Rockville
Pike, Rockville, Maryland 20852.
FOR FURTHER INFORMATION CONTACT:
Christian Jacobs, Office of Nuclear
Material Safety and Safeguards, U.S.
Nuclear Regulatory Commission,
Washington, DC 20555–0001; telephone:
301–415–6825; email: Christian.Jacobs@
nrc.gov.
SUPPLEMENTARY INFORMATION:
ADDRESSES:
I. Background
Northern States Power CompanyMinnesota, doing business as Xcel
Energy (Xcel Energy, or the applicant) is
the holder of Facility Operating License
No. DPR–22, which authorizes
operation of the Monticello Nuclear
Generating Plant (MNGP), Unit No. 1, in
Wright County, Minnesota, pursuant to
part 50 of title 10 of the Code of Federal
Regulations (10 CFR), ‘‘Domestic
Licensing of Production and Utilization
Facilities.’’ The license provides, among
other things, that the facility is subject
to all rules, regulations, and orders of
the NRC now or hereafter in effect.
Consistent with 10 CFR part 72,
subpart K, ‘‘General License for Storage
of Spent Fuel at Power Reactor Sites,’’
PO 00000
Frm 00049
Fmt 4703
Sfmt 4703
39069
a general license is issued for the storage
of spent fuel in an ISFSI at power
reactor sites to persons authorized to
possess or operate nuclear power
reactors under 10 CFR part 50. The
applicant is authorized to operate a
nuclear power reactor under 10 CFR
part 50, and holds a 10 CFR part 72
general license for storage of spent fuel
at the Monticello Nuclear Generating
Plant ISFSI. Under the terms of the
general license, the applicant stores
spent fuel at its ISFSI using the
Transnuclear, Inc. (TN) Standardized
NUHOMS® dry cask storage system
Certificate of Compliance (CoC) No.
1004, Amendments No. 9 and No. 10.
As part of the dry storage system, the
DSC (of which the closure welds are an
integral part) ensures that the dry
storage system can meet the functions of
criticality safety, confinement boundary,
shielding, structural support, and heat
transfer.
II. Request/Action
The applicant has requested an
exemption from the requirements of 10
CFR 72.212(b)(3) and 10 CFR
72.212(b)(11) that require compliance
with the terms, conditions, and
specifications of CoC No. 1004,
Amendment No. 10, for the
Standardized NUHOMS® Horizontal
Modular Storage System, to the extent
necessary for the applicant to transfer
DSC 16 into a Horizontal Storage
Module (HSM). This would permit the
continued storage of that DSC for the
service life of the canister. Specifically,
the exemption would relieve the
applicant from meeting TS 1.2.5 of
Attachment A of CoC No. 1004, which
requires that all DSC closure welds,
except those subjected to full volumetric
inspection, shall be dye penetrant tested
in accordance with the requirements of
the ASME B&PV Code Section III,
Division 1, Article NB–5000. Technical
Specification 1.2.5 further requires that
the liquid penetrant test acceptance
standards shall be those described in
Subsection NB–5350 of the ASME BP&V
Code.
Xcel Energy loaded spent nuclear fuel
into six 61BTH DSCs starting in
September 2013. Subsequent to the
loading, it was discovered that certain
elements of the liquid penetrant test
(PT) examinations, which were
performed on the DSCs to verify the
acceptability of the closure welds, do
not comply with the requirements of TS
1.2.5. All six DSCs were affected. Five
of the six DSCs (numbers 11–15) had
already been loaded in the HSMs when
the discrepancies were discovered. The
DSC 16 remains on the reactor building
refueling floor in a transfer cask (TC).
E:\FR\FM\15JNN1.SGM
15JNN1
ehiers on DSK5VPTVN1PROD with NOTICES
39070
Federal Register / Vol. 81, No. 115 / Wednesday, June 15, 2016 / Notices
Xcel Energy has performed phased array
ultrasonic testing (PAUT) of the closure
welds, supported by analysis, as an
alternate means for verifying the weld
quality. The PAUT nondestructive
examination (NDE) consists of testing
performed by qualified personnel, using
specific procedures and equipment
shown by performance demonstration to
be sufficient to detect the range of
potential weld defects that could be
present in the closure welds. The
exemption request, if approved, would
allow the transfer of DSC 16 into an
HSM, and would permit the continued
storage of that DSC for the service life
of the canister. Xcel Energy plans to
request a separate exemption for the
remaining DSCs (11–15).
In a letter dated September 29, 2015,
as supplemented January 29, 2016, and
March 29, 2016, the applicant requested
an exemption from certain parts of the
following requirements to allow storage
of the DSC at the MNGP ISFSI:
• 10 CFR 72.212(b)(3), which states
that the general licensee must ensure
that each cask used by the general
licensee conforms to the terms,
conditions, and specifications of a CoC
or an amended CoC listed in § 72.214.
• 10 CFR 72.212(b)(11), which states,
in part, that the licensee shall comply
with the terms, conditions, and
specifications of the CoC and, for those
casks to which the licensee has applied
the changes of an amended CoC, the
terms, conditions, and specifications of
the amended CoC.
Upon review, in addition to the
requirements from which the applicant
requested exemption, the NRC staff
determined that exemptions from the
following requirements are also
necessary in order to authorize the
applicant’s request and added the
following requirements to the
exemption for the proposed action
pursuant to its authority under 10 CFR
72.7, ‘‘Specific exemptions’’:
• 10 CFR 72.212(a)(2), which states
that this general license is limited to
storage of spent fuel in casks approved
under the provisions of this part.
• 10 CFR 72.212(b)(5)(i), which
requires that the general licensee
perform written evaluations, before use
and before applying the changes
authorized by an amended CoC to a cask
loaded under the initial CoC or an
earlier amended CoC, which establish
that the cask, once loaded with spent
fuel or once the changes authorized by
an amended CoC have been applied,
will conform to the terms, conditions,
and specifications of a CoC or an
amended CoC listed in § 72.214.
• 10 CFR 72.214, which lists the
approved spent fuel storage casks.
VerDate Sep<11>2014
15:15 Jun 14, 2016
Jkt 238001
III. Discussion
Pursuant to 10 CFR 72.7, the
Commission may, upon application by
any interested person or upon its own
initiative, grant such exemptions from
the requirements of the regulations of 10
CFR part 72 as it determines are
authorized by law and will not endanger
life or property or the common defense
and security and are otherwise in the
public interest.
Authorized by Law
This exemption would allow the
applicant to transfer DSC 16 into an
HSM, and would permit the continued
storage of that DSC at the MNGP ISFSI
for the service life of the canister by
relieving the applicant of the
requirement to meet the liquid
penetrant test requirements of TS 1.2.5
of Attachment A of CoC No. 1004. The
provisions in 10 CFR part 72 from
which the applicant is requesting
exemption, as well as provisions
determined to be applicable by the NRC
staff, require the licensee to comply
with the terms, conditions, and
specifications of the CoC for the
approved cask model it uses. Section
72.7 allows the NRC to grant
exemptions from the requirements of 10
CFR part 72. As explained below, the
proposed exemption will not endanger
life or property, or the common defense
and security, and is otherwise in the
public interest. Issuance of this
exemption is consistent with the Atomic
Energy Act of 1954, as amended, and
not otherwise inconsistent with NRC’s
regulations or other applicable laws.
Therefore, the exemption is authorized
by law.
Will Not Endanger Life or Property or
the Common Defense and Security
This exemption would relieve the
applicant from meeting TS 1.2.5 of
Attachment A of CoC No. 1004, which
requires liquid penetrant test
examinations to be performed on the
DSCs to verify the acceptability of the
closure welds, allowing for transfer of
DSC 16 into an HSM, and would permit
the continued storage of that DSC at the
MNGP ISFSI for the service life of the
canister. This exemption only addresses
DSC 16, for which the PT test was not
performed in accordance with the
examination procedures specified in TS
1.2.5. Xcel Energy performed phased
array ultrasonic testing to
nondestructively examine the welds,
and prepared structural analyses based
on the actual weld quality to verify that
the welds would perform their desired
function over the storage term of the
DSC. As detailed below, NRC staff
PO 00000
Frm 00050
Fmt 4703
Sfmt 4703
reviewed the exemption request to
determine whether granting of the
exemption would cause potential for
danger to life, property, or common
defense and security.
Review of the Requested Exemption
The NUHOMS® system provides
horizontal dry storage of canisterized
spent fuel assemblies in an HSM. The
cask storage system components for
NUHOMS® consist of a reinforced
concrete HSM and a DSC vessel with an
internal basket assembly that holds the
spent fuel assemblies. The HSM is a
low-profile, reinforced concrete
structure designed to withstand all
normal condition loads, as well as
abnormal condition loads created by
natural phenomena such as earthquakes
and tornadoes. It is also designed to
withstand design basis accident
conditions. The Standardized
NUHOMS® Horizontal Modular Storage
System has been approved for storage of
spent fuel under the conditions of
Certificate of Compliance No. 1004. The
DSC under consideration for exemption
was loaded under Certificate of
Compliance No. 1004, Amendment No.
10.
The NRC has previously approved the
Standardized NUHOMS® Horizontal
Modular Storage System. The requested
exemption does not change the
fundamental design, components,
contents, or safety features of the storage
system. The NRC staff has evaluated the
applicable potential safety impacts of
granting the exemption to assess the
potential for danger to life or property
or the common defense and security; the
evaluation and resulting conclusions are
presented below. The potential impacts
identified for this exemption request
were in the areas of materials, structural
integrity, thermal, shielding, and
confinement capability.
Materials Review for the Requested
Exemption: The applicant asserted that
there is reasonable assurance of safety
for the requested exemption for the
transfer of DSC 16 to the MNGP ISFSI
pad. The applicant’s assertion of
reasonable assurance of safety for the
transfer of DSC 16 is based on the
following:
• Repair and verification activities
performed on DSC 16;
• PAUT examination and analysis of
accessible lid welds on DSC 16;
• Short duration and haul distance of
the transfer of DSC 16, and
• The safest location for DSC 16 is in
the HSM.
The applicant asserts that there is a
reasonable assurance of safety for the
requested exemption for DSC 16 (CoC
E:\FR\FM\15JNN1.SGM
15JNN1
ehiers on DSK5VPTVN1PROD with NOTICES
Federal Register / Vol. 81, No. 115 / Wednesday, June 15, 2016 / Notices
No. 1004, Amendment 10) based on the
following:
• Integrity of the fuel (cladding)
creates a fission product barrier;
• The quality of the welding process
employed provides indication of
development of quality welds;
• The advantages of the multi-layer
weld technique which includes the low
probability for flaw propagation, the
subsequent covering of weld layer
surface flaws and the indication of
development of quality welds;
• Visual inspections performed on
the welds met quality requirements;
• The DSC backfill and helium leak
testing results verify confinement
barrier integrity;
• The lack of a failure mechanism
that adversely affects confinement
barrier integrity; and
• Margin of safety is available in the
welds when assuming conservatively
large flaws. These margins are
demonstrated by two different methods:
(1) Structural analysis using an analysisbased Stress Allowance Reduction
Factor and theoretically-bounding fullcircumferential flaws, and (2) a finite
element analysis assuming flaw
distributions conservatively derived
from PAUT examination.
The applicant stated that the PAUT
examination and analysis provides an
objective review of volumetricallyidentified flaw indications in the
accessible DSC 16 Inner Top Cover Plate
(ITCP) and Outer Top Cover Plate
(OTCP) closure welds. The peak strains
in the welds remain well below the
weld material ductility limit when
subjected to the accident pressure and
drop loads. The peak strains have a
margin of safety of 3.69 and 3.60 for
accident pressure and drop loads,
respectively. Furthermore, it was shown
that the strains in the welds remain
stable at 150 percent of the original
design loads for the NUHOMS® 61BTH
DSC. The applicant’s analysis accounted
for the identified ITCP and OTCP
closure weld flaws and the uncertainties
in the PAUT examination. The
applicant stated that this approach,
which is consistent with the NRC’s
Spent Fuel Project Office Interim Staff
Guidance-15 (ISG–15), conservatively
accounts for any additional limitations
in the efficacy of the PAUT
examinations and also accounts for the
inaccessible area around the vent and
siphon block as well as the geometric
reflectors at the root and near the toe of
the closure welds.
