Reconsideration of Certain Startup/Shutdown Issues: National Emission Standards for Hazardous Air Pollutants From Coal- and Oil-Fired Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial-Commercial-Institutional, and Small Industrial-Commercial-Institutional Steam Generating Units, 68777-68795 [2014-27125]
Download as PDF
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
at the bridge as soon as possible, but not
more than one hour after malfunction or
disability of the remote system.
*
*
*
*
*
Dated: October 30, 2014.
Stephen P. Metruck,
Rear Admiral, United States Coast Guard,
Commander, Fifth Coast Guard District.
[FR Doc. 2014–27296 Filed 11–18–14; 8:45 am]
BILLING CODE 9110–04–P
ENVIRONMENTAL PROTECTION
AGENCY
40 CFR Parts 60 and 63
[EPA–HQ–OAR–2009–0234; EPA–HQ–OAR–
2011–0044; FRL–9919–29–OAR]
RIN 2060–AS07
Reconsideration of Certain Startup/
Shutdown Issues: National Emission
Standards for Hazardous Air Pollutants
From Coal- and Oil-Fired Electric Utility
Steam Generating Units and Standards
of Performance for Fossil-Fuel-Fired
Electric Utility, Industrial-CommercialInstitutional, and Small IndustrialCommercial-Institutional Steam
Generating Units
Environmental Protection
Agency.
ACTION: Final rule; notice of final action
on reconsideration.
AGENCY:
The Environmental Protection
Agency (EPA) is taking final action on
its reconsideration of the startup and
shutdown provisions in the final rules
titled, ‘‘National Emission Standards for
Hazardous Air Pollutants from Coaland Oil-fired Electric Utility Steam
Generating Units and Standards of
Performance for Fossil-Fuel-Fired
Electric Utility, Industrial-CommercialInstitutional, and Small IndustrialCommercial-Institutional Steam
Generating Units.’’ The national
emission standards for hazardous air
pollutants (NESHAP) issued pursuant to
Clean Air Act (CAA) section 112 are
referred to as the Mercury and Air
Toxics Standards (MATS), and the new
source performance standards (NSPS)
issued pursuant to CAA section 111 are
referred to as the Utility NSPS.
On November 30, 2012, the U.S.
Environmental Protection Agency (EPA)
granted reconsideration of, proposed,
rljohnson on DSK3VPTVN1PROD with RULES
SUMMARY:
and requested comment on a limited set
of issues in the February 16, 2012, final
MATS and Utility NSPS, including
certain issues related to the final work
practice standards applicable during
startup periods and shutdown periods.
On June 25, 2013, the EPA reopened the
public comment period for the
reconsideration issues related to the
startup and shutdown provisions of
MATS and the startup and shutdown
provisions related to the particulate
matter (PM) standard in the Utility
NSPS. The EPA is now taking final
action on the standards applicable
during startup periods and shutdown
periods in MATS and on startup and
shutdown provisions related to the PM
standard in the Utility NSPS.
DATES: The effective date of the rule is
November 19, 2014.
ADDRESSES: Docket. The EPA
established two dockets for this action:
Docket ID No. EPA–HQ–OAR–2011–
0044 (NSPS action) and Docket ID No.
EPA–HQ–OAR–2009–0234 (MATS
NESHAP action). All documents in the
dockets are listed in the https://
www.regulations.gov index. Although
listed in the index, some information is
not publicly available (e.g., confidential
business information (CBI) or other
information whose disclosure is
restricted by statute). Certain other
material, such as copyrighted material,
will be publicly available only in hard
copy form. Publicly available docket
materials are available either
electronically in https://
www.regulations.gov or in hard copy at
the EPA Docket Center, Room 3334,
1301 Constitution Avenue NW.,
Washington, DC. The Public Reading
Room is open from 8:30 a.m. to 4:30
p.m., Monday through Friday, excluding
legal holidays. The telephone number
for the Public Reading Room is (202)
566–1744, and the telephone number for
the Air Docket is (202) 566–1742.
FOR FURTHER INFORMATION CONTACT: For
the MATS NESHAP action: Mr. William
Maxwell, Energy Strategies Group,
Sector Policies and Programs Division
(D243–01), Office of Air Quality
Planning and Standards, U.S.
Environmental Protection Agency,
Research Triangle Park, North Carolina
27711; Telephone number: (919) 541–
5430; Fax number (919) 541–5450;
Email address: maxwell.bill@epa.gov.
For the NSPS action: Mr. Christian
NAICS Code 1
Category
Industry .....................................................
Federal government ..................................
2 221122
State/local/tribal government ....................
2 221122
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
221112
PO 00000
68777
Fellner, Energy Strategies Group, Sector
Policies and Programs Division (D243–
01), Office of Air Quality Planning and
Standards, U.S. Environmental
Protection Agency, Research Triangle
Park, North Carolina 27711; Telephone
number: (919) 541–4003; Fax number
(919) 541–5450; Email address:
fellner.christian@epa.gov.
SUPPLEMENTARY INFORMATION:
Outline. The information presented in
this preamble is organized as follows:
I. General Information
A. Does this action apply to me?
B. How do I obtain a copy of this
document?
C. Judicial Review
II. Background
III. Summary of This Action
IV. Summary of Final Action and Changes
Since Proposal—MATS Startup/
Shutdown Issues
V. Summary of Final Action and Changes
Since Proposal—Utility NSPS
VI. Impacts of This Final Rule
A. Summary of Emissions Impacts, Costs
and Benefits
B. What are the air impacts?
C. What are the energy impacts?
D. What are the compliance costs?
E. What are the economic and employment
impacts?
F. What are the benefits of the final
standards?
VII. Statutory and Executive Order Reviews
A. Executive Order 12866: Regulatory
Planning and Review and Executive
Order 13563: Improving Regulation and
Regulatory Review
B. Paperwork Reduction Act
C. Regulatory Flexibility Act
D. Unfunded Mandates Reform Act
E. Executive Order 13132: Federalism
F. Executive Order 13175: Consultation
and Coordination With Indian Tribal
Governments
G. Executive Order 13045: Protection of
Children From Environmental Health
Risks and Safety Risks
H. Executive Order 13211: Actions That
Significantly Affect Energy Supply,
Distribution, or Use
I. National Technology Transfer and
Advancement Act
J. Executive Order 12898: Federal Actions
To Address Environmental Justice in
Minority Populations and Low-Income
Populations
K. Congressional Review Act
I. General Information
A. Does this action apply to me?
Categories and entities potentially
affected by this action include:
Examples of potentially regulated entities
Fossil fuel-fired electric utility steam generating units.
Fossil fuel-fired electric utility steam generating units owned by the federal government.
Fossil fuel-fired electric utility steam generating units owned by municipalities.
Frm 00015
Fmt 4700
Sfmt 4700
E:\FR\FM\19NOR1.SGM
19NOR1
68778
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
NAICS Code 1
Category
921150
1 North
Examples of potentially regulated entities
Fossil fuel-fired electric utility steam generating units in Indian country.
American Industry Classification System.
state, or local government-owned and operated establishments are classified according to the activity in which they are engaged.
2 Federal,
This table is not intended to be
exhaustive, but rather to provide a guide
for readers regarding entities likely to be
affected by this action. To determine
whether your facility, company,
business, organization, etc., would be
regulated by this action, you should
examine the applicability criteria in 40
CFR 60.40, 60.40Da, or 60.40c or in 40
CFR 63.9982. If you have any questions
regarding the applicability of this action
to a particular entity, consult either the
air permitting authority for the entity or
your EPA regional representative as
listed in 40 CFR 60.4 or 40 CFR 63.13
(General Provisions).
B. How do I obtain a copy of this
document?
In addition to being available in the
docket, an electronic copy of this final
rule will be available on the World
Wide Web (WWW) through the
Technology Transfer Network (TTN).
Following signature, a copy of the
action will be posted on the TTN’s
policy and guidance page for newly
proposed or promulgated rules at the
following address: https://www.epa.gov/
ttn/oarpg/. The TTN provides
information and technology exchange in
various areas of air pollution control. A
copy of this action will also be available
on: www.epa.gov/mats/.
rljohnson on DSK3VPTVN1PROD with RULES
C. Judicial Review
Under CAA section 307(b)(1), judicial
review of this final rule is available only
by filing a petition for review in the U.S.
Court of Appeals for the District of
Columbia Circuit by January 20, 2015.
Under CAA section 307(d)(7)(B), only
an objection to this final rule that was
raised with reasonable specificity
during the period for public comment
can be raised during judicial review.
Note, under CAA section 307(b)(2), the
requirements established by this final
rule may not be challenged separately in
any civil or criminal proceedings
brought by the EPA to enforce these
requirements.
II. Background
On February 16, 2012, the final MATS
and the Utility NSPS rules were
published in the Federal Register. 77 FR
9304. Following promulgation of the
final rules, the Administrator received
petitions for reconsideration of various
provisions of both MATS and the Utility
NSPS pursuant to CAA section
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
307(d)(7)(B), including requests to
reconsider the work practice standards
applicable during startup periods and
shutdown periods that were included in
the final rule. Copies of the MATS
petitions are provided in Docket ID No.
EPA–HQ–OAR–2009–0234. Copies of
the Utility NSPS petitions are provided
in Docket ID No. EPA–HQ–OAR–2011–
0044. The EPA granted reconsideration
of the startup and shutdown provisions
because the agency proposed to require
sources to comply with the numeric
standards at all times and did not
propose a work practice standard for
startup periods and shutdown periods;
thus, the public was not provided an
opportunity to comment on the work
practice requirements contained in the
final rule.1 On November 30, 2012, the
EPA published a proposed rule
reconsidering certain new source
standards issued in MATS and the
startup and shutdown provisions in
MATS and the Utility NSPS, among
other things. 77 FR 71323. The EPA
proposed certain minor changes to the
startup and shutdown provisions
contained in the 2012 final rule based
on information obtained in the petitions
for reconsideration. On April 24, 2013
(78 FR 24073), the EPA took final action
on the new source standards that were
reconsidered and also the technical
corrections contained in the November
30, 2012, proposed action. The EPA did
not take final action on the startup and
shutdown provisions, and, on June 25,
2013, the EPA added new information
and analysis to the docket and reopened
the public comment period for the
proposed revisions to the startup and
shutdown provisions in MATS and the
1 The EPA continues to believe that the final
existing source standards contain sufficient
variability to include startup periods and shutdown
periods. Furthermore, in light of what we have
learned concerning the performance of the best
performing sources during startup and shutdown
(e.g., clean fuel use and efficient engagement of air
pollution control devices (APCDs)), we believe that
the best performing electric utility steam generating
units (EGUs) for startup periods and shutdown
periods will have hazardous air pollutant (HAP)
emissions that are lower than the numeric
standards, when averaged over the startup and
shutdown period as defined. However, as explained
in the record, the lack of HAP data for these periods
and the current technical challenges to accurately
measure HAP emissions during startup and
shutdown cause us to establish a work practice for
such periods.
PO 00000
Frm 00016
Fmt 4700
Sfmt 4700
startup and shutdown provisions related
to the PM standard in the Utility NSPS.
III. Summary of This Action
This final action includes final
amendments to the startup and
shutdown provisions of the final MATS
and Utility NSPS issued by the EPA on
February 16, 2012. This action does not
alter or reopen any other MATS or
Utility NSPS provisions, including
those provisions recently upheld by the
U.S. Court of Appeals for the District of
Columbia Circuit (Court) in White
Stallion Energy Center v. EPA on April
15, 2014. 784 F.3d 1222 (D.C. Cir. 2014).
The February 2012 final rule is and
remains in effect for all sources, and
existing sources must comply with the
final rule by April 16, 2015, or seek an
extension of that compliance date from
the appropriate title V permitting
authority.
The November 30, 2012, proposed
reconsideration rule reopened, among
other things: (1) The requirements
applicable during startup periods and
shutdown periods in MATS, and (2) the
startup and shutdown provisions related
to the PM standard in the Utility NSPS.
We are taking final action today on the
requirements for startup periods and
shutdown periods contained in 40 CFR
Part 63, subpart UUUUU, and 40 CFR
Part 60, subpart Da.
As noted above, in the proposed
reconsideration rule, the EPA proposed
revisions to, and took comment on, the
definitions of ‘‘startup’’ and
‘‘shutdown’’ and the work practice
requirements associated with those
periods in the final MATS rule. The
EPA also took comment on the startup
and shutdown provisions relating to the
PM standard in the Utility NSPS. The
EPA received a number of comments
regarding the proposed startup and
shutdown provisions, including data
and information relevant to the
proposed work practice standard that
applies during such periods, and the
agency also reviewed EGU nitrogen
oxides (NOX) and sulfur dioxide (SO2)
emissions data generated during startup
periods and shutdown periods and
submitted to the EPA pursuant to title
IV of the CAA (i.e. the Acid Rain
Program). On June 25, 2013 (78 FR
38001), the EPA reopened the public
comment period on the startup/
shutdown provision and solicited
comment on both the public comments
E:\FR\FM\19NOR1.SGM
19NOR1
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
provided in response to the November
30, 2012, proposal, as well as the startup
and shutdown technical support
document (TSD) that was based on the
Acid Rain Program data that was made
available in the docket.2 The agency has
reviewed all of the comments received
on the startup and shutdown issues. As
described below, the EPA is taking final
action on the startup and shutdown
provisions in MATS and the Utility
NSPS.
Because this final rule is very similar
to the February 2012 final rule, the
impacts of these revisions on the costs
and the benefits of the final rule are
minor.
rljohnson on DSK3VPTVN1PROD with RULES
IV. Summary of Final Action and
Changes Since Proposal—MATS
Startup/Shutdown Issues
After consideration of the public
comments received and other
information, the EPA is finalizing the
startup and shutdown provisions
contained in the final MATS rule and
we are also finalizing an alternative
compliance option for startup periods
and shutdown periods.3 We address
several significant comments in this
preamble. For a complete summary of
the comments received on the issues we
are finalizing today and our responses
thereto, please refer to the memorandum
‘‘National Emission Standards For
Hazardous Air Pollutants From CoalAnd Oil-Fired Electric Utility Steam
Generating Units—Reconsideration Of
Certain Startup/Shutdown Issues;
Summary Of Public Comments And
Responses’’ (RTC) in Docket ID No.
EPA–HQ–OAR–2009–0234.
As discussed in more detail below,
the alternative work practice standard
for startup periods and shutdown
periods requires coal- and oil-fired
EGUs to initiate startup using only clean
2 The EPA is still reviewing the other issues
raised in the petitions for reconsideration and is not
taking any action at this time with respect to those
issues.
3 This preamble does not discuss the startup and
shutdown provisions provided in the February 2012
final MATS rule. (See 77 FR 9486, 9493–9494.) We
are not altering those provisions in this final action.
However, the critical control requirement (i.e., the
requirement to use clean fuels to start and warm the
EGU and relevant controls prior to coal, residual,
or solid oil-derived fuel combustion, as well as
recordkeeping and reporting procedures for those
requirements) is the same for both. We are
maintaining the final rule approach and will
evaluate the continued need for the alternative
definition during our ongoing 8-year reviews. We
intend to use HAP and HAP surrogate data
collected during periods of startup and periods of
shutdown to evaluate the accuracy of CEMS from
the start of electricity generation to the end of
startup as defined under the alternative included in
this final rule (i.e., 4 hours after electricity
generation). We will use these data to help
determine whether it is appropriate to make
changes to the rule in the future.
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
fuels and to continue combusting the
maximum amount of clean fuels
possible at the facility throughout the
entire startup period. EGUs that chose to
comply with the alternative work
practice will be required to have
sufficient clean fuel capacity to startup
and warm the facility to the point where
the primary PM controls (e.g., fabric
filters (FFs) and electrostatic
precipitators (ESPs)) can be brought on
line at the same time as, or within 1
hour of, the addition of the primary fuel
(i.e., coal, residual oil, or solid oilderived fuel) to the EGU. If a facility
does not have sufficient clean fuel
capacity to enable initiation and
operation of the PM controls within 1
hour of addition of primary fuel, then
the source will have to increase its clean
fuel capacity or take other action to
comply with the work practice
requirements in this final rule.4 The
alternate included in this final rule also
requires EGUs to comply with the
applicable numeric standards within 4
hours of the generation of electricity or
thermal energy for use either on site or
for sale over the grid (i.e., the end of
startup) and to continue to maximize
clean fuel use throughout that period.
The EPA has established these final
alternative requirements after
determining what the best performing
EGUs do during startup periods and
shutdown periods. The EPA used
several different metrics to determine
the best performing sources for various
aspects of the work practice
requirements and definitions.
Specifically, concerning the use of clean
fuels, the comments received and the
Acid Rain data in the record indicate
that most EGU operations start using
clean fuels and that many of those EGUs
generate electricity while using clean
fuels and/or routinely engage their PM
controls before or within 1 hour of
beginning to combust coal, residual oil,
or solid oil-derived fuel. The clean fuels
identified by the commenters and
4 We note that the startup and shutdown
provisions contained in the February 16, 2012, final
MATS rule also required EGUs to maximize clean
fuels during startup periods and shutdown periods,
as sources are required to comply with all MATS
and NSPS standards at the time of electricity
generation. Therefore, EGUs complying with the
work practice as finalized on February 16, 2012,
will necessarily be required to warm their units on
clean fuels alone for extended periods unless the
operators determine that compliance over the 30day averaging period can be achieved without
certain HAP controls for a portion of time after the
defined startup period. EGU operators may
conclude compliance without controls for a short
period after startup is possible for a number of
reasons, including the variability included in the
numeric standards and our understanding from
regulating many HAP categories that sources
generally over-control to ensure a compliance
margin is maintained.
PO 00000
Frm 00017
Fmt 4700
Sfmt 4700
68779
included in the final rule are inherently
cleaner from a HAP emissions
perspective than coal, residual oil, or
solid oil-derived fuel, and, for this
reason, maximizing the use of clean
fuels during startup will greatly limit
the emissions of HAP while EGUs are
warming up to temperatures sufficient
to engage the air pollution control
devices (APCDs). Thus, we considered
those EGUs that use clean fuels for the
longest period of time before the
introduction of coal and the generation
of electricity to be the best performing
EGUs because they are likely to have the
lowest amount of HAP emissions during
the startup period. In addition, the best
performing EGUs were also determined
to be those with the ability to engage PM
control devices at the time (i.e., within
1 hour) of introduction of primary fuel.
Further, we believe all of the concerns
raised by commenters about the ability
to engage the PM controls can be safely
resolved to allow compliance with the
final work practice, as explained in the
RTC.5 We believe it is appropriate to use
generation of electricity as an indicator
of startup for two reasons. First, the
information we have indicates that the
only reason the owner/operator of an
EGU chooses to fire fuel in a boiler is
to generate electricity. Therefore, any
event that starts with firing of fuel in a
boiler that has been shut down will
culminate in generation of electricity.
Second, introduction of coal to the
boiler is also always associated with
generation of electricity. The TSD and
other information confirm our
understanding.
For determining the appropriate time
after generation to define the end of
startup (i.e., the time when the
numerical standards apply), the EPA
conducted an analysis of continuous
emission monitor system (CEMS) data
for NOX and SO2 from EGUs to
determine the range of times after initial
generation of electricity or thermal
energy that EGUs typically take to
engage and operate all of their APCDs.
The EPA determined the best
performing 12 percent of EGUs by
identifying those EGUs that were able to
engage their APCDs most quickly after
the initial generation of electricity or
thermal energy and averaged that time
to determine the end of the startup
period when the numeric standards
would become applicable. Specifically,
we evaluated the average startup period
for the best performing 12 percent of
EGUs for which the EPA has the
relevant data (i.e., those with the
relevant NOX and/or SO2 controls). We
5 See, e.g., EPA–HQ–OAR–2009–0234–20269,
–20275, and –20303.
E:\FR\FM\19NOR1.SGM
19NOR1
rljohnson on DSK3VPTVN1PROD with RULES
68780
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
used 12 percent of the sources with the
relevant controls because the metric
upon which the end of startup is based
depends on the presence of the relevant
controls, not on the actual NOX and SO2
emissions. Thus, sources without the
relevant controls cannot be compared
against sources with the relevant
controls for purposes of defining the
end of startup in this final rule. CAA
section 112(d)(3)(A) directs the EPA to
establish MACT floor standards based
on the performance on the best
performing 12 percent of sources for
which the Administrator has data, and,
in this case, the agency does not have
relevant data from all sources in the
category. For this reason, it is reasonable
to establish the work practice based on
12 percent of the sources with the
relevant data (i.e., those EGUs with the
relevant NOX or SO2 controls).
We used this approach to determine
the end of startup because it is
reasonable to expect the EGUs that are
able to most quickly and efficiently
engage their controls after the
generation of electricity to be the best
performing sources and to have the
lowest HAP emissions during and
directly after the startup period, and
because we are confident that EGUs will
be able to accurately measure HAP
emissions with CEMS at this time. The
requirement to maximize the use of
clean fuels (with inherently low HAP
emissions) during the startup period
ensures that HAP emissions are
minimized during that time. Because
EGUs subject to Acid Rain Program
requirements are required to submit
continuous NOX and SO2 data to the
EPA, the agency believes it has data on
all startup events from those EGUs
subject to that program, which comprise
nearly all EGUs subject to this rule, for
over a decade. Thus, we believe we have
a full data set from which to determine
the end of the startup period for the best
performing 12 percent of sources for
which we have the relevant data.6 We
maintain it is reasonable to use the CAA
section 112(d)(3) metric for establishing
MACT floors for existing sources as a
starting point for determining the
appropriate work practice when
presented with such comprehensive
data. See CAA 112(h)(1) (directing the
agency to establish a work practice
standard ‘‘which in the Administrator’s
judgment is consistent with the
provisions of subsection (d) or (f) of this
section.’’).
6 We note that these data are not reliable for
quantifying emissions for this analysis but, rather,
the data allow us to evaluate when controls are
turned on for the purpose of determining when
startup ends.
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
For shutdown periods, the EPA
determined that sources could cease
adding coal or oil to the EGU prior to
shutting down the APCDs. We
determined that sources able to run
their control devices even after coal or
oil is added to the EGU for the last time
before shutdown were the best
performing sources because HAP
emissions would be minimized as the
EGU combusts the remaining coal or oil
in the boiler.
The final work practice standard,
when applied across the industry, will
greatly reduce HAP emissions during
startup periods and shutdown periods.
The requirement to maximize clean fuel
use throughout the startup period will
significantly limit HAP emissions
because of the inherently low HAP
emissions associated with the clean
fuels identified in 40 CFR 63.10042.7 In
addition, the requirement to engage and
operate PM controls as expeditiously as
possible and within 1 hour of coal,
residual oil, or solid oil-derived fuel
combustion will limit HAP emissions
that are particulate in nature throughout
the remainder of the startup period. We
believe that application of this work
practice will lead to HAP emissions
during startup periods and shutdown
periods that are comparable to, and
potentially lower than, those levels
authorized during normal operations
when averaged over the entire startup
and/or shutdown period. During the 8year review required under CAA section
112(d)(6), the agency intends to further
assess HAP emissions during startup
and shutdown based on data collected
from sources complying with the final
rule, though we recognize that
prospectively our ability to establish
numerical standards during startup
periods and shutdown periods will
depend, at least in part, on the further
development of testing methodologies
that will allow the agency to accurately
measure emissions during those periods
with an acceptable level of certainty.
The specific provisions of the
alternative startup and shutdown
requirements and our rationales for
those provisions are discussed in more
detail below and in the RTC document
in Docket ID No. EPA–HQ–OAR–2009–
0234.
7 Natural gas is one of the clean fuels identified
in this final rule and the agency determined in 2000
that it was neither appropriate nor necessary to
regulate natural gas-fired EGUs because the impacts
from HAP emissions from such units are
‘‘negligible.’’ See ‘‘Regulatory Finding on the
Emissions of Hazardous Air Pollutants from Electric
Utility Steam Generating Units,’’ 65 FR 79825,
79831 (December 20, 2000).
PO 00000
Frm 00018
Fmt 4700
Sfmt 4700
1. Definitions
In the November 2012 reconsideration
proposal, we proposed revisions to the
definitions of startup and shutdown
contained in the final MATS rule and
set forth in 40 CFR 63.10042, after
receiving petitions for reconsideration
of the startup and shutdown provisions
in the final MATS rule. Petitioners
asserted, among other things, that the
final rule’s definitions of startup and
shutdown were not sufficiently clear,
should accommodate operation of
cogeneration units, and did not
accurately reflect startup conditions for
all affected units. We received
additional comments on these issues
during the public comment periods. For
more discussion of the petitions for
reconsideration and the comments on
the definitions in the final rule, see the
RTC in Docket ID No. EPA–HQ–OAR–
2009–0234.
As a result of comments received on
the November 2012 proposal and the
June 2013 reopening of the public
comment period, we have further
revised the proposed definitions as
follows.
a. Startup. The definition of startup in
the November 2012 reconsideration
proposed rule was similar to the
definition the EPA finalized in MATS in
February 2012. In this final
reconsideration rule, we have
maintained the final MATS definition of
startup and, in addition, are finalizing
an alternative definition of startup based
on the November 2012 proposal and the
analysis in the startup and shutdown
TSD. Sources may choose to use either
definition of startup when complying
with the startup and shutdown
requirements. We are finalizing both
definitions because we believe that they
both meet the requirements of CAA
section 112 to reduce HAP emissions
during this time period and will provide
operators with flexibility, even though
we question the ability to accurately
measure HAP emissions at the start of
electricity generation. A discussion of
the comments and analyses that led to
inclusion of the alternative startup
definition is provided below.
In the November 2012 reconsideration
proposal, the EPA proposed that startup
be defined as the period in which
operation of an EGU is initiated for any
purpose. The proposed definition
indicated that startup begins with either
the first-ever firing of fuel in an EGU for
the purpose of producing electricity or
useful thermal energy (such as heat or
steam) for industrial, commercial,
heating, or cooling purposes or the
firing of fuel in an EGU for any purpose
after a shutdown event. The proposed
E:\FR\FM\19NOR1.SGM
19NOR1
rljohnson on DSK3VPTVN1PROD with RULES
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
definition indicated that startup ended
when the EGU generates electricity that
is sold or used for any other purpose
(including on site use), or the EGU
makes useful thermal energy (such as
heat or steam) for industrial,
commercial, heating, or cooling
purposes, whichever is earlier. The
agency received comments stating that
the general approach provided in the
proposed definition of ‘‘startup’’
(particularly the end of startup) was
directionally correct but did not allow
sufficient time for the APCDs to become
effective and, thus, the industry was
concerned that some EGUs would not be
able to achieve the MATS emission
limits finalized in the February 2012
rule at the end of startup as defined in
the final MATS rule. The comments
further stated the opinion that startup
did not end with first generation of
electricity or production of steam as the
EPA had proposed. Instead, some
comments suggested that the defined
end of startup should be changed to be
4 hours after 25-percent load is first
reached or 12 hours after first electricity
generation, whichever occurs first.
Some comments stated that even longer
time periods were necessary for certain
types of EGUs, that different startup
periods should be defined for different
types of EGUs, and that additional
consideration should be given to a
wider variety of APCDs. Other
comments maintained that the
definition in the final MATS rule was
appropriate and indicated that any
extension of time during which the
EGUs were not subject to the final rule’s
emission limits was not in accordance
with CAA section 112.
The EPA disagrees with the
commenters to the extent they maintain
that a work practice is required after
emissions can be accurately measured
or that the agency is bound to the time
contained in the final rule where, as
here, we conclude that the HAP
measurement methodologies are not
capable of accurately measuring HAP
emissions during the defined startup
period. The EPA did, however, conduct
an additional technical analysis after its
initial review of the comments and in
June 2013 published a document
reopening the public comment period.