The applicant noted that the proposed
exemption applies only to DSC 16 and
is supported by the following reports:
1. Technical Justification for Phased
Array Ultrasonic Examination of Dry
VerDate Sep<11>2014
15:15 Jun 14, 2016
Jkt 238001
Storage Canister Lid Welds Report No.
54–PQ–114–001, January 30, 2015
(AREVA, INC., 2015a).
2. Technical Report of the
Demonstration of UT NDE Procedure
54–UT–114–000 Phased Array
Ultrasonic Examination of Dry Storage
Canister Lid Welds Report No. 51–
9234641–001, January 30, 2015
(AREVA, INC., 2015b).
3. 61BTH ITCP and OTCP Closure
Weld Flaw Evaluation, Calculation
11042–0205 Revision 3 (AREVA, INC.,
2016).
The NRC staff reviewed Technical
Justification for Phased Array Ultrasonic
Examination of Dry Storage Canister Lid
Welds Report No. 54–PQ–114–001,
dated January 30, 2015 (AREVA, INC.,
2015a). This report provides the
detailed technical justification for the
use of the PAUT system to perform the
NDE of the OTCP and ITCP closure
welds of DSC 16. The NRC staff
determined that the technical
justification report was adequate to
justify the use of PAUT to examine the
ITCP and OTCP closure welds because
the report included detailed information
on the PAUT system design, an
assessment of examination sensitivity,
flaw detection, flaw sizing,
identification and effects of influential
parameters, personnel qualification
requirements, components to be
examined, flaws to be detected, and
analysis of flaw detection and flaw
sizing data. In addition, the NRC staff
determined that the report also
described extensive modeling
performed to evaluate PAUT array
configuration, element arrangements,
apertures, frequency, focusing, and
beam angles to develop probes for the
inspections of the ITCP and OTCP
closure welds. The NRC staff also
confirmed that the performance of the
PAUT system was evaluated using
laboratory testing of representative
mockup containing 22 typical welding
manufacturing flaws that have the
potential to exist in field welds. The
NRC staff determined that the laboratory
testing was adequate to verify the
performance of PAUT systems because
the non-blind mockup contained
representative ITCP and OTCP closure
welds with controlled placement of
intentional flaws positioned in difficult
detection locations such as in the weld
root and weld toe regions and were
generally small in size.
The NRC staff also reviewed ISG–15,
which states that closure lid welds
examined by ultrasonic testing (UT)
must use UT acceptance criteria of NB–
5332 for pre-service examination and be
performed in conjunction with the PT of
the root and final pass. The ISG–15 also
PO 00000
Frm 00051
Fmt 4703
Sfmt 4703
39071
states that if progressive PT examination
is used without a volumetric
examination, a stress reduction factor of
0.8 is to be imposed on the weld design.
The NRC staff determined that the
reduction factor of 0.8 considered by the
applicant in their finite element analysis
is sufficient to account for weld flaws
that potentially were not detected by
PAUT, visual inspection and the
compliant PT inspection of the OTCP
final weld pass. The NRC staff reached
this determination based on the
demonstrated ability of the PAUT
examination to detect weld flaws on
both the ITCP and OTCP closure welds
including the root pass and the final
pass shown in the technical justification
of using PAUT to examine the DSC lid
closure welds (AREVA, INC., 2015b).
The NRC staff noted that the PAUT
examination results of the OTCP weld
are consistent with the PT examination
of the OTCP closure weld final pass
after repair and confirmed that no
surface breaking flaws are present.
Thus, the NRC staff determined that
analytical evaluation of the DSC 16
OTCP and ITCP closure welds using the
flaw sizing results obtained by the
PAUT examination, combined with the
discount of the ASME B&PV Code
specified minimum elongations for the
weld material, is an appropriate method
to determine the acceptability of the
DSC inner and outer lid to shell closure
welds.
The NRC staff determined that the
PAUT procedure (AREVA, INC., 2016)
was acceptable because the procedure
was qualified using a blind performance
demonstration in accordance with
ASME B&PV Code Section V, Article 14,
T–1424(b) Intermediate Rigor (ASME
2004 edition) that qualifies the
equipment, procedure, and data analysis
personnel for the detection and
dimensioning of welding fabrication
flaws. The NRC staff determined that
PAUT procedures were also acceptable
because: (1) Personnel conducting the
equipment calibration, data acquisition
or data analyses must be qualified by
the American Society for
Nondestructive Testing (ASNT); (2) the
examination area includes the
accessible area of the ITCP and OTCP
closure welds, and (3) specific
procedures were developed and
demonstrated for both flaw detection
and flaw sizing scans. The NRC staff
determined that the examinations were
appropriate because: (1) They included
>99 percent of the OTCP closure weld
with the exception of two (2) 0.5-inch
long sections that were identified as
limited examination areas as a result of
the two longitudinal welds in the
canister shell; and (2) the entire ITCP
E:\FR\FM\15JNN1.SGM
15JNN1
ehiers on DSK5VPTVN1PROD with NOTICES
39072
Federal Register / Vol. 81, No. 115 / Wednesday, June 15, 2016 / Notices
closure weld with the exception of the
part of the weld located around the
siphon and vent port block resulting in
>90 percent coverage of the ITCP
closure weld (AREVA, INC., 2016). The
NRC staff determined that the personnel
qualifications for equipment calibration,
data acquisition and data analysis are
sufficient because: (1) Data Acquisition
Operators require direct supervision of
American Society for Nondestructive
Testing (ASNT) UT Level II or Level III
staff; (2) both Calibration Personnel and
Data Analysis Personnel were required
to be either ASNT UT Level II or Level
III certification; and (3) lead personnel
responsible for training and review of
flaw indications were required to be
ASNT UT Level III qualified. The NRC
staff determined that the procedures for
the flaw detection scans were adequate,
because: (1) The procedures used the
known geometric features of the DSC to
identify the correct position of the
transducer for complete coverage of the
closure welds to be examined; and (2)
the beams are swept through a range of
angles at specified increments along the
scan line in order to achieve coverage of
the examination volume. The NRC staff
determined that the flaw sizing scan
procedures were adequate because: (1)
Raster scans were conducted at the
higher frequency transducer (increased
resolution) with a range of beam angles
to achieve maximum insonification of
the flaw; (2) focal laws were
programmed for a focal depth equal to
the reported flaw depth; (3) the acquired
data was reviewed to verify that signal
saturation had not occurred or whether
rescanning of the area was necessary to
obtain a response that would allow
accurate flaw sizing; and (4) the flaw
length and flaw height were determined
using prescribed signal thresholds. The
NRC staff determined that the PAUT
minimum attributes for flaw detection
and characterization provided by the
applicant were acceptable and are
commensurate with NRC confirmatory
research findings involving PAUT
examinations of welds (A.A. Diaz, S.L.
Crawford, A.D. Cinson, and M.T.
Anderson, ‘‘Technical Letter Report, An
Evaluation of Ultrasonic Phased Array
Testing for Reactor Piping System
Components Containing Dissimilar
Metal Welds JCN N6398, Task 2A,
PNNL–19018,’’ Richland, WA; Pacific
Northwest National Laboratory,
November 2009).
The NRC staff determined that PAUT
data analysis methods provided by the
applicant were adequate because they
included specific procedures for flaw
detection and flaw sizing necessary to
locate and size flaws in the ITCP and
VerDate Sep<11>2014
15:15 Jun 14, 2016
Jkt 238001
OTCP closure welds using PAUT. The
NRC staff determined that the applicant
demonstrated the accuracy of the PAUT
flaw detection and flaw sizing
procedures using closure welds
mockups with imbedded flaws. The
NRC staff determined that PAUT
procedure contained sufficient detail to
ensure that the examination can be
repeated with similar results and
provides reasonable assurance that the
examination could detect and size flaw
indications found within the closure lid
weld volumes.
The NRC staff reviewed Technical
Report of the Demonstration of UT NDE
Procedure 54–UT–114–000 Phased
Array Ultrasonic Examination of Dry
Storage Canister Lid Welds Technical
Report Document 51–9234641–001,
dated January 30, 2015 (AREVA, INC.,
2015b). This report summarizes the
PAUT performance demonstration on a
second ITCP and OTCP weld mockup
specimen known as the blind mockup.
The report states the overall task
objective is to utilize a PAUT technique
for detection and characterization of
fabrication flaws in the closure lid
welds of DSCs. The developed
procedure was evaluated through a
blind performance demonstration that
included the scanning and data analysis
of a secured (true-state withheld from
examiners) OTCP and ITCP closure
weld mockup. The blind mockup
contained a number of controlled
welding fabrication flaws similar in size
and type to the flaws contained in the
non-blind mockup, but placed in
different locations. The technical report
of the demonstration identified a
calculated probability of detection
(POD) of 97 percent with no missed
detections (i.e., none of the known
imbedded flaws in the blind mockup
were missed in the performance
demonstration) and one false call (i.e.,
one flaw indication reported by an
examiner in the blind performance
demonstration was incorrect and was
not an actual imbedded flaw). As
previously stated, the use of PAUT
procedure to inspect DSC closure lid
welds for this application was
developed in accordance with ASME
B&PV Code Section V, Article 14, T–
1424(b), Intermediate Rigor (ASME 2004
edition). Intermediate rigor requires that
a limited performance demonstration be
conducted achieving a flaw POD of 80
percent and a false call rate of less than
20 percent. The NRC staff finds the
demonstration of PAUT procedure to be
acceptable, because the blind
performance demonstration results
exceed the criteria for acceptable
performance listed in ASME B&PV Code
PO 00000
Frm 00052
Fmt 4703
Sfmt 4703
Section V, Article 14, T–1471
Intermediate Rigor Detection Test
(ASME 2004 edition).
The NRC staff reviewed Monticello
DSC 16 phased array UT examination
results that were used as an input to the
61BTH ITCP and OTCP Closure Weld
Flaw Evaluation CALCULATION
11042–0205, Revision 3 (AREVA, INC.,
2016). The NRC staff determined that
the examination results were acceptable
because:
1. The examination was conducted in
accordance with the PAUT examination
procedure developed in accordance
with ASME B&PV Code Section V,
Article 14, T–1424(b), Intermediate
Rigor (ASME 2004 edition).
2. Flaws identified were appropriately
characterized in terms of flaw length
and flaw height. The PAUT examination
identified the location of the flaws with
respect to the geometric features of the
DSC shell, the ITCP and the OTCP, and
closure lid welds.
3. The largest flaw in the OTCP
closure weld was characterized as
having a height of 0.14 inches which is
not greater than the thickness of one
weld bead and less than the OTCP
closure weld critical flaw size of 0.29
inches.
4. The largest flaw in the ITCP closure
weld was characterized as having a
height of 0.11 inches which is not
greater than the thickness of one weld
bead and less than the ITCP closure
weld critical flaw size of 0.15 inches.
The NRC staff reviewed the preservice
examination requirements of ASME
B&PV Code Section III NB–5280 (ASME
1998 edition with 2000 addenda). The
NRC staff determined that the PAUT
examination results identified and sized
flaws that exceed the acceptance criteria
of NB–5332 (ASME 1998 edition with
2000 addenda), and NB–5332 is an
acceptable approach under ISG–15. The
applicant stated that the flaws identified
by the PAUT examination were
explicitly included in the finite element
models as design features. Further, all
indications found through the PAUT
exam were, according to the applicant,
conservatively characterized as planar
and evaluated as such. The NRC staff
determined that the approach taken by
the applicant is acceptable, because: (1)
The PAUT system was capable of
identifying and sizing the flaws in the
ITCP and OTCP welds with the
exception of small sections of the OTCP
closure weld as a result of longitudinal
welds in the canister shell and the
portion of the ITCP closure weld around
the siphon and vent block; (2) the size
of the flaws used in the analysis
conservatively bounds the size and
distributions of flaws identified by
E:\FR\FM\15JNN1.SGM
15JNN1
ehiers on DSK5VPTVN1PROD with NOTICES
Federal Register / Vol. 81, No. 115 / Wednesday, June 15, 2016 / Notices
PAUT; and (3) the applicant applied a
reduction factor of 0.8 on the ASME
B&PV Code specified minimum
elongations to the weld material to
account for flaws that may not have
been detected by the PAUT
examination.
As a result of the conclusions
discussed above, the NRC staff finds
that there is adequate material
performance of the components
important to safety for DSC 16, loaded
under CoC No. 1004, Amendment No.
10, and that DSC 16, as addressed in the
exemption request, remains in
compliance with 10 CFR part 72.
Structural Review for the Requested
Exemption: The partial-penetration
welds of the canister OTCP and the
ITCP of the Type 1 NUHOMS® 61 BTH
DSCs were originally evaluated in
accordance with the ASME B&PV Code
Section III, Subsection NB code limits.
After the weld repair and verification
activities on DSC 16, the applicant
performed a PAUT examination and
documented volumetrically-identified
flaw indications in the welds. In the
Materials Review for the Requested
Exemption, the staff determined that the
PAUT examination results were
appropriate for analytical modeling. The
results provided a basis for the
applicant to model weld flaw size and
distribution in performing structural
evaluation by analysis. The evaluations
and resulting conclusions to
demonstrate the welds structural
performance is presented below.
AREVA Calculation No. 11042–0204,
Revision 3, ‘‘Allowable Flaw Size
Evaluation in the Inner Top Cover Weld
for DSC # 16,’’ used the ASME B&PV
Code, Section XI, Appendix C flaw
evaluation methodology to compute the
allowable flaw size for governing Load
Case TR–9 of an internal pressure of 20
psi plus a 25-g inertia loading associated
with the DSC corner drop. A theoretical
subsurface crack or an equivalent
surface crack residing in the full
circumference around the 0.25-inch
deep ITCP weld in DSC 16 was assumed
to be subject to the radial tensile
membrane force on the weld. For the
membrane stress of 17.08 ksi resulting
from multiplying the calculated stress of
13.14 ksi with a service factor, SFm, of
1.3 for Service Level D, the applicant
determined a 0.15-inch wide allowable
flaw size. The staff reviewed the
analysis assumptions and concludes
that the flaw size and distribution are
conservatively modeled in accordance
with the ASME B&PV Code Section XI
flaw evaluation methodology to
demonstrate sufficient structural
performance margins in the welds.
VerDate Sep<11>2014
15:15 Jun 14, 2016
Jkt 238001
In Structural Integrity Associates
(SIA) Calculation Package No.
1301415.301, Revision 0, ‘‘Development
of an Analysis Based Stress Allowable
Reduction Factor (SARF), Dry Shielded
Canister (DSC) Top Closure
Weldments,’’ the applicant used a finite
element analysis (FEA) approach to
perform generic evaluation of flaw
effects on the weld stress performance.
Three types of flaw geometry, radial,
circumferential, and laminar flaws for a
range of distribution of flaw length,
depth, and spacing in the DSC ITCP and
OTCP were analyzed. Following a
commonly acceptable FEA practice to
simulate flaws with the elements of near
zero stiffness, the applicant computed
the membrane and membrane-plusbending stress intensities in the welds.
By comparing the results from the FEA
models, with and without flaws, for the
pressure and side drop load cases, a
ratio, or SARF, was determined for each
critical weld section cut of interest. For
the OTCP, the applicant computed
SARFs for 7 flaw configurations each for
the individual pressure and side drop
loading cases. This established a
minimum SARF of greater than 0.7 for
the through-wall circumferential flaws
assumed to span an arc length of 2.016
inches with a common arc spacing of
5.184 inches. From the weld quality
review documented in the SIA report,
No. 1301415.405, ‘‘Expectations for
Field Closure Welds on the AREVA–TN
NUHOMS® 61BTH Type 1 & 2
Transportable Canister for BWR Dry
Fuel Storage,’’ the applicant determined
that only the circumferential flaws are
potentially representative of the weld
condition of the ITCP. This provided the
basis for postulating a 360 degree, 50
percent intermittently embedded,
through-wall circumferential flaw with
a 0.006 in2 cross section area for the
FEA. This resulted in the calculated
SARFs of 0.945 and 0.931 for the
pressure and side drop cases,
respectively. The staff reviewed the
modeling assumptions and FEA results
and concludes that the FEA method is
suitable for analyzing the stress
performance of the weld as a continuum
with multiple embedded flaws.
Using the PAUT flaw indication
examination results, the applicant
performed an FEA to determine the
weld structural performance margins, in
accordance with the ASME Section III
code limits, for the ITCP and OTCP of
DSC 16. As noted in AREVA Calculation
No. 11042–0205, Revision 3, ‘‘61BHT
ITCP and OTCP Closure Weld
Evaluation,’’ two full-circumferential,
bounding flaw sets for the OTCP and
one for the ITCP were used in the
PO 00000
Frm 00053
Fmt 4703
Sfmt 4703
39073
simulation of the flaw indications in the
FEA models. The first set of the two
bounding flaws in the OTCP are 0.14
inches and 0.195 inches each in height
while the second set of the three flaws
range in height from 0.07 inches to 0.16
inches. The single flaw set for the ITCP
consists of two bounding flaws, a 0.09inch high flaw between the weld metal
and the DSC shell and another 0.11-inch
high inside the ITCP, but at close
proximity to the weld metal.
Using an elastic-perfectly plastic
material property model, the applicant
evaluated the top cover plates-to-shell
welds for three governing load cases: (1)
Internal pressure loading of 32 psi for
Service Levels A/B; (2) internal pressure
loading of 65 psi for Service Level D;
and (3) side drop loading of 75 g for
Service Level D. Given that the potential
exists for the weld to undergo material
yielding, the applicant performed a
limit analysis, per the ASME B&PV
Code, Section III, Paragraph NB–3228.1,
‘‘Limit Analysis,’’ provisions, for the
Service Level A/B, normal and offnormal condition load cases.
Correspondingly, the rules of ASME
B&PV Code Section III, Appendix F,
Paragraph F–1341.3, ‘‘Collapse Load,’’
were used for the Service Level D,
accident condition load cases. The limit
analysis, with elastic-perfectly plastic
material model, revealed that the weld
would undergo unbounded deformation
after the material yielding strength is
exceeded.
To address the potential material
rupture associated with large weld
deformation and, hence, high plastic
strain concentrations, the applicant
performed an elastic-plastic analysis to
supplement the determination of the
weld performance margins for DSC 16.
This was accomplished by considering
a Ramberg-Osgood idealization of the
stress-strain curve for SA–240 Type 301
stainless steel, which recognizes strain
hardening effects for the largedeformation FEA models with
embedded flaws in the welds. The
elastic-plastic analyses resulted in the
maximum equivalent plastic strains of
5.97 percent and 6.09 percent for the
Service Level D design pressure of 65
psi and side drop of 75 g, respectively.
The calculated strains are much smaller
than the ASME B&PV Code specified
minimum elongations of SA–240 Type
304 stainless steel at 40 percent and
E308–XX electrode at 35 percent.
Additionally, for a conservative
determination of margins of safety, the
applicant considered a load factor of 1.5
to evaluate the welds subject to a DSC
internal pressure of 100 psi (65 × 1.5 =
97.5 <100 psi) and a side drop of 122.5
g (75 × 1.5 = 122.5 g). The elastic-plastic
E:\FR\FM\15JNN1.SGM
15JNN1
ehiers on DSK5VPTVN1PROD with NOTICES
39074
Federal Register / Vol. 81, No. 115 / Wednesday, June 15, 2016 / Notices
analyses, per the ASME B&PV Code,
Section III, Paragraph NB–3228.3 Plastic
Analysis provisions, resulted in a peak
equivalent plastic strain of 12.6 percent
for both loading cases. On the basis of
the weld material elongation limit of 28
percent, a reduction of the ASME B&PV
Code specified weld elongation limit of
35 percent by a factor 0.8 (0.35 × 0.8 =
0.28), to account for flaws that may not
have been detected by the PAUT
examination, the applicant calculated
the margins of safety of 3.69 and 3.60 for
the internal pressure and side drop
loading cases, respectively.
The NRC staff reviewed the FEA
modeling assumptions and concludes
that the elastic-plastic analysis was
implemented with appropriate loading
conditions and materials properties, as
described above. The analysis results
show that the welds would undergo
plastic deformation for the Service Level
D loading associated with canister
internal pressure and side drop accident
conditions. However, no material
rupture or breach of DSC confinement
boundary at the welds is expected
because of the large margins of safety
against the ASME B&PV Code specified
elongation limits. For this reason, the
staff has reasonable assurance to
conclude that the ITCP and OTCP welds
of DSC 16 have adequate structural
integrity for the normal, off-normal, and
accident and natural phenomenon
conditions. The NRC staff also finds that
the retrievability of DSC 16 is ensured
based on the demonstration of adequate
structural integrity discussed above.
The NRC staff finds that the structural
function of DSC 16, loaded under CoC
No. 1004, Amendment No. 10,
addressed in the exemption request
remains in compliance with 10 CFR part
72.
Thermal Review for the Requested
Exemption: The applicant stated that
even though nonconforming
examinations exist, satisfactory
completion of the required helium leak
test conducted on DSC 16 has
specifically demonstrated the integrity
of the primary confinement boundary
(ITCP and siphon/vent cover plate)
welds. These tests (conducted per TS
1.2.4a) specifically demonstrate that the
primary confinement barrier field welds
are ‘‘leak tight’’ as defined in American
National Standards Institute (ANSI)
N14.5–1997. The licensee stated that, in
this respect, the helium leak test
demonstrates the basic integrity of the
confinement barrier and the lack of a
through-weld flaw in the field closure
welds that would lead to a loss of cavity
helium in DSC 16. The licensee stated
that the field closure welds indirectly
support the thermal design function by
VerDate Sep<11>2014
15:15 Jun 14, 2016
Jkt 238001
virtue of their confinement function (as
demonstrated by the helium leak test
conducted on DSC 16) which assures
the helium atmosphere in the DSC 16
cavity is maintained in order to support
heat transfer.
The NRC staff reviewed the licensee’s
exemption request and also evaluated
its effect on the DSC 16 thermal
performance. The NRC staff concludes
that the cask thermal performance is not
affected by the exemption request
because the applicant has shown that a
satisfactory helium leak test was
conducted on DSC 16, which assures
integrity of the primary confinement
boundary. Integrity of the primary
confinement boundary assures the spent
fuel is stored in a safe inert environment
with unaffected heat transfer
characteristics that assure peak cladding
temperatures remain below allowable
limits. Therefore, based on the NRC
staff’s review of the licensee’s
evaluation and technical justification,
the NRC staff finds the exemption
request acceptable by virtue of the
demonstrable structural integrity of the
ITCP and OTCP.
The NRC staff finds that the thermal
function of DSC 16, loaded under CoC
No. 1004, Amendment No. 10,
addressed in the exemption request
remains in compliance with 10 CFR part
72.
Shielding and Criticality Safety
Review for the Requested Exemption:
The NRC staff reviewed the criticality
safety and radiation protection
effectiveness of DSC 16 presented in the
Monticello exemption request. The NRC
staff finds that DSC 16 is not affected by
the nonconforming PT examinations
because storage of DSC 16 on the MNGP
ISFSI will not significantly alter the
assumptions of the criticality safety and
radiation protection analysis of the
61BTH DSC. The interior of DSC 16 will
continue to prevent water in-leakage,
which means that the system will
remain subcritical under all conditions.
The nonconforming PT examinations do
not affect the radiation source term of
the spent fuel contents, or the
configuration of the shielding
components of the Standardized
NUHOMS® system containing the
61BTH DSC, meaning that the radiation
protection performance of the system is
not altered.
The NRC staff finds that the criticality
safety and shielding function of DSC 16,
loaded under CoC No. 1004,
Amendment No. 10, addressed in the
exemption request remains in
compliance with 10 CFR part 72.