The document specifically requested
comment on the additional technical
analysis the EPA had conducted in
response to comments received
concerning the end of startup. See
‘‘Assessment of startup period at coalfired electric generating units’’ (Docket
ID No. EPA–HQ–OAR–2009–0234–
20378). In the analysis, the EPA
examined several indicators that
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
allowed the agency to assess the time
required to engage APCDs at affected
EGUs. Using these indicators, we found
no significant difference in performance
related to startup between the different
groups or types of EGUs assessed in the
analysis (e.g., circulating fluidized bed
(CFB), stoker, subcritical, supercritical).
We further indicated that the results of
our analysis supported defining the end
of startup at coal- and oil-fired EGUs as
occurring at the time to achieve 25
percent of the EGU’s nameplate
generating capacity (megawatts, MW)
plus 3 hours, or the start of electricity
generation plus 6 hours, whichever
comes first.
The EPA has reviewed all of the
comments received on the proposed
definition of startup in response to these
two opportunities for public comment
and has revised the June 2013 analysis.
Based on this review, we are finalizing
a revised definition of ‘‘startup’’ that
uses the approach outlined in the June
2013 assessment with revisions as
discussed below.
Defining the End of ‘‘Startup’’
The June 2013 analysis suggested a
potential end time for startup of 6 hours
after the start of electricity generation or
3 hours after a coal- or oil-fired EGU
reaches 25 percent of nameplate
capacity, whichever occurs first. In
other words, 6 hours after the start of
generation or 3 hours after reaching
electricity generation equal to 25
percent of nameplate capacity,
whichever comes first, an EGU would
have to start monitoring and reporting
its emissions for the purpose of
complying with the numeric emissions
standards contained in MATS.
The EPA took this approach because
we determined that flue gas conditions
will be adequate to accurately measure
HAP emissions with CEMS 4 hours after
the generation of electricity. The
approach evaluated the time for all
APCDs to be functioning because we
determined that stack conditions will be
stable at this point. The analysis was
based on our review of hourly SO2 and
NOX emissions from CEMS installations
from nearly 9,500 distinct startup events
at more than 400 coal-fired EGUs,
including CFB boilers, and subcritical
and supercritical pulverized coal boilers
equipped with SO2 APCDs (e.g., wet or
dry flue gas desulfurization (FGD)) and/
or NOX APCDs (e.g., selective catalytic
reduction (SCR)). The EPA analyzed
hourly SO2 and NOX emissions
primarily because changes in SO2 and
NOX emissions are reasonable indicators
of when APCDs are operational and
stack conditions will be sufficiently
stable to allow for accurate
PO 00000
Frm 00019
Fmt 4700
Sfmt 4700
68781
measurement of HAP emissions with
CEMS. We also note that SO2 emissions
are a surrogate for acid gases (e.g.,
hydrogen chloride); SO2 APCDs can be
used for co-benefit mercury (Hg)
control; and NOX SCR APCDs may
increase the oxidation of Hg,
influencing the effectiveness of Hg
controls.8 The goal of the analysis was
to identify the approximate time it took,
on average, to initiate operation of SO2
and NOX APCDs because it was those
controls (e.g., scrubbers and SCR) that
industry commenters stated required
additional time to engage after the start
of generation of electricity or useful
thermal energy. The goal in conducting
the analysis was not to determine the
time it took for APCDs at all EGUs to
become fully operational, but instead to
determine the average time for the
engagement of APCD to determine a
reasonable end of startup.
The EPA received detailed comments
on the June 2013 analysis and the
proposed rule. Although commenters’
opinions varied, the EPA identified
three distinct groups of comments. The
first group agreed with the EPA’s
approach to define a time limit
following the start of generation, but
many commenters suggested that more
time was necessary to safely and/or
fully engage APCDs. The second group
commented that CAA section 112
requires the EPA to establish standards
based on the average of the best
performing 12 percent of EGUs, not the
average of the fleet. The third group
disagreed with the EPA’s approach,
stating that many APCDs could not be
fully functional within the time limits
specified by the EPA, and citing the
need for greater flexibility.
The EPA evaluated the information
provided by commenters and
considered the different approaches to
define the end of startup.9 After careful
consideration and in light of issues
raised in comments and data provided,
the EPA has revised its initial approach
for determining the end of startup in
8 The EPA did not include hourly PM data in this
analysis because PM CEMS data are not available
and PM CEMS have not yet been certified to
accurately measure during periods of startup and
periods of shutdown as defined in this final rule.
9 It is important to remember that the hour at
which startup ends is the hour at which reporting
for the purpose of determining compliance begins.
Therefore, EGUs must collect and report emissions
and heat input or generation data following the end
of startup. These data are used in calculating
whether an EGU is in compliance with the 30-day
average emission limits. MATS does not mandate
that all APCDs must be fully operational at the end
of startup (nor does it mandate that emissions
during any given hour during this period must be
below the 30-day average emission limits); rather,
MATS mandates only that sources comply with the
MATS emission standards at that time.
E:\FR\FM\19NOR1.SGM
19NOR1
rljohnson on DSK3VPTVN1PROD with RULES
68782
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
several respects. First, in the June 2013
analysis, we did not attempt to identify
the EGUs that were the best performing
sources, but instead simply looked at a
category-wide average time for
engagement of APCDs. As certain
commenters noted, the category-wide
average may not satisfy the CAA section
112(h) requirement that the EPA
establish work practice standards
‘‘which in the Administrator’s judgment
[are] consistent with the provisions of
subsections (d) or (f) of this section
[112].’’ To more appropriately track this
statutory directive, the EPA revised the
analysis and identified the EGUs that
were able to most quickly engage their
APCDs because we determined that the
best performing EGUs for purposes of
defining the end of startup are those that
are able to most efficiently engage their
controls after the start of electricity
generation. The EPA then averaged the
time it took for such EGUs to bring their
APCDs on line to determine a
reasonable time after generation of
electricity to define the end of startup.
The EPA chose this approach in the
final rule because we believe it most
closely follows the requirements of CAA
section 112.
The EPA analysis of startup events at
coal-fired EGUs indicates that the best
performing EGUs can, on average,
initiate operation of their SO2 and NOX
APCDs within 4 hours following the
start of generation (see Technical
Support Document (TSD) titled
‘‘Assessment of startup period at coalfired electric generating units—Revised’’
in Docket ID No. EPA–HQ–OAR–2009–
0234). In addition, the Agency is
confident that stack conditions at this
time are conducive for accurate
measurements of HAP emissions using
CEMS. For these reason, and because
SO2 can be used as a surrogate for the
control of acid gases and SO2 and NOX
APCDs can impact the control of Hg
emissions, and because we believe
based on comments and other
information that SO2 and NOX controls
are generally the last APCDs to be
engaged, the EPA has determined that
the end of startup should be defined as
the end of the 4th hour following the
start of generation of electricity or useful
thermal energy. The agency has also
determined that it is not necessary to
include any additional variability
because the agency believes it has
information on all of the startup events
from the EGUs with the relevant data so
startup time variability is fully
represented in the available data.
b. Shutdown. The EPA is maintaining
the definition of ‘‘shutdown’’ proposed
in the November 2012 action, and
further requiring that all APCDs must be
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
operated as long as coal, residual oil, or
solid oil-derived fuel is being fired in
the EGU and as long thereafter as
possible, considering safety and system
integrity.
The RTC contains a summary of the
comments received on this topic and the
EPA’s response to those comments.
2. Work Practice Standards and Clean
Fuels
The final work practice for startup
periods requires EGUs to initiate startup
using clean fuels and to combust only
clean fuels until primary fuel (e.g., coal,
residual oil, or solid oil-derived fuel) is
fed into the EGU, at which time the EGU
must engage and operate its PM controls
as soon as possible and no later than 1
hour thereafter. After engagement of PM
controls, EGUs are required to maintain
maximum clean fuel use until the end
of startup (i.e., 4 hours after the start of
generation of electricity or useful
thermal energy). The maximization of
clean fuel use after addition of primary
fuel to the EGU assures that the least
amount of HAP possible will be emitted
from the units during the startup period.
The final rule also includes more fuels
on the list of clean fuels that may be
combusted during startup periods and
shutdown periods, as discussed below.
The EPA is finalizing a requirement in
the work practice that PM controls be
engaged and operated within 1 hour of
coal, residual oil, or solid oil-derived
fuel being fired. In the November 2012
proposal, the EPA proposed to require
that once an EGU starts firing coal,
residual oil, or solid oil-derived fuel, all
of the applicable control devices had to
be engaged, with certain listed
exceptions. PM-specific control devices
were not included in that list of
excepted controls because the EPA
believed that PM controls on EGUs
could be engaged (i.e., operational) at
the best performing EGUs at the time the
primary fuel (i.e., coal, residual oil, or
solid oil-derived fuel) is fired. The EPA
has reviewed both the record and the
comments received, and we have
determined that the EGUs that are able
to engage PM controls (through either
use of PM-specific controls (e.g., ESP,
FF) or wet FGD scrubber system alone
or in conjunction with PM controls)
within 1 hour following the initiation of
firing of coal, residual oil, or solid oilderived fuel are the best performing
sources for purposes of minimizing
particulate HAP emissions during
startup periods.10 Therefore, we are
finalizing a requirement that an owner/
operator must engage and operate the
10 Docket ID Nos. EPA–HQ–OAR–2009–0234–
20269, EPA–HQ–OAR–2009–0234–20275.
PO 00000
Frm 00020
Fmt 4700
Sfmt 4700
PM controls within 1 hour of first firing
of coal, residual oil, or solid oil-derived
fuel.
Moreover, in order to demonstrate an
EGU’s capacity to maximize the use of
clean fuels during startup periods and
its ability to bring PM control devices
online in an expeditious manner
following first firing of coal, residual oil,
or solid oil-derived fuel, the rule now
requires EGU owners or operators to
determine and report each EGU’s
maximum storage capacity for clean
fuels and maximum capacity for heat
input while combusting clean fuels
alone. The rule also requires EGU
owners or operators to identify, record,
and report semiannually each instance
of startup or shutdown, specifying the
dates and times that clean fuel use
begins and ends; the dates and times
that primary (i.e., coal or oil) fuel use
starts or ends; and the hourly clean fuel
usage, heat input, and electrical output.
In addition, for those non-liquid oilfired EGUs not using PM CEMS, HAP
metals CEMS, or PM continuous
parameter monitoring system (CPMS) as
a compliance determination method or
not meeting low emitting EGU (LEE)
status 11 for PM or non-mercury HAP
metals emissions or those liquid oilfired EGUs not using PM CEMS or PM
CPMS as a compliance determination
method or not meeting LEE status for
PM or HAP metals emissions,
parametric monitoring data will be
required to help show PM control
device effectiveness upon first use of
coal, residual oil, or solid oil-derived
fuel. This type of data is not required
from EGUs using PM CEMS, HAP
metals CEMS, or PM CPMS, as those
instruments are already required to
provide these data during startup
periods; those data are suitable for
assessing how soon and how well PM
control devices are operating. Likewise,
once EGUs meet the LEE status for PM
or non-mercury HAP metals emissions
for non-liquid oil-fired EGUs (or HAP
metals emissions for liquid oil-fired
EGUs), they will no longer need to
supply additional information regarding
PM control device operation during
startup periods, for it is reasonable to
expect their PM control devices to be
properly sized and operated in order to
demonstrate consistent operation at less
than 50 percent of the emissions limit
over a 3-year period. It is also
reasonable to expect that the
information recorded and calculated
during startup periods and shutdown
periods from LEE-eligible EGUs will
show better emissions performance
11 See
E:\FR\FM\19NOR1.SGM
40 CFR 63.10005(h).
19NOR1
rljohnson on DSK3VPTVN1PROD with RULES
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
when compared to similar information
obtained from EGUs without LEE status.
Upon initiation of first use of coal,
residual oil, or solid oil-derived fuel,
EGUs not using PM CEMS or PM CPMS
as a compliance determination method
or not meeting LEE status for PM or
non-mercury HAP metals emissions for
non-liquid oil-fired EGUs (or HAP
metals emissions for liquid oil-fired
EGUs) are also required to record hourly
and report semi-annually the pre- and
post-PM control device flow rates and
temperatures, as well as fan amps.
Moreover, the PM control devicespecific parameters are required to be
recorded hourly and reported semiannually. The EGUs with ESPs are
required to record the number of fields
in service and the secondary current
and voltage for each hour of startup and
shutdown. The EGUs with FFs are
required to record the number of
compartments in service and the
differential pressure across the
baghouse. Finally, the EGUs with wet
scrubbers that are necessary for
filterable PM emission control will
record scrubber liquid-to-flue gas ratios
and scrubber liquid differential pressure
for each hour of startup and shutdown.
Given that we do not have much
information concerning continuous PM
emissions or PM emission control
devices during periods of startup, the
final rule requires owners or operators
of EGUs that choose to use definition (2)
of ‘‘startup’’ contained in 40 CFR
63.10042 to provide a report prepared
by an independent professional
engineer that describes the EGU, PM
emissions, and PM emissions control
devices both as designed and in their
current form. This information will
show how each EGU is able, or has been
modified, to meet the requirements of
this rule. In addition, the information
will specify the time needed to engage
PM emission control devices from
initial fuel combustion in the EGU; the
effectiveness of each PM emission
control device, both upon control device
startup and at normal operation; the PM
emission rate; and the uncontrolled PM
emissions rate. The report will be
submitted as part of the EGU’s
Notification of Compliance Status, and
the information contained in the report
will aid us in determining whether or
not additional work practice
requirements may be needed during
startup periods to minimize HAP
emissions.
Finally, the EPA acknowledges the
comments asserting safety issues that
must be considered during startup of
PM controls (e.g., carbon monoxide
buildup, fabric blinding). We believe
that almost all EGUs will be able to alter
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
their source through any number of
means, including increasing clean fuel
capacity and modifying APCD
operation, and comply with the final
work practice requirements; however,
we recognize that there may be rare
occasions that preclude a viable
compliance option consistent with the
final rule. Therefore, we are finalizing
that an owner/operator may submit to
the Administrator a request for an EGUspecific case-by-case emission standard
consistent with 40 CFR 63.6(g). Such a
request requires notice-and-comment
rulemaking. Approval or disapproval
authority for this type of request is
delegated to the Assistant Administrator
of the Office of Air and Radiation, and,
for purposes of this rule, will be
delegated no further.12 However, the
EPA will only consider requests that
provide evidence of a documented
manufacturer-identified safety issue and
can provide proof that the PM control
device is adequately designed and sized
to meet the final PM emission limit. As
identified in 40 CFR 63.10011(g)(4), in
its request for the case-by-case
determination, the owner/operator must
provide, among other materials,
documentation that: (1) The EGU is
using clean fuels to the maximum extent
possible to bring the EGU and PM
control device up to the temperature
necessary to alleviate or prevent the
identified safety issues prior to the
combustion of primary fuel in the EGU,
(2) the EGU has explicitly followed the
manufacturer’s procedures to alleviate
or prevent the identified safety issue, (3)
the source provides details of the
manufacturer’s statement of concern,
and (4) the source provides evidence
that the PM control device is adequately
designed and sized to meet the final PM
emission limit. In addition, the source
will have to indicate the other measures
it will take to limit HAP emissions
during startup periods and shutdown
periods to ensure a control level
consistent with the final work practice
requirements. In order to ensure
compliance with the work practice
standards during startup periods, EGU
owners or operators who request an
alternative non-opacity emission
standard shall comply with definition
(1) of startup contained in 40 CFR
63.10042 (i.e., the definition contained
in the final rule promulgated on
February 12, 2012) 13 until the final
alternative non-opacity emission
12 See Delegation 7–121 and Delegation of
Authority under the Clean Air Act to Approve
Alternatives to Test Methods and Procedures in
Parts 60, 61, 63, and 65, from Gina McCarthy to
Stephen Page, September 30, 2011, in docket ID
EPA–HQ–OAR–2009–0234.
13 See 77 FR 9303; February 16, 2012.
PO 00000
Frm 00021
Fmt 4700
Sfmt 4700
68783
standard is promulgated in the Federal
Register.
We also proposed several revisions to
the work practice standards issued in
the final MATS rule in response to
petitions on the final rule. Petitioners
asserted that the final rule’s work
practice standards should include
additional fuels as ‘‘clean fuels’’ and
recognize operating limitations of
certain EGU types and APCDs.
Specifically, petitioners contended that
the list of clean fuels required for use
during startup in order to minimize
emissions should include, among
others, synthetic natural gas, synthesis
gas (syngas), biodiesel, and ultra-low
sulfur diesel (ULSD). The EPA has also
been informed that propane is used to
startup some EGUs.
In this final action, we are adding
certain synthetic natural gas (that meets
the specification necessary for that gas
to be transported on a Federal Energy
Regulatory Commission (FERC)
regulated pipeline), synthesis gas that
has been processed through a gas cleanup train such that it is suitable for use
in the system’s combustion turbine, and
ULSD to the list of clean fuels. In
addition, the EPA does see merit, as
suggested by some commenters, of
further broadening the definition of
‘‘clean fuels.’’ After reviewing other
rules that use or require clean fuels, we
believe that inclusion of those fuels
meeting the requirements of 40 CFR Part
80, subpart I (‘‘Subpart I—Motor Vehicle
Diesel Fuel; Nonroad, Locomotive, and
Marine Diesel Fuel; and ECA Marine
Fuel’’) is appropriate. Specifically, the
definitions and provisions of 40 CFR
80.2, 80.501, 80.510, and 80.520 address
sulfur content restrictions relating to
distillate, diesel (including ULSD), and
biodiesel fuels. The EPA believes that
requiring use of clean fuels, including
those we are adding in this final rule,
for EGUs will significantly limit the
HAP emissions from these sources
during startup periods and shutdown
periods. For example, information
provided to the EPA on another
rulemaking (found in Docket ID No.
EPA–HQ–OAR–2008–0708–1459) 14
showed that the use of ULSD will
significantly reduce emissions of air
toxics, including metallic HAP (e.g.,
nickel, zinc, lead (Pb)) compared to the
use of ‘‘regular’’ diesel. The EPA also
believes that combustion of the other 40
CFR Part 80, subpart I, fuels meeting the
subject definitions will cause
significantly lower HAP emissions than
14 Email and attachments from Paul Miller,
NESCAUM, to Melanie King, EPA. NESCAUM’s
RICE NESHAP comments. October 11, 2012, also
found in Docket ID No. EPA–HQ–OAR–2009–0234.
E:\FR\FM\19NOR1.SGM
19NOR1
68784
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
rljohnson on DSK3VPTVN1PROD with RULES
coal and residual oil, and, as stated
above, EGUs must use clean fuels to the
maximum extent possible during startup
periods and shutdown periods.
We are maintaining the work practice
requirement in the final MATS that
requires EGU source owners and
operators, when firing coal, residual oil,
or solid oil-derived fuel in the EGU
during startup or shutdown, to vent
emissions to the main stack(s) and
operate all control devices necessary to
meet all operating and emissions
standards that are applicable to the
source pursuant to other CAA or state
requirements. In addition, any partial
(fractional) operating hour that may
occur at the beginning of a startup
period or at the end of a shutdown
period is to be flagged in reports as an
hour of startup or shutdown.
For more discussion of each of these
issues, please refer to the RTC, the TSD,
and the memo ‘‘Startup and shutdown
provisions’’ (Docket ID No. EPA–HQ–
OAR–2009–0234–20224) in Docket ID
No. EPA–HQ–OAR–2009–0234.
3. Treatment of IGCC EGU Syngas
The EPA is finalizing both the use of
flares and the use of duct burners for
integrated gasification combined cycle
(IGCC) units to handle syngas not
combusted in the turbine during startup
periods and shutdown periods.
An IGCC EGU includes both a
gasification unit and a combustion unit
and syngas is generated in the gasifier
for the primary purpose of being
combusted in the associated combustion
turbine. The EPA understands that, in
some cases, the gasified fuel can be used
for other purposes such as the
production of chemicals (e.g., fertilizers,
methanol) if the facility has been
designed to do so. During the startup
periods and shutdown periods, some or
all of the syngas produced for the
purpose of power production may not
be combusted in the turbine. We
proposed two options for IGCC EGUs for
handling syngas not fired in the
combustion turbine: (1) Syngas must be
flared, not vented, or (2) syngas must be
routed to duct burners, which may need
to be installed, and the flue gas from the
duct burners must be routed to the heat
recovery steam generator. We solicited
comments on the need to flare the
unfired syngas, if it is more appropriate
to require routing of the unfired syngas
back into the system for all IGCC EGUs,
and on the costs of adding duct burners,
should they be required.
Industry commenters stated that it is
important that flaring remain an option
for routine startups and shutdowns for
safety reasons and as a viable option for
non-routine events such as EGU ‘‘trips’’
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
when the combustion turbine cannot
combust syngas. Commenters noted that
the flaring option is especially critical as
the re-routing option can only be used
by IGCC EGUs under limited
circumstances as the syngas may lack
sufficient pressure for re-injection and
gasifiers are often once-through systems
that do not support re-routing of the
syngas. Commenters indicated that the
actual flaring step of an IGCC startup is
relatively short and ordinarily lasts less
than 2 hours and that only clean syngas
is flared during a routine startup.
The EPA is finalizing both options,
use of flaring or duct burners, for
handling of syngas not combusted in the
turbine during startup periods and
shutdown periods.15 The EPA believes
that the controls are comparable and
that allowing the option will provide
flexibility to owners/operators of IGCC
EGUs to choose either of the options
subject to operational constraints at
their IGCC EGUs. The EPA believes it
appropriate to cover gasifier syngas
during startup periods and shutdown
periods of the combustion turbine
portion of the IGCC because the units
are inextricably linked and the unused
gas would not be generated but for the
startup of the combustion portion of the
IGCC unit. The EPA is requiring the use
of either flares or duct burners to
combust unused syngas during startup
periods and shutdown periods.
4. Common Stacks
The final MATS rule at 40 CFR
63.10010(a)(1), (2), and (3) required
owners or operators of EGUs with
common stacks to either monitor the
EGUs separately or monitor the common
stack and assign the same emissions
value to each EGU. No specific
requirements concerning monitoring
during startup periods or shutdown
periods were given because the EPA
believed the provisions as finalized
were sufficient. Consistent with the
monitoring provisions in the final rule,
owners or operators of EGUs with
common stacks are required to monitor
and report emissions for compliance
purposes at all times when any EGU
using a common stack is operating in a
non-startup/shutdown mode, even if
another EGU using that common stack
is in startup/shutdown mode. 40 CFR
63.10005(a)(2)(iii) reinforces and
clarifies this requirement. Also,
consistent with the final rule, work
practice standards, rather than numeric
emissions limits, apply during startup
periods or shutdown periods, but only
15 IGCC units that are also designed to co-produce
chemicals or other products using syngas may also
choose to use the unburned syngas in that process.
PO 00000
Frm 00022
Fmt 4700
Sfmt 4700
to EGUs in startup or shutdown mode.
Today’s reconsidered rule maintains the
approach of the final rule. Owners or
operators of EGUs with common stacks
may either monitor each EGU separately
upstream of the common stack or from
the common stack. Monitoring must be
operational (except for periods of
monitor malfunction and during
required quality assurance (QA) and
maintenance activities) at all times that
any fuel is being combusted, and
compliance with numeric emission
limits is required except for periods
when all EGUs sharing the common
stack are in startup or shutdown mode.
Should an owner or operator choose to
monitor the common stack, then
emissions obtained from the monitoring
will be applied to each EGU that shares
the stack. This approach remains
consistent with the final rule, and is not
expected to be problematic emissionswise for any EGU using a common
stack, because the EGUs in startup
periods or shutdown periods are
required to use clean fuels and comply
with the other work practice
requirements. In addition, the EGUs
sharing the common stack and operating
in a mode other than startup or
shutdown are required to operate such
that they meet their emissions limits.
We believe, based on evaluation of
source compliance for many years, that
sources generally operate in a manner to
ensure a compliance margin to avoid
potential exceedances.16 Thus, we
maintain the monitoring options
available in the final rule are sufficient
to address concerns from commenters.
As discussed below, the EPA is also
establishing a default electrical load of
5 percent of the maximum sustainable
electrical load of the EGU. This default
value will be allowed to be used during
periods of startup or periods of
shutdown when the electrical load is
zero. For EGUs sharing a common stack
with just one common monitoring
system, this default value will be
available only when the electrical load
is zero for an EGU sharing the common
stack that is in a period of startup or
shutdown. As soon as a non-zero
electrical load is produced, that nonzero load must be used in electrical
output-based emission rate calculations
for each EGU in a startup or shutdown
period, even if the load is less than 5
percent of capacity. Note that the
electrical load of all EGUs in operation
and sharing a common stack with just
16 ‘‘. . . (S)ources do not design to meet a
standard, but rather to meet a level comfortably
lower. They do so in order to provide a compliance
margin on those days where emissions rise due to
inherent and uncontrollable variability . . .’’ See 77
FR 42386; July 18, 2012.
E:\FR\FM\19NOR1.SGM
19NOR1
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
rljohnson on DSK3VPTVN1PROD with RULES
one common monitoring system are to
be summed when electrical outputbased emission rate calculations are
made.
Section 1.2.5 of the RTC contains both
a summary of comments received on
this topic and the EPA’s response to
those comments.
5. Diluent Cap
Apart from allowing use of a diluent
cap when calculating Hg emissions
during startup periods or shutdown
periods, the final rule contained no
allowance for use of a diluent cap. The
November 2012 proposal sought
comment on the need for a diluent cap
for other HAP emissions during startup
periods and shutdown periods. Use of a
diluent cap can be important during
startup periods and shutdown periods
because CEMS values can approach
infinity because the denominator in the
calculations for CEMS values can
approach zero during those periods.
Moreover, use of a diluent cap becomes
a common stack issue when one or more
of the EGUs is in a startup or shutdown
mode and just one monitoring
instrument is used in the stack.
The EPA considered each comment
and decided to allow use of default
carbon dioxide (CO2) or oxygen (O2)
values as identified in Section 3.3.4.1 of
Appendix F of 40 CFR part 75, but only
for startup periods or shutdown periods
when CO2 values are below or O2 values
are above default values for use in all
pollutant calculations. For non-IGCC
EGUs, the default CO2 value is 5 percent
and the default O2 value is 14 percent.
This means that when CEMS CO2
measurements are below 5 percent, EGU
owners or operators are allowed to use
5 percent CO2 in their calculations.
Because the startup analysis showed
that CEMS CO2 measurements exceeded
default values within 2 hours of
generation, the EPA does not expect to
find default values being used when
startup periods end. Likewise, when
CEMS O2 measurements are larger than
14 percent, EGU owners or operators
will be able to use 14-percent O2 in their
calculations. IGCC EGUs will be
allowed to use 1 percent as a default
CO2 value or 19 percent as a default O2
value. As mentioned earlier, default
diluent gas values will be allowed for
use in calculations for startup periods or
shutdown periods when CO2 CEMS
values are below or O2 CEMS values are
above default values. The rule requires
EGU owners or operators to use actual
CO2 or O2 CEMS values for all other
operating periods. Although the EPA
has no specific data or information
concerning emissions during transient
events outside startup or shutdown
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
periods, the EPA expects the short
duration of these transient events
outside startup or shutdown periods
that could cause CO2 or O2 CEMS to be
below (or above) default values to have
little, if any, impact on the 30-boiler
operating day rolling averages.
The rule retains the requirement for
EGU owners or operators to report
instrumental CEMS, PM CPMS, and
sorbent trap information, as well as flow
rate information during startup periods
or shutdown periods. Such information
may prove useful in assessing potential
emissions or operational limits in future
rulemaking activities. Finally, the rule
requires EGU owners or operators to
identify each hour of startup or
shutdown in which a diluent cap value
is used.
Section 5.1 of the RTC contains both
a summary of comments received on
this topic and the EPA’s response.
6. Default Electrical Output
The final rule provided no allowance
regarding default electrical output. The
November 2012 proposal sought
comment on the need for a default
electrical output for those owners or
operators who choose to comply with a
mass per electrical output standard. Use
of a default electrical output cap can be
important during startup periods and
shutdown periods because the
calculated mass per electrical output
values can approach infinity when the
electrical output is zero during those
periods.