Confinement Review for the
Requested Exemption: The objective of
the confinement evaluation was to
PO 00000
Frm 00054
Fmt 4703
Sfmt 4703
confirm that DSC 16 loaded at the
MNGP met the confinement-related
requirements described in 10 CFR part
72.
As described in the licensee’s
‘‘Exemption Request for Nonconforming
Dry Shielded Canister Dye Penetrant
Examinations’’ (Enclosure 1 of the
September 29, 2015, submittal), certain
elements of the DSC 16 closure weld PT
examinations did not comply with
examination procedures. To support the
exemption request, the licensee noted
that a helium leakage rate test of the
closure’s confinement boundary,
including ITCP weld, siphon cover plate
weld, and vent port cover plate weld,
were conducted per TS 1.2.4a and
demonstrated that the primary
confinement barrier field welds met the
TS acceptance criterion of 1E–7 cc/sec
(i.e., ‘‘leaktight’’ as defined by ANSI
N14.5). The applicant noted that failure
to comply with the PT examination
procedures would not change the
general integrity of these DSC closure
welds. NRC staff concludes that not
performing the PT examination
procedures relevant to this exemption
request would not change the results of
the helium leakage test and, therefore,
the demonstration of the closure
confinement integrity, as defined by the
licensing basis, is unaffected. In
addition, in the Structural Review for
the Requested Exemption and Materials
Review for the Requested Exemption
evaluations described previously, staff
evaluated the applicant’s repair and
verification activities and the PAUT
examinations and analyses associated
with DSC 16 and concluded DSC 16
meets the requirements of 10 CFR part
72.
As discussed above, because the PT
examinations did not affect DSC 16’s
helium leak test results, the NRC staff
finds that the confinement function of
DSC 16, loaded under CoC No. 1004,
Amendment No. 10, remains in
compliance with 10 CFR part 72.
Review of Common Defense and
Security: The NRC staff considered the
potential impacts of granting the
exemption on the common defense and
security. The requested exemption is
not related to any security or common
defense aspect of the MNGP ISFSI,
therefore granting the exemption would
not result in any potential impacts to
common defense and security.
Based on its review, the NRC staff has
reasonable assurance that the storage
system will continue meet the thermal,
structural, criticality, retrievability and
radiation protection requirements of 10
CFR part 72 and, therefore, will not
endanger life or property. The NRC staff
E:\FR\FM\15JNN1.SGM
15JNN1
39075
Federal Register / Vol. 81, No. 115 / Wednesday, June 15, 2016 / Notices
also finds that there is no threat to the
common defense and security.
Therefore, the NRC staff concludes
that the exemption to relieve the
applicant from meeting TS 1.2.5 of
Attachment A of CoC No. 1004,
Amendment No. 10, which requires that
liquid penetrant test examinations be
performed on DSCs to verify the
acceptability of the closure welds,
allowing for transfer DSC 16 into an
HSM, and would permit the continued
storage of that DSC for the service life
of the canister at the MNGP ISFSI will
not endanger life or property or the
common defense and security.
Otherwise in the Public Interest
In considering whether granting the
exemption is in the public interest, the
NRC staff considered the alternative of
not granting the exemption. If the
exemption were not granted, in order to
comply with the CoC, either (1) DSC 16
would have to be opened and unloaded,
and the contents loaded in a new DSC,
and that DSC welded and tested, or (2)
the OTCP would need to be machined
off, and the ITCP weld machined down
to the root weld; and the DSC, ITCP and
OTCP inspected to determine if there
was any damage as a result of the
machining (which would then
necessitate the actions detailed in
option 1). If there were no such damage,
the DSC would need to be re-welded
and inspected. Both options would
entail a higher risk of a cask handling
accidents, additional personnel
exposure, and greater cost to the
applicant. Both options would also
generate additional radioactive
contaminated material (including the
unloaded DSC for option 1) and waste
from operations, because the lid would
have to be removed in either case,
which would generate cuttings from
removing the weld material that could
require disposal as contaminated
material.
The proposed exemption to allow
transfer of DSC 16 into an HSM, and
permit the continued storage of that
DSC for the service life of the canister
at the MNGP ISFSI, is consistent with
NRC’s mission to protect public health
and safety. Approving the requested
exemption produces less of an
opportunity for a release of radioactive
material than the alternatives to the
proposed action because there will be
no operations involving opening the
DSCs which confine the spent nuclear
fuel. Therefore, the exemption is in the
public interest.
Environmental Consideration
The NRC staff also considered in the
review of this exemption request
whether there would be any significant
environmental impacts associated with
the exemption. The NRC staff
determined that this proposed action
fits a category of actions that do not
require an environmental assessment or
environmental impact statement.
Specifically, the exemption meets the
categorical exclusion in 10 CFR
51.22(c)(25).
Granting this exemption from 10 CFR
72.212(a)(2), 72.212(b)(3),
72.212(b)(5)(i), 72.214, and
72.212(b)(11) only relieves the applicant
from the inspection or surveillance
requirements associated with
performing PT examinations with regard
to meeting Technical Specification (TS)
1.2.5 of Attachment A of CoC No. 1004.
A categorical exclusion for inspection or
surveillance requirements is provided
under 10 CFR 51.22(c)(25)(vi)(C) if the
criteria in 10 CFR 51.22(c)(25)(i)–(v) are
also satisfied. In its review of the
exemption request, the NRC staff
determined, as discussed above, that,
under 10 CFR 51.22(c)(25): (i) Granting
the exemption does not involve a
significant hazards considerations
because granting the exemption neither
reduces a margin of safety, creates a new
or different kind of accident from any
accident previously evaluated, nor
significantly increases either the
probability or consequences of an
accident previously evaluated; (ii)
granting the exemption would not
produce a significant change in either
the types or amounts of any effluents
that may be released offsite because the
requested exemption neither changes
the effluents nor produces additional
avenues of effluent release; (iii) granting
the exemption would not result in a
significant increase in either
occupational radiation exposure or
public radiation exposure, because the
requested exemption neither introduces
new radiological hazards nor increases
existing radiological hazards; (iv)
granting the exemption would not result
in a significant construction impact,
because there are no construction
activities associated with the requested
exemption; and; (v) granting the
exemption would not increase either the
potential or consequences from
radiological accidents such as a gross
leak from the closure welds, because the
exemption neither reduces the ability of
the closure welds to confine radioactive
material nor creates new accident
precursors at the MNGP ISFSI.
Accordingly, this exemption meets the
criteria for a categorical exclusion in 10
CFR 51.22(c)(25)(vi)(C).
IV. Availability of Documents
The documents identified in the
following table are available to
interested persons through one or more
of the following methods, as indicated.
ADAMS
Accession No.
Document
Monticello Nuclear Generating Plant Exemption Request for Nonconforming Dry Shielded Canister Dye Penetrant Examinations, September 29, 2015.
Monticello Nuclear Generating Plant Exemption Request for Nonconforming Dry Shielded Canister Dye Penetrant Examinations, Supplemental Information, January 29, 2016.
ehiers on DSK5VPTVN1PROD with NOTICES
Monticello Nuclear Generating Plant Exemption Request for Nonconforming Dry Shielded Canister Dye Penetrant Examinations, Supplemental Information to Respond to the Second Request for Additional Information, March 29, 2016.
Interim Staff Guidance No. 15, Rev. 0, Materials Evaluation, January 10, 2001 ............................................................................
Technical Justification for Phased Array Ultrasonic Examination of Dry Storage Canister Lid Welds Report No. 54–PQ–114–
001, January 30, 2015.
Technical Report of the Demonstration of UT NDE Procedure 54–UT–114–000 Phased Array Ultrasonic Examination of Dry
Storage Canister Lid Welds Report No. 51–9234641–001, January 30, 2015.
61BTH ITCP and OTCP closure Weld Flaw Evaluation, Calculation 11042–0205, Revision 3, March 21, 2016 ..........................
Technical Letter Report, An Evaluation of Ultrasonic Phased Array Testing for Reactor Piping System Components Containing
Dissimilar Metal Welds JCN N6398, Task 2A, PNNL–19018,’’ Richland, WA; Pacific Northwest National Laboratory, November 2009.
VerDate Sep<11>2014
15:15 Jun 14, 2016
Jkt 238001
PO 00000
Frm 00055
Fmt 4703
Sfmt 4703
E:\FR\FM\15JNN1.SGM
15JNN1
ML15275A023
ML15275A024
ML15275A025
ML16035A214
ML16049A081
ML16049A094
ML16091A228
ML16097A460
ML010100170
ML16035A185
ML16035A186
ML16049A094
ML16035A184
ML16097A460
ML093570315
39076
Federal Register / Vol. 81, No. 115 / Wednesday, June 15, 2016 / Notices
ADAMS
Accession No.
Document
AREVA Calculation No. 11042–0204, Revision 3, Allowable Flaw Size Evaluation in the Inner Top Cover Weld for DSC #16,
September 29, 2015.
Structural Integrity Associates Calculation Package No. 1301415.301, Revision 0, Development of an Analysis Based Stress
Allowable Reduction Factor (SARF), Dry Shielded Canister (DSC) Top Closure Weldments, October 2014.
Structural Integrity Associates report, No. 1301415.405, Expectations for Field Closure Welds on the AREVA–TN NUHOMS®
61BTH Type 1 & 2 Transportable Canister for BWR Dry Fuel Storage, November 3, 2014.
IV. Conclusion
FOR FURTHER INFORMATION CONTACT:
Based on the foregoing
considerations, the NRC staff has
determined that, pursuant to 10 CFR
72.7, the exemption is authorized by
law, will not endanger life or property
or the common defense and security,
and is otherwise in the public interest.
Therefore, the NRC grants the applicant
an exemption from the requirements of
10 CFR 72.212(a)(2), 72.212(b)(3),
72.212(b)(5)(i), 72.214, and
72.212(b)(11), only with regard to
meeting Technical Specification (TS)
1.2.5 of Attachment A of CoC No. 1004
for DSC 16.
This exemption is effective upon
issuance.
Dated at Rockville, Maryland, this 8th day
June, 2016.
For the Nuclear Regulatory Commission.
Bernie White,
Acting Branch Chief, Spent Fuel Licensing
Branch, Division of Spent Fuel Management,
Office of Nuclear Material Safety and
Safeguards.
[FR Doc. 2016–14188 Filed 6–14–16; 8:45 am]
BILLING CODE 7590–01–P
POSTAL REGULATORY COMMISSION
[Docket No. CP2016–194]
New Postal Product
Postal Regulatory Commission.
Notice.
AGENCY:
ACTION:
The Commission is noticing a
recent Postal Service filing for the
Commission’s consideration concerning
a negotiated service agreement. This
notice informs the public of the filing,
invites public comment, and takes other
administrative steps.
DATES: Comments are due: June 17,
2016.
SUMMARY:
Submit comments
electronically via the Commission’s
Filing Online system at https://
www.prc.gov. Those who cannot submit
comments electronically should contact
the person identified in the FOR FURTHER
INFORMATION CONTACT section by
telephone for advice on filing
alternatives.
ehiers on DSK5VPTVN1PROD with NOTICES
ADDRESSES:
VerDate Sep<11>2014
15:15 Jun 14, 2016
Jkt 238001
David A. Trissell, General Counsel, at
202–789–6820.
SUPPLEMENTARY INFORMATION:
Table of Contents
I. Introduction
II. Docketed Proceeding(s)
I. Introduction
The Commission gives notice that the
Postal Service has filed request(s) for the
Commission to consider matters related
to negotiated service agreement(s). The
requests(s) may propose the addition or
removal of a negotiated service
agreement from the market dominant or
the competitive product list, or the
modification of an existing product
currently appearing on the market
dominant or the competitive product
list.
Section II identifies the docket
number(s) associated with each Postal
Service request, the title of each Postal
Service request, the request’s acceptance
date, and the authority cited by the
Postal Service for each request. For each
request, the Commission appoints an
officer of the Commission to represent
the interests of the general public in the
proceeding, pursuant to 39 U.S.C. 505
(Public Representative). Section II also
establishes comment deadline(s)
pertaining to each request.