Upon consideration of the comments,
the rule will provide a default electrical
load value that EGU owners or operators
will be allowed to use during startup
periods or shutdown periods to
calculate emissions rates for an EGU, as
long as the electrical load for the EGU
is zero. Once the EGU begins generating
electricity, the source must use the
actual electrical output in compliance
calculations, even if the output is below
the 5 percent default value. Moreover,
use of a default electrical load is not
allowed during periods other than
startup or shutdown. As suggested by
one commenter, the default electrical
load will be equivalent to 5 percent of
the maximum sustainable electrical
output in megawatts of an EGU, as
defined in section 6.5.2.1(a)(1) of
appendix A to part 75, and included in
an EGU’s Part 75 electronic monitoring
plan. This maximum sustainable load is
either the nameplate capacity of the
EGU or the highest electrical load
observed in at least four representative
quarters of EGU operation. When used
in a common stack application, the
default electrical load is 5 percent of the
combined maximum sustainable
PO 00000
Frm 00023
Fmt 4700
Sfmt 4700
68785
electrical load of the EGUs that are in
startup or shutdown mode during an
hour in which the electrical load is zero.
The default electrical load is allowed to
be used in electrical output-based
emission rate calculations (either
pounds per megawatt-hour (lb/MWh) or
pounds per gigawatt-hour (lb/GWh)) for
any hour in which the actual electrical
load for a single EGU or for every EGU
venting to a common stack is zero. The
EPA considered, but decided against,
requiring measurement of thermal heat
output and conversion back into
equivalent electrical output; instead, the
EPA decided to use a simpler approach
based on already-existing requirements
of the Acid Rain Program that we
believe are most appropriate
considering CAA section 112 and in
light of the available data. Finally, the
rule requires EGU owners or operators
to identify each hour of startup or
shutdown in which a default electrical
load value is used.
Section 5.2 of the RTC contains both
a summary of comments received on
this topic and the EPA’s response to
significant comments.
7. Use of Sorbent Traps
The final rule required continuous Hg
data collection using sorbent traps or Hg
CEMS under all process operating
conditions, including, but not limited
to, startup periods and shutdown
periods, over the entire 30 boiler
operating day LEE qualification testing
period. For sorbent traps, the EPA
allowed use of redundant backup
sorbent trap monitoring systems during
startup periods and shutdown periods;
and required operation of sorbent trap
monitoring systems and collection of Hg
data at all times EGUs operate, but did
not allow use of Hg data collected
during startup or shutdown periods to
be included in compliance calculations.
After consideration of comments
received on Hg monitoring during
startup or shutdown periods using
sorbent trap monitoring systems, the
EPA decided that the final reconsidered
rule will contain three alternative
approaches for measuring Hg emissions
during startup periods or shutdown
periods. In the first approach, EGU
owners or operators will continue to be
able to use Hg CEMS for measuring Hg
emissions.
The second approach relies on at least
two separate sorbent monitoring
systems. Although the rule has no
prohibition against an EGU owner or
operator using one sorbent trap
monitoring system for compliance
purposes during periods other than
startup or shutdown and one (or more)
sorbent trap monitoring systems for
E:\FR\FM\19NOR1.SGM
19NOR1
rljohnson on DSK3VPTVN1PROD with RULES
68786
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
startup periods or shutdown periods
through the use of a non-redundant
backup system (per section 2.2.2 of
Appendix A to subpart UUUUU of Part
63), it will be clarified that two separate
sorbent monitoring systems are allowed.
Reliance on this second approach would
address one commenter’s concern that
Hg compliance data could not be
separated from Hg data collected during
startup and/or shutdown periods when
demonstrating compliance with
numerical standards based on a sorbent
trap system. When an EGU with at least
two such systems (one for startup
periods or shutdown periods and the
other for all other periods) entered into
a startup or shutdown period, the EGU
owner or operator could switch
monitoring systems either manually or
automatically. As part of an EGU owner
or operator’s rubric for choosing which
Hg measurement approach to use, the
EGU owner or operator should take into
account that any process operating hour
for which quality assured Hg
concentration data are not obtained is
counted as an hour of monitoring
system downtime, per section 1.4 of
Appendix A to subpart UUUUU of Part
63. Therefore, if an EGU owner or
operator believes change-out of sorbent
monitoring traps may take too long,
other approaches may be more suitable.
An EGU owner or operator should
carefully consider all costs—not only of
sorbent tubes, analyses, and associated
labor, but also of non-compliance due to
data gaps, when determining whether
this approach is appropriate.
The third approach, relying on just
one sorbent trap monitoring system for
all periods of operation (startup,
shutdown, and normal), will be
identified in the rule as a viable option
for Hg monitoring, and, for EGU owners
or operators who choose this option, the
rule will allow data collected during
startup or shutdown periods to be used
for compliance purposes. The EPA
expects little impact on Hg emissions
during startup or shutdown periods,
because, as explained above, we believe
the rule contains sufficient variability to
include startup and shutdown periods;
clean fuels will be used during those
periods; default diluent and electrical
output values, which tend to constrain
emissions, will be available for use; and
emissions occurring during those
periods will be included in a 30(or 90-) boiler operating day rolling
average. EGU owners or operators may
find that this third approach would
work well for those instances in which
sudden and unpredictable shutdown
events occur, for there would be no
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
need to swap sorbent trap monitoring
systems to capture shutdown emissions.
Finally, the EPA disagrees with
commenters who claim that collecting
data during startup and shutdown will
serve no purpose relative to compliance
with MATS and indicated that if the
EPA needs to collect startup and
shutdown data to better understand
performance for a future rulemaking,
that can be addressed through the
information collection request (ICR)
process where the EPA demonstrates the
need and identifies a systematic plan to
gather the data. As explained in the
final rule preamble,17 collection of
startup and shutdown information will
provide the EPA with information to
more fully analyze the ability and
appropriateness of establishing numeric
emissions and operating limits during
startup periods or shutdown periods so
the issue can be addressed as part of the
ongoing 8-year review of this rule.
Collection of these data as part of the
rule will also serve to reduce, if not
eliminate, future ICR requests on this
topic. The EPA also disagrees with
commenters who wish to place all
startup and shutdown information on
those EGU owners or operators who
choose to use Hg CEMS, for EPA
remains interested in how well sorbent
tube monitoring systems operate during
startup periods or shutdown periods.
Not collecting that information from
those systems would leave a gap in the
EPA’s knowledge base.
Section 5.3 of the RTC contains both
a summary of comments received on
this topic and the EPA’s response to
significant comments.
V. Summary of Final Action and
Changes Since Proposal—Utility NSPS
The current PM startup and shutdown
requirements in the Utility NSPS are
included in 40 CFR 60.42Da(e)(2) and
require the owner/operator of an
affected EGU to meet the work practice
standards specified in Table 3 of 40 CFR
Part 63, subpart UUUUU (i.e., the MATS
rule). The Utility NSPS docket received
a total of 23 public comments on the
startup/shutdown reconsideration
proposal. One of these comments was a
duplicate. Of the remaining 22
comments, 15 were received in both
dockets, and 7 were received in the
Utility NSPS docket alone. Of the seven
comments received in the Utility NSPS
docket alone, four were said to be sent
to the MATS docket, but no documents
that matched the ones in the Utility
NSPS docket were found in the MATS
docket. However, the majority of the
comments overlap with issues raised as
17 See
PO 00000
77 FR 9382 (February 16, 2012).
Frm 00024
Fmt 4700
Sfmt 4700
part of the startup and shutdown
provision included in MATS. The EPA
responses to these issues are discussed
in the MATS portion of the preamble
and docket and have not been repeated
here or in the Utility NSPS docket.
The sole NSPS-specific comment we
received was that the Utility NSPS
should include a definition of startup
and shutdown that is consistent with
the MATS definition and that the
definitions of startup and shutdown in
the Utility NSPS, MATS, and Industrial
Boiler NESHAP (subpart DDDDD) rules
should be consistent. There are
situations where a facility is subject to
the PM standard under 40 CFR Part 60,
subpart Da, but is not subject to MATS
(e.g., a biomass-fired EGU with natural
gas burners >250 million British thermal
units per hour). This facility would,
therefore, be subject to the Industrial
Boiler NESHAP. We have concluded
that it is appropriate for industrial
boilers and EGUs to have the same PM
startup and shutdown work practice
standards for both the NSPS and MATS.
Therefore, we are amending 40 CFR
60.42Da(e)(2) so that owners or
operators of facilities subject to 40 CFR
Part 63, subpart UUUUU, shall meet the
work practice standards specified in
Table 3 to Subpart UUUUU of Part 63,
and owners or operators of facilities
subject to 40 CFR Part 63, subpart
DDDDD, shall meet the work practice
standards specified in Table 3 to
Subpart DDDDD of Part 63.
We are also amending the regulatory
text in the Utility NSPS to incorporate
the relevant startup and shutdown
definitions. We have concluded that the
amended regulatory text is sufficient,
and adding definitions of startup and
shutdown are not necessary for the
Utility NSPS. Using this approach is
beneficial because any future
amendments to the MATS startup and
shutdown provisions will automatically
be incorporated into the Utility NSPS.
VI. Impacts of This Final Rule
A. Summary of Emissions Impacts,
Costs and Benefits
Because this final rule is no more
stringent than the February 2012 final
rule, we expect no additional costs or
benefits associated with these revisions.
B. What are the air impacts?
This final rule is no more stringent
than the February 2012 final rule.
Accordingly, we believe that this final
action will not result in significant
changes in emissions of any of the
regulated pollutants.
E:\FR\FM\19NOR1.SGM
19NOR1
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
C. What are the energy impacts?
This final action is not anticipated to
have an effect on the supply,
distribution, or use of energy. As
previously stated, this final rule is no
more stringent than the February 2012
final rule.
D. What are the compliance costs?
We believe there will be no significant
change in compliance costs as a result
of this final action because electric
power companies would take the same
or similar actions (e.g., operating control
devices, recording clean fuel use, etc.)
as they would have to comply with the
previously finalized MATS standards.
Moreover, we find no additional
monitoring costs are necessary to
comply with this final action because
EGU owners or operators could
continue to use the startup and
shutdown provisions of the
promulgated rule to demonstrate
compliance; however, as in any other
rule, EGU owners or operators may
choose to conduct additional
monitoring (and incur its expense) for
their own purposes.
E. What are the economic and
employment impacts?
Because we expect that electric power
companies would take the same or
similar actions to meet the requirements
finalized in this action as they would
have chosen to comply with the
previously finalized MATS standards,
we do not anticipate that this final
action will result in significant changes
in emissions, energy impacts, costs,
benefits, or economic impacts. Likewise,
we believe this action will not have any
impacts on the price of electricity,
employment or labor markets, or the
U.S. economy.
F. What are the benefits of the final
standards?
As previously stated, we do not
anticipate any significant emission
changes resulting from this action.
Therefore, there are no direct monetized
benefits or disbenefits associated with
this action.
rljohnson on DSK3VPTVN1PROD with RULES
VII. Statutory and Executive Order
Reviews
A. Executive Order 12866: Regulatory
Planning and Review and Executive
Order 13563: Improving Regulation and
Regulatory Review
This action is not a ‘‘significant
regulatory action’’ under the terms of
Executive Order 12866 (58 FR 51735;
October 4, 1993) and is, therefore not
subject to review under Executive
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
Orders 12866 and 13563 (76 FR 3821;
January 21, 2011).
Because this final rule is no more
stringent than the February 2012 final
rule, we do not expect any additional
costs, benefits, or economic impacts
associated with these revisions. The
EPA prepared an analysis of the
potential costs and benefits associated
with the 2012 final rule. This analysis
is contained in the ‘‘Economic Impact
Analysis for the Final Reconsideration
of the Mercury and Air Toxics
Standards’’ found in Docket ID No.
EPA–HQ–OAR–2009–0234.
B. Paperwork Reduction Act
This action does not impose any new
information collection burden. This
action clarifies but does not change the
information collection requirements
previously finalized and, as a result,
does not impose any additional burden
on industry. However, the Office of
Management and Budget (OMB) has
previously approved the information
collection requirements contained in the
existing regulations (see 77 FR 9304)
under the provisions of the Paperwork
Reduction Act, 44 U.S.C. 3501 et seq.
and has assigned OMB control number
2060–0567. The OMB control numbers
for EPA’s regulations are listed in 40
CFR part 9.
C. Regulatory Flexibility Act
The Regulatory Flexibility Act
generally requires an agency to prepare
a regulatory flexibility analysis of any
rule subject to notice and comment
rulemaking requirements under the
Administrative Procedure Act or any
other statute unless the agency certifies
that the rule will not have a significant
economic impact on a substantial
number of small entities. Small entities
include small businesses, small
organizations, and small governmental
jurisdictions.
For purposes of assessing the impacts
of this action on small entities, a small
entity is defined as: (1) A small business
as defined by the Small Business
Administration’s (SBA) regulations at 13
CFR 121.201; (2) a small governmental
jurisdiction that is a government of a
city, county, town, school district, or
special district with a population of less
that 50,000; and (3) a small organization
that is any not-for-profit enterprise
which is independently owned and
operated and is not dominant in its
field. Categories and entities potentially
regulated by the final rule with
applicable NAICS codes are provided in
section I.A of this preamble.
According to the SBA size standards
for NAICS code 221122, Utilities—
Fossil Fuel Electric Power Generation, a
PO 00000
Frm 00025
Fmt 4700
Sfmt 4700
68787
firm is small if, including its affiliates,
it is primarily engaged in the generation,
transmission, and/or distribution of
electric energy for sale and its total
electric output for the preceding fiscal
year did not exceed 4 million MWh.
After considering the economic
impacts of this final rule on small
entities, I certify that this action will not
have a significant economic impact on
a substantial number of small entities.
The EPA has determined that none of
the small entities will experience a
significant impact because the action
imposes no additional regulatory
requirements on owners or operators of
affected sources.
D. Unfunded Mandates Reform Act
This action contains no federal
mandates under the provisions of Title
II of the Unfunded Mandates Reform
Act of 1995 (UMRA), 2 U.S.C. 1531–
1538 for state, local, or tribal
governments or the private sector. The
action imposes no enforceable duty on
any state, local, or tribal governments or
the private sector. Therefore, this action
is not subject to the requirements of
UMRA sections 202 or 205.
This action is also not subject to the
requirements of UMRA section 203
because it contains no regulatory
requirements that might significantly or
uniquely affect small governments. This
action contains no requirements that
apply to such governments or impose
obligations upon them.
E. Executive Order 13132: Federalism
This action does not have federalism
implications. It will not have substantial
direct effects on the states, on the
relationship between the national
government and the states, or on the
distribution of power and
responsibilities among the various
levels of government, as specified in
Executive Order 13132. Thus, Executive
Order 13132 does not apply to this
action.
F. Executive Order 13175: Consultation
and Coordination With Indian Tribal
Governments
This action does not have tribal
implications as specified in Executive
Order 13175 (65 FR 67249; November 9,
2000). It will not have substantial direct
effects on tribal governments, on the
relationship between the federal
government and Indian tribes, or on the
distribution of power and
responsibilities between the federal
government and Indian tribes, as
specified in Executive Order 13175. No
affected facilities are owned or operated
by Indian tribal governments. Thus,
E:\FR\FM\19NOR1.SGM
19NOR1
68788
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
Executive Order 13175 does not apply
to this action.
G. Executive Order 13045: Protection of
Children From Environmental Health
Risks and Safety Risks
This action is not subject to Executive
Order 13045 (62 FR 19885; April 23,
1997) because it is not economically
significant as defined in Executive
Order 12866. The EPA has evaluated the
environmental health or safety effects of
the final MATS on children. The results
of the evaluation are discussed in that
final rule (77 FR 9304; February 16,
2012) and are contained in Docket ID
No. EPA–HQ–OAR–2009–0234.
H. Executive Order 13211: Actions That
Significantly Affect Energy Supply,
Distribution, or Use
This action is not subject to Executive
Order 13211 (66 FR 28355; May 22,
2001) because it is not a significant
regulatory action under Executive Order
12866.
I. National Technology Transfer and
Advancement Act
Section 12(d) of the National
Technology Transfer and Advancement
Act of 1995 (NTTAA); Public Law 104–
113, 12(d) (15 U.S.C. 272 note) directs
the EPA to use voluntary consensus
standards (VCS) in their regulatory and
procurement activities unless to do so
would be inconsistent with applicable
law or otherwise impracticable. VCS are
technical standards (e.g., material
specifications, test methods, sampling
procedures, and business practices) that
are developed or adopted by VCS
bodies. The NTTAA requires the EPA to
provide Congress, through OMB,
explanations when the agency decides
not to use available and applicable VCS.
This action does not involve VCS.
Therefore, the EPA did not consider the
use of any VCS.
rljohnson on DSK3VPTVN1PROD with RULES
J. Executive Order 12898: Federal
Actions To Address Environmental
Justice in Minority Populations and
Low-Income Populations
14:12 Nov 18, 2014
Jkt 235001
K. Congressional Review Act
The Congressional Review Act, 5
U.S.C. 801 et seq., as added by the Small
Business Regulatory Enforcement
Fairness Act of 1996, generally provides
that before a rule may take effect, the
agency promulgating the rule must
submit a rule report, which includes a
copy of the rule, to each House of the
Congress and to the Comptroller General
of the United States. The EPA will
submit a report containing this final rule
and other required information to the
U.S. Senate, the U.S. House of
Representatives, and the Comptroller
General of the United States prior to
publication of the rule in the Federal
Register. A major rule cannot take effect
until 60 days after it is published in the
Federal Register. This action is not a
‘‘major rule’’ as defined by 5 U.S.C.
804(2). This final rule will be effective
on November 19, 2014.
List of Subjects
40 CFR Part 60
Environmental protection,
Administrative practice and procedure,
Air pollution control, Intergovernmental
relations, Reporting and recordkeeping
requirements.
Environmental protection,
Administrative practice and procedure,
Air pollution control, Hazardous
substances, Intergovernmental relations,
Reporting and recordkeeping
requirements.
Dated: November 7, 2014.
Gina McCarthy,
Administrator.
For the reasons discussed in the
preamble, the EPA amends 40 CFR parts
60 and 63 to read as follows:
PO 00000
Frm 00026
Fmt 4700
PART 60—STANDARDS OF
PERFORMANCE FOR NEW
STATIONARY SOURCES
1. The authority citation for 40 CFR
part 60 continues to read as follows:
■
Authority: 42 U.S.C. 7401 et seq.
2. Section 60.42Da is amended by
revising paragraph (e)(2) to read as
follows:
■
§ 60.42Da
(PM).
Standards for particulate matter
*
*
*
*
*
(e) * * *
(2) During startup periods and
shutdown periods, owners or operators
of facilities subject to subpart UUUUU
of part 63 of this chapter shall meet the
work practice standards specified in
Table 3 to subpart UUUUU of part 63
and use the relevant definitions in
§ 63.10042, and owners or operators of
facilities subject to subpart DDDDD of
part 63 shall meet the work practice
standards specified in Table 3 to subpart
DDDDD of part 63 and use the relevant
definition used in § 63.7575.
*
*
*
*
*
PART 63—NATIONAL EMISSION
STANDARDS FOR HAZARDOUS AIR
POLLUTANTS FOR SOURCE
CATEGORIES
3. The authority citation for 40 CFR
part 63 continues to read as follows:
■
Authority: 42 U.S.C. 7401 et seq.
4. Section 63.10000 is amended by
revising paragraph (c)(1)(vi) and adding
paragraph (l) to read as follows:
■
§ 63.10000 What are my general
requirements for complying with this
subpart?
40 CFR Part 63
Executive Order 12898 (59 FR 7629;
February 16, 1994) establishes federal
executive policy on environmental
justice. Its main provision directs
federal agencies, to the greatest extent
practicable and permitted by law, to
make environmental justice part of their
mission by identifying and addressing,
as appropriate, disproportionately high
and adverse human health or
environmental effects of their programs,
policies, and activities on minority
populations and low-income
populations in the United States.
VerDate Sep<11>2014
The EPA has determined that this
final rule will not have
disproportionately high and adverse
human health or environmental effects
on minority, low-income, or indigenous
populations because it does not affect
the level of protection provided to
human health or the environment. The
EPA has evaluated the environmental
health or environmental effects of the
final MATS on minority, low-income, or
indigenous populations. The results of
the evaluation are discussed in that final
rule (77 FR 9304; February 16, 2012)
and are contained in Docket ID No.
EPA–HQ–OAR–2009–0234.
Sfmt 4700
*
*
*
*
*
(c)(1) * * *
(vi) If your coal-fired or solid oilderived fuel-fired EGU does not qualify
as a LEE for Hg, you must demonstrate
initial and continuous compliance
through use of a Hg CEMS or a sorbent
trap monitoring system, in accordance
with appendix A to this subpart.
(A) You may choose to use separate
sorbent trap monitoring systems to
comply with this subpart: One sorbent
trap monitoring system to demonstrate
compliance with the numeric mercury
emissions limit during periods other
than startup or shutdown and the other
sorbent trap monitoring system to report
average mercury concentration during
startup periods or shutdown periods.
(B) You may choose to use one
sorbent trap monitoring system to
demonstrate compliance with the
mercury emissions limit at all times
E:\FR\FM\19NOR1.SGM
19NOR1
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
(including startup periods and
shutdown periods) and to report average
mercury concentration. You must follow
the startup or shutdown requirements
that follow and as given in Table 3 to
this subpart for each coal-fired, liquid
oil-fired, or solid oil-derived fuel-fired
EGU.
*
*
*
*
*
(l) On or before the date an EGU is
subject to this subpart, you must install,
certify, operate, maintain, and quality
assure each monitoring system
necessary for demonstrating compliance
with the work practice standards for PM
or non-mercury HAP metals during
startup periods and shutdown periods.
You must collect, record, report, and
maintain data obtained from these
monitoring systems during startup
periods and shutdown periods.
■ 5. Section 63.10005 is amended by
revising paragraph (a)(2) to read as
follows:
rljohnson on DSK3VPTVN1PROD with RULES
§ 63.10005 What are my initial compliance
requirements and by what date must I
conduct them?
(a) * * *
(2) To demonstrate initial compliance
using either a CMS that measures HAP
concentrations directly (i.e., an Hg, HCl,
or HF CEMS, or a sorbent trap
monitoring system) or an SO2 or PM
CEMS, the initial performance test
consists of 30- (or, if emissions
averaging for Hg is used, 90-) boiler
operating days of data collected by the
initial compliance demonstration date
specified in § 63.9984(f) with the
certified monitoring system. Pollutant
emission rates measured during startup
periods and shutdown period (as
defined in § 63.10042) are not to be
included in the compliance
demonstration, except as otherwise
provided in § 63.10000(c)(1)(vi)(B) and
paragraph (a)(2)(iii) of this section.
(i) The 30- (or, if applicable, 90-)
boiler operating day CMS performance
test must demonstrate compliance with
the applicable Hg, HCl, HF, PM, or SO2
emissions limit in Table 1 or 2 to this
subpart.
(ii) You must collect hourly data from
auxiliary monitoring systems (i.e., stack
gas flow rate, CO2, O2, or moisture, as
applicable) during the performance test
period, in order to convert the pollutant
concentrations to units of the standard.
If you choose to comply with an
electrical output-based emission limit,
you must also collect hourly electrical
load data during the performance test
period.
(iii) For a group of affected units that
are in the same subcategory, are subject
to the same emission standards, and
share a common stack, if you elect to
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
demonstrate compliance by monitoring
emissions at the common stack, startup
and shutdown emissions (if any) that
occur during the 30-(or, if applicable,
90-) boiler operating day performance
test must either be excluded from or
included in the compliance
demonstration as follows:
(A) If one of the units that shares the
stack either starts up or shuts down at
a time when none of the other units is
operating, you must exclude all
pollutant emission rates measured
during the startup or shutdown period,
unless you are using a sorbent trap
monitoring system to measure Hg
emissions and have elected to include
startup and shutdown emissions in the
compliance demonstrations;
(B) If all units that are currently
operating are in the startup or shutdown
mode, you must exclude all pollutant
emission rates measured during the
startup or shutdown period, unless you
are using a sorbent trap monitoring
system to measure Hg emissions and
have elected to include startup and
shutdown emissions in the compliance
demonstrations; or
(C) If any unit starts up or shuts down
at a time when another unit is operating,
and the other unit is not in the startup
or shutdown mode, you must include
all pollutant emission rates measured
during the startup or shutdown period
in the compliance demonstrations.
*
*
*
*
*
■ 6. Section 63.10007 is amended by
revising paragraph (a)(1), redesignating
paragraph (f) as paragraph (g), and
adding a new paragraph (f) to read as
follows:
§ 63.10007 What methods and other
procedures must I use for the performance
tests?
(a) * * *
(1) If you use CEMS (Hg, HCl, SO2, or
other) to determine compliance with a
30- (or, if applicable, 90-) boiler
operating day rolling average emission
limit, you must collect quality- assured
CEMS data for all unit operating
conditions, including startup and
shutdown (see § 63.10011(g) and Table
3 to this subpart), except as otherwise
provided in § 63.10020(b). Emission
rates determined during startup periods
and shutdown periods (as defined in
§ 63.10042) are not to be included in the
compliance determinations, except as
otherwise provided in
§§ 63.10000(c)(1)(vi)(B) and
63.10005(a)(2)(iii).
*
*
*
*
*
(f) If you elect to (or are required to)
use CEMS to continuously monitor Hg,
HCl, HF, SO2, or PM emissions (or, if
PO 00000
Frm 00027
Fmt 4700
Sfmt 4700
68789
applicable, sorbent trap monitoring
systems to continuously collect Hg
emissions data), the following default
values are available for use in the
emission rate calculations during
startup periods or shutdown periods (as
defined in § 63.10042). For the purposes
of this subpart, these default values are
not considered to be substitute data.
(1) Diluent cap values. If you use
CEMS (or, if applicable, sorbent trap
monitoring systems) to comply with a
heat input-based emission rate limit,
you may use the following diluent cap
values for a startup or shutdown hour in
which the measured CO2 concentration
is below the cap value or the measured
O2 concentration is above the cap value:
(i) For an IGCC EGU, you may use 1%
for CO2 or 19% for O2.
(ii) For all other EGUs, you may use
5% for CO2 or 14% for O2.
(2) Default electrical load. If you use
CEMS to continuously monitor Hg, HCl,
HF, SO2, or PM emissions (or, if
applicable, sorbent trap monitoring
systems to continuously collect Hg
emissions data), the following default
value is available for use in the emission
rate calculations during startup periods
or shutdown periods (as defined in
§ 63.10042). For the purposes of this
subpart, this default value is not
considered to be substitute data. For a
startup or shutdown hour in which
there is heat input to an affected EGU
but zero electrical load, you must
calculate the pollutant emission rate
using a value equivalent to 5% of the
maximum sustainable electrical output,
expressed in megawatts, as defined in
section 6.5.2.1(a)(1) of Appendix A to
part 75 of this chapter. This default
electrical load is either the nameplate
capacity of the EGU or the highest
electrical load observed in at least four
representative quarters of EGU
operation. For a monitored common
stack, the default electrical load is used
only when all EGUs are operating (i.e.,
combusting fuel) are in startup or
shutdown mode, and have zero
electrical generation. Under those
conditions, a default electrical load
equal to 5% of the combined maximum
sustainable electrical load of the EGUs
that are operating but have a total of
zero electrical load must be used to
calculate the hourly electrical outputbased pollutant emissions rate.
*
*
*
*
*
■ 7. Section 63.10010 is amended by
revising paragraph (f)(4) and adding
paragraph (l) to read as follows:
§ 63.10010 What are my monitoring,
installation, operation, and maintenance
requirements?