The public portions of the Postal
Service’s request(s) can be accessed via
the Commission’s Web site (https://
www.prc.gov). Non-public portions of
the Postal Service’s request(s), if any,
can be accessed through compliance
with the requirements of 39 CFR
3007.40.
The Commission invites comments on
whether the Postal Service’s request(s)
in the captioned docket(s) are consistent
with the policies of title 39. For
request(s) that the Postal Service states
concern market dominant product(s),
applicable statutory and regulatory
requirements include 39 U.S.C. 3622, 39
U.S.C. 3642, 39 CFR part 3010, and 39
CFR part 3020, subpart B. For request(s)
that the Postal Service states concern
competitive product(s), applicable
statutory and regulatory requirements
include 39 U.S.C. 3632, 39 U.S.C. 3633,
39 U.S.C. 3642, 39 CFR part 3015, and
PO 00000
Frm 00056
Fmt 4703
Sfmt 4703
ML15275A024
ML15275A025
ML14309A194
39 CFR part 3020, subpart B. Comment
deadline(s) for each request appear in
section II.
II. Docketed Proceeding(s)
1. Docket No(s).: CP2016–194; Filing
Title: Notice of the United States Postal
Service of Filing a Functionally
Equivalent Global Plus 1C Negotiated
Service Agreement and Application for
Non-Public Treatment of Materials Filed
Under Seal; Filing Acceptance Date:
June 9, 2016; Filing Authority: 39 U.S.C.
3642 and 39 CFR 3020.30 et seq.; Public
Representative: Kenneth R. Moeller;
Comments Due: June 17, 2016.
This notice will be published in the
Federal Register.
Stacy L. Ruble,
Secretary.
[FR Doc. 2016–14172 Filed 6–14–16; 8:45 am]
BILLING CODE 7710–FW–P
OFFICE OF SCIENCE AND
TECHNOLOGY POLICY
Request for Information on the
Development of the 2017 National Plan
for Civil Earth Observations;
Correction
Notice of Request for
Information (RFI); correction.
ACTION:
On June 2, 2016, the White
House Office of Science and Technology
Policy (OSTP) published a document in
the Federal Register (81 FR 35398)
requesting information on development
of the 2017 National Plan for Civil Earth
Observations. That document contained
one error in an OSTP email address, and
in one of the listed phone numbers.
OSTP is therefore reissuing this
document with the corrected
information.
On behalf of the U.S. Group on Earth
Observations (USGEO), a Subcommittee
of the National Science and Technology
Council (NSTC) Committee on
Environment, Natural Resources, and
Sustainability (CENRS), OSTP requests
input from all interested parties
regarding recommendations for the
development of the 2017 National Plan
for Civil Earth Observations (‘‘National
Plan’’, or ‘‘Plan’’). An electronic
SUMMARY:
E:\FR\FM\15JNN1.SGM
15JNN1
Agencies
[Federal Register Volume 81, Number 115 (Wednesday, June 15, 2016)]
[Notices]
[Pages 39069-39076]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 2016-14188]
=======================================================================
-----------------------------------------------------------------------
NUCLEAR REGULATORY COMMISSION
[Docket Nos. 72-58 and 50-263; NRC-2016-0115]
Xcel Energy, Monticello Nuclear Generating Plant Independent
Spent Fuel Storage Installation
AGENCY: Nuclear Regulatory Commission.
ACTION: Exemption; issuance.
-----------------------------------------------------------------------
SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) is issuing an
exemption in response to a request submitted by Xcel Energy on
September 29, 2015, from meeting Technical Specification (TS) 1.2.5 of
Attachment A of Certificate of Compliance (CoC) No. 1004, Amendment No.
10, which requires that all dry shielded canister (DSC) closure welds,
except those subjected to full volumetric inspection, shall be dye
penetrant tested in accordance with the requirements of American
Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel
(B&PV) Code Section III, Division 1, Article NB-5000. This exemption
applies to one loaded Standardized NUHOMS[supreg] 61BTH, DSC 16 (DSC
16), at the Monticello Nuclear Generating Plant (MNGP) Independent
Spent Fuel Storage Installation (ISFSI).
ADDRESSES: Please refer to Docket ID NRC-2016-0115 when contacting the
NRC about the availability of information regarding this document. You
may obtain publicly-available information related to this document
using any of the following methods:
Federal Rulemaking Web site: Go to https://www.regulations.gov and search for Docket ID NRC-2016-0115. Address
questions about NRC dockets to Carol Gallagher; telephone: 301-415-
3463; email: Carol.Gallagher@nrc.gov. For technical questions, contact
the individual listed in the FOR FURTHER INFORMATION CONTACT section of
this document.
NRC's Agencywide Documents Access and Management System
(ADAMS): You may obtain publicly-available documents online in the
ADAMS Public Documents collection at https://www.nrc.gov/reading-rm/adams.html. To begin the search, select ``ADAMS Public Documents'' and
then select ``Begin Web-based ADAMS Search.'' For problems with ADAMS,
please contact the NRC's Public Document Room (PDR) reference staff at
1-800-397-4209, 301-415-4737, or by email to pdr.resource@nrc.gov. For
the convenience of the reader, the ADAMS accession numbers are provided
in a table in the ``Availability of Documents'' section of this
document.
NRC's PDR: You may examine and purchase copies of public
documents at the NRC's PDR, Room O1-F21, One White Flint North, 11555
Rockville Pike, Rockville, Maryland 20852.
FOR FURTHER INFORMATION CONTACT: Christian Jacobs, Office of Nuclear
Material Safety and Safeguards, U.S. Nuclear Regulatory Commission,
Washington, DC 20555-0001; telephone: 301-415-6825; email:
Christian.Jacobs@nrc.gov.
SUPPLEMENTARY INFORMATION:
I. Background
Northern States Power Company-Minnesota, doing business as Xcel
Energy (Xcel Energy, or the applicant) is the holder of Facility
Operating License No. DPR-22, which authorizes operation of the
Monticello Nuclear Generating Plant (MNGP), Unit No. 1, in Wright
County, Minnesota, pursuant to part 50 of title 10 of the Code of
Federal Regulations (10 CFR), ``Domestic Licensing of Production and
Utilization Facilities.'' The license provides, among other things,
that the facility is subject to all rules, regulations, and orders of
the NRC now or hereafter in effect.
Consistent with 10 CFR part 72, subpart K, ``General License for
Storage of Spent Fuel at Power Reactor Sites,'' a general license is
issued for the storage of spent fuel in an ISFSI at power reactor sites
to persons authorized to possess or operate nuclear power reactors
under 10 CFR part 50. The applicant is authorized to operate a nuclear
power reactor under 10 CFR part 50, and holds a 10 CFR part 72 general
license for storage of spent fuel at the Monticello Nuclear Generating
Plant ISFSI. Under the terms of the general license, the applicant
stores spent fuel at its ISFSI using the Transnuclear, Inc. (TN)
Standardized NUHOMS[supreg] dry cask storage system Certificate of
Compliance (CoC) No. 1004, Amendments No. 9 and No. 10. As part of the
dry storage system, the DSC (of which the closure welds are an integral
part) ensures that the dry storage system can meet the functions of
criticality safety, confinement boundary, shielding, structural
support, and heat transfer.
II. Request/Action
The applicant has requested an exemption from the requirements of
10 CFR 72.212(b)(3) and 10 CFR 72.212(b)(11) that require compliance
with the terms, conditions, and specifications of CoC No. 1004,
Amendment No. 10, for the Standardized NUHOMS[supreg] Horizontal
Modular Storage System, to the extent necessary for the applicant to
transfer DSC 16 into a Horizontal Storage Module (HSM). This would
permit the continued storage of that DSC for the service life of the
canister. Specifically, the exemption would relieve the applicant from
meeting TS 1.2.5 of Attachment A of CoC No. 1004, which requires that
all DSC closure welds, except those subjected to full volumetric
inspection, shall be dye penetrant tested in accordance with the
requirements of the ASME B&PV Code Section III, Division 1, Article NB-
5000. Technical Specification 1.2.5 further requires that the liquid
penetrant test acceptance standards shall be those described in
Subsection NB-5350 of the ASME BP&V Code.
Xcel Energy loaded spent nuclear fuel into six 61BTH DSCs starting
in September 2013. Subsequent to the loading, it was discovered that
certain elements of the liquid penetrant test (PT) examinations, which
were performed on the DSCs to verify the acceptability of the closure
welds, do not comply with the requirements of TS 1.2.5. All six DSCs
were affected. Five of the six DSCs (numbers 11-15) had already been
loaded in the HSMs when the discrepancies were discovered. The DSC 16
remains on the reactor building refueling floor in a transfer cask
(TC).
[[Page 39070]]
Xcel Energy has performed phased array ultrasonic testing (PAUT) of the
closure welds, supported by analysis, as an alternate means for
verifying the weld quality. The PAUT nondestructive examination (NDE)
consists of testing performed by qualified personnel, using specific
procedures and equipment shown by performance demonstration to be
sufficient to detect the range of potential weld defects that could be
present in the closure welds. The exemption request, if approved, would
allow the transfer of DSC 16 into an HSM, and would permit the
continued storage of that DSC for the service life of the canister.
Xcel Energy plans to request a separate exemption for the remaining
DSCs (11-15).
In a letter dated September 29, 2015, as supplemented January 29,
2016, and March 29, 2016, the applicant requested an exemption from
certain parts of the following requirements to allow storage of the DSC
at the MNGP ISFSI:
10 CFR 72.212(b)(3), which states that the general
licensee must ensure that each cask used by the general licensee
conforms to the terms, conditions, and specifications of a CoC or an
amended CoC listed in Sec. 72.214.
10 CFR 72.212(b)(11), which states, in part, that the
licensee shall comply with the terms, conditions, and specifications of
the CoC and, for those casks to which the licensee has applied the
changes of an amended CoC, the terms, conditions, and specifications of
the amended CoC.
Upon review, in addition to the requirements from which the
applicant requested exemption, the NRC staff determined that exemptions
from the following requirements are also necessary in order to
authorize the applicant's request and added the following requirements
to the exemption for the proposed action pursuant to its authority
under 10 CFR 72.7, ``Specific exemptions'':
10 CFR 72.212(a)(2), which states that this general
license is limited to storage of spent fuel in casks approved under the
provisions of this part.
10 CFR 72.212(b)(5)(i), which requires that the general
licensee perform written evaluations, before use and before applying
the changes authorized by an amended CoC to a cask loaded under the
initial CoC or an earlier amended CoC, which establish that the cask,
once loaded with spent fuel or once the changes authorized by an
amended CoC have been applied, will conform to the terms, conditions,
and specifications of a CoC or an amended CoC listed in Sec. 72.214.
10 CFR 72.214, which lists the approved spent fuel storage
casks.
III. Discussion
Pursuant to 10 CFR 72.7, the Commission may, upon application by
any interested person or upon its own initiative, grant such exemptions
from the requirements of the regulations of 10 CFR part 72 as it
determines are authorized by law and will not endanger life or property
or the common defense and security and are otherwise in the public
interest.
Authorized by Law
This exemption would allow the applicant to transfer DSC 16 into an
HSM, and would permit the continued storage of that DSC at the MNGP
ISFSI for the service life of the canister by relieving the applicant
of the requirement to meet the liquid penetrant test requirements of TS
1.2.5 of Attachment A of CoC No. 1004. The provisions in 10 CFR part 72
from which the applicant is requesting exemption, as well as provisions
determined to be applicable by the NRC staff, require the licensee to
comply with the terms, conditions, and specifications of the CoC for
the approved cask model it uses. Section 72.7 allows the NRC to grant
exemptions from the requirements of 10 CFR part 72. As explained below,
the proposed exemption will not endanger life or property, or the
common defense and security, and is otherwise in the public interest.
Issuance of this exemption is consistent with the Atomic Energy Act of
1954, as amended, and not otherwise inconsistent with NRC's regulations
or other applicable laws. Therefore, the exemption is authorized by
law.