*
E:\FR\FM\19NOR1.SGM
*
*
19NOR1
*
*
68790
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
(f) * * *
(4) Use only unadjusted, qualityassured SO2 concentration values in the
emissions calculations; do not apply
bias adjustment factors to the part 75
SO2 data and do not use part 75
substitute data values. For startup or
shutdown hours (as defined in
§ 63.10042) the default electrical load
and the diluent cap are available for use
in the hourly SO2 emission rate
calculations, as described in
§ 63.10007(f). Use a flag to identify each
startup or shutdown hour and report a
special code if the diluent cap or default
electrical load is used to calculate the
SO2 emission rate for any of these hours.
*
*
*
*
*
(l) You must install, certify, operate,
maintain, and quality assure each
monitoring system necessary for
demonstrating compliance with the PM
or non-mercury metals work practice
standards for startup periods.
(1) You shall develop a site-specific
monitoring plan for PM or non-mercury
metals work practice monitoring during
startup periods.
(2) You shall submit the site-specific
monitoring plan upon request by the
Administrator.
(3) The provisions of the monitoring
plan must address the following items:
(i) Monitoring system installation;
(ii) Performance and equipment
specifications;
(iii) Schedule for initial and periodic
performance evaluations;
(iv) Performance evaluation
procedures and acceptance criteria;
(v) On-going operation and
maintenance procedures; and
(vi) On-going recordkeeping and
reporting procedures.
(4) You may rely on monitoring
system specifications or instructions to
address paragraphs (l)(3)(i) through (vi)
of this section.
(5) You must operate and maintain
the monitoring system according to the
site-specific monitoring plan.
■ 8. Section 63.10011 is amended by
revising paragraph (g) to read as follows:
§ 63.10011 How do I demonstrate initial
compliance with the emission limits and
work practice standards?
rljohnson on DSK3VPTVN1PROD with RULES
*
*
*
*
*
(g) You must follow the startup or
shutdown requirements as given in
Table 3 to this subpart for each coalfired, liquid oil-fired, or solid oilderived fuel-fired EGU.
(1) You may use the diluent cap and
default electrical load values, as
described in § 63.10007(f), during
startup periods or shutdown periods.
(2) You must operate all CMS, collect
data, calculate pollutant emission rates,
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
and record data during startup periods
or shutdown periods.
(3) You must report the information as
required in § 63.10031.
(4) If you choose to use paragraph (2)
of the definition of ‘‘startup’’ in
§ 63.10042 and you find that you are
unable to safely engage and operate your
particulate matter (PM) control(s) within
1 hour of first firing of coal, residual oil,
or solid oil-derived fuel, you may
choose to rely on paragraph (1) of
definition of ‘‘startup’’ in § 63.10042 or
you may submit a request to use an
alternative non-opacity emissions
standard, as described below.
(i) As mentioned in § 63.6(g)(1), the
request will be published in the Federal
Register for notice and comment
rulemaking. Until promulgation in the
Federal Register of the final alternative
non-opacity emission standard, you
shall comply with paragraph (1) of the
definition of ‘‘startup’’ in § 63.10042.
You shall not implement the alternative
non-opacity emissions standard until
promulgation in the Federal Register of
the final alternative non-opacity
emission standard.
(ii) The request need not address the
items contained in § 63.6(g)(2).
(iii) The request shall provide
evidence of a documented
manufacturer-identified safely issue.
(iv) The request shall provide
information to document that the PM
control device is adequately designed
and sized to meet the PM emission limit
applicable to the EGU.
(v) In addition, the request shall
contain documentation that:
(A) The EGU is using clean fuels to
the maximum extent possible to bring
the EGU and PM control device up to
the temperature necessary to alleviate or
prevent the identified safety issues prior
to the combustion of primary fuel in the
EGU;
(B) The EGU has explicitly followed
the manufacturer’s procedures to
alleviate or prevent the identified safety
issue; and
(C) Identifies with specificity the
details of the manufacturer’s statement
of concern.
(vi) The request shall specify the other
work practice standards the EGU owner
or operator will take to limit HAP
emissions during startup periods and
shutdown periods to ensure a control
level consistent with the work practice
standards of the final rule.
(vii) You must comply with all other
work practice requirements, including
but not limited to data collection,
recordkeeping, and reporting
requirements.
PO 00000
Frm 00028
Fmt 4700
Sfmt 4700
9. Section 63.10020 is amended by
revising paragraph (c) and adding
paragraph (e) to read as follows:
■
§ 63.10020 How do I monitor and collect
data to demonstrate continuous
compliance?
*
*
*
*
*
(c) You may not use data recorded
during EGU startup or shutdown in
calculations used to report emissions,
except as otherwise provided in
§§ 63.10000(c)(1)(vi)(B) and
63.10005(a)(2)(iii). In addition, data
recorded during monitoring system
malfunctions or monitoring system outof-control periods, repairs associated
with monitoring system malfunctions or
monitoring system out-of-control
periods, or required monitoring system
quality assurance or control activities
may not be used in calculations used to
report emissions or operating levels.
You must use all of the quality-assured
data collected during all other periods
in assessing the operation of the control
device and associated control system.
*
*
*
*
*
(e) Additional requirements during
startup periods or shutdown periods.
(1) During each period of startup, you
must record for each EGU:
(i) The date and time that clean fuels
being combusted for the purpose of
startup begins;
(ii) The quantity and heat input of
clean fuel for each hour of startup;
(iii) The electrical load for each hour
of startup;
(iv) The date and time that non-clean
fuel combustion begins; and
(v) The date and time that clean fuels
being combusted for the purpose of
startup ends.
(2) During each period of shutdown,
you must record for each EGU:
(i) The date and time that clean fuels
being combusted for the purpose of
shutdown begins;
(ii) The quantity and heat input of
clean fuel for each hour of shutdown;
(iii) The electrical load for each hour
of shutdown;
(iv) The date and time that non-clean
fuel combustion ends; and
(v) The date and time that clean fuels
being combusted for the purpose of
shutdown ends.
(3) For PM or non-mercury HAP
metals work practice monitoring during
startup periods, you must monitor and
collect data according to this section
and the site-specific monitoring plan
required by § 63.10011(l).
(i) Except for an EGU that uses PM
CEMS or PM CPMS to demonstrate
compliance with the PM emissions limit
or that has LEE status for filterable PM
or total non-Hg HAP metals for non-
E:\FR\FM\19NOR1.SGM
19NOR1
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
liquid oil-fired EGUs (or HAP metals
emissions for liquid oil-fired EGUs), or
individual non-mercury metals CEMS
you must:
(A) Record temperature and flow rate
of post-combustion (exhaust) gas and
amperage of forced draft fan(s) upstream
of each filterable PM control device
during each hour of startup.
(B) Record temperature and flow rate
of exhaust gas and amperage of induced
draft fan(s) downstream of each
filterable control device during each
hour of startup.
(C) For an EGU with an electrostatic
precipitator, record the number of fields
in service, as well as each field’s
secondary voltage and secondary
current during each hour of startup.
(D) For an EGU with a fabric filter,
record the number of compartments in
service, as well as the differential
pressure across the baghouse during
each hour of startup.
(E) For an EGU with a wet scrubber
needed for filterable PM control, record
the scrubber liquid to fuel ratio and the
differential pressure of the liquid during
each hour of startup.
(ii) [Reserved]
■ 10. Section 63.10021 is amended by
revising paragraph (h) to read as
follows:
§ 63.10021 How do I demonstrate
continuous compliance with the emission
limitations, operating limits, and work
practice standards?
rljohnson on DSK3VPTVN1PROD with RULES
*
*
*
*
*
(h) You must follow the startup or
shutdown requirements as given in
Table 3 to this subpart for each coalfired, liquid oil-fired, or solid oilderived fuel-fired EGU.
(1) You may use the diluent cap and
default electrical load values, as
described in § 63.10007(f), during
startup periods or shutdown periods.
(2) You must operate all CMS, collect
data, calculate pollutant emission rates,
and record data during startup periods
or shutdown periods.
(3) You must report the information as
required in § 63.10031.
(4) You may choose to submit an
alternative non-opacity emission
standard, in accordance with the
requirements contained in
§ 63.10011(g)(4). Until promulgation in
the Federal Register of the final
alternative non-opacity emission
standard, you shall comply with
paragraph (1) of the definition of
‘‘startup’’ in § 63.10042.
*
*
*
*
*
■ 11. Section 63.10022 is amended by
revising the introductory text of
paragraph (a) and adding paragraph
(a)(4) to read as follows:
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
§ 63.10022 How do I demonstrate
continuous compliance under the
emissions averaging provision?
(a) Following the compliance date, the
owner or operator must demonstrate
compliance with this subpart on a
continuous basis by meeting the
requirements of paragraphs (a)(1)
through (4) of this section.
*
*
*
*
*
(4) For each existing EGU
participating in the emissions averaging
option, operate in accordance with the
startup or shutdown work practice
requirements given in Table 3 to this
subpart.
*
*
*
*
*
■ 12. Section 63.10030 is amended by
revising the introductory text of
paragraph (e) and adding paragraph
(e)(8) to read as follows:
§ 63.10030 What notifications must I
submit and when?
*
*
*
*
*
(e) When you are required to conduct
an initial compliance demonstration as
specified in § 63.10011(a), you must
submit a Notification of Compliance
Status according to § 63.9(h)(2)(ii). The
Notification of Compliance Status report
must contain all the information
specified in paragraphs (e)(1) through
(8) of this section, as applicable.
*
*
*
*
*
(8) Identification of whether you plan
to rely on paragraph (1) or (2) of the
definition of ‘‘startup’’ in § 63.10042.
(i) Should you choose to rely on
paragraph (2) of the definition of
‘‘startup’’ in § 63.10042 for your EGU,
you shall include a report that
identifies:
(A) The original EGU installation
date;
(B) The original EGU design
characteristics, including, but not
limited to, fuel and PM controls;
(C) Each design PM control device
efficiency;
(D) The design PM emission rate from
the EGU in terms of pounds PM per
MMBtu and pounds PM per hour;
(E) The design time from start of fuel
combustion to necessary conditions for
each PM control device startup;
(F) Each design PM control device
efficiency upon startup of the PM
control device;
(G) The design EGU uncontrolled PM
emission rate in terms of pounds PM per
hour;
(H) Each change from the original
design that did or could have changed
PM emissions, including, but not
limited to, each different fuel mix, each
revision to each PM control device, and
each EGU revision, along with the
PO 00000
Frm 00029
Fmt 4700
Sfmt 4700
68791
month and year that the change
occurred;
(I) Current EGU PM producing
characteristics, including, but not
limited to, fuel mix and PM controls;
(J) Current PM emission rate from the
EGU in terms of pounds PM per MMBtu
and pounds per hour;
(K) Current PM control device
efficiency from each PM control device;
(L) Current time from start of fuel
combustion to conditions necessary for
each PM control device startup;
(M) Current PM control device
efficiency upon startup of each PM
control device; and
(N) Current EGU uncontrolled PM
emission rate in terms of pounds PM per
hour.
(ii) The report shall be prepared,
signed, and sealed by a professional
engineer licensed in the state where
your EGU is located. Apart from
preparing, signing, and sealing this
report, the professional engineer shall
be independent and not otherwise
employed by your company, any parent
company of your company, or any
subsidiary of your company.
■ 13. Section 63.10031 is amended by
revising the introductory text of
paragraph (c) and adding paragraph
(c)(5) to read as follows:
§ 63.10031
when?
What reports must I submit and
*
*
*
*
*
(c) The compliance report must
contain the information required in
paragraphs (c)(1) through (5) of this
section.
*
*
*
*
*
(5) For each instance of startup or
shutdown:
(i) Include the maximum clean fuel
storage capacity and the maximum
hourly heat input that can be provided
for each clean fuel determined
according to the requirements of
§ 63.10032(f).
(ii) Include the information required
to be monitored, collected, or recorded
according to the requirements of
§ 63.10020(e).
(iii) If you choose to use CEMS for
compliance purposes, include hourly
average CEMS values and hourly
average flow rates. Use units of
milligrams per cubic meter for PM
CEMS, micrograms per cubic meter for
Hg CEMS, and ppmv for HCl, HF, or
SO2 CEMS. Use units of standard cubic
meters per hour on a wet basis for flow
rates.
(iv) If you choose to use a separate
sorbent trap measurement system for
startup or shutdown reporting periods,
include hourly average mercury
E:\FR\FM\19NOR1.SGM
19NOR1
68792
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
concentration in terms of micrograms
per cubic meter.
(v) If you choose to use a PM CPMS,
include hourly average operating
parameter values in terms of the
operating limit, as well as the operating
parameter to PM correlation equation.
*
*
*
*
*
■ 14. Section 63.10032 is amended by
revising paragraph (f) to read as follows:
§ 63.10032
What records must I keep?
*
*
*
*
*
(f) Regarding startup periods or
shutdown periods:
(1) You must keep records of the
occurrence and duration of each startup
or shutdown;
(2) You must keep records of the
determination of the maximum clean
fuel capacity for each EGU;
(3) You must keep records of the
determination of the maximum hourly
clean fuel heat input and of the hourly
clean fuel heat input for each EGU; and
(4) You must keep records of the
information required in § 63.10020(e).
*
*
*
*
*
■ 15. In § 63.10042:
■ a. Revise the definitions for ‘‘Boiler
operating day,’’ ‘‘Shutdown’’, and
‘‘Startup’’; and
■ b. Add in alphabetical order new
definitions for ‘‘Clean fuel,’’ ‘‘Default
electrical load,’’ and ‘‘Diluent cap.’’
The revisions and additions read as
follows:
§ 63.10042
subpart?
What definitions apply to this
*
*
*
*
*
Boiler operating day means a 24-hour
period that begins at midnight and ends
the following midnight during which
any fuel is combusted at any time in the
EGU, excluding startup periods or
shutdown periods. It is not necessary for
the fuel to be combusted the entire 24hour period.
*
*
*
*
*
Clean fuel means natural gas,
synthetic natural gas that meets the
specification necessary for that gas to be
transported on a Federal Energy
Regulatory Commission (FERC)
regulated pipeline, propane, distillate
oil, synthesis gas that has been
processed through a gas clean-up train
such that it could be used in a system’s
combustion turbine, or ultra-low-sulfur
diesel (ULSD) oil, including those fuels
meeting the requirements of 40 CFR part
80, subpart I (‘‘Subpart I—Motor Vehicle
Diesel Fuel; Nonroad, Locomotive, and
Marine Diesel Fuel; and ECA Marine
Fuel’’).
*
*
*
*
*
Default electrical load means an
electrical load equal to 5 percent of the
maximum sustainable electrical output
(megawatts), as defined in section
6.5.2.1(a)(1) of Appendix A to part 75 of
this chapter, of an affected EGU that is
in startup or shutdown mode. For
monitored common stack
configurations, the default electrical
load is 5 percent of the combined
maximum sustainable electrical load of
the EGUs that are in startup or
shutdown mode during an hour in
which the electrical load for all
operating EGUs is zero. The default
electrical load is used to calculate the
electrical output-based emission rate
(lb/MWh or lb/GWh, as applicable) for
any startup or shutdown hour in which
the actual electrical load is zero. The
default electrical load is not used for
EGUs required to make heat input-based
emission rate (lb/MMBtu or lb/TBtu, as
applicable) calculations. For the
purposes of this subpart, the default
electrical load is not considered to be a
substitute data value.
*
*
*
*
*
Diluent cap means a default CO2 or O2
concentration that may be used to
calculate the Hg, HCl, HF, or SO2
emission rate (lb/MMBtu or lb/TBtu, as
applicable) during a startup or
shutdown hour in which the measured
CO2 concentration is below the cap
value or the measured O2 concentration
is above the cap value. The appropriate
diluent cap values for EGUs are
presented in § 63.10007(f) and in section
6.2.1.2 of Appendix A to this subpart.
For the purposes of this subpart, the
diluent cap is not considered to be a
substitute data value.
*
*
*
*
*
Shutdown means the period in which
cessation of operation of an EGU is
initiated for any purpose. Shutdown
begins when the EGU no longer
generates electricity or makes useful
thermal energy (such as heat or steam)
for industrial, commercial, heating, or
cooling purposes or when no coal,
liquid oil, syngas, or solid oil-derived
fuel is being fired in the EGU,
whichever is earlier. Shutdown ends
when the EGU no longer generates
electricity or makes useful thermal
energy (such as steam or heat) for
industrial, commercial, heating, or
cooling purposes, and no fuel is being
fired in the EGU. Any fraction of an
hour in which shutdown occurs
constitutes a full hour of shutdown.
Startup means:
(1) Either the first-ever firing of fuel
in a boiler for the purpose of producing
electricity, or the firing of fuel in a
boiler after a shutdown event for any
purpose. Startup ends when any of the
steam from the boiler is used to generate
electricity for sale over the grid or for
any other purpose (including on-site
use). Any fraction of an hour in which
startup occurs constitutes a full hour of
startup; or
(2) The period in which operation of
an EGU is initiated for any purpose.
Startup begins with either the firing of
any fuel in an EGU for the purpose of
producing electricity or useful thermal
energy (such as heat or steam) for
industrial, commercial, heating, or
cooling purposes (other than the firstever firing of fuel in a boiler following
construction of the boiler) or for any
other purpose after a shutdown event.
Startup ends 4 hours after the EGU
generates electricity that is sold or used
for any other purpose (including on site
use), or 4 hours after the EGU makes
useful thermal energy (such as heat or
steam) for industrial, commercial,
heating, or cooling purposes (16 U.S.C.
796(18)(A) and 18 CFR 292.202(c)),
whichever is earlier. Any fraction of an
hour in which startup occurs constitutes
a full hour of startup.
*
*
*
*
*
■ 16. Revise Table 3 to subpart UUUUU
of part 63 to read as follows:
rljohnson on DSK3VPTVN1PROD with RULES
TABLE 3 TO SUBPART UUUUU OF PART 63—WORK PRACTICE STANDARDS
[As stated in § 63.9991, you must comply with the following applicable work practice standards:]
If your EGU is . . .
You must meet the following . . .
1. An existing EGU .............................................
Conduct a tune-up of the EGU burner and combustion
months, or each 48 calendar months if neural network
employed, as specified in § 63.10021(e).
Conduct a tune-up of the EGU burner and combustion
months, or each 48 calendar months if neural network
employed, as specified in § 63.10021(e).
2. A new or reconstructed EGU .........................
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
PO 00000
Frm 00030
Fmt 4700
Sfmt 4700
E:\FR\FM\19NOR1.SGM
controls at least each 36 calendar
combustion optimization software is
controls at least each 36 calendar
combustion optimization software is
19NOR1
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
68793
TABLE 3 TO SUBPART UUUUU OF PART 63—WORK PRACTICE STANDARDS—Continued
[As stated in § 63.9991, you must comply with the following applicable work practice standards:]
If your EGU is . . .
You must meet the following . . .
3. A coal-fired, liquid oil-fired (excluding limiteduse liquid oil-fired subcategory units), or solid
oil-derived fuel-fired EGU during startup.
You have the option of complying using either of the following work practice standards.
(1) If you choose to comply using paragraph (1) of the definition of ‘‘startup’’ in § 63.10042,
you must operate all CMS during startup. Startup means either the first-ever firing of fuel in
a boiler for the purpose of producing electricity, or the firing of fuel in a boiler after a shutdown event for any purpose. Startup ends when any of the steam from the boiler is used to
generate electricity for sale over the grid or for any other purpose (including on site use).
For startup of a unit, you must use clean fuels as defined in § 63.10042 for ignition. Once
you convert to firing coal, residual oil, or solid oil-derived fuel, you must engage all of the
applicable control technologies except dry scrubber and SCR. You must start your dry
scrubber and SCR systems, if present, appropriately to comply with relevant standards applicable during normal operation. You must comply with all applicable emissions limits at all
times except for periods that meet the applicable definitions of startup and shutdown in this
subpart. You must keep records during startup periods. You must provide reports concerning activities and startup periods, as specified in § 63.10011(g) and § 63.10021(h) and
(i).
(2) If you choose to comply using paragraph (2) of the definition of ‘‘startup’’ in § 63.10042,
you must operate all CMS during startup. You must also collect appropriate data, and you
must calculate the pollutant emission rate for each hour of startup.
For startup of an EGU, you must use one or a combination of the clean fuels defined in
§ 63.10042 to the maximum extent possible throughout the startup period. You must have
sufficient clean fuel capacity to engage and operate your PM control device within one hour
of adding coal, residual oil, or solid oil-derived fuel to the unit. You must meet the startup
period work practice requirements as identified in § 63.10020(e).
Once you start firing coal, residual oil, or solid oil-derived fuel, you must vent emissions to the
main stack(s). You must comply with the applicable emission limits within 4 hours of start of
electricity generation. You must engage and operate your particulate matter control(s) within
1 hour of first firing of coal, residual oil, or solid oil-derived fuel.
You must start all other applicable control devices as expeditiously as possible, considering
safety and manufacturer/supplier recommendations, but, in any case, when necessary to
comply with other standards made applicable to the EGU by a permit limit or a rule other
than this Subpart that require operation of the control devices.
Relative to the syngas not fired in the combustion turbine of an IGCC EGU during startup, you
must either: (1) flare the syngas, or (2) route the syngas to duct burners, which may need to
be installed, and route the flue gas from the duct burners to the heat recovery steam generator.
If you choose to use just one set of sorbent traps to demonstrate compliance with Hg emission
limits, you must comply with all applicable Hg emission limits at all times; otherwise, you
must comply with all applicable emission limits at all times except for startup or shutdown
periods conforming to this practice. You must collect monitoring data during startup periods,
as specified in § 63.10020(a) and (e). You must keep records during startup periods, as provided in §§ 63.10032 and 63.10021(h). Any fraction of an hour in which startup occurs constitutes a full hour of startup. You must provide reports concerning activities and startup periods, as specified in §§ 63.10011(g), 63.10021(i), and 63.10031.
You must operate all CMS during shutdown. You must also collect appropriate data, and you
must calculate the pollutant emission rate for each hour of shutdown.
While firing coal, residual oil, or solid oil-derived fuel during shutdown, you must vent emissions to the main stack(s) and operate all applicable control devices and continue to operate
those control devices after the cessation of coal, residual oil, or solid oil-derived fuel being
fed into the EGU and for as long as possible thereafter considering operational and safety
concerns. In any case, you must operate your controls when necessary to comply with other
standards made applicable to the EGU by a permit limit or a rule other than this Subpart
and that require operation of the control devices.
If, in addition to the fuel used prior to initiation of shutdown, another fuel must be used to support the shutdown process, that additional fuel must be one or a combination of the clean
fuels defined in § 63.10042 and must be used to the maximum extent possible.
Relative to the syngas not fired in the combustion turbine of an IGCC EGU during shutdown,
you must either: (1) flare the syngas, or (2) route the syngas to duct burners, which may
need to be installed, and route the flue gas from the duct burners to the heat recovery
steam generator.
You must comply with all applicable emission limits at all times except during startup periods
and shutdown periods at which time you must meet this work practice. You must collect
monitoring data during shutdown periods, as specified in § 63.10020(a). You must keep
records during shutdown periods, as provided in §§ 63.10032 and 63.10021(h). Any fraction
of an hour in which shutdown occurs constitutes a full hour of shutdown. You must provide
reports concerning activities and shutdown periods, as specified in §§ 63.10011(g),
63.10021(i), and 63.10031.
rljohnson on DSK3VPTVN1PROD with RULES
4. A coal-fired, liquid oil-fired (excluding limiteduse liquid oil-fired subcategory units), or solid
oil-derived fuel-fired EGU during shutdown.
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
PO 00000
Frm 00031
Fmt 4700
Sfmt 4700
E:\FR\FM\19NOR1.SGM
19NOR1
68794
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
17. Revise Table 9 to subpart UUUUU
of part 63 to read as follows:
■
TABLE 9 TO SUBPART UUUUU OF PART 63—APPLICABILITY OF GENERAL PROVISIONS TO SUBPART UUUUU
[As stated in § 63.10040, you must comply with the applicable General Provisions according to the following]
Citation
§ 63.1
§ 63.2
§ 63.3
§ 63.4
§ 63.5
Subject
........................................................
........................................................
........................................................
........................................................
........................................................
§ 63.6(a), (b)(1)–(5), (b)(7), (c), (f)(2)–(3),
(h)(2)–(9), (i), (j).
§ 63.6(e)(1)(i) ............................................
§ 63.6(e)(1)(ii) ...........................................
§ 63.6(e)(3) ...............................................
§ 63.6(f)(1) ................................................
§ 63.6(h)(1) ...............................................
§ 63.6(g) ...................................................
§ 63.7(e)(1) ...............................................
§ 63.8 ........................................................
§ 63.8(c)(1)(i) ............................................
§ 63.8(c)(1)(iii) ..........................................
§ 63.8(d)(3) ...............................................
§ 63.9 ........................................................
§ 63.10(a), (b)(1), (c), (d)(1)–(2), (e), and
(f).
§ 63.10(b)(2)(i) ..........................................
§ 63.10(b)(2)(ii) .........................................
§ 63.10(b)(2)(iii) ........................................
§ 63.10(b)(2)(iv) ........................................
Applies to subpart UUUUU
Applicability ...........................................
Definitions ..............................................
Units and Abbreviations ........................
Prohibited Activities and Circumvention
Preconstruction Review and Notification Requirements.
Compliance with Standards and Maintenance Requirements.
General Duty to minimize emissions ....
Requirement to correct malfunctions
ASAP.
SSM Plan requirements ........................
SSM exemption .....................................
SSM exemption .....................................
Compliance with Standards and Maintenance Requirements, Use of an alternative non-opacity emission standard.
Performance testing ..............................
Monitoring Requirements ......................
General duty to minimize emissions
and CMS operation.
Requirement to develop SSM Plan for
CMS.
Written procedures for CMS .................
Notification Requirements .....................
Recordkeeping and Reporting Requirements.
Recordkeeping of occurrence and duration of startups and shutdowns.
Recordkeeping of malfunctions .............
§ 63.10(c)(11) ...........................................
Maintenance records .............................
Actions taken to minimize emissions
during SSM.
Actions taken to minimize emissions
during SSM.
Recordkeeping for CMS malfunctions ..
Other CMS requirements ......................
................................................................
Additional recordkeeping requirements
for CMS—identifying exceedances
and excess emissions.
Additional recordkeeping requirements
for CMS—identifying exceedances
and excess emissions.
Recording nature and cause of malfunctions.
Recording corrective actions .................
§ 63.10(c)(15) ...........................................
§ 63.10(d)(5) .............................................
Use of SSM Plan ..................................
SSM reports ..........................................
§ 63.11 ......................................................
§ 63.12 ......................................................
§§ 63.13–63.16 .........................................
Control Device Requirements ...............
State Authority and Delegation .............
Addresses, Incorporation by Reference,
Availability of Information, Performance Track Provisions.
Reserved ...............................................
§ 63.10(b)(2)(v) .........................................
§ 63.10(b)(2)(vi) ........................................
§ 63.10(b)(2)(vii)–(ix) ................................
§ 63.10(b)(3), and (d)(3)–(5) ....................
§ 63.10(c)(7) .............................................
§ 63.10(c)(8) .............................................
rljohnson on DSK3VPTVN1PROD with RULES
§ 63.10(c)(10) ...........................................
§§ 63.1(a)(5), (a)(7)–(9), (b)(2), (c)(3)–(4),
(d), 63.6(b)(6), (c)(3), (c)(4), (d), (e)(2),
(e)(3)(ii), (h)(3), (h)(5)(iv), 63.8(a)(3),
63.9(b)(3),
(h)(4),
63.10(c)(2)–(4),
(c)(9).
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
PO 00000
Frm 00032
Fmt 4700
Sfmt 4700
Yes.
Yes. Additional terms defined in § 63.10042.
Yes.
Yes.
Yes.
Yes.
No. See § 63.10000(b) for general duty requirement.
No.
No.
No.
No.
Yes. See §§ 63.10011(g)(4) and 63.10021(h)(4) for additional requirements.
No. See § 63.10007.
Yes.