Will Not Endanger Life or Property or the Common Defense and Security
This exemption would relieve the applicant from meeting TS 1.2.5 of
Attachment A of CoC No. 1004, which requires liquid penetrant test
examinations to be performed on the DSCs to verify the acceptability of
the closure welds, allowing for transfer of DSC 16 into an HSM, and
would permit the continued storage of that DSC at the MNGP ISFSI for
the service life of the canister. This exemption only addresses DSC 16,
for which the PT test was not performed in accordance with the
examination procedures specified in TS 1.2.5. Xcel Energy performed
phased array ultrasonic testing to nondestructively examine the welds,
and prepared structural analyses based on the actual weld quality to
verify that the welds would perform their desired function over the
storage term of the DSC. As detailed below, NRC staff reviewed the
exemption request to determine whether granting of the exemption would
cause potential for danger to life, property, or common defense and
security.
Review of the Requested Exemption
The NUHOMS[supreg] system provides horizontal dry storage of
canisterized spent fuel assemblies in an HSM. The cask storage system
components for NUHOMS[supreg] consist of a reinforced concrete HSM and
a DSC vessel with an internal basket assembly that holds the spent fuel
assemblies. The HSM is a low-profile, reinforced concrete structure
designed to withstand all normal condition loads, as well as abnormal
condition loads created by natural phenomena such as earthquakes and
tornadoes. It is also designed to withstand design basis accident
conditions. The Standardized NUHOMS[supreg] Horizontal Modular Storage
System has been approved for storage of spent fuel under the conditions
of Certificate of Compliance No. 1004. The DSC under consideration for
exemption was loaded under Certificate of Compliance No. 1004,
Amendment No. 10.
The NRC has previously approved the Standardized NUHOMS[supreg]
Horizontal Modular Storage System. The requested exemption does not
change the fundamental design, components, contents, or safety features
of the storage system. The NRC staff has evaluated the applicable
potential safety impacts of granting the exemption to assess the
potential for danger to life or property or the common defense and
security; the evaluation and resulting conclusions are presented below.
The potential impacts identified for this exemption request were in the
areas of materials, structural integrity, thermal, shielding, and
confinement capability.
Materials Review for the Requested Exemption: The applicant
asserted that there is reasonable assurance of safety for the requested
exemption for the transfer of DSC 16 to the MNGP ISFSI pad. The
applicant's assertion of reasonable assurance of safety for the
transfer of DSC 16 is based on the following:
Repair and verification activities performed on DSC 16;
PAUT examination and analysis of accessible lid welds on
DSC 16;
Short duration and haul distance of the transfer of DSC
16, and
The safest location for DSC 16 is in the HSM.
The applicant asserts that there is a reasonable assurance of
safety for the requested exemption for DSC 16 (CoC
[[Page 39071]]
No. 1004, Amendment 10) based on the following:
Integrity of the fuel (cladding) creates a fission product
barrier;
The quality of the welding process employed provides
indication of development of quality welds;
The advantages of the multi-layer weld technique which
includes the low probability for flaw propagation, the subsequent
covering of weld layer surface flaws and the indication of development
of quality welds;
Visual inspections performed on the welds met quality
requirements;
The DSC backfill and helium leak testing results verify
confinement barrier integrity;
The lack of a failure mechanism that adversely affects
confinement barrier integrity; and
Margin of safety is available in the welds when assuming
conservatively large flaws. These margins are demonstrated by two
different methods: (1) Structural analysis using an analysis-based
Stress Allowance Reduction Factor and theoretically-bounding full-
circumferential flaws, and (2) a finite element analysis assuming flaw
distributions conservatively derived from PAUT examination.
The applicant stated that the PAUT examination and analysis
provides an objective review of volumetrically-identified flaw
indications in the accessible DSC 16 Inner Top Cover Plate (ITCP) and
Outer Top Cover Plate (OTCP) closure welds. The peak strains in the
welds remain well below the weld material ductility limit when
subjected to the accident pressure and drop loads. The peak strains
have a margin of safety of 3.69 and 3.60 for accident pressure and drop
loads, respectively. Furthermore, it was shown that the strains in the
welds remain stable at 150 percent of the original design loads for the
NUHOMS[supreg] 61BTH DSC. The applicant's analysis accounted for the
identified ITCP and OTCP closure weld flaws and the uncertainties in
the PAUT examination. The applicant stated that this approach, which is
consistent with the NRC's Spent Fuel Project Office Interim Staff
Guidance-15 (ISG-15), conservatively accounts for any additional
limitations in the efficacy of the PAUT examinations and also accounts
for the inaccessible area around the vent and siphon block as well as
the geometric reflectors at the root and near the toe of the closure
welds.
The applicant noted that the proposed exemption applies only to DSC
16 and is supported by the following reports:
1. Technical Justification for Phased Array Ultrasonic Examination
of Dry Storage Canister Lid Welds Report No. 54-PQ-114-001, January 30,
2015 (AREVA, INC., 2015a).
2. Technical Report of the Demonstration of UT NDE Procedure 54-UT-
114-000 Phased Array Ultrasonic Examination of Dry Storage Canister Lid
Welds Report No. 51-9234641-001, January 30, 2015 (AREVA, INC., 2015b).
3. 61BTH ITCP and OTCP Closure Weld Flaw Evaluation, Calculation
11042-0205 Revision 3 (AREVA, INC., 2016).
The NRC staff reviewed Technical Justification for Phased Array
Ultrasonic Examination of Dry Storage Canister Lid Welds Report No. 54-
PQ-114-001, dated January 30, 2015 (AREVA, INC., 2015a). This report
provides the detailed technical justification for the use of the PAUT
system to perform the NDE of the OTCP and ITCP closure welds of DSC 16.
The NRC staff determined that the technical justification report was
adequate to justify the use of PAUT to examine the ITCP and OTCP
closure welds because the report included detailed information on the
PAUT system design, an assessment of examination sensitivity, flaw
detection, flaw sizing, identification and effects of influential
parameters, personnel qualification requirements, components to be
examined, flaws to be detected, and analysis of flaw detection and flaw
sizing data. In addition, the NRC staff determined that the report also
described extensive modeling performed to evaluate PAUT array
configuration, element arrangements, apertures, frequency, focusing,
and beam angles to develop probes for the inspections of the ITCP and
OTCP closure welds. The NRC staff also confirmed that the performance
of the PAUT system was evaluated using laboratory testing of
representative mockup containing 22 typical welding manufacturing flaws
that have the potential to exist in field welds. The NRC staff
determined that the laboratory testing was adequate to verify the
performance of PAUT systems because the non-blind mockup contained
representative ITCP and OTCP closure welds with controlled placement of
intentional flaws positioned in difficult detection locations such as
in the weld root and weld toe regions and were generally small in size.
The NRC staff also reviewed ISG-15, which states that closure lid
welds examined by ultrasonic testing (UT) must use UT acceptance
criteria of NB-5332 for pre-service examination and be performed in
conjunction with the PT of the root and final pass. The ISG-15 also
states that if progressive PT examination is used without a volumetric
examination, a stress reduction factor of 0.8 is to be imposed on the
weld design.
The NRC staff determined that the reduction factor of 0.8
considered by the applicant in their finite element analysis is
sufficient to account for weld flaws that potentially were not detected
by PAUT, visual inspection and the compliant PT inspection of the OTCP
final weld pass. The NRC staff reached this determination based on the
demonstrated ability of the PAUT examination to detect weld flaws on
both the ITCP and OTCP closure welds including the root pass and the
final pass shown in the technical justification of using PAUT to
examine the DSC lid closure welds (AREVA, INC., 2015b). The NRC staff
noted that the PAUT examination results of the OTCP weld are consistent
with the PT examination of the OTCP closure weld final pass after
repair and confirmed that no surface breaking flaws are present. Thus,
the NRC staff determined that analytical evaluation of the DSC 16 OTCP
and ITCP closure welds using the flaw sizing results obtained by the
PAUT examination, combined with the discount of the ASME B&PV Code
specified minimum elongations for the weld material, is an appropriate
method to determine the acceptability of the DSC inner and outer lid to
shell closure welds.
The NRC staff determined that the PAUT procedure (AREVA, INC.,
2016) was acceptable because the procedure was qualified using a blind
performance demonstration in accordance with ASME B&PV Code Section V,
Article 14, T-1424(b) Intermediate Rigor (ASME 2004 edition) that
qualifies the equipment, procedure, and data analysis personnel for the
detection and dimensioning of welding fabrication flaws. The NRC staff
determined that PAUT procedures were also acceptable because: (1)
Personnel conducting the equipment calibration, data acquisition or
data analyses must be qualified by the American Society for
Nondestructive Testing (ASNT); (2) the examination area includes the
accessible area of the ITCP and OTCP closure welds, and (3) specific
procedures were developed and demonstrated for both flaw detection and
flaw sizing scans. The NRC staff determined that the examinations were
appropriate because: (1) They included >99 percent of the OTCP closure
weld with the exception of two (2) 0.5-inch long sections that were
identified as limited examination areas as a result of the two
longitudinal welds in the canister shell; and (2) the entire ITCP
[[Page 39072]]
closure weld with the exception of the part of the weld located around
the siphon and vent port block resulting in >90 percent coverage of the
ITCP closure weld (AREVA, INC., 2016). The NRC staff determined that
the personnel qualifications for equipment calibration, data
acquisition and data analysis are sufficient because: (1) Data
Acquisition Operators require direct supervision of American Society
for Nondestructive Testing (ASNT) UT Level II or Level III staff; (2)
both Calibration Personnel and Data Analysis Personnel were required to
be either ASNT UT Level II or Level III certification; and (3) lead
personnel responsible for training and review of flaw indications were
required to be ASNT UT Level III qualified. The NRC staff determined
that the procedures for the flaw detection scans were adequate,
because: (1) The procedures used the known geometric features of the
DSC to identify the correct position of the transducer for complete
coverage of the closure welds to be examined; and (2) the beams are
swept through a range of angles at specified increments along the scan
line in order to achieve coverage of the examination volume. The NRC
staff determined that the flaw sizing scan procedures were adequate
because: (1) Raster scans were conducted at the higher frequency
transducer (increased resolution) with a range of beam angles to
achieve maximum insonification of the flaw; (2) focal laws were
programmed for a focal depth equal to the reported flaw depth; (3) the
acquired data was reviewed to verify that signal saturation had not
occurred or whether rescanning of the area was necessary to obtain a
response that would allow accurate flaw sizing; and (4) the flaw length
and flaw height were determined using prescribed signal thresholds. The
NRC staff determined that the PAUT minimum attributes for flaw
detection and characterization provided by the applicant were
acceptable and are commensurate with NRC confirmatory research findings
involving PAUT examinations of welds (A.A. Diaz, S.L. Crawford, A.D.
Cinson, and M.T. Anderson, ``Technical Letter Report, An Evaluation of
Ultrasonic Phased Array Testing for Reactor Piping System Components
Containing Dissimilar Metal Welds JCN N6398, Task 2A, PNNL-19018,''
Richland, WA; Pacific Northwest National Laboratory, November 2009).
The NRC staff determined that PAUT data analysis methods provided
by the applicant were adequate because they included specific
procedures for flaw detection and flaw sizing necessary to locate and
size flaws in the ITCP and OTCP closure welds using PAUT. The NRC staff
determined that the applicant demonstrated the accuracy of the PAUT
flaw detection and flaw sizing procedures using closure welds mockups
with imbedded flaws. The NRC staff determined that PAUT procedure
contained sufficient detail to ensure that the examination can be
repeated with similar results and provides reasonable assurance that
the examination could detect and size flaw indications found within the
closure lid weld volumes.
The NRC staff reviewed Technical Report of the Demonstration of UT
NDE Procedure 54-UT-114-000 Phased Array Ultrasonic Examination of Dry
Storage Canister Lid Welds Technical Report Document 51-9234641-001,
dated January 30, 2015 (AREVA, INC., 2015b). This report summarizes the
PAUT performance demonstration on a second ITCP and OTCP weld mockup
specimen known as the blind mockup. The report states the overall task
objective is to utilize a PAUT technique for detection and
characterization of fabrication flaws in the closure lid welds of DSCs.