No. See § 63.10000(b) for general duty requirement.
No.
Yes, except for last sentence, which refers to an SSM
plan. SSM plans are not required.
Yes.
Yes, except for the requirements to submit written reports
under § 63.10(e)(3)(v).
No.
No. See § 63.10001 for recordkeeping of (1) occurrence
and duration and (2) actions taken during malfunction.
Yes.
No.
No.
Yes.
Yes.
No.
Yes.
Yes.
No. See § 63.10032(g) and (h) for malfunctions recordkeeping requirements.
No. See § 63.10032(g) and (h) for malfunctions recordkeeping requirements.
No.
No. See § 63.10021(h) and (i) for malfunction reporting requirements.
No.
Yes.
Yes.
No.
E:\FR\FM\19NOR1.SGM
19NOR1
Federal Register / Vol. 79, No. 223 / Wednesday, November 19, 2014 / Rules and Regulations
18. Appendix A to subpart UUUUU is
amended by adding sections 7.1.2.5,
7.1.8.5, and 7.1.8.6, to read as follows:
■
Appendix A to Subpart UUUUU of Part
63—Hg Monitoring Provisions
*
*
*
*
*
7. Recordkeeping and Reporting
*
*
*
*
*
7.1.2 Operating Parameter Records.
* * *
*
*
*
*
*
7.1.2.5 If applicable, a flag to indicate
that the hour is a startup or shutdown
hour (as defined in § 63.10042).
*
*
*
*
*
7.1.8 Hg Emission Rate Records.
* * *
*
*
*
*
*
7.1.8.5 If applicable, a code to
indicate that the default electrical load
(as defined in § 63.10042) was used to
calculate the Hg emission rate.
7.1.8.6 If applicable, a code to
indicate that the diluent cap (as defined
in § 63.10042) was used to calculate the
Hg emission rate.
*
*
*
*
*
■ 19. Appendix B to subpart UUUUU is
amended by revising section 9.3.1 and
adding sections 10.1.2.5, 10.1.7.5, and
10.1.7.6 to read as follows:
Appendix B to Subpart UUUUU of Part
63—-HCl and HF Monitoring Provisions
rljohnson on DSK3VPTVN1PROD with RULES
*
*
*
*
*
9. Data Reduction and Calculations
*
*
*
*
*
9.3.1 For heat input-based emission
rates, select an appropriate emission
rate equation from among Equations 19–
1 through 19–9 in EPA Method 19 in
Appendix A–7 to part 60 of this chapter,
to calculate the HCl or HF emission rate
in lb/MMBtu. Multiply the HCl
concentration value (ppm) by 9.43 ×
10¥8 to convert it to lb/scf, for use in
the applicable Method 19 equation. For
HF, the conversion constant from ppm
to lb/scf is 5.18 × 10¥8. The appropriate
diluent cap value from section 6.2.1.2 of
Appendix A to this subpart may be used
to calculate the HCl or HF emission rate
(lb/MMBtu) during startup or shutdown
hours.
*
*
*
*
*
10. Recordkeeping Requirements
*
*
*
*
*
10.1.2 Operating Parameter Records.
* * *
*
*
*
*
*
10.1.2.5 If applicable, a flag to
indicate that the hour is a startup or
shutdown hour (as defined in
§ 63.10042).
*
*
*
*
*
VerDate Sep<11>2014
14:12 Nov 18, 2014
Jkt 235001
10.1.7 HCl and HF Emission Rate
Records. * * *
*
*
*
*
*
10.1.7.5 If applicable, a code to
indicate that the default electrical load
(as defined in § 63.10042) was used to
calculate the HCl or HF emission rate.
10.1.7.6 If applicable, a code to
indicate that the diluent cap (as defined
in § 63.10042) was used to calculate the
HCl or HF emission rate.
*
*
*
*
*
[FR Doc. 2014–27125 Filed 11–18–14; 8:45 am]
BILLING CODE 6560–50–P
ENVIRONMENTAL PROTECTION
AGENCY
40 CFR Part 63
[EPA–HQ–OAR–2009–0234; FRL–9919–21–
OAR]
RIN 2060–AS39
National Emission Standards for
Hazardous Air Pollutants: Coal- and
Oil-Fired Electric Steam Generating
Units
Environmental Protection
Agency.
ACTION: Direct final rule.
AGENCY:
The Environmental Protection
Agency (EPA) is taking direct final
action to amend the National Emission
Standards for Hazardous Air Pollutants:
Coal- and Oil-Fired Electric Steam
Generating Units (Mercury and Air
Toxics Standards (MATS)). This direct
final rule amends the reporting
requirements in the MATS rule by
temporarily requiring affected sources to
submit all required emissions and
compliance reports to the EPA through
the Emissions Collection and
Monitoring Plan System (ECMPS) Client
Tool and temporarily suspending the
requirement for affected sources to
submit certain reports using the
Electronic Reporting Tool and the
Compliance and Emissions Data
Reporting Interface (CEDRI).
DATES: This rule is effective on January
5, 2015 without further notice, unless
the EPA receives adverse comment by
December 19, 2014. If the EPA receives
adverse comment, we will publish a
timely withdrawal in the Federal
Register informing the public that some
or all of the amendments in the final
rule will not take effect.
ADDRESSES: Comments. Submit your
comments, identified by Docket ID
Number EPA–HQ–OAR–2009–0234, by
one of the following methods:
SUMMARY:
PO 00000
Frm 00033
Fmt 4700
Sfmt 4700
68795
• https://www.regulations.gov: Follow
the on-line instructions for submitting
comments.
• Email: a-and-r-docket@epa.gov.
Attention Docket ID Number EPA–HQ–
OAR–2009–0234.
• Fax: (202) 566–9744. Attention
Docket ID Number EPA–HQ–OAR–
2009–0234.
• Mail: U.S. Postal Service, send
comments to: U.S. Environmental
Protection Agency, EPA Docket Center,
Mail Code: 28221T, Attention Docket ID
Number EPA–HQ–OAR–2009–0234,
1200 Pennsylvania Ave. NW.,
Washington, DC 20460.
• Hand Delivery: U.S. Environmental
Protection Agency, EPA Docket Center,
Room 3334, EPA WJC West Building,
1301 Constitution Ave. NW.,
Washington, DC 20004. Attention
Docket ID Number EPA–HQ–OAR–
2009–0234. Such deliveries are only
accepted during the Docket’s normal
hours of operation, and special
arrangements should be made for
deliveries of boxed information.
Instructions. Direct your comments to
Docket ID Number EPA–HQ–OAR–
2009–0234. The EPA’s policy is that all
comments received will be included in
the public docket without change and
may be made available online at
https://www.regulations.gov, including
any personal information provided,
unless the comment includes
information claimed to be confidential
business information (CBI) or other
information whose disclosure is
restricted by statute. Do not submit
information that you consider to be CBI
or otherwise protected through https://
www.regulations.gov or email. The
https://www.regulations.gov Web site is
an ‘‘anonymous access’’ system, which
means the EPA will not know your
identity or contact information unless
you provide it in the body of your
comment. If you send an email
comment directly to the EPA without
going through https://
www.regulations.gov, your email
address will be automatically captured
and included as part of the comment
that is placed in the public docket and
made available on the Internet. If you
submit an electronic comment, the EPA
recommends that you include your
name and other contact information in
the body of your comment and with any
disk or CD–ROM you submit. If the EPA
cannot read your comment due to
technical difficulties and cannot contact
you for clarification, the EPA may not
be able to consider your comment.
Electronic files should not include
special characters or any form of
encryption and be free of any defects or
viruses. For additional information
E:\FR\FM\19NOR1.SGM
19NOR1
Agencies
[Federal Register Volume 79, Number 223 (Wednesday, November 19, 2014)]
[Rules and Regulations]
[Pages 68777-68795]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: 2014-27125]
=======================================================================
-----------------------------------------------------------------------
ENVIRONMENTAL PROTECTION AGENCY
40 CFR Parts 60 and 63
[EPA-HQ-OAR-2009-0234; EPA-HQ-OAR-2011-0044; FRL-9919-29-OAR]
RIN 2060-AS07
Reconsideration of Certain Startup/Shutdown Issues: National
Emission Standards for Hazardous Air Pollutants From Coal- and Oil-
Fired Electric Utility Steam Generating Units and Standards of
Performance for Fossil-Fuel-Fired Electric Utility, Industrial-
Commercial-Institutional, and Small Industrial-Commercial-Institutional
Steam Generating Units
AGENCY: Environmental Protection Agency.
ACTION: Final rule; notice of final action on reconsideration.
-----------------------------------------------------------------------
SUMMARY: The Environmental Protection Agency (EPA) is taking final
action on its reconsideration of the startup and shutdown provisions in
the final rules titled, ``National Emission Standards for Hazardous Air
Pollutants from Coal- and Oil-fired Electric Utility Steam Generating
Units and Standards of Performance for Fossil-Fuel-Fired Electric
Utility, Industrial-Commercial-Institutional, and Small Industrial-
Commercial-Institutional Steam Generating Units.'' The national
emission standards for hazardous air pollutants (NESHAP) issued
pursuant to Clean Air Act (CAA) section 112 are referred to as the
Mercury and Air Toxics Standards (MATS), and the new source performance
standards (NSPS) issued pursuant to CAA section 111 are referred to as
the Utility NSPS.
On November 30, 2012, the U.S. Environmental Protection Agency
(EPA) granted reconsideration of, proposed, and requested comment on a
limited set of issues in the February 16, 2012, final MATS and Utility
NSPS, including certain issues related to the final work practice
standards applicable during startup periods and shutdown periods. On
June 25, 2013, the EPA reopened the public comment period for the
reconsideration issues related to the startup and shutdown provisions
of MATS and the startup and shutdown provisions related to the
particulate matter (PM) standard in the Utility NSPS. The EPA is now
taking final action on the standards applicable during startup periods
and shutdown periods in MATS and on startup and shutdown provisions
related to the PM standard in the Utility NSPS.
DATES: The effective date of the rule is November 19, 2014.
ADDRESSES: Docket. The EPA established two dockets for this action:
Docket ID No. EPA-HQ-OAR-2011-0044 (NSPS action) and Docket ID No. EPA-
HQ-OAR-2009-0234 (MATS NESHAP action). All documents in the dockets are
listed in the https://www.regulations.gov index. Although listed in the
index, some information is not publicly available (e.g., confidential
business information (CBI) or other information whose disclosure is
restricted by statute). Certain other material, such as copyrighted
material, will be publicly available only in hard copy form. Publicly
available docket materials are available either electronically in
https://www.regulations.gov or in hard copy at the EPA Docket Center,
Room 3334, 1301 Constitution Avenue NW., Washington, DC. The Public
Reading Room is open from 8:30 a.m. to 4:30 p.m., Monday through
Friday, excluding legal holidays. The telephone number for the Public
Reading Room is (202) 566-1744, and the telephone number for the Air
Docket is (202) 566-1742.
FOR FURTHER INFORMATION CONTACT: For the MATS NESHAP action: Mr.
William Maxwell, Energy Strategies Group, Sector Policies and Programs
Division (D243-01), Office of Air Quality Planning and Standards, U.S.
Environmental Protection Agency, Research Triangle Park, North Carolina
27711; Telephone number: (919) 541-5430; Fax number (919) 541-5450;
Email address: maxwell.bill@epa.gov. For the NSPS action: Mr. Christian
Fellner, Energy Strategies Group, Sector Policies and Programs Division
(D243-01), Office of Air Quality Planning and Standards, U.S.
Environmental Protection Agency, Research Triangle Park, North Carolina
27711; Telephone number: (919) 541-4003; Fax number (919) 541-5450;
Email address: fellner.christian@epa.gov.
SUPPLEMENTARY INFORMATION:
Outline. The information presented in this preamble is organized as
follows:
I. General Information
A. Does this action apply to me?
B. How do I obtain a copy of this document?
C. Judicial Review
II. Background
III. Summary of This Action
IV. Summary of Final Action and Changes Since Proposal--MATS
Startup/Shutdown Issues
V. Summary of Final Action and Changes Since Proposal--Utility NSPS
VI. Impacts of This Final Rule
A. Summary of Emissions Impacts, Costs and Benefits
B. What are the air impacts?
C. What are the energy impacts?
D. What are the compliance costs?
E. What are the economic and employment impacts?
F. What are the benefits of the final standards?
VII. Statutory and Executive Order Reviews
A. Executive Order 12866: Regulatory Planning and Review and
Executive Order 13563: Improving Regulation and Regulatory Review
B. Paperwork Reduction Act
C. Regulatory Flexibility Act
D. Unfunded Mandates Reform Act
E. Executive Order 13132: Federalism
F. Executive Order 13175: Consultation and Coordination With
Indian Tribal Governments
G. Executive Order 13045: Protection of Children From
Environmental Health Risks and Safety Risks
H. Executive Order 13211: Actions That Significantly Affect
Energy Supply, Distribution, or Use
I. National Technology Transfer and Advancement Act
J. Executive Order 12898: Federal Actions To Address
Environmental Justice in Minority Populations and Low-Income
Populations
K. Congressional Review Act
I. General Information
A. Does this action apply to me?
Categories and entities potentially affected by this action
include:
------------------------------------------------------------------------
Examples of potentially
Category NAICS Code \1\ regulated entities
------------------------------------------------------------------------
Industry....................... 221112 Fossil fuel-fired
electric utility steam
generating units.
Federal government............. \2\ 221122 Fossil fuel-fired
electric utility steam
generating units owned
by the federal
government.
State/local/tribal government.. \2\ 221122 Fossil fuel-fired
electric utility steam
generating units owned
by municipalities.
[[Page 68778]]
921150 Fossil fuel-fired
electric utility steam
generating units in
Indian country.
------------------------------------------------------------------------
\1\ North American Industry Classification System.
\2\ Federal, state, or local government-owned and operated
establishments are classified according to the activity in which they
are engaged.
This table is not intended to be exhaustive, but rather to provide
a guide for readers regarding entities likely to be affected by this
action. To determine whether your facility, company, business,
organization, etc., would be regulated by this action, you should
examine the applicability criteria in 40 CFR 60.40, 60.40Da, or 60.40c
or in 40 CFR 63.9982. If you have any questions regarding the
applicability of this action to a particular entity, consult either the
air permitting authority for the entity or your EPA regional
representative as listed in 40 CFR 60.4 or 40 CFR 63.13 (General
Provisions).
B. How do I obtain a copy of this document?
In addition to being available in the docket, an electronic copy of
this final rule will be available on the World Wide Web (WWW) through
the Technology Transfer Network (TTN). Following signature, a copy of
the action will be posted on the TTN's policy and guidance page for
newly proposed or promulgated rules at the following address: https://www.epa.gov/ttn/oarpg/. The TTN provides information and technology
exchange in various areas of air pollution control. A copy of this
action will also be available on: www.epa.gov/mats/.
C. Judicial Review
Under CAA section 307(b)(1), judicial review of this final rule is
available only by filing a petition for review in the U.S. Court of
Appeals for the District of Columbia Circuit by January 20, 2015. Under
CAA section 307(d)(7)(B), only an objection to this final rule that was
raised with reasonable specificity during the period for public comment
can be raised during judicial review. Note, under CAA section
307(b)(2), the requirements established by this final rule may not be
challenged separately in any civil or criminal proceedings brought by
the EPA to enforce these requirements.
II. Background
On February 16, 2012, the final MATS and the Utility NSPS rules
were published in the Federal Register. 77 FR 9304. Following
promulgation of the final rules, the Administrator received petitions
for reconsideration of various provisions of both MATS and the Utility
NSPS pursuant to CAA section 307(d)(7)(B), including requests to
reconsider the work practice standards applicable during startup
periods and shutdown periods that were included in the final rule.
Copies of the MATS petitions are provided in Docket ID No. EPA-HQ-OAR-
2009-0234. Copies of the Utility NSPS petitions are provided in Docket
ID No. EPA-HQ-OAR-2011-0044. The EPA granted reconsideration of the
startup and shutdown provisions because the agency proposed to require
sources to comply with the numeric standards at all times and did not
propose a work practice standard for startup periods and shutdown
periods; thus, the public was not provided an opportunity to comment on
the work practice requirements contained in the final rule.\1\ On
November 30, 2012, the EPA published a proposed rule reconsidering
certain new source standards issued in MATS and the startup and
shutdown provisions in MATS and the Utility NSPS, among other things.
77 FR 71323. The EPA proposed certain minor changes to the startup and
shutdown provisions contained in the 2012 final rule based on
information obtained in the petitions for reconsideration. On April 24,
2013 (78 FR 24073), the EPA took final action on the new source
standards that were reconsidered and also the technical corrections
contained in the November 30, 2012, proposed action. The EPA did not
take final action on the startup and shutdown provisions, and, on June
25, 2013, the EPA added new information and analysis to the docket and
reopened the public comment period for the proposed revisions to the
startup and shutdown provisions in MATS and the startup and shutdown
provisions related to the PM standard in the Utility NSPS.
---------------------------------------------------------------------------
\1\ The EPA continues to believe that the final existing source
standards contain sufficient variability to include startup periods
and shutdown periods. Furthermore, in light of what we have learned
concerning the performance of the best performing sources during
startup and shutdown (e.g., clean fuel use and efficient engagement
of air pollution control devices (APCDs)), we believe that the best
performing electric utility steam generating units (EGUs) for
startup periods and shutdown periods will have hazardous air
pollutant (HAP) emissions that are lower than the numeric standards,
when averaged over the startup and shutdown period as defined.
However, as explained in the record, the lack of HAP data for these
periods and the current technical challenges to accurately measure
HAP emissions during startup and shutdown cause us to establish a
work practice for such periods.
---------------------------------------------------------------------------
III. Summary of This Action
This final action includes final amendments to the startup and
shutdown provisions of the final MATS and Utility NSPS issued by the
EPA on February 16, 2012. This action does not alter or reopen any
other MATS or Utility NSPS provisions, including those provisions
recently upheld by the U.S. Court of Appeals for the District of
Columbia Circuit (Court) in White Stallion Energy Center v. EPA on
April 15, 2014. 784 F.3d 1222 (D.C. Cir. 2014). The February 2012 final
rule is and remains in effect for all sources, and existing sources
must comply with the final rule by April 16, 2015, or seek an extension
of that compliance date from the appropriate title V permitting
authority.
The November 30, 2012, proposed reconsideration rule reopened,
among other things: (1) The requirements applicable during startup
periods and shutdown periods in MATS, and (2) the startup and shutdown
provisions related to the PM standard in the Utility NSPS. We are
taking final action today on the requirements for startup periods and
shutdown periods contained in 40 CFR Part 63, subpart UUUUU, and 40 CFR
Part 60, subpart Da.
As noted above, in the proposed reconsideration rule, the EPA
proposed revisions to, and took comment on, the definitions of
``startup'' and ``shutdown'' and the work practice requirements
associated with those periods in the final MATS rule. The EPA also took
comment on the startup and shutdown provisions relating to the PM
standard in the Utility NSPS. The EPA received a number of comments
regarding the proposed startup and shutdown provisions, including data
and information relevant to the proposed work practice standard that
applies during such periods, and the agency also reviewed EGU nitrogen
oxides (NOX) and sulfur dioxide (SO2) emissions
data generated during startup periods and shutdown periods and
submitted to the EPA pursuant to title IV of the CAA (i.e. the Acid
Rain Program). On June 25, 2013 (78 FR 38001), the EPA reopened the
public comment period on the startup/shutdown provision and solicited
comment on both the public comments
[[Page 68779]]
provided in response to the November 30, 2012, proposal, as well as the
startup and shutdown technical support document (TSD) that was based on
the Acid Rain Program data that was made available in the docket.\2\
The agency has reviewed all of the comments received on the startup and
shutdown issues. As described below, the EPA is taking final action on
the startup and shutdown provisions in MATS and the Utility NSPS.
---------------------------------------------------------------------------
\2\ The EPA is still reviewing the other issues raised in the
petitions for reconsideration and is not taking any action at this
time with respect to those issues.
---------------------------------------------------------------------------
Because this final rule is very similar to the February 2012 final
rule, the impacts of these revisions on the costs and the benefits of
the final rule are minor.
IV. Summary of Final Action and Changes Since Proposal--MATS Startup/
Shutdown Issues
After consideration of the public comments received and other
information, the EPA is finalizing the startup and shutdown provisions
contained in the final MATS rule and we are also finalizing an
alternative compliance option for startup periods and shutdown
periods.\3\ We address several significant comments in this preamble.
For a complete summary of the comments received on the issues we are
finalizing today and our responses thereto, please refer to the
memorandum ``National Emission Standards For Hazardous Air Pollutants
From Coal- And Oil-Fired Electric Utility Steam Generating Units--
Reconsideration Of Certain Startup/Shutdown Issues; Summary Of Public
Comments And Responses'' (RTC) in Docket ID No. EPA-HQ-OAR-2009-0234.
---------------------------------------------------------------------------
\3\ This preamble does not discuss the startup and shutdown
provisions provided in the February 2012 final MATS rule. (See 77 FR
9486, 9493-9494.) We are not altering those provisions in this final
action. However, the critical control requirement (i.e., the
requirement to use clean fuels to start and warm the EGU and
relevant controls prior to coal, residual, or solid oil-derived fuel
combustion, as well as recordkeeping and reporting procedures for
those requirements) is the same for both. We are maintaining the
final rule approach and will evaluate the continued need for the
alternative definition during our ongoing 8-year reviews. We intend
to use HAP and HAP surrogate data collected during periods of
startup and periods of shutdown to evaluate the accuracy of CEMS
from the start of electricity generation to the end of startup as
defined under the alternative included in this final rule (i.e., 4
hours after electricity generation). We will use these data to help
determine whether it is appropriate to make changes to the rule in
the future.
---------------------------------------------------------------------------
As discussed in more detail below, the alternative work practice
standard for startup periods and shutdown periods requires coal- and
oil-fired EGUs to initiate startup using only clean fuels and to
continue combusting the maximum amount of clean fuels possible at the
facility throughout the entire startup period. EGUs that chose to
comply with the alternative work practice will be required to have
sufficient clean fuel capacity to startup and warm the facility to the
point where the primary PM controls (e.g., fabric filters (FFs) and
electrostatic precipitators (ESPs)) can be brought on line at the same
time as, or within 1 hour of, the addition of the primary fuel (i.e.,
coal, residual oil, or solid oil-derived fuel) to the EGU. If a
facility does not have sufficient clean fuel capacity to enable
initiation and operation of the PM controls within 1 hour of addition
of primary fuel, then the source will have to increase its clean fuel
capacity or take other action to comply with the work practice
requirements in this final rule.\4\ The alternate included in this
final rule also requires EGUs to comply with the applicable numeric
standards within 4 hours of the generation of electricity or thermal
energy for use either on site or for sale over the grid (i.e., the end
of startup) and to continue to maximize clean fuel use throughout that
period.
---------------------------------------------------------------------------
\4\ We note that the startup and shutdown provisions contained
in the February 16, 2012, final MATS rule also required EGUs to
maximize clean fuels during startup periods and shutdown periods, as
sources are required to comply with all MATS and NSPS standards at
the time of electricity generation. Therefore, EGUs complying with
the work practice as finalized on February 16, 2012, will
necessarily be required to warm their units on clean fuels alone for
extended periods unless the operators determine that compliance over
the 30-day averaging period can be achieved without certain HAP
controls for a portion of time after the defined startup period. EGU
operators may conclude compliance without controls for a short
period after startup is possible for a number of reasons, including
the variability included in the numeric standards and our
understanding from regulating many HAP categories that sources
generally over-control to ensure a compliance margin is maintained.
---------------------------------------------------------------------------
The EPA has established these final alternative requirements after
determining what the best performing EGUs do during startup periods and
shutdown periods. The EPA used several different metrics to determine
the best performing sources for various aspects of the work practice
requirements and definitions. Specifically, concerning the use of clean
fuels, the comments received and the Acid Rain data in the record
indicate that most EGU operations start using clean fuels and that many
of those EGUs generate electricity while using clean fuels and/or
routinely engage their PM controls before or within 1 hour of beginning
to combust coal, residual oil, or solid oil-derived fuel. The clean
fuels identified by the commenters and included in the final rule are
inherently cleaner from a HAP emissions perspective than coal, residual
oil, or solid oil-derived fuel, and, for this reason, maximizing the
use of clean fuels during startup will greatly limit the emissions of
HAP while EGUs are warming up to temperatures sufficient to engage the
air pollution control devices (APCDs). Thus, we considered those EGUs
that use clean fuels for the longest period of time before the
introduction of coal and the generation of electricity to be the best
performing EGUs because they are likely to have the lowest amount of
HAP emissions during the startup period. In addition, the best
performing EGUs were also determined to be those with the ability to
engage PM control devices at the time (i.e., within 1 hour) of
introduction of primary fuel. Further, we believe all of the concerns
raised by commenters about the ability to engage the PM controls can be
safely resolved to allow compliance with the final work practice, as
explained in the RTC.\5\ We believe it is appropriate to use generation
of electricity as an indicator of startup for two reasons. First, the
information we have indicates that the only reason the owner/operator
of an EGU chooses to fire fuel in a boiler is to generate electricity.
Therefore, any event that starts with firing of fuel in a boiler that
has been shut down will culminate in generation of electricity. Second,
introduction of coal to the boiler is also always associated with
generation of electricity. The TSD and other information confirm our
understanding.
---------------------------------------------------------------------------
\5\ See, e.g., EPA-HQ-OAR-2009-0234-20269, -20275, and -20303.
---------------------------------------------------------------------------
For determining the appropriate time after generation to define the
end of startup (i.e., the time when the numerical standards apply), the
EPA conducted an analysis of continuous emission monitor system (CEMS)
data for NOX and SO2 from EGUs to determine the
range of times after initial generation of electricity or thermal
energy that EGUs typically take to engage and operate all of their
APCDs. The EPA determined the best performing 12 percent of EGUs by
identifying those EGUs that were able to engage their APCDs most
quickly after the initial generation of electricity or thermal energy
and averaged that time to determine the end of the startup period when
the numeric standards would become applicable. Specifically, we
evaluated the average startup period for the best performing 12 percent
of EGUs for which the EPA has the relevant data (i.e., those with the
relevant NOX and/or SO2 controls). We
[[Page 68780]]
used 12 percent of the sources with the relevant controls because the
metric upon which the end of startup is based depends on the presence
of the relevant controls, not on the actual NOX and
SO2 emissions. Thus, sources without the relevant controls
cannot be compared against sources with the relevant controls for
purposes of defining the end of startup in this final rule. CAA section
112(d)(3)(A) directs the EPA to establish MACT floor standards based on
the performance on the best performing 12 percent of sources for which
the Administrator has data, and, in this case, the agency does not have
relevant data from all sources in the category. For this reason, it is
reasonable to establish the work practice based on 12 percent of the
sources with the relevant data (i.e., those EGUs with the relevant
NOX or SO2 controls).
We used this approach to determine the end of startup because it is
reasonable to expect the EGUs that are able to most quickly and
efficiently engage their controls after the generation of electricity
to be the best performing sources and to have the lowest HAP emissions
during and directly after the startup period, and because we are
confident that EGUs will be able to accurately measure HAP emissions
with CEMS at this time. The requirement to maximize the use of clean
fuels (with inherently low HAP emissions) during the startup period
ensures that HAP emissions are minimized during that time. Because EGUs
subject to Acid Rain Program requirements are required to submit
continuous NOX and SO2 data to the EPA, the
agency believes it has data on all startup events from those EGUs
subject to that program, which comprise nearly all EGUs subject to this
rule, for over a decade. Thus, we believe we have a full data set from
which to determine the end of the startup period for the best
performing 12 percent of sources for which we have the relevant
data.\6\ We maintain it is reasonable to use the CAA section 112(d)(3)
metric for establishing MACT floors for existing sources as a starting
point for determining the appropriate work practice when presented with
such comprehensive data. See CAA 112(h)(1) (directing the agency to
establish a work practice standard ``which in the Administrator's
judgment is consistent with the provisions of subsection (d) or (f) of
this section.'').
---------------------------------------------------------------------------
\6\ We note that these data are not reliable for quantifying
emissions for this analysis but, rather, the data allow us to
evaluate when controls are turned on for the purpose of determining
when startup ends.
---------------------------------------------------------------------------
For shutdown periods, the EPA determined that sources could cease
adding coal or oil to the EGU prior to shutting down the APCDs. We
determined that sources able to run their control devices even after
coal or oil is added to the EGU for the last time before shutdown were
the best performing sources because HAP emissions would be minimized as
the EGU combusts the remaining coal or oil in the boiler.
The final work practice standard, when applied across the industry,
will greatly reduce HAP emissions during startup periods and shutdown
periods. The requirement to maximize clean fuel use throughout the
startup period will significantly limit HAP emissions because of the
inherently low HAP emissions associated with the clean fuels identified
in 40 CFR 63.10042.\7\ In addition, the requirement to engage and
operate PM controls as expeditiously as possible and within 1 hour of
coal, residual oil, or solid oil-derived fuel combustion will limit HAP
emissions that are particulate in nature throughout the remainder of
the startup period. We believe that application of this work practice
will lead to HAP emissions during startup periods and shutdown periods
that are comparable to, and potentially lower than, those levels
authorized during normal operations when averaged over the entire
startup and/or shutdown period. During the 8-year review required under
CAA section 112(d)(6), the agency intends to further assess HAP
emissions during startup and shutdown based on data collected from
sources complying with the final rule, though we recognize that
prospectively our ability to establish numerical standards during
startup periods and shutdown periods will depend, at least in part, on
the further development of testing methodologies that will allow the
agency to accurately measure emissions during those periods with an
acceptable level of certainty.
---------------------------------------------------------------------------
\7\ Natural gas is one of the clean fuels identified in this
final rule and the agency determined in 2000 that it was neither
appropriate nor necessary to regulate natural gas-fired EGUs because
the impacts from HAP emissions from such units are ``negligible.''
See ``Regulatory Finding on the Emissions of Hazardous Air
Pollutants from Electric Utility Steam Generating Units,'' 65 FR
79825, 79831 (December 20, 2000).
---------------------------------------------------------------------------
The specific provisions of the alternative startup and shutdown
requirements and our rationales for those provisions are discussed in
more detail below and in the RTC document in Docket ID No. EPA-HQ-OAR-
2009-0234.
1. Definitions
In the November 2012 reconsideration proposal, we proposed
revisions to the definitions of startup and shutdown contained in the
final MATS rule and set forth in 40 CFR 63.10042, after receiving
petitions for reconsideration of the startup and shutdown provisions in
the final MATS rule. Petitioners asserted, among other things, that the
final rule's definitions of startup and shutdown were not sufficiently
clear, should accommodate operation of cogeneration units, and did not
accurately reflect startup conditions for all affected units. We
received additional comments on these issues during the public comment
periods. For more discussion of the petitions for reconsideration and
the comments on the definitions in the final rule, see the RTC in
Docket ID No. EPA-HQ-OAR-2009-0234.
As a result of comments received on the November 2012 proposal and
the June 2013 reopening of the public comment period, we have further
revised the proposed definitions as follows.
a. Startup. The definition of startup in the November 2012
reconsideration proposed rule was similar to the definition the EPA
finalized in MATS in February 2012. In this final reconsideration rule,
we have maintained the final MATS definition of startup and, in
addition, are finalizing an alternative definition of startup based on
the November 2012 proposal and the analysis in the startup and shutdown
TSD. Sources may choose to use either definition of startup when
complying with the startup and shutdown requirements. We are finalizing
both definitions because we believe that they both meet the
requirements of CAA section 112 to reduce HAP emissions during this
time period and will provide operators with flexibility, even though we
question the ability to accurately measure HAP emissions at the start
of electricity generation. A discussion of the comments and analyses
that led to inclusion of the alternative startup definition is provided
below.
In the November 2012 reconsideration proposal, the EPA proposed
that startup be defined as the period in which operation of an EGU is
initiated for any purpose. The proposed definition indicated that
startup begins with either the first-ever firing of fuel in an EGU for
the purpose of producing electricity or useful thermal energy (such as
heat or steam) for industrial, commercial, heating, or cooling purposes
or the firing of fuel in an EGU for any purpose after a shutdown event.
The proposed
[[Page 68781]]
definition indicated that startup ended when the EGU generates
electricity that is sold or used for any other purpose (including on
site use), or the EGU makes useful thermal energy (such as heat or
steam) for industrial, commercial, heating, or cooling purposes,
whichever is earlier. The agency received comments stating that the
general approach provided in the proposed definition of ``startup''
(particularly the end of startup) was directionally correct but did not
allow sufficient time for the APCDs to become effective and, thus, the
industry was concerned that some EGUs would not be able to achieve the
MATS emission limits finalized in the February 2012 rule at the end of
startup as defined in the final MATS rule. The comments further stated
the opinion that startup did not end with first generation of
electricity or production of steam as the EPA had proposed. Instead,
some comments suggested that the defined end of startup should be
changed to be 4 hours after 25-percent load is first reached or 12
hours after first electricity generation, whichever occurs first. Some
comments stated that even longer time periods were necessary for
certain types of EGUs, that different startup periods should be defined
for different types of EGUs, and that additional consideration should
be given to a wider variety of APCDs. Other comments maintained that
the definition in the final MATS rule was appropriate and indicated
that any extension of time during which the EGUs were not subject to
the final rule's emission limits was not in accordance with CAA section
112.
The EPA disagrees with the commenters to the extent they maintain
that a work practice is required after emissions can be accurately
measured or that the agency is bound to the time contained in the final
rule where, as here, we conclude that the HAP measurement methodologies
are not capable of accurately measuring HAP emissions during the
defined startup period. The EPA did, however, conduct an additional
technical analysis after its initial review of the comments and in June
2013 published a document reopening the public comment period. The
document specifically requested comment on the additional technical
analysis the EPA had conducted in response to comments received
concerning the end of startup. See ``Assessment of startup period at
coal-fired electric generating units'' (Docket ID No. EPA-HQ-OAR-2009-
0234-20378). In the analysis, the EPA examined several indicators that
allowed the agency to assess the time required to engage APCDs at
affected EGUs. Using these indicators, we found no significant
difference in performance related to startup between the different
groups or types of EGUs assessed in the analysis (e.g., circulating
fluidized bed (CFB), stoker, subcritical, supercritical). We further
indicated that the results of our analysis supported defining the end
of startup at coal- and oil-fired EGUs as occurring at the time to
achieve 25 percent of the EGU's nameplate generating capacity
(megawatts, MW) plus 3 hours, or the start of electricity generation
plus 6 hours, whichever comes first.
The EPA has reviewed all of the comments received on the proposed
definition of startup in response to these two opportunities for public
comment and has revised the June 2013 analysis. Based on this review,
we are finalizing a revised definition of ``startup'' that uses the
approach outlined in the June 2013 assessment with revisions as
discussed below.
Defining the End of ``Startup''
The June 2013 analysis suggested a potential end time for startup
of 6 hours after the start of electricity generation or 3 hours after a
coal- or oil-fired EGU reaches 25 percent of nameplate capacity,
whichever occurs first. In other words, 6 hours after the start of
generation or 3 hours after reaching electricity generation equal to 25
percent of nameplate capacity, whichever comes first, an EGU would have
to start monitoring and reporting its emissions for the purpose of
complying with the numeric emissions standards contained in MATS.
The EPA took this approach because we determined that flue gas
conditions will be adequate to accurately measure HAP emissions with
CEMS 4 hours after the generation of electricity. The approach
evaluated the time for all APCDs to be functioning because we
determined that stack conditions will be stable at this point. The
analysis was based on our review of hourly SO2 and
NOX emissions from CEMS installations from nearly 9,500
distinct startup events at more than 400 coal-fired EGUs, including CFB
boilers, and subcritical and supercritical pulverized coal boilers
equipped with SO2 APCDs (e.g., wet or dry flue gas
desulfurization (FGD)) and/or NOX APCDs (e.g., selective
catalytic reduction (SCR)). The EPA analyzed hourly SO2 and
NOX emissions primarily because changes in SO2
and NOX emissions are reasonable indicators of when APCDs
are operational and stack conditions will be sufficiently stable to
allow for accurate measurement of HAP emissions with CEMS. We also note
that SO2 emissions are a surrogate for acid gases (e.g.,
hydrogen chloride); SO2 APCDs can be used for co-benefit
mercury (Hg) control; and NOX SCR APCDs may increase the
oxidation of Hg, influencing the effectiveness of Hg controls.\8\ The
goal of the analysis was to identify the approximate time it took, on
average, to initiate operation of SO2 and NOX
APCDs because it was those controls (e.g., scrubbers and SCR) that
industry commenters stated required additional time to engage after the
start of generation of electricity or useful thermal energy. The goal
in conducting the analysis was not to determine the time it took for
APCDs at all EGUs to become fully operational, but instead to determine
the average time for the engagement of APCD to determine a reasonable
end of startup.
---------------------------------------------------------------------------
\8\ The EPA did not include hourly PM data in this analysis
because PM CEMS data are not available and PM CEMS have not yet been
certified to accurately measure during periods of startup and
periods of shutdown as defined in this final rule.
---------------------------------------------------------------------------
The EPA received detailed comments on the June 2013 analysis and
the proposed rule. Although commenters' opinions varied, the EPA
identified three distinct groups of comments. The first group agreed
with the EPA's approach to define a time limit following the start of
generation, but many commenters suggested that more time was necessary
to safely and/or fully engage APCDs. The second group commented that
CAA section 112 requires the EPA to establish standards based on the
average of the best performing 12 percent of EGUs, not the average of
the fleet. The third group disagreed with the EPA's approach, stating
that many APCDs could not be fully functional within the time limits
specified by the EPA, and citing the need for greater flexibility.
The EPA evaluated the information provided by commenters and
considered the different approaches to define the end of startup.\9\
After careful consideration and in light of issues raised in comments
and data provided, the EPA has revised its initial approach for
determining the end of startup in
[[Page 68782]]
several respects. First, in the June 2013 analysis, we did not attempt
to identify the EGUs that were the best performing sources, but instead
simply looked at a category-wide average time for engagement of APCDs.
As certain commenters noted, the category-wide average may not satisfy
the CAA section 112(h) requirement that the EPA establish work practice
standards ``which in the Administrator's judgment [are] consistent with
the provisions of subsections (d) or (f) of this section [112].'' To
more appropriately track this statutory directive, the EPA revised the
analysis and identified the EGUs that were able to most quickly engage
their APCDs because we determined that the best performing EGUs for
purposes of defining the end of startup are those that are able to most
efficiently engage their controls after the start of electricity
generation. The EPA then averaged the time it took for such EGUs to
bring their APCDs on line to determine a reasonable time after
generation of electricity to define the end of startup. The EPA chose
this approach in the final rule because we believe it most closely
follows the requirements of CAA section 112.
---------------------------------------------------------------------------
\9\ It is important to remember that the hour at which startup
ends is the hour at which reporting for the purpose of determining
compliance begins. Therefore, EGUs must collect and report emissions
and heat input or generation data following the end of startup.
These data are used in calculating whether an EGU is in compliance
with the 30-day average emission limits. MATS does not mandate that
all APCDs must be fully operational at the end of startup (nor does
it mandate that emissions during any given hour during this period
must be below the 30-day average emission limits); rather, MATS
mandates only that sources comply with the MATS emission standards
at that time.
---------------------------------------------------------------------------
The EPA analysis of startup events at coal-fired EGUs indicates
that the best performing EGUs can, on average, initiate operation of
their SO2 and NOX APCDs within 4 hours following
the start of generation (see Technical Support Document (TSD) titled
``Assessment of startup period at coal-fired electric generating
units--Revised'' in Docket ID No. EPA-HQ-OAR-2009-0234). In addition,
the Agency is confident that stack conditions at this time are
conducive for accurate measurements of HAP emissions using CEMS. For
these reason, and because SO2 can be used as a surrogate for
the control of acid gases and SO2 and NOX APCDs
can impact the control of Hg emissions, and because we believe based on
comments and other information that SO2 and NOX
controls are generally the last APCDs to be engaged, the EPA has
determined that the end of startup should be defined as the end of the
4th hour following the start of generation of electricity or useful
thermal energy. The agency has also determined that it is not necessary
to include any additional variability because the agency believes it
has information on all of the startup events from the EGUs with the
relevant data so startup time variability is fully represented in the
available data.
b. Shutdown. The EPA is maintaining the definition of ``shutdown''
proposed in the November 2012 action, and further requiring that all
APCDs must be operated as long as coal, residual oil, or solid oil-
derived fuel is being fired in the EGU and as long thereafter as
possible, considering safety and system integrity.
The RTC contains a summary of the comments received on this topic
and the EPA's response to those comments.
2. Work Practice Standards and Clean Fuels
The final work practice for startup periods requires EGUs to
initiate startup using clean fuels and to combust only clean fuels
until primary fuel (e.g., coal, residual oil, or solid oil-derived
fuel) is fed into the EGU, at which time the EGU must engage and
operate its PM controls as soon as possible and no later than 1 hour
thereafter. After engagement of PM controls, EGUs are required to
maintain maximum clean fuel use until the end of startup (i.e., 4 hours
after the start of generation of electricity or useful thermal energy).
The maximization of clean fuel use after addition of primary fuel to
the EGU assures that the least amount of HAP possible will be emitted
from the units during the startup period. The final rule also includes
more fuels on the list of clean fuels that may be combusted during
startup periods and shutdown periods, as discussed below.
The EPA is finalizing a requirement in the work practice that PM
controls be engaged and operated within 1 hour of coal, residual oil,
or solid oil-derived fuel being fired. In the November 2012 proposal,
the EPA proposed to require that once an EGU starts firing coal,
residual oil, or solid oil-derived fuel, all of the applicable control
devices had to be engaged, with certain listed exceptions. PM-specific
control devices were not included in that list of excepted controls
because the EPA believed that PM controls on EGUs could be engaged
(i.e., operational) at the best performing EGUs at the time the primary
fuel (i.e., coal, residual oil, or solid oil-derived fuel) is fired.
The EPA has reviewed both the record and the comments received, and we
have determined that the EGUs that are able to engage PM controls
(through either use of PM-specific controls (e.g., ESP, FF) or wet FGD
scrubber system alone or in conjunction with PM controls) within 1 hour
following the initiation of firing of coal, residual oil, or solid oil-
derived fuel are the best performing sources for purposes of minimizing
particulate HAP emissions during startup periods.\10\ Therefore, we are
finalizing a requirement that an owner/operator must engage and operate
the PM controls within 1 hour of first firing of coal, residual oil, or
solid oil-derived fuel.
---------------------------------------------------------------------------
\10\ Docket ID Nos. EPA-HQ-OAR-2009-0234-20269, EPA-HQ-OAR-2009-
0234-20275.
---------------------------------------------------------------------------
Moreover, in order to demonstrate an EGU's capacity to maximize the
use of clean fuels during startup periods and its ability to bring PM
control devices online in an expeditious manner following first firing
of coal, residual oil, or solid oil-derived fuel, the rule now requires
EGU owners or operators to determine and report each EGU's maximum
storage capacity for clean fuels and maximum capacity for heat input
while combusting clean fuels alone. The rule also requires EGU owners
or operators to identify, record, and report semiannually each instance
of startup or shutdown, specifying the dates and times that clean fuel
use begins and ends; the dates and times that primary (i.e., coal or
oil) fuel use starts or ends; and the hourly clean fuel usage, heat
input, and electrical output.
In addition, for those non-liquid oil-fired EGUs not using PM CEMS,
HAP metals CEMS, or PM continuous parameter monitoring system (CPMS) as
a compliance determination method or not meeting low emitting EGU (LEE)
status \11\ for PM or non-mercury HAP metals emissions or those liquid
oil-fired EGUs not using PM CEMS or PM CPMS as a compliance
determination method or not meeting LEE status for PM or HAP metals
emissions, parametric monitoring data will be required to help show PM
control device effectiveness upon first use of coal, residual oil, or
solid oil-derived fuel. This type of data is not required from EGUs
using PM CEMS, HAP metals CEMS, or PM CPMS, as those instruments are
already required to provide these data during startup periods; those
data are suitable for assessing how soon and how well PM control
devices are operating. Likewise, once EGUs meet the LEE status for PM
or non-mercury HAP metals emissions for non-liquid oil-fired EGUs (or
HAP metals emissions for liquid oil-fired EGUs), they will no longer
need to supply additional information regarding PM control device
operation during startup periods, for it is reasonable to expect their
PM control devices to be properly sized and operated in order to
demonstrate consistent operation at less than 50 percent of the
emissions limit over a 3-year period. It is also reasonable to expect
that the information recorded and calculated during startup periods and
shutdown periods from LEE-eligible EGUs will show better emissions
performance
[[Page 68783]]
when compared to similar information obtained from EGUs without LEE
status.
---------------------------------------------------------------------------
\11\ See 40 CFR 63.10005(h).
---------------------------------------------------------------------------
Upon initiation of first use of coal, residual oil, or solid oil-
derived fuel, EGUs not using PM CEMS or PM CPMS as a compliance
determination method or not meeting LEE status for PM or non-mercury
HAP metals emissions for non-liquid oil-fired EGUs (or HAP metals
emissions for liquid oil-fired EGUs) are also required to record hourly
and report semi-annually the pre- and post-PM control device flow rates
and temperatures, as well as fan amps. Moreover, the PM control device-
specific parameters are required to be recorded hourly and reported
semi-annually. The EGUs with ESPs are required to record the number of
fields in service and the secondary current and voltage for each hour
of startup and shutdown. The EGUs with FFs are required to record the
number of compartments in service and the differential pressure across
the baghouse. Finally, the EGUs with wet scrubbers that are necessary
for filterable PM emission control will record scrubber liquid-to-flue
gas ratios and scrubber liquid differential pressure for each hour of
startup and shutdown.
Given that we do not have much information concerning continuous PM
emissions or PM emission control devices during periods of startup, the
final rule requires owners or operators of EGUs that choose to use
definition (2) of ``startup'' contained in 40 CFR 63.10042 to provide a
report prepared by an independent professional engineer that describes
the EGU, PM emissions, and PM emissions control devices both as
designed and in their current form. This information will show how each
EGU is able, or has been modified, to meet the requirements of this
rule. In addition, the information will specify the time needed to
engage PM emission control devices from initial fuel combustion in the
EGU; the effectiveness of each PM emission control device, both upon
control device startup and at normal operation; the PM emission rate;
and the uncontrolled PM emissions rate. The report will be submitted as
part of the EGU's Notification of Compliance Status, and the
information contained in the report will aid us in determining whether
or not additional work practice requirements may be needed during
startup periods to minimize HAP emissions.
Finally, the EPA acknowledges the comments asserting safety issues
that must be considered during startup of PM controls (e.g., carbon
monoxide buildup, fabric blinding). We believe that almost all EGUs
will be able to alter their source through any number of means,
including increasing clean fuel capacity and modifying APCD operation,
and comply with the final work practice requirements; however, we
recognize that there may be rare occasions that preclude a viable
compliance option consistent with the final rule. Therefore, we are
finalizing that an owner/operator may submit to the Administrator a
request for an EGU-specific case-by-case emission standard consistent
with 40 CFR 63.6(g). Such a request requires notice-and-comment
rulemaking. Approval or disapproval authority for this type of request
is delegated to the Assistant Administrator of the Office of Air and
Radiation, and, for purposes of this rule, will be delegated no
further.\12\ However, the EPA will only consider requests that provide
evidence of a documented manufacturer-identified safety issue and can
provide proof that the PM control device is adequately designed and
sized to meet the final PM emission limit. As identified in 40 CFR
63.10011(g)(4), in its request for the case-by-case determination, the
owner/operator must provide, among other materials, documentation that:
(1) The EGU is using clean fuels to the maximum extent possible to
bring the EGU and PM control device up to the temperature necessary to
alleviate or prevent the identified safety issues prior to the
combustion of primary fuel in the EGU, (2) the EGU has explicitly
followed the manufacturer's procedures to alleviate or prevent the
identified safety issue, (3) the source provides details of the
manufacturer's statement of concern, and (4) the source provides
evidence that the PM control device is adequately designed and sized to
meet the final PM emission limit. In addition, the source will have to
indicate the other measures it will take to limit HAP emissions during
startup periods and shutdown periods to ensure a control level
consistent with the final work practice requirements. In order to
ensure compliance with the work practice standards during startup
periods, EGU owners or operators who request an alternative non-opacity
emission standard shall comply with definition (1) of startup contained
in 40 CFR 63.10042 (i.e., the definition contained in the final rule
promulgated on February 12, 2012) \13\ until the final alternative non-
opacity emission standard is promulgated in the Federal Register.
---------------------------------------------------------------------------
\12\ See Delegation 7-121 and Delegation of Authority under the
Clean Air Act to Approve Alternatives to Test Methods and Procedures
in Parts 60, 61, 63, and 65, from Gina McCarthy to Stephen Page,
September 30, 2011, in docket ID EPA-HQ-OAR-2009-0234.
\13\ See 77 FR 9303; February 16, 2012.
---------------------------------------------------------------------------
We also proposed several revisions to the work practice standards
issued in the final MATS rule in response to petitions on the final
rule. Petitioners asserted that the final rule's work practice
standards should include additional fuels as ``clean fuels'' and
recognize operating limitations of certain EGU types and APCDs.
Specifically, petitioners contended that the list of clean fuels
required for use during startup in order to minimize emissions should
include, among others, synthetic natural gas, synthesis gas (syngas),
biodiesel, and ultra-low sulfur diesel (ULSD). The EPA has also been
informed that propane is used to startup some EGUs.
In this final action, we are adding certain synthetic natural gas
(that meets the specification necessary for that gas to be transported
on a Federal Energy Regulatory Commission (FERC) regulated pipeline),
synthesis gas that has been processed through a gas clean-up train such
that it is suitable for use in the system's combustion turbine, and
ULSD to the list of clean fuels. In addition, the EPA does see merit,
as suggested by some commenters, of further broadening the definition
of ``clean fuels.'' After reviewing other rules that use or require
clean fuels, we believe that inclusion of those fuels meeting the
requirements of 40 CFR Part 80, subpart I (``Subpart I--Motor Vehicle
Diesel Fuel; Nonroad, Locomotive, and Marine Diesel Fuel; and ECA
Marine Fuel'') is appropriate. Specifically, the definitions and
provisions of 40 CFR 80.2, 80.501, 80.510, and 80.520 address sulfur
content restrictions relating to distillate, diesel (including ULSD),
and biodiesel fuels. The EPA believes that requiring use of clean
fuels, including those we are adding in this final rule, for EGUs will
significantly limit the HAP emissions from these sources during startup
periods and shutdown periods. For example, information provided to the
EPA on another rulemaking (found in Docket ID No. EPA-HQ-OAR-2008-0708-
1459) \14\ showed that the use of ULSD will significantly reduce
emissions of air toxics, including metallic HAP (e.g., nickel, zinc,
lead (Pb)) compared to the use of ``regular'' diesel. The EPA also
believes that combustion of the other 40 CFR Part 80, subpart I, fuels
meeting the subject definitions will cause significantly lower HAP
emissions than
[[Page 68784]]
coal and residual oil, and, as stated above, EGUs must use clean fuels
to the maximum extent possible during startup periods and shutdown
periods.
---------------------------------------------------------------------------
\14\ Email and attachments from Paul Miller, NESCAUM, to Melanie
King, EPA. NESCAUM's RICE NESHAP comments. October 11, 2012, also
found in Docket ID No. EPA-HQ-OAR-2009-0234.
---------------------------------------------------------------------------
We are maintaining the work practice requirement in the final MATS
that requires EGU source owners and operators, when firing coal,
residual oil, or solid oil-derived fuel in the EGU during startup or
shutdown, to vent emissions to the main stack(s) and operate all
control devices necessary to meet all operating and emissions standards
that are applicable to the source pursuant to other CAA or state
requirements. In addition, any partial (fractional) operating hour that
may occur at the beginning of a startup period or at the end of a
shutdown period is to be flagged in reports as an hour of startup or
shutdown.
For more discussion of each of these issues, please refer to the
RTC, the TSD, and the memo ``Startup and shutdown provisions'' (Docket
ID No. EPA-HQ-OAR-2009-0234-20224) in Docket ID No. EPA-HQ-OAR-2009-
0234.
3. Treatment of IGCC EGU Syngas
The EPA is finalizing both the use of flares and the use of duct
burners for integrated gasification combined cycle (IGCC) units to
handle syngas not combusted in the turbine during startup periods and
shutdown periods.
An IGCC EGU includes both a gasification unit and a combustion unit
and syngas is generated in the gasifier for the primary purpose of
being combusted in the associated combustion turbine. The EPA
understands that, in some cases, the gasified fuel can be used for
other purposes such as the production of chemicals (e.g., fertilizers,
methanol) if the facility has been designed to do so. During the
startup periods and shutdown periods, some or all of the syngas
produced for the purpose of power production may not be combusted in
the turbine. We proposed two options for IGCC EGUs for handling syngas
not fired in the combustion turbine: (1) Syngas must be flared, not
vented, or (2) syngas must be routed to duct burners, which may need to
be installed, and the flue gas from the duct burners must be routed to
the heat recovery steam generator. We solicited comments on the need to
flare the unfired syngas, if it is more appropriate to require routing
of the unfired syngas back into the system for all IGCC EGUs, and on
the costs of adding duct burners, should they be required.
Industry commenters stated that it is important that flaring remain
an option for routine startups and shutdowns for safety reasons and as
a viable option for non-routine events such as EGU ``trips'' when the
combustion turbine cannot combust syngas. Commenters noted that the
flaring option is especially critical as the re-routing option can only
be used by IGCC EGUs under limited circumstances as the syngas may lack
sufficient pressure for re-injection and gasifiers are often once-
through systems that do not support re-routing of the syngas.
Commenters indicated that the actual flaring step of an IGCC startup is
relatively short and ordinarily lasts less than 2 hours and that only
clean syngas is flared during a routine startup.
The EPA is finalizing both options, use of flaring or duct burners,
for handling of syngas not combusted in the turbine during startup
periods and shutdown periods.\15\ The EPA believes that the controls
are comparable and that allowing the option will provide flexibility to
owners/operators of IGCC EGUs to choose either of the options subject
to operational constraints at their IGCC EGUs. The EPA believes it
appropriate to cover gasifier syngas during startup periods and
shutdown periods of the combustion turbine portion of the IGCC because
the units are inextricably linked and the unused gas would not be
generated but for the startup of the combustion portion of the IGCC
unit. The EPA is requiring the use of either flares or duct burners to
combust unused syngas during startup periods and shutdown periods.
---------------------------------------------------------------------------
\15\ IGCC units that are also designed to co-produce chemicals
or other products using syngas may also choose to use the unburned
syngas in that process.
---------------------------------------------------------------------------
4. Common Stacks
The final MATS rule at 40 CFR 63.10010(a)(1), (2), and (3) required
owners or operators of EGUs with common stacks to either monitor the
EGUs separately or monitor the common stack and assign the same
emissions value to each EGU. No specific requirements concerning
monitoring during startup periods or shutdown periods were given
because the EPA believed the provisions as finalized were sufficient.
Consistent with the monitoring provisions in the final rule, owners or
operators of EGUs with common stacks are required to monitor and report
emissions for compliance purposes at all times when any EGU using a
common stack is operating in a non-startup/shutdown mode, even if
another EGU using that common stack is in startup/shutdown mode. 40 CFR
63.10005(a)(2)(iii) reinforces and clarifies this requirement. Also,
consistent with the final rule, work practice standards, rather than
numeric emissions limits, apply during startup periods or shutdown
periods, but only to EGUs in startup or shutdown mode. Today's
reconsidered rule maintains the approach of the final rule. Owners or
operators of EGUs with common stacks may either monitor each EGU
separately upstream of the common stack or from the common stack.