The developed procedure was evaluated through a blind performance
demonstration that included the scanning and data analysis of a secured
(true-state withheld from examiners) OTCP and ITCP closure weld mockup.
The blind mockup contained a number of controlled welding fabrication
flaws similar in size and type to the flaws contained in the non-blind
mockup, but placed in different locations. The technical report of the
demonstration identified a calculated probability of detection (POD) of
97 percent with no missed detections (i.e., none of the known imbedded
flaws in the blind mockup were missed in the performance demonstration)
and one false call (i.e., one flaw indication reported by an examiner
in the blind performance demonstration was incorrect and was not an
actual imbedded flaw). As previously stated, the use of PAUT procedure
to inspect DSC closure lid welds for this application was developed in
accordance with ASME B&PV Code Section V, Article 14, T-1424(b),
Intermediate Rigor (ASME 2004 edition). Intermediate rigor requires
that a limited performance demonstration be conducted achieving a flaw
POD of 80 percent and a false call rate of less than 20 percent. The
NRC staff finds the demonstration of PAUT procedure to be acceptable,
because the blind performance demonstration results exceed the criteria
for acceptable performance listed in ASME B&PV Code Section V, Article
14, T-1471 Intermediate Rigor Detection Test (ASME 2004 edition).
The NRC staff reviewed Monticello DSC 16 phased array UT
examination results that were used as an input to the 61BTH ITCP and
OTCP Closure Weld Flaw Evaluation CALCULATION 11042-0205, Revision 3
(AREVA, INC., 2016). The NRC staff determined that the examination
results were acceptable because:
1. The examination was conducted in accordance with the PAUT
examination procedure developed in accordance with ASME B&PV Code
Section V, Article 14, T-1424(b), Intermediate Rigor (ASME 2004
edition).
2. Flaws identified were appropriately characterized in terms of
flaw length and flaw height. The PAUT examination identified the
location of the flaws with respect to the geometric features of the DSC
shell, the ITCP and the OTCP, and closure lid welds.
3. The largest flaw in the OTCP closure weld was characterized as
having a height of 0.14 inches which is not greater than the thickness
of one weld bead and less than the OTCP closure weld critical flaw size
of 0.29 inches.
4. The largest flaw in the ITCP closure weld was characterized as
having a height of 0.11 inches which is not greater than the thickness
of one weld bead and less than the ITCP closure weld critical flaw size
of 0.15 inches.
The NRC staff reviewed the preservice examination requirements of
ASME B&PV Code Section III NB-5280 (ASME 1998 edition with 2000
addenda). The NRC staff determined that the PAUT examination results
identified and sized flaws that exceed the acceptance criteria of NB-
5332 (ASME 1998 edition with 2000 addenda), and NB-5332 is an
acceptable approach under ISG-15. The applicant stated that the flaws
identified by the PAUT examination were explicitly included in the
finite element models as design features. Further, all indications
found through the PAUT exam were, according to the applicant,
conservatively characterized as planar and evaluated as such. The NRC
staff determined that the approach taken by the applicant is
acceptable, because: (1) The PAUT system was capable of identifying and
sizing the flaws in the ITCP and OTCP welds with the exception of small
sections of the OTCP closure weld as a result of longitudinal welds in
the canister shell and the portion of the ITCP closure weld around the
siphon and vent block; (2) the size of the flaws used in the analysis
conservatively bounds the size and distributions of flaws identified by
[[Page 39073]]
PAUT; and (3) the applicant applied a reduction factor of 0.8 on the
ASME B&PV Code specified minimum elongations to the weld material to
account for flaws that may not have been detected by the PAUT
examination.
As a result of the conclusions discussed above, the NRC staff finds
that there is adequate material performance of the components important
to safety for DSC 16, loaded under CoC No. 1004, Amendment No. 10, and
that DSC 16, as addressed in the exemption request, remains in
compliance with 10 CFR part 72.
Structural Review for the Requested Exemption: The partial-
penetration welds of the canister OTCP and the ITCP of the Type 1
NUHOMS[supreg] 61 BTH DSCs were originally evaluated in accordance with
the ASME B&PV Code Section III, Subsection NB code limits. After the
weld repair and verification activities on DSC 16, the applicant
performed a PAUT examination and documented volumetrically-identified
flaw indications in the welds. In the Materials Review for the
Requested Exemption, the staff determined that the PAUT examination
results were appropriate for analytical modeling. The results provided
a basis for the applicant to model weld flaw size and distribution in
performing structural evaluation by analysis. The evaluations and
resulting conclusions to demonstrate the welds structural performance
is presented below.
AREVA Calculation No. 11042-0204, Revision 3, ``Allowable Flaw Size
Evaluation in the Inner Top Cover Weld for DSC # 16,'' used the ASME
B&PV Code, Section XI, Appendix C flaw evaluation methodology to
compute the allowable flaw size for governing Load Case TR-9 of an
internal pressure of 20 psi plus a 25-g inertia loading associated with
the DSC corner drop. A theoretical subsurface crack or an equivalent
surface crack residing in the full circumference around the 0.25-inch
deep ITCP weld in DSC 16 was assumed to be subject to the radial
tensile membrane force on the weld. For the membrane stress of 17.08
ksi resulting from multiplying the calculated stress of 13.14 ksi with
a service factor, SFm, of 1.3 for Service Level D, the
applicant determined a 0.15-inch wide allowable flaw size. The staff
reviewed the analysis assumptions and concludes that the flaw size and
distribution are conservatively modeled in accordance with the ASME
B&PV Code Section XI flaw evaluation methodology to demonstrate
sufficient structural performance margins in the welds.
In Structural Integrity Associates (SIA) Calculation Package No.
1301415.301, Revision 0, ``Development of an Analysis Based Stress
Allowable Reduction Factor (SARF), Dry Shielded Canister (DSC) Top
Closure Weldments,'' the applicant used a finite element analysis (FEA)
approach to perform generic evaluation of flaw effects on the weld
stress performance. Three types of flaw geometry, radial,
circumferential, and laminar flaws for a range of distribution of flaw
length, depth, and spacing in the DSC ITCP and OTCP were analyzed.
Following a commonly acceptable FEA practice to simulate flaws with the
elements of near zero stiffness, the applicant computed the membrane
and membrane-plus-bending stress intensities in the welds. By comparing
the results from the FEA models, with and without flaws, for the
pressure and side drop load cases, a ratio, or SARF, was determined for
each critical weld section cut of interest. For the OTCP, the applicant
computed SARFs for 7 flaw configurations each for the individual
pressure and side drop loading cases. This established a minimum SARF
of greater than 0.7 for the through-wall circumferential flaws assumed
to span an arc length of 2.016 inches with a common arc spacing of
5.184 inches. From the weld quality review documented in the SIA
report, No. 1301415.405, ``Expectations for Field Closure Welds on the
AREVA-TN NUHOMS[supreg] 61BTH Type 1 & 2 Transportable Canister for BWR
Dry Fuel Storage,'' the applicant determined that only the
circumferential flaws are potentially representative of the weld
condition of the ITCP. This provided the basis for postulating a 360
degree, 50 percent intermittently embedded, through-wall
circumferential flaw with a 0.006 in\2\ cross section area for the FEA.
This resulted in the calculated SARFs of 0.945 and 0.931 for the
pressure and side drop cases, respectively. The staff reviewed the
modeling assumptions and FEA results and concludes that the FEA method
is suitable for analyzing the stress performance of the weld as a
continuum with multiple embedded flaws.
Using the PAUT flaw indication examination results, the applicant
performed an FEA to determine the weld structural performance margins,
in accordance with the ASME Section III code limits, for the ITCP and
OTCP of DSC 16. As noted in AREVA Calculation No. 11042-0205, Revision
3, ``61BHT ITCP and OTCP Closure Weld Evaluation,'' two full-
circumferential, bounding flaw sets for the OTCP and one for the ITCP
were used in the simulation of the flaw indications in the FEA models.
The first set of the two bounding flaws in the OTCP are 0.14 inches and
0.195 inches each in height while the second set of the three flaws
range in height from 0.07 inches to 0.16 inches. The single flaw set
for the ITCP consists of two bounding flaws, a 0.09-inch high flaw
between the weld metal and the DSC shell and another 0.11-inch high
inside the ITCP, but at close proximity to the weld metal.
Using an elastic-perfectly plastic material property model, the
applicant evaluated the top cover plates-to-shell welds for three
governing load cases: (1) Internal pressure loading of 32 psi for
Service Levels A/B; (2) internal pressure loading of 65 psi for Service
Level D; and (3) side drop loading of 75 g for Service Level D. Given
that the potential exists for the weld to undergo material yielding,
the applicant performed a limit analysis, per the ASME B&PV Code,
Section III, Paragraph NB-3228.1, ``Limit Analysis,'' provisions, for
the Service Level A/B, normal and off-normal condition load cases.
Correspondingly, the rules of ASME B&PV Code Section III, Appendix F,
Paragraph F-1341.3, ``Collapse Load,'' were used for the Service Level
D, accident condition load cases. The limit analysis, with elastic-
perfectly plastic material model, revealed that the weld would undergo
unbounded deformation after the material yielding strength is exceeded.
To address the potential material rupture associated with large
weld deformation and, hence, high plastic strain concentrations, the
applicant performed an elastic-plastic analysis to supplement the
determination of the weld performance margins for DSC 16. This was
accomplished by considering a Ramberg-Osgood idealization of the
stress-strain curve for SA-240 Type 301 stainless steel, which
recognizes strain hardening effects for the large-deformation FEA
models with embedded flaws in the welds. The elastic-plastic analyses
resulted in the maximum equivalent plastic strains of 5.97 percent and
6.09 percent for the Service Level D design pressure of 65 psi and side
drop of 75 g, respectively. The calculated strains are much smaller
than the ASME B&PV Code specified minimum elongations of SA-240 Type
304 stainless steel at 40 percent and E308-XX electrode at 35 percent.
Additionally, for a conservative determination of margins of
safety, the applicant considered a load factor of 1.5 to evaluate the
welds subject to a DSC internal pressure of 100 psi (65 x 1.5 = 97.5
<100 psi) and a side drop of 122.5 g (75 x 1.5 = 122.5 g). The elastic-
plastic
[[Page 39074]]
analyses, per the ASME B&PV Code, Section III, Paragraph NB-3228.3
Plastic Analysis provisions, resulted in a peak equivalent plastic
strain of 12.6 percent for both loading cases. On the basis of the weld
material elongation limit of 28 percent, a reduction of the ASME B&PV
Code specified weld elongation limit of 35 percent by a factor 0.8
(0.35 x 0.8 = 0.28), to account for flaws that may not have been
detected by the PAUT examination, the applicant calculated the margins
of safety of 3.69 and 3.60 for the internal pressure and side drop
loading cases, respectively.
The NRC staff reviewed the FEA modeling assumptions and concludes
that the elastic-plastic analysis was implemented with appropriate
loading conditions and materials properties, as described above. The
analysis results show that the welds would undergo plastic deformation
for the Service Level D loading associated with canister internal
pressure and side drop accident conditions. However, no material
rupture or breach of DSC confinement boundary at the welds is expected
because of the large margins of safety against the ASME B&PV Code
specified elongation limits. For this reason, the staff has reasonable
assurance to conclude that the ITCP and OTCP welds of DSC 16 have
adequate structural integrity for the normal, off-normal, and accident
and natural phenomenon conditions. The NRC staff also finds that the
retrievability of DSC 16 is ensured based on the demonstration of
adequate structural integrity discussed above.
The NRC staff finds that the structural function of DSC 16, loaded
under CoC No. 1004, Amendment No. 10, addressed in the exemption
request remains in compliance with 10 CFR part 72.