Monitoring must be operational (except for periods of monitor
malfunction and during required quality assurance (QA) and maintenance
activities) at all times that any fuel is being combusted, and
compliance with numeric emission limits is required except for periods
when all EGUs sharing the common stack are in startup or shutdown mode.
Should an owner or operator choose to monitor the common stack, then
emissions obtained from the monitoring will be applied to each EGU that
shares the stack. This approach remains consistent with the final rule,
and is not expected to be problematic emissions-wise for any EGU using
a common stack, because the EGUs in startup periods or shutdown periods
are required to use clean fuels and comply with the other work practice
requirements. In addition, the EGUs sharing the common stack and
operating in a mode other than startup or shutdown are required to
operate such that they meet their emissions limits. We believe, based
on evaluation of source compliance for many years, that sources
generally operate in a manner to ensure a compliance margin to avoid
potential exceedances.\16\ Thus, we maintain the monitoring options
available in the final rule are sufficient to address concerns from
commenters.
---------------------------------------------------------------------------
\16\ ``. . . (S)ources do not design to meet a standard, but
rather to meet a level comfortably lower. They do so in order to
provide a compliance margin on those days where emissions rise due
to inherent and uncontrollable variability . . .'' See 77 FR 42386;
July 18, 2012.
---------------------------------------------------------------------------
As discussed below, the EPA is also establishing a default
electrical load of 5 percent of the maximum sustainable electrical load
of the EGU. This default value will be allowed to be used during
periods of startup or periods of shutdown when the electrical load is
zero. For EGUs sharing a common stack with just one common monitoring
system, this default value will be available only when the electrical
load is zero for an EGU sharing the common stack that is in a period of
startup or shutdown. As soon as a non-zero electrical load is produced,
that non-zero load must be used in electrical output-based emission
rate calculations for each EGU in a startup or shutdown period, even if
the load is less than 5 percent of capacity. Note that the electrical
load of all EGUs in operation and sharing a common stack with just
[[Page 68785]]
one common monitoring system are to be summed when electrical output-
based emission rate calculations are made.
Section 1.2.5 of the RTC contains both a summary of comments
received on this topic and the EPA's response to those comments.
5. Diluent Cap
Apart from allowing use of a diluent cap when calculating Hg
emissions during startup periods or shutdown periods, the final rule
contained no allowance for use of a diluent cap. The November 2012
proposal sought comment on the need for a diluent cap for other HAP
emissions during startup periods and shutdown periods. Use of a diluent
cap can be important during startup periods and shutdown periods
because CEMS values can approach infinity because the denominator in
the calculations for CEMS values can approach zero during those
periods. Moreover, use of a diluent cap becomes a common stack issue
when one or more of the EGUs is in a startup or shutdown mode and just
one monitoring instrument is used in the stack.
The EPA considered each comment and decided to allow use of default
carbon dioxide (CO2) or oxygen (O2) values as
identified in Section 3.3.4.1 of Appendix F of 40 CFR part 75, but only
for startup periods or shutdown periods when CO2 values are
below or O2 values are above default values for use in all
pollutant calculations. For non-IGCC EGUs, the default CO2
value is 5 percent and the default O2 value is 14 percent.
This means that when CEMS CO2 measurements are below 5
percent, EGU owners or operators are allowed to use 5 percent
CO2 in their calculations. Because the startup analysis
showed that CEMS CO2 measurements exceeded default values
within 2 hours of generation, the EPA does not expect to find default
values being used when startup periods end. Likewise, when CEMS
O2 measurements are larger than 14 percent, EGU owners or
operators will be able to use 14-percent O2 in their
calculations. IGCC EGUs will be allowed to use 1 percent as a default
CO2 value or 19 percent as a default O2 value. As
mentioned earlier, default diluent gas values will be allowed for use
in calculations for startup periods or shutdown periods when
CO2 CEMS values are below or O2 CEMS values are
above default values. The rule requires EGU owners or operators to use
actual CO2 or O2 CEMS values for all other
operating periods. Although the EPA has no specific data or information
concerning emissions during transient events outside startup or
shutdown periods, the EPA expects the short duration of these transient
events outside startup or shutdown periods that could cause
CO2 or O2 CEMS to be below (or above) default
values to have little, if any, impact on the 30-boiler operating day
rolling averages.
The rule retains the requirement for EGU owners or operators to
report instrumental CEMS, PM CPMS, and sorbent trap information, as
well as flow rate information during startup periods or shutdown
periods. Such information may prove useful in assessing potential
emissions or operational limits in future rulemaking activities.
Finally, the rule requires EGU owners or operators to identify each
hour of startup or shutdown in which a diluent cap value is used.
Section 5.1 of the RTC contains both a summary of comments received
on this topic and the EPA's response.
6. Default Electrical Output
The final rule provided no allowance regarding default electrical
output. The November 2012 proposal sought comment on the need for a
default electrical output for those owners or operators who choose to
comply with a mass per electrical output standard. Use of a default
electrical output cap can be important during startup periods and
shutdown periods because the calculated mass per electrical output
values can approach infinity when the electrical output is zero during
those periods.
Upon consideration of the comments, the rule will provide a default
electrical load value that EGU owners or operators will be allowed to
use during startup periods or shutdown periods to calculate emissions
rates for an EGU, as long as the electrical load for the EGU is zero.
Once the EGU begins generating electricity, the source must use the
actual electrical output in compliance calculations, even if the output
is below the 5 percent default value. Moreover, use of a default
electrical load is not allowed during periods other than startup or
shutdown. As suggested by one commenter, the default electrical load
will be equivalent to 5 percent of the maximum sustainable electrical
output in megawatts of an EGU, as defined in section 6.5.2.1(a)(1) of
appendix A to part 75, and included in an EGU's Part 75 electronic
monitoring plan. This maximum sustainable load is either the nameplate
capacity of the EGU or the highest electrical load observed in at least
four representative quarters of EGU operation. When used in a common
stack application, the default electrical load is 5 percent of the
combined maximum sustainable electrical load of the EGUs that are in
startup or shutdown mode during an hour in which the electrical load is
zero. The default electrical load is allowed to be used in electrical
output-based emission rate calculations (either pounds per megawatt-
hour (lb/MWh) or pounds per gigawatt-hour (lb/GWh)) for any hour in
which the actual electrical load for a single EGU or for every EGU
venting to a common stack is zero. The EPA considered, but decided
against, requiring measurement of thermal heat output and conversion
back into equivalent electrical output; instead, the EPA decided to use
a simpler approach based on already-existing requirements of the Acid
Rain Program that we believe are most appropriate considering CAA
section 112 and in light of the available data. Finally, the rule
requires EGU owners or operators to identify each hour of startup or
shutdown in which a default electrical load value is used.
Section 5.2 of the RTC contains both a summary of comments received
on this topic and the EPA's response to significant comments.
7. Use of Sorbent Traps
The final rule required continuous Hg data collection using sorbent
traps or Hg CEMS under all process operating conditions, including, but
not limited to, startup periods and shutdown periods, over the entire
30 boiler operating day LEE qualification testing period. For sorbent
traps, the EPA allowed use of redundant backup sorbent trap monitoring
systems during startup periods and shutdown periods; and required
operation of sorbent trap monitoring systems and collection of Hg data
at all times EGUs operate, but did not allow use of Hg data collected
during startup or shutdown periods to be included in compliance
calculations.
After consideration of comments received on Hg monitoring during
startup or shutdown periods using sorbent trap monitoring systems, the
EPA decided that the final reconsidered rule will contain three
alternative approaches for measuring Hg emissions during startup
periods or shutdown periods. In the first approach, EGU owners or
operators will continue to be able to use Hg CEMS for measuring Hg
emissions.
The second approach relies on at least two separate sorbent
monitoring systems. Although the rule has no prohibition against an EGU
owner or operator using one sorbent trap monitoring system for
compliance purposes during periods other than startup or shutdown and
one (or more) sorbent trap monitoring systems for
[[Page 68786]]
startup periods or shutdown periods through the use of a non-redundant
backup system (per section 2.2.2 of Appendix A to subpart UUUUU of Part
63), it will be clarified that two separate sorbent monitoring systems
are allowed. Reliance on this second approach would address one
commenter's concern that Hg compliance data could not be separated from
Hg data collected during startup and/or shutdown periods when
demonstrating compliance with numerical standards based on a sorbent
trap system. When an EGU with at least two such systems (one for
startup periods or shutdown periods and the other for all other
periods) entered into a startup or shutdown period, the EGU owner or
operator could switch monitoring systems either manually or
automatically. As part of an EGU owner or operator's rubric for
choosing which Hg measurement approach to use, the EGU owner or
operator should take into account that any process operating hour for
which quality assured Hg concentration data are not obtained is counted
as an hour of monitoring system downtime, per section 1.4 of Appendix A
to subpart UUUUU of Part 63. Therefore, if an EGU owner or operator
believes change-out of sorbent monitoring traps may take too long,
other approaches may be more suitable. An EGU owner or operator should
carefully consider all costs--not only of sorbent tubes, analyses, and
associated labor, but also of non-compliance due to data gaps, when
determining whether this approach is appropriate.
The third approach, relying on just one sorbent trap monitoring
system for all periods of operation (startup, shutdown, and normal),
will be identified in the rule as a viable option for Hg monitoring,
and, for EGU owners or operators who choose this option, the rule will
allow data collected during startup or shutdown periods to be used for
compliance purposes. The EPA expects little impact on Hg emissions
during startup or shutdown periods, because, as explained above, we
believe the rule contains sufficient variability to include startup and
shutdown periods; clean fuels will be used during those periods;
default diluent and electrical output values, which tend to constrain
emissions, will be available for use; and emissions occurring during
those periods will be included in a 30- (or 90-) boiler operating day
rolling average. EGU owners or operators may find that this third
approach would work well for those instances in which sudden and
unpredictable shutdown events occur, for there would be no need to swap
sorbent trap monitoring systems to capture shutdown emissions.
Finally, the EPA disagrees with commenters who claim that
collecting data during startup and shutdown will serve no purpose
relative to compliance with MATS and indicated that if the EPA needs to
collect startup and shutdown data to better understand performance for
a future rulemaking, that can be addressed through the information
collection request (ICR) process where the EPA demonstrates the need
and identifies a systematic plan to gather the data. As explained in
the final rule preamble,\17\ collection of startup and shutdown
information will provide the EPA with information to more fully analyze
the ability and appropriateness of establishing numeric emissions and
operating limits during startup periods or shutdown periods so the
issue can be addressed as part of the ongoing 8-year review of this
rule. Collection of these data as part of the rule will also serve to
reduce, if not eliminate, future ICR requests on this topic. The EPA
also disagrees with commenters who wish to place all startup and
shutdown information on those EGU owners or operators who choose to use
Hg CEMS, for EPA remains interested in how well sorbent tube monitoring
systems operate during startup periods or shutdown periods. Not
collecting that information from those systems would leave a gap in the
EPA's knowledge base.
---------------------------------------------------------------------------
\17\ See 77 FR 9382 (February 16, 2012).
---------------------------------------------------------------------------
Section 5.3 of the RTC contains both a summary of comments received
on this topic and the EPA's response to significant comments.
V. Summary of Final Action and Changes Since Proposal--Utility NSPS
The current PM startup and shutdown requirements in the Utility
NSPS are included in 40 CFR 60.42Da(e)(2) and require the owner/
operator of an affected EGU to meet the work practice standards
specified in Table 3 of 40 CFR Part 63, subpart UUUUU (i.e., the MATS
rule). The Utility NSPS docket received a total of 23 public comments
on the startup/shutdown reconsideration proposal. One of these comments
was a duplicate. Of the remaining 22 comments, 15 were received in both
dockets, and 7 were received in the Utility NSPS docket alone. Of the
seven comments received in the Utility NSPS docket alone, four were
said to be sent to the MATS docket, but no documents that matched the
ones in the Utility NSPS docket were found in the MATS docket. However,
the majority of the comments overlap with issues raised as part of the
startup and shutdown provision included in MATS. The EPA responses to
these issues are discussed in the MATS portion of the preamble and
docket and have not been repeated here or in the Utility NSPS docket.
The sole NSPS-specific comment we received was that the Utility
NSPS should include a definition of startup and shutdown that is
consistent with the MATS definition and that the definitions of startup
and shutdown in the Utility NSPS, MATS, and Industrial Boiler NESHAP
(subpart DDDDD) rules should be consistent. There are situations where
a facility is subject to the PM standard under 40 CFR Part 60, subpart
Da, but is not subject to MATS (e.g., a biomass-fired EGU with natural
gas burners >250 million British thermal units per hour). This facility
would, therefore, be subject to the Industrial Boiler NESHAP. We have
concluded that it is appropriate for industrial boilers and EGUs to
have the same PM startup and shutdown work practice standards for both
the NSPS and MATS. Therefore, we are amending 40 CFR 60.42Da(e)(2) so
that owners or operators of facilities subject to 40 CFR Part 63,
subpart UUUUU, shall meet the work practice standards specified in
Table 3 to Subpart UUUUU of Part 63, and owners or operators of
facilities subject to 40 CFR Part 63, subpart DDDDD, shall meet the
work practice standards specified in Table 3 to Subpart DDDDD of Part
63.
We are also amending the regulatory text in the Utility NSPS to
incorporate the relevant startup and shutdown definitions. We have
concluded that the amended regulatory text is sufficient, and adding
definitions of startup and shutdown are not necessary for the Utility
NSPS. Using this approach is beneficial because any future amendments
to the MATS startup and shutdown provisions will automatically be
incorporated into the Utility NSPS.
VI. Impacts of This Final Rule
A. Summary of Emissions Impacts, Costs and Benefits
Because this final rule is no more stringent than the February 2012
final rule, we expect no additional costs or benefits associated with
these revisions.
B. What are the air impacts?
This final rule is no more stringent than the February 2012 final
rule. Accordingly, we believe that this final action will not result in
significant changes in emissions of any of the regulated pollutants.
[[Page 68787]]
C. What are the energy impacts?
This final action is not anticipated to have an effect on the
supply, distribution, or use of energy. As previously stated, this
final rule is no more stringent than the February 2012 final rule.
D. What are the compliance costs?
We believe there will be no significant change in compliance costs
as a result of this final action because electric power companies would
take the same or similar actions (e.g., operating control devices,
recording clean fuel use, etc.) as they would have to comply with the
previously finalized MATS standards. Moreover, we find no additional
monitoring costs are necessary to comply with this final action because
EGU owners or operators could continue to use the startup and shutdown
provisions of the promulgated rule to demonstrate compliance; however,
as in any other rule, EGU owners or operators may choose to conduct
additional monitoring (and incur its expense) for their own purposes.
E. What are the economic and employment impacts?
Because we expect that electric power companies would take the same
or similar actions to meet the requirements finalized in this action as
they would have chosen to comply with the previously finalized MATS
standards, we do not anticipate that this final action will result in
significant changes in emissions, energy impacts, costs, benefits, or
economic impacts. Likewise, we believe this action will not have any
impacts on the price of electricity, employment or labor markets, or
the U.S. economy.
F. What are the benefits of the final standards?
As previously stated, we do not anticipate any significant emission
changes resulting from this action. Therefore, there are no direct
monetized benefits or disbenefits associated with this action.
VII. Statutory and Executive Order Reviews
A. Executive Order 12866: Regulatory Planning and Review and Executive
Order 13563: Improving Regulation and Regulatory Review
This action is not a ``significant regulatory action'' under the
terms of Executive Order 12866 (58 FR 51735; October 4, 1993) and is,
therefore not subject to review under Executive Orders 12866 and 13563
(76 FR 3821; January 21, 2011).
Because this final rule is no more stringent than the February 2012
final rule, we do not expect any additional costs, benefits, or
economic impacts associated with these revisions. The EPA prepared an
analysis of the potential costs and benefits associated with the 2012
final rule. This analysis is contained in the ``Economic Impact
Analysis for the Final Reconsideration of the Mercury and Air Toxics
Standards'' found in Docket ID No. EPA-HQ-OAR-2009-0234.
B. Paperwork Reduction Act
This action does not impose any new information collection burden.
This action clarifies but does not change the information collection
requirements previously finalized and, as a result, does not impose any
additional burden on industry. However, the Office of Management and
Budget (OMB) has previously approved the information collection
requirements contained in the existing regulations (see 77 FR 9304)
under the provisions of the Paperwork Reduction Act, 44 U.S.C. 3501 et
seq. and has assigned OMB control number 2060-0567. The OMB control
numbers for EPA's regulations are listed in 40 CFR part 9.
C. Regulatory Flexibility Act
The Regulatory Flexibility Act generally requires an agency to
prepare a regulatory flexibility analysis of any rule subject to notice
and comment rulemaking requirements under the Administrative Procedure
Act or any other statute unless the agency certifies that the rule will
not have a significant economic impact on a substantial number of small
entities. Small entities include small businesses, small organizations,
and small governmental jurisdictions.
For purposes of assessing the impacts of this action on small
entities, a small entity is defined as: (1) A small business as defined
by the Small Business Administration's (SBA) regulations at 13 CFR
121.201; (2) a small governmental jurisdiction that is a government of
a city, county, town, school district, or special district with a
population of less that 50,000; and (3) a small organization that is
any not-for-profit enterprise which is independently owned and operated
and is not dominant in its field. Categories and entities potentially
regulated by the final rule with applicable NAICS codes are provided in
section I.A of this preamble.
According to the SBA size standards for NAICS code 221122,
Utilities--Fossil Fuel Electric Power Generation, a firm is small if,
including its affiliates, it is primarily engaged in the generation,
transmission, and/or distribution of electric energy for sale and its
total electric output for the preceding fiscal year did not exceed 4
million MWh.
After considering the economic impacts of this final rule on small
entities, I certify that this action will not have a significant
economic impact on a substantial number of small entities.
The EPA has determined that none of the small entities will
experience a significant impact because the action imposes no
additional regulatory requirements on owners or operators of affected
sources.
D. Unfunded Mandates Reform Act
This action contains no federal mandates under the provisions of
Title II of the Unfunded Mandates Reform Act of 1995 (UMRA), 2 U.S.C.
1531-1538 for state, local, or tribal governments or the private
sector. The action imposes no enforceable duty on any state, local, or
tribal governments or the private sector. Therefore, this action is not
subject to the requirements of UMRA sections 202 or 205.
This action is also not subject to the requirements of UMRA section
203 because it contains no regulatory requirements that might
significantly or uniquely affect small governments. This action
contains no requirements that apply to such governments or impose
obligations upon them.
E. Executive Order 13132: Federalism
This action does not have federalism implications. It will not have
substantial direct effects on the states, on the relationship between
the national government and the states, or on the distribution of power
and responsibilities among the various levels of government, as
specified in Executive Order 13132. Thus, Executive Order 13132 does
not apply to this action.
F. Executive Order 13175: Consultation and Coordination With Indian
Tribal Governments
This action does not have tribal implications as specified in
Executive Order 13175 (65 FR 67249; November 9, 2000). It will not have
substantial direct effects on tribal governments, on the relationship
between the federal government and Indian tribes, or on the
distribution of power and responsibilities between the federal
government and Indian tribes, as specified in Executive Order 13175. No
affected facilities are owned or operated by Indian tribal governments.
Thus,
[[Page 68788]]
Executive Order 13175 does not apply to this action.
G. Executive Order 13045: Protection of Children From Environmental
Health Risks and Safety Risks
This action is not subject to Executive Order 13045 (62 FR 19885;
April 23, 1997) because it is not economically significant as defined
in Executive Order 12866. The EPA has evaluated the environmental
health or safety effects of the final MATS on children. The results of
the evaluation are discussed in that final rule (77 FR 9304; February
16, 2012) and are contained in Docket ID No. EPA-HQ-OAR-2009-0234.
H. Executive Order 13211: Actions That Significantly Affect Energy
Supply, Distribution, or Use
This action is not subject to Executive Order 13211 (66 FR 28355;
May 22, 2001) because it is not a significant regulatory action under
Executive Order 12866.
I. National Technology Transfer and Advancement Act
Section 12(d) of the National Technology Transfer and Advancement
Act of 1995 (NTTAA); Public Law 104-113, 12(d) (15 U.S.C. 272 note)
directs the EPA to use voluntary consensus standards (VCS) in their
regulatory and procurement activities unless to do so would be
inconsistent with applicable law or otherwise impracticable. VCS are
technical standards (e.g., material specifications, test methods,
sampling procedures, and business practices) that are developed or
adopted by VCS bodies. The NTTAA requires the EPA to provide Congress,
through OMB, explanations when the agency decides not to use available
and applicable VCS.
This action does not involve VCS. Therefore, the EPA did not
consider the use of any VCS.
J. Executive Order 12898: Federal Actions To Address Environmental
Justice in Minority Populations and Low-Income Populations
Executive Order 12898 (59 FR 7629; February 16, 1994) establishes
federal executive policy on environmental justice. Its main provision
directs federal agencies, to the greatest extent practicable and
permitted by law, to make environmental justice part of their mission
by identifying and addressing, as appropriate, disproportionately high
and adverse human health or environmental effects of their programs,
policies, and activities on minority populations and low-income
populations in the United States.
The EPA has determined that this final rule will not have
disproportionately high and adverse human health or environmental
effects on minority, low-income, or indigenous populations because it
does not affect the level of protection provided to human health or the
environment. The EPA has evaluated the environmental health or
environmental effects of the final MATS on minority, low-income, or
indigenous populations. The results of the evaluation are discussed in
that final rule (77 FR 9304; February 16, 2012) and are contained in
Docket ID No. EPA-HQ-OAR-2009-0234.
K. Congressional Review Act
The Congressional Review Act, 5 U.S.C. 801 et seq., as added by the
Small Business Regulatory Enforcement Fairness Act of 1996, generally
provides that before a rule may take effect, the agency promulgating
the rule must submit a rule report, which includes a copy of the rule,
to each House of the Congress and to the Comptroller General of the
United States. The EPA will submit a report containing this final rule
and other required information to the U.S. Senate, the U.S. House of
Representatives, and the Comptroller General of the United States prior
to publication of the rule in the Federal Register. A major rule cannot
take effect until 60 days after it is published in the Federal
Register. This action is not a ``major rule'' as defined by 5 U.S.C.
804(2). This final rule will be effective on November 19, 2014.
List of Subjects
40 CFR Part 60
Environmental protection, Administrative practice and procedure,
Air pollution control, Intergovernmental relations, Reporting and
recordkeeping requirements.
40 CFR Part 63
Environmental protection, Administrative practice and procedure,
Air pollution control, Hazardous substances, Intergovernmental
relations, Reporting and recordkeeping requirements.
Dated: November 7, 2014.
Gina McCarthy,
Administrator.
For the reasons discussed in the preamble, the EPA amends 40 CFR
parts 60 and 63 to read as follows:
PART 60--STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES
0
1. The authority citation for 40 CFR part 60 continues to read as
follows:
Authority: 42 U.S.C. 7401 et seq.
0
2. Section 60.42Da is amended by revising paragraph (e)(2) to read as
follows:
Sec. 60.42Da Standards for particulate matter (PM).
* * * * *
(e) * * *
(2) During startup periods and shutdown periods, owners or
operators of facilities subject to subpart UUUUU of part 63 of this
chapter shall meet the work practice standards specified in Table 3 to
subpart UUUUU of part 63 and use the relevant definitions in Sec.
63.10042, and owners or operators of facilities subject to subpart
DDDDD of part 63 shall meet the work practice standards specified in
Table 3 to subpart DDDDD of part 63 and use the relevant definition
used in Sec. 63.7575.
* * * * *
PART 63--NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS
FOR SOURCE CATEGORIES
0
3. The authority citation for 40 CFR part 63 continues to read as
follows:
Authority: 42 U.S.C. 7401 et seq.
0
4. Section 63.10000 is amended by revising paragraph (c)(1)(vi) and
adding paragraph (l) to read as follows:
Sec. 63.10000 What are my general requirements for complying with
this subpart?
* * * * *
(c)(1) * * *
(vi) If your coal-fired or solid oil-derived fuel-fired EGU does
not qualify as a LEE for Hg, you must demonstrate initial and
continuous compliance through use of a Hg CEMS or a sorbent trap
monitoring system, in accordance with appendix A to this subpart.
(A) You may choose to use separate sorbent trap monitoring systems
to comply with this subpart: One sorbent trap monitoring system to
demonstrate compliance with the numeric mercury emissions limit during
periods other than startup or shutdown and the other sorbent trap
monitoring system to report average mercury concentration during
startup periods or shutdown periods.
(B) You may choose to use one sorbent trap monitoring system to
demonstrate compliance with the mercury emissions limit at all times
[[Page 68789]]
(including startup periods and shutdown periods) and to report average
mercury concentration. You must follow the startup or shutdown
requirements that follow and as given in Table 3 to this subpart for
each coal-fired, liquid oil-fired, or solid oil-derived fuel-fired EGU.
* * * * *
(l) On or before the date an EGU is subject to this subpart, you
must install, certify, operate, maintain, and quality assure each
monitoring system necessary for demonstrating compliance with the work
practice standards for PM or non-mercury HAP metals during startup
periods and shutdown periods. You must collect, record, report, and
maintain data obtained from these monitoring systems during startup
periods and shutdown periods.
0
5. Section 63.10005 is amended by revising paragraph (a)(2) to read as
follows:
Sec. 63.10005 What are my initial compliance requirements and by what
date must I conduct them?
(a) * * *
(2) To demonstrate initial compliance using either a CMS that
measures HAP concentrations directly (i.e., an Hg, HCl, or HF CEMS, or
a sorbent trap monitoring system) or an SO2 or PM CEMS, the
initial performance test consists of 30- (or, if emissions averaging
for Hg is used, 90-) boiler operating days of data collected by the
initial compliance demonstration date specified in Sec. 63.9984(f)
with the certified monitoring system. Pollutant emission rates measured
during startup periods and shutdown period (as defined in Sec.
63.10042) are not to be included in the compliance demonstration,
except as otherwise provided in Sec. 63.10000(c)(1)(vi)(B) and
paragraph (a)(2)(iii) of this section.
(i) The 30- (or, if applicable, 90-) boiler operating day CMS
performance test must demonstrate compliance with the applicable Hg,
HCl, HF, PM, or SO2 emissions limit in Table 1 or 2 to this
subpart.
(ii) You must collect hourly data from auxiliary monitoring systems
(i.e., stack gas flow rate, CO2, O2, or moisture,
as applicable) during the performance test period, in order to convert
the pollutant concentrations to units of the standard. If you choose to
comply with an electrical output-based emission limit, you must also
collect hourly electrical load data during the performance test period.
(iii) For a group of affected units that are in the same
subcategory, are subject to the same emission standards, and share a
common stack, if you elect to demonstrate compliance by monitoring
emissions at the common stack, startup and shutdown emissions (if any)
that occur during the 30-(or, if applicable, 90-) boiler operating day
performance test must either be excluded from or included in the
compliance demonstration as follows:
(A) If one of the units that shares the stack either starts up or
shuts down at a time when none of the other units is operating, you
must exclude all pollutant emission rates measured during the startup
or shutdown period, unless you are using a sorbent trap monitoring
system to measure Hg emissions and have elected to include startup and
shutdown emissions in the compliance demonstrations;
(B) If all units that are currently operating are in the startup or
shutdown mode, you must exclude all pollutant emission rates measured
during the startup or shutdown period, unless you are using a sorbent
trap monitoring system to measure Hg emissions and have elected to
include startup and shutdown emissions in the compliance
demonstrations; or
(C) If any unit starts up or shuts down at a time when another unit
is operating, and the other unit is not in the startup or shutdown
mode, you must include all pollutant emission rates measured during the
startup or shutdown period in the compliance demonstrations.
* * * * *
0
6. Section 63.10007 is amended by revising paragraph (a)(1),
redesignating paragraph (f) as paragraph (g), and adding a new
paragraph (f) to read as follows:
Sec. 63.10007 What methods and other procedures must I use for the
performance tests?