Thermal Review for the Requested Exemption: The applicant stated
that even though nonconforming examinations exist, satisfactory
completion of the required helium leak test conducted on DSC 16 has
specifically demonstrated the integrity of the primary confinement
boundary (ITCP and siphon/vent cover plate) welds. These tests
(conducted per TS 1.2.4a) specifically demonstrate that the primary
confinement barrier field welds are ``leak tight'' as defined in
American National Standards Institute (ANSI) N14.5-1997. The licensee
stated that, in this respect, the helium leak test demonstrates the
basic integrity of the confinement barrier and the lack of a through-
weld flaw in the field closure welds that would lead to a loss of
cavity helium in DSC 16. The licensee stated that the field closure
welds indirectly support the thermal design function by virtue of their
confinement function (as demonstrated by the helium leak test conducted
on DSC 16) which assures the helium atmosphere in the DSC 16 cavity is
maintained in order to support heat transfer.
The NRC staff reviewed the licensee's exemption request and also
evaluated its effect on the DSC 16 thermal performance. The NRC staff
concludes that the cask thermal performance is not affected by the
exemption request because the applicant has shown that a satisfactory
helium leak test was conducted on DSC 16, which assures integrity of
the primary confinement boundary. Integrity of the primary confinement
boundary assures the spent fuel is stored in a safe inert environment
with unaffected heat transfer characteristics that assure peak cladding
temperatures remain below allowable limits. Therefore, based on the NRC
staff's review of the licensee's evaluation and technical
justification, the NRC staff finds the exemption request acceptable by
virtue of the demonstrable structural integrity of the ITCP and OTCP.
The NRC staff finds that the thermal function of DSC 16, loaded
under CoC No. 1004, Amendment No. 10, addressed in the exemption
request remains in compliance with 10 CFR part 72.
Shielding and Criticality Safety Review for the Requested
Exemption: The NRC staff reviewed the criticality safety and radiation
protection effectiveness of DSC 16 presented in the Monticello
exemption request. The NRC staff finds that DSC 16 is not affected by
the nonconforming PT examinations because storage of DSC 16 on the MNGP
ISFSI will not significantly alter the assumptions of the criticality
safety and radiation protection analysis of the 61BTH DSC. The interior
of DSC 16 will continue to prevent water in-leakage, which means that
the system will remain subcritical under all conditions. The
nonconforming PT examinations do not affect the radiation source term
of the spent fuel contents, or the configuration of the shielding
components of the Standardized NUHOMS[supreg] system containing the
61BTH DSC, meaning that the radiation protection performance of the
system is not altered.
The NRC staff finds that the criticality safety and shielding
function of DSC 16, loaded under CoC No. 1004, Amendment No. 10,
addressed in the exemption request remains in compliance with 10 CFR
part 72.
Confinement Review for the Requested Exemption: The objective of
the confinement evaluation was to confirm that DSC 16 loaded at the
MNGP met the confinement-related requirements described in 10 CFR part
72.
As described in the licensee's ``Exemption Request for
Nonconforming Dry Shielded Canister Dye Penetrant Examinations''
(Enclosure 1 of the September 29, 2015, submittal), certain elements of
the DSC 16 closure weld PT examinations did not comply with examination
procedures. To support the exemption request, the licensee noted that a
helium leakage rate test of the closure's confinement boundary,
including ITCP weld, siphon cover plate weld, and vent port cover plate
weld, were conducted per TS 1.2.4a and demonstrated that the primary
confinement barrier field welds met the TS acceptance criterion of 1E-7
cc/sec (i.e., ``leaktight'' as defined by ANSI N14.5). The applicant
noted that failure to comply with the PT examination procedures would
not change the general integrity of these DSC closure welds. NRC staff
concludes that not performing the PT examination procedures relevant to
this exemption request would not change the results of the helium
leakage test and, therefore, the demonstration of the closure
confinement integrity, as defined by the licensing basis, is
unaffected. In addition, in the Structural Review for the Requested
Exemption and Materials Review for the Requested Exemption evaluations
described previously, staff evaluated the applicant's repair and
verification activities and the PAUT examinations and analyses
associated with DSC 16 and concluded DSC 16 meets the requirements of
10 CFR part 72.
As discussed above, because the PT examinations did not affect DSC
16's helium leak test results, the NRC staff finds that the confinement
function of DSC 16, loaded under CoC No. 1004, Amendment No. 10,
remains in compliance with 10 CFR part 72.
Review of Common Defense and Security: The NRC staff considered the
potential impacts of granting the exemption on the common defense and
security. The requested exemption is not related to any security or
common defense aspect of the MNGP ISFSI, therefore granting the
exemption would not result in any potential impacts to common defense
and security.
Based on its review, the NRC staff has reasonable assurance that
the storage system will continue meet the thermal, structural,
criticality, retrievability and radiation protection requirements of 10
CFR part 72 and, therefore, will not endanger life or property. The NRC
staff
[[Page 39075]]
also finds that there is no threat to the common defense and security.
Therefore, the NRC staff concludes that the exemption to relieve
the applicant from meeting TS 1.2.5 of Attachment A of CoC No. 1004,
Amendment No. 10, which requires that liquid penetrant test
examinations be performed on DSCs to verify the acceptability of the
closure welds, allowing for transfer DSC 16 into an HSM, and would
permit the continued storage of that DSC for the service life of the
canister at the MNGP ISFSI will not endanger life or property or the
common defense and security.
Otherwise in the Public Interest
In considering whether granting the exemption is in the public
interest, the NRC staff considered the alternative of not granting the
exemption. If the exemption were not granted, in order to comply with
the CoC, either (1) DSC 16 would have to be opened and unloaded, and
the contents loaded in a new DSC, and that DSC welded and tested, or
(2) the OTCP would need to be machined off, and the ITCP weld machined
down to the root weld; and the DSC, ITCP and OTCP inspected to
determine if there was any damage as a result of the machining (which
would then necessitate the actions detailed in option 1). If there were
no such damage, the DSC would need to be re-welded and inspected. Both
options would entail a higher risk of a cask handling accidents,
additional personnel exposure, and greater cost to the applicant. Both
options would also generate additional radioactive contaminated
material (including the unloaded DSC for option 1) and waste from
operations, because the lid would have to be removed in either case,
which would generate cuttings from removing the weld material that
could require disposal as contaminated material.
The proposed exemption to allow transfer of DSC 16 into an HSM, and
permit the continued storage of that DSC for the service life of the
canister at the MNGP ISFSI, is consistent with NRC's mission to protect
public health and safety. Approving the requested exemption produces
less of an opportunity for a release of radioactive material than the
alternatives to the proposed action because there will be no operations
involving opening the DSCs which confine the spent nuclear fuel.
Therefore, the exemption is in the public interest.
Environmental Consideration
The NRC staff also considered in the review of this exemption
request whether there would be any significant environmental impacts
associated with the exemption. The NRC staff determined that this
proposed action fits a category of actions that do not require an
environmental assessment or environmental impact statement.
Specifically, the exemption meets the categorical exclusion in 10 CFR
51.22(c)(25).
Granting this exemption from 10 CFR 72.212(a)(2), 72.212(b)(3),
72.212(b)(5)(i), 72.214, and 72.212(b)(11) only relieves the applicant
from the inspection or surveillance requirements associated with
performing PT examinations with regard to meeting Technical
Specification (TS) 1.2.5 of Attachment A of CoC No. 1004. A categorical
exclusion for inspection or surveillance requirements is provided under
10 CFR 51.22(c)(25)(vi)(C) if the criteria in 10 CFR 51.22(c)(25)(i)-
(v) are also satisfied. In its review of the exemption request, the NRC
staff determined, as discussed above, that, under 10 CFR 51.22(c)(25):
(i) Granting the exemption does not involve a significant hazards
considerations because granting the exemption neither reduces a margin
of safety, creates a new or different kind of accident from any
accident previously evaluated, nor significantly increases either the
probability or consequences of an accident previously evaluated; (ii)
granting the exemption would not produce a significant change in either
the types or amounts of any effluents that may be released offsite
because the requested exemption neither changes the effluents nor
produces additional avenues of effluent release; (iii) granting the
exemption would not result in a significant increase in either
occupational radiation exposure or public radiation exposure, because
the requested exemption neither introduces new radiological hazards nor
increases existing radiological hazards; (iv) granting the exemption
would not result in a significant construction impact, because there
are no construction activities associated with the requested exemption;
and; (v) granting the exemption would not increase either the potential
or consequences from radiological accidents such as a gross leak from
the closure welds, because the exemption neither reduces the ability of
the closure welds to confine radioactive material nor creates new
accident precursors at the MNGP ISFSI. Accordingly, this exemption
meets the criteria for a categorical exclusion in 10 CFR
51.22(c)(25)(vi)(C).
IV. Availability of Documents
The documents identified in the following table are available to
interested persons through one or more of the following methods, as
indicated.
------------------------------------------------------------------------
Document ADAMS Accession No.
------------------------------------------------------------------------
Monticello Nuclear Generating Plant ML15275A023
Exemption Request for Nonconforming ML15275A024
Dry Shielded Canister Dye Penetrant ML15275A025
Examinations, September 29, 2015.
Monticello Nuclear Generating Plant ML16035A214
Exemption Request for Nonconforming ML16049A081
Dry Shielded Canister Dye Penetrant ML16049A094
Examinations, Supplemental
Information, January 29, 2016.
Monticello Nuclear Generating Plant ML16091A228
Exemption Request for Nonconforming ML16097A460
Dry Shielded Canister Dye Penetrant
Examinations, Supplemental Information
to Respond to the Second Request for
Additional Information, March 29, 2016.
Interim Staff Guidance No. 15, Rev. 0, ML010100170
Materials Evaluation, January 10, 2001.
Technical Justification for Phased ML16035A185
Array Ultrasonic Examination of Dry ML16035A186
Storage Canister Lid Welds Report No. ML16049A094
54-PQ-114-001, January 30, 2015.
Technical Report of the Demonstration ML16035A184
of UT NDE Procedure 54-UT-114-000
Phased Array Ultrasonic Examination of
Dry Storage Canister Lid Welds Report
No. 51-9234641-001, January 30, 2015.
61BTH ITCP and OTCP closure Weld Flaw ML16097A460
Evaluation, Calculation 11042-0205,
Revision 3, March 21, 2016.
Technical Letter Report, An Evaluation ML093570315
of Ultrasonic Phased Array Testing for
Reactor Piping System Components
Containing Dissimilar Metal Welds JCN
N6398, Task 2A, PNNL-19018,''
Richland, WA; Pacific Northwest
National Laboratory, November 2009.
[[Page 39076]]
AREVA Calculation No. 11042-0204, ML15275A024
Revision 3, Allowable Flaw Size
Evaluation in the Inner Top Cover Weld
for DSC #16, September 29, 2015.
Structural Integrity Associates ML15275A025
Calculation Package No. 1301415.301,
Revision 0, Development of an Analysis
Based Stress Allowable Reduction
Factor (SARF), Dry Shielded Canister
(DSC) Top Closure Weldments, October
2014.
Structural Integrity Associates report, ML14309A194
No. 1301415.405, Expectations for
Field Closure Welds on the AREVA-TN
NUHOMS[supreg] 61BTH Type 1 & 2
Transportable Canister for BWR Dry
Fuel Storage, November 3, 2014.
------------------------------------------------------------------------
IV. Conclusion
Based on the foregoing considerations, the NRC staff has determined
that, pursuant to 10 CFR 72.7, the exemption is authorized by law, will
not endanger life or property or the common defense and security, and
is otherwise in the public interest. Therefore, the NRC grants the
applicant an exemption from the requirements of 10 CFR 72.212(a)(2),
72.212(b)(3), 72.212(b)(5)(i), 72.214, and 72.212(b)(11), only with
regard to meeting Technical Specification (TS) 1.2.5 of Attachment A of
CoC No. 1004 for DSC 16.
This exemption is effective upon issuance.
Dated at Rockville, Maryland, this 8th day June, 2016.
For the Nuclear Regulatory Commission.
Bernie White,
Acting Branch Chief, Spent Fuel Licensing Branch, Division of Spent
Fuel Management, Office of Nuclear Material Safety and Safeguards.