(a) * * *
(1) If you use CEMS (Hg, HCl, SO2, or other) to
determine compliance with a 30- (or, if applicable, 90-) boiler
operating day rolling average emission limit, you must collect quality-
assured CEMS data for all unit operating conditions, including startup
and shutdown (see Sec. 63.10011(g) and Table 3 to this subpart),
except as otherwise provided in Sec. 63.10020(b). Emission rates
determined during startup periods and shutdown periods (as defined in
Sec. 63.10042) are not to be included in the compliance
determinations, except as otherwise provided in Sec. Sec.
63.10000(c)(1)(vi)(B) and 63.10005(a)(2)(iii).
* * * * *
(f) If you elect to (or are required to) use CEMS to continuously
monitor Hg, HCl, HF, SO2, or PM emissions (or, if
applicable, sorbent trap monitoring systems to continuously collect Hg
emissions data), the following default values are available for use in
the emission rate calculations during startup periods or shutdown
periods (as defined in Sec. 63.10042). For the purposes of this
subpart, these default values are not considered to be substitute data.
(1) Diluent cap values. If you use CEMS (or, if applicable, sorbent
trap monitoring systems) to comply with a heat input-based emission
rate limit, you may use the following diluent cap values for a startup
or shutdown hour in which the measured CO2 concentration is
below the cap value or the measured O2 concentration is
above the cap value:
(i) For an IGCC EGU, you may use 1% for CO2 or 19% for
O2.
(ii) For all other EGUs, you may use 5% for CO2 or 14%
for O2.
(2) Default electrical load. If you use CEMS to continuously
monitor Hg, HCl, HF, SO2, or PM emissions (or, if
applicable, sorbent trap monitoring systems to continuously collect Hg
emissions data), the following default value is available for use in
the emission rate calculations during startup periods or shutdown
periods (as defined in Sec. 63.10042). For the purposes of this
subpart, this default value is not considered to be substitute data.
For a startup or shutdown hour in which there is heat input to an
affected EGU but zero electrical load, you must calculate the pollutant
emission rate using a value equivalent to 5% of the maximum sustainable
electrical output, expressed in megawatts, as defined in section
6.5.2.1(a)(1) of Appendix A to part 75 of this chapter. This default
electrical load is either the nameplate capacity of the EGU or the
highest electrical load observed in at least four representative
quarters of EGU operation. For a monitored common stack, the default
electrical load is used only when all EGUs are operating (i.e.,
combusting fuel) are in startup or shutdown mode, and have zero
electrical generation. Under those conditions, a default electrical
load equal to 5% of the combined maximum sustainable electrical load of
the EGUs that are operating but have a total of zero electrical load
must be used to calculate the hourly electrical output-based pollutant
emissions rate.
* * * * *
0
7. Section 63.10010 is amended by revising paragraph (f)(4) and adding
paragraph (l) to read as follows:
Sec. 63.10010 What are my monitoring, installation, operation, and
maintenance requirements?
* * * * *
[[Page 68790]]
(f) * * *
(4) Use only unadjusted, quality-assured SO2
concentration values in the emissions calculations; do not apply bias
adjustment factors to the part 75 SO2 data and do not use
part 75 substitute data values. For startup or shutdown hours (as
defined in Sec. 63.10042) the default electrical load and the diluent
cap are available for use in the hourly SO2 emission rate
calculations, as described in Sec. 63.10007(f). Use a flag to identify
each startup or shutdown hour and report a special code if the diluent
cap or default electrical load is used to calculate the SO2
emission rate for any of these hours.
* * * * *
(l) You must install, certify, operate, maintain, and quality
assure each monitoring system necessary for demonstrating compliance
with the PM or non-mercury metals work practice standards for startup
periods.
(1) You shall develop a site-specific monitoring plan for PM or
non-mercury metals work practice monitoring during startup periods.
(2) You shall submit the site-specific monitoring plan upon request
by the Administrator.
(3) The provisions of the monitoring plan must address the
following items:
(i) Monitoring system installation;
(ii) Performance and equipment specifications;
(iii) Schedule for initial and periodic performance evaluations;
(iv) Performance evaluation procedures and acceptance criteria;
(v) On-going operation and maintenance procedures; and
(vi) On-going recordkeeping and reporting procedures.
(4) You may rely on monitoring system specifications or
instructions to address paragraphs (l)(3)(i) through (vi) of this
section.
(5) You must operate and maintain the monitoring system according
to the site-specific monitoring plan.
0
8. Section 63.10011 is amended by revising paragraph (g) to read as
follows:
Sec. 63.10011 How do I demonstrate initial compliance with the
emission limits and work practice standards?
* * * * *
(g) You must follow the startup or shutdown requirements as given
in Table 3 to this subpart for each coal-fired, liquid oil-fired, or
solid oil-derived fuel-fired EGU.
(1) You may use the diluent cap and default electrical load values,
as described in Sec. 63.10007(f), during startup periods or shutdown
periods.
(2) You must operate all CMS, collect data, calculate pollutant
emission rates, and record data during startup periods or shutdown
periods.
(3) You must report the information as required in Sec. 63.10031.
(4) If you choose to use paragraph (2) of the definition of
``startup'' in Sec. 63.10042 and you find that you are unable to
safely engage and operate your particulate matter (PM) control(s)
within 1 hour of first firing of coal, residual oil, or solid oil-
derived fuel, you may choose to rely on paragraph (1) of definition of
``startup'' in Sec. 63.10042 or you may submit a request to use an
alternative non-opacity emissions standard, as described below.
(i) As mentioned in Sec. 63.6(g)(1), the request will be published
in the Federal Register for notice and comment rulemaking. Until
promulgation in the Federal Register of the final alternative non-
opacity emission standard, you shall comply with paragraph (1) of the
definition of ``startup'' in Sec. 63.10042. You shall not implement
the alternative non-opacity emissions standard until promulgation in
the Federal Register of the final alternative non-opacity emission
standard.
(ii) The request need not address the items contained in Sec.
63.6(g)(2).
(iii) The request shall provide evidence of a documented
manufacturer-identified safely issue.
(iv) The request shall provide information to document that the PM
control device is adequately designed and sized to meet the PM emission
limit applicable to the EGU.
(v) In addition, the request shall contain documentation that:
(A) The EGU is using clean fuels to the maximum extent possible to
bring the EGU and PM control device up to the temperature necessary to
alleviate or prevent the identified safety issues prior to the
combustion of primary fuel in the EGU;
(B) The EGU has explicitly followed the manufacturer's procedures
to alleviate or prevent the identified safety issue; and
(C) Identifies with specificity the details of the manufacturer's
statement of concern.
(vi) The request shall specify the other work practice standards
the EGU owner or operator will take to limit HAP emissions during
startup periods and shutdown periods to ensure a control level
consistent with the work practice standards of the final rule.
(vii) You must comply with all other work practice requirements,
including but not limited to data collection, recordkeeping, and
reporting requirements.
0
9. Section 63.10020 is amended by revising paragraph (c) and adding
paragraph (e) to read as follows:
Sec. 63.10020 How do I monitor and collect data to demonstrate
continuous compliance?
* * * * *
(c) You may not use data recorded during EGU startup or shutdown in
calculations used to report emissions, except as otherwise provided in
Sec. Sec. 63.10000(c)(1)(vi)(B) and 63.10005(a)(2)(iii). In addition,
data recorded during monitoring system malfunctions or monitoring
system out-of-control periods, repairs associated with monitoring
system malfunctions or monitoring system out-of-control periods, or
required monitoring system quality assurance or control activities may
not be used in calculations used to report emissions or operating
levels. You must use all of the quality-assured data collected during
all other periods in assessing the operation of the control device and
associated control system.
* * * * *
(e) Additional requirements during startup periods or shutdown
periods.
(1) During each period of startup, you must record for each EGU:
(i) The date and time that clean fuels being combusted for the
purpose of startup begins;
(ii) The quantity and heat input of clean fuel for each hour of
startup;
(iii) The electrical load for each hour of startup;
(iv) The date and time that non-clean fuel combustion begins; and
(v) The date and time that clean fuels being combusted for the
purpose of startup ends.
(2) During each period of shutdown, you must record for each EGU:
(i) The date and time that clean fuels being combusted for the
purpose of shutdown begins;
(ii) The quantity and heat input of clean fuel for each hour of
shutdown;
(iii) The electrical load for each hour of shutdown;
(iv) The date and time that non-clean fuel combustion ends; and
(v) The date and time that clean fuels being combusted for the
purpose of shutdown ends.
(3) For PM or non-mercury HAP metals work practice monitoring
during startup periods, you must monitor and collect data according to
this section and the site-specific monitoring plan required by Sec.
63.10011(l).
(i) Except for an EGU that uses PM CEMS or PM CPMS to demonstrate
compliance with the PM emissions limit or that has LEE status for
filterable PM or total non-Hg HAP metals for non-
[[Page 68791]]
liquid oil-fired EGUs (or HAP metals emissions for liquid oil-fired
EGUs), or individual non-mercury metals CEMS you must:
(A) Record temperature and flow rate of post-combustion (exhaust)
gas and amperage of forced draft fan(s) upstream of each filterable PM
control device during each hour of startup.
(B) Record temperature and flow rate of exhaust gas and amperage of
induced draft fan(s) downstream of each filterable control device
during each hour of startup.
(C) For an EGU with an electrostatic precipitator, record the
number of fields in service, as well as each field's secondary voltage
and secondary current during each hour of startup.
(D) For an EGU with a fabric filter, record the number of
compartments in service, as well as the differential pressure across
the baghouse during each hour of startup.
(E) For an EGU with a wet scrubber needed for filterable PM
control, record the scrubber liquid to fuel ratio and the differential
pressure of the liquid during each hour of startup.
(ii) [Reserved]
0
10. Section 63.10021 is amended by revising paragraph (h) to read as
follows:
Sec. 63.10021 How do I demonstrate continuous compliance with the
emission limitations, operating limits, and work practice standards?
* * * * *
(h) You must follow the startup or shutdown requirements as given
in Table 3 to this subpart for each coal-fired, liquid oil-fired, or
solid oil-derived fuel-fired EGU.
(1) You may use the diluent cap and default electrical load values,
as described in Sec. 63.10007(f), during startup periods or shutdown
periods.
(2) You must operate all CMS, collect data, calculate pollutant
emission rates, and record data during startup periods or shutdown
periods.
(3) You must report the information as required in Sec. 63.10031.
(4) You may choose to submit an alternative non-opacity emission
standard, in accordance with the requirements contained in Sec.
63.10011(g)(4). Until promulgation in the Federal Register of the final
alternative non-opacity emission standard, you shall comply with
paragraph (1) of the definition of ``startup'' in Sec. 63.10042.
* * * * *
0
11. Section 63.10022 is amended by revising the introductory text of
paragraph (a) and adding paragraph (a)(4) to read as follows:
Sec. 63.10022 How do I demonstrate continuous compliance under the
emissions averaging provision?
(a) Following the compliance date, the owner or operator must
demonstrate compliance with this subpart on a continuous basis by
meeting the requirements of paragraphs (a)(1) through (4) of this
section.
* * * * *
(4) For each existing EGU participating in the emissions averaging
option, operate in accordance with the startup or shutdown work
practice requirements given in Table 3 to this subpart.
* * * * *
0
12. Section 63.10030 is amended by revising the introductory text of
paragraph (e) and adding paragraph (e)(8) to read as follows:
Sec. 63.10030 What notifications must I submit and when?
* * * * *
(e) When you are required to conduct an initial compliance
demonstration as specified in Sec. 63.10011(a), you must submit a
Notification of Compliance Status according to Sec. 63.9(h)(2)(ii).
The Notification of Compliance Status report must contain all the
information specified in paragraphs (e)(1) through (8) of this section,
as applicable.
* * * * *
(8) Identification of whether you plan to rely on paragraph (1) or
(2) of the definition of ``startup'' in Sec. 63.10042.
(i) Should you choose to rely on paragraph (2) of the definition of
``startup'' in Sec. 63.10042 for your EGU, you shall include a report
that identifies:
(A) The original EGU installation date;
(B) The original EGU design characteristics, including, but not
limited to, fuel and PM controls;
(C) Each design PM control device efficiency;
(D) The design PM emission rate from the EGU in terms of pounds PM
per MMBtu and pounds PM per hour;
(E) The design time from start of fuel combustion to necessary
conditions for each PM control device startup;
(F) Each design PM control device efficiency upon startup of the PM
control device;
(G) The design EGU uncontrolled PM emission rate in terms of pounds
PM per hour;
(H) Each change from the original design that did or could have
changed PM emissions, including, but not limited to, each different
fuel mix, each revision to each PM control device, and each EGU
revision, along with the month and year that the change occurred;
(I) Current EGU PM producing characteristics, including, but not
limited to, fuel mix and PM controls;
(J) Current PM emission rate from the EGU in terms of pounds PM per
MMBtu and pounds per hour;
(K) Current PM control device efficiency from each PM control
device;
(L) Current time from start of fuel combustion to conditions
necessary for each PM control device startup;
(M) Current PM control device efficiency upon startup of each PM
control device; and
(N) Current EGU uncontrolled PM emission rate in terms of pounds PM
per hour.
(ii) The report shall be prepared, signed, and sealed by a
professional engineer licensed in the state where your EGU is located.
Apart from preparing, signing, and sealing this report, the
professional engineer shall be independent and not otherwise employed
by your company, any parent company of your company, or any subsidiary
of your company.
0
13. Section 63.10031 is amended by revising the introductory text of
paragraph (c) and adding paragraph (c)(5) to read as follows:
Sec. 63.10031 What reports must I submit and when?
* * * * *
(c) The compliance report must contain the information required in
paragraphs (c)(1) through (5) of this section.
* * * * *
(5) For each instance of startup or shutdown:
(i) Include the maximum clean fuel storage capacity and the maximum
hourly heat input that can be provided for each clean fuel determined
according to the requirements of Sec. 63.10032(f).
(ii) Include the information required to be monitored, collected,
or recorded according to the requirements of Sec. 63.10020(e).
(iii) If you choose to use CEMS for compliance purposes, include
hourly average CEMS values and hourly average flow rates. Use units of
milligrams per cubic meter for PM CEMS, micrograms per cubic meter for
Hg CEMS, and ppmv for HCl, HF, or SO2 CEMS. Use units of
standard cubic meters per hour on a wet basis for flow rates.
(iv) If you choose to use a separate sorbent trap measurement
system for startup or shutdown reporting periods, include hourly
average mercury
[[Page 68792]]
concentration in terms of micrograms per cubic meter.
(v) If you choose to use a PM CPMS, include hourly average
operating parameter values in terms of the operating limit, as well as
the operating parameter to PM correlation equation.
* * * * *
0
14. Section 63.10032 is amended by revising paragraph (f) to read as
follows:
Sec. 63.10032 What records must I keep?
* * * * *
(f) Regarding startup periods or shutdown periods:
(1) You must keep records of the occurrence and duration of each
startup or shutdown;
(2) You must keep records of the determination of the maximum clean
fuel capacity for each EGU;
(3) You must keep records of the determination of the maximum
hourly clean fuel heat input and of the hourly clean fuel heat input
for each EGU; and
(4) You must keep records of the information required in Sec.
63.10020(e).
* * * * *
0
15. In Sec. 63.10042:
0
a. Revise the definitions for ``Boiler operating day,'' ``Shutdown'',
and ``Startup''; and
0
b. Add in alphabetical order new definitions for ``Clean fuel,''
``Default electrical load,'' and ``Diluent cap.''
The revisions and additions read as follows:
Sec. 63.10042 What definitions apply to this subpart?
* * * * *
Boiler operating day means a 24-hour period that begins at midnight
and ends the following midnight during which any fuel is combusted at
any time in the EGU, excluding startup periods or shutdown periods. It
is not necessary for the fuel to be combusted the entire 24-hour
period.
* * * * *
Clean fuel means natural gas, synthetic natural gas that meets the
specification necessary for that gas to be transported on a Federal
Energy Regulatory Commission (FERC) regulated pipeline, propane,
distillate oil, synthesis gas that has been processed through a gas
clean-up train such that it could be used in a system's combustion
turbine, or ultra-low-sulfur diesel (ULSD) oil, including those fuels
meeting the requirements of 40 CFR part 80, subpart I (``Subpart I--
Motor Vehicle Diesel Fuel; Nonroad, Locomotive, and Marine Diesel Fuel;
and ECA Marine Fuel'').
* * * * *
Default electrical load means an electrical load equal to 5 percent
of the maximum sustainable electrical output (megawatts), as defined in
section 6.5.2.1(a)(1) of Appendix A to part 75 of this chapter, of an
affected EGU that is in startup or shutdown mode. For monitored common
stack configurations, the default electrical load is 5 percent of the
combined maximum sustainable electrical load of the EGUs that are in
startup or shutdown mode during an hour in which the electrical load
for all operating EGUs is zero. The default electrical load is used to
calculate the electrical output-based emission rate (lb/MWh or lb/GWh,
as applicable) for any startup or shutdown hour in which the actual
electrical load is zero. The default electrical load is not used for
EGUs required to make heat input-based emission rate (lb/MMBtu or lb/
TBtu, as applicable) calculations. For the purposes of this subpart,
the default electrical load is not considered to be a substitute data
value.
* * * * *
Diluent cap means a default CO2 or O2
concentration that may be used to calculate the Hg, HCl, HF, or
SO2 emission rate (lb/MMBtu or lb/TBtu, as applicable)
during a startup or shutdown hour in which the measured CO2
concentration is below the cap value or the measured O2
concentration is above the cap value. The appropriate diluent cap
values for EGUs are presented in Sec. 63.10007(f) and in section
6.2.1.2 of Appendix A to this subpart. For the purposes of this
subpart, the diluent cap is not considered to be a substitute data
value.
* * * * *
Shutdown means the period in which cessation of operation of an EGU
is initiated for any purpose. Shutdown begins when the EGU no longer
generates electricity or makes useful thermal energy (such as heat or
steam) for industrial, commercial, heating, or cooling purposes or when
no coal, liquid oil, syngas, or solid oil-derived fuel is being fired
in the EGU, whichever is earlier. Shutdown ends when the EGU no longer
generates electricity or makes useful thermal energy (such as steam or
heat) for industrial, commercial, heating, or cooling purposes, and no
fuel is being fired in the EGU. Any fraction of an hour in which
shutdown occurs constitutes a full hour of shutdown.
Startup means:
(1) Either the first-ever firing of fuel in a boiler for the
purpose of producing electricity, or the firing of fuel in a boiler
after a shutdown event for any purpose. Startup ends when any of the
steam from the boiler is used to generate electricity for sale over the
grid or for any other purpose (including on-site use). Any fraction of
an hour in which startup occurs constitutes a full hour of startup; or
(2) The period in which operation of an EGU is initiated for any
purpose. Startup begins with either the firing of any fuel in an EGU
for the purpose of producing electricity or useful thermal energy (such
as heat or steam) for industrial, commercial, heating, or cooling
purposes (other than the first-ever firing of fuel in a boiler
following construction of the boiler) or for any other purpose after a
shutdown event. Startup ends 4 hours after the EGU generates
electricity that is sold or used for any other purpose (including on
site use), or 4 hours after the EGU makes useful thermal energy (such
as heat or steam) for industrial, commercial, heating, or cooling
purposes (16 U.S.C. 796(18)(A) and 18 CFR 292.202(c)), whichever is
earlier. Any fraction of an hour in which startup occurs constitutes a
full hour of startup.
* * * * *
0
16. Revise Table 3 to subpart UUUUU of part 63 to read as follows:
Table 3 to Subpart UUUUU of Part 63--Work Practice Standards
[As stated in Sec. 63.9991, you must comply with the following
applicable work practice standards:]
------------------------------------------------------------------------
If your EGU is . . . You must meet the following . . .
------------------------------------------------------------------------
1. An existing EGU........... Conduct a tune-up of the EGU burner and
combustion controls at least each 36
calendar months, or each 48 calendar
months if neural network combustion
optimization software is employed, as
specified in Sec. 63.10021(e).
2. A new or reconstructed EGU Conduct a tune-up of the EGU burner and
combustion controls at least each 36
calendar months, or each 48 calendar
months if neural network combustion
optimization software is employed, as
specified in Sec. 63.10021(e).
[[Page 68793]]
3. A coal-fired, liquid oil- You have the option of complying using
fired (excluding limited-use either of the following work practice
liquid oil-fired subcategory standards.
units), or solid oil-derived (1) If you choose to comply using
fuel-fired EGU during paragraph (1) of the definition of
startup. ``startup'' in Sec. 63.10042, you must
operate all CMS during startup. Startup
means either the first-ever firing of
fuel in a boiler for the purpose of
producing electricity, or the firing of
fuel in a boiler after a shutdown event
for any purpose. Startup ends when any
of the steam from the boiler is used to
generate electricity for sale over the
grid or for any other purpose (including
on site use). For startup of a unit, you
must use clean fuels as defined in Sec.
63.10042 for ignition. Once you convert
to firing coal, residual oil, or solid
oil-derived fuel, you must engage all of
the applicable control technologies
except dry scrubber and SCR. You must
start your dry scrubber and SCR systems,
if present, appropriately to comply with
relevant standards applicable during
normal operation. You must comply with
all applicable emissions limits at all
times except for periods that meet the
applicable definitions of startup and
shutdown in this subpart. You must keep
records during startup periods. You must
provide reports concerning activities
and startup periods, as specified in
Sec. 63.10011(g) and Sec.
63.10021(h) and (i).
(2) If you choose to comply using
paragraph (2) of the definition of
``startup'' in Sec. 63.10042, you must
operate all CMS during startup. You must
also collect appropriate data, and you
must calculate the pollutant emission
rate for each hour of startup.
For startup of an EGU, you must use one
or a combination of the clean fuels
defined in Sec. 63.10042 to the
maximum extent possible throughout the
startup period. You must have sufficient
clean fuel capacity to engage and
operate your PM control device within
one hour of adding coal, residual oil,
or solid oil-derived fuel to the unit.
You must meet the startup period work
practice requirements as identified in
Sec. 63.10020(e).
Once you start firing coal, residual oil,
or solid oil-derived fuel, you must vent
emissions to the main stack(s). You must
comply with the applicable emission
limits within 4 hours of start of
electricity generation. You must engage
and operate your particulate matter
control(s) within 1 hour of first firing
of coal, residual oil, or solid oil-
derived fuel.
You must start all other applicable
control devices as expeditiously as
possible, considering safety and
manufacturer/supplier recommendations,
but, in any case, when necessary to
comply with other standards made
applicable to the EGU by a permit limit
or a rule other than this Subpart that
require operation of the control
devices.
Relative to the syngas not fired in the
combustion turbine of an IGCC EGU during
startup, you must either: (1) flare the
syngas, or (2) route the syngas to duct
burners, which may need to be installed,
and route the flue gas from the duct
burners to the heat recovery steam
generator.
If you choose to use just one set of
sorbent traps to demonstrate compliance
with Hg emission limits, you must comply
with all applicable Hg emission limits
at all times; otherwise, you must comply
with all applicable emission limits at
all times except for startup or shutdown
periods conforming to this practice. You
must collect monitoring data during
startup periods, as specified in Sec.
63.10020(a) and (e). You must keep
records during startup periods, as
provided in Sec. Sec. 63.10032 and
63.10021(h). Any fraction of an hour in
which startup occurs constitutes a full
hour of startup. You must provide
reports concerning activities and
startup periods, as specified in Sec.
Sec. 63.10011(g), 63.10021(i), and
63.10031.
4. A coal-fired, liquid oil- You must operate all CMS during shutdown.
fired (excluding limited-use You must also collect appropriate data,
liquid oil-fired subcategory and you must calculate the pollutant
units), or solid oil-derived emission rate for each hour of shutdown.
fuel-fired EGU during While firing coal, residual oil, or solid
shutdown. oil-derived fuel during shutdown, you
must vent emissions to the main stack(s)
and operate all applicable control
devices and continue to operate those
control devices after the cessation of
coal, residual oil, or solid oil-derived
fuel being fed into the EGU and for as
long as possible thereafter considering
operational and safety concerns. In any
case, you must operate your controls
when necessary to comply with other
standards made applicable to the EGU by
a permit limit or a rule other than this
Subpart and that require operation of
the control devices.
If, in addition to the fuel used prior to
initiation of shutdown, another fuel
must be used to support the shutdown
process, that additional fuel must be
one or a combination of the clean fuels
defined in Sec. 63.10042 and must be
used to the maximum extent possible.
Relative to the syngas not fired in the
combustion turbine of an IGCC EGU during
shutdown, you must either: (1) flare the
syngas, or (2) route the syngas to duct
burners, which may need to be installed,
and route the flue gas from the duct
burners to the heat recovery steam
generator.
You must comply with all applicable
emission limits at all times except
during startup periods and shutdown
periods at which time you must meet this
work practice. You must collect
monitoring data during shutdown periods,
as specified in Sec. 63.10020(a). You
must keep records during shutdown
periods, as provided in Sec. Sec.
63.10032 and 63.10021(h). Any fraction
of an hour in which shutdown occurs
constitutes a full hour of shutdown. You
must provide reports concerning
activities and shutdown periods, as
specified in Sec. Sec. 63.10011(g),
63.10021(i), and 63.10031.
------------------------------------------------------------------------
[[Page 68794]]
0
17. Revise Table 9 to subpart UUUUU of part 63 to read as follows:
Table 9 to Subpart UUUUU of Part 63--Applicability of General Provisions to Subpart UUUUU
[As stated in Sec. 63.10040, you must comply with the applicable General Provisions according to the
following]
----------------------------------------------------------------------------------------------------------------
Citation Subject Applies to subpart UUUUU
----------------------------------------------------------------------------------------------------------------
Sec. 63.1........................... Applicability................. Yes.
Sec. 63.2........................... Definitions................... Yes. Additional terms defined in Sec.
63.10042.
Sec. 63.3........................... Units and Abbreviations....... Yes.
Sec. 63.4........................... Prohibited Activities and Yes.
Circumvention.
Sec. 63.5........................... Preconstruction Review and Yes.
Notification Requirements.
Sec. 63.6(a), (b)(1)-(5), (b)(7), Compliance with Standards and Yes.
(c), (f)(2)-(3), (h)(2)-(9), (i), (j). Maintenance Requirements.
Sec. 63.6(e)(1)(i).................. General Duty to minimize No. See Sec. 63.10000(b) for general
emissions. duty requirement.
Sec. 63.6(e)(1)(ii)................. Requirement to correct No.
malfunctions ASAP.
Sec. 63.6(e)(3)..................... SSM Plan requirements......... No.
Sec. 63.6(f)(1)..................... SSM exemption................. No.
Sec. 63.6(h)(1)..................... SSM exemption................. No.
Sec. 63.6(g)........................ Compliance with Standards and Yes. See Sec. Sec. 63.10011(g)(4) and
Maintenance Requirements, Use 63.10021(h)(4) for additional
of an alternative non-opacity requirements.
emission standard.
Sec. 63.7(e)(1)..................... Performance testing........... No. See Sec. 63.10007.
Sec. 63.8........................... Monitoring Requirements....... Yes.
Sec. 63.8(c)(1)(i).................. General duty to minimize No. See Sec. 63.10000(b) for general
emissions and CMS operation. duty requirement.
Sec. 63.8(c)(1)(iii)................ Requirement to develop SSM No.
Plan for CMS.
Sec. 63.8(d)(3)..................... Written procedures for CMS.... Yes, except for last sentence, which
refers to an SSM plan. SSM plans are
not required.
Sec. 63.9........................... Notification Requirements..... Yes.
Sec. 63.10(a), (b)(1), (c), (d)(1)- Recordkeeping and Reporting Yes, except for the requirements to
(2), (e), and (f). Requirements. submit written reports under Sec.
63.10(e)(3)(v).
Sec. 63.10(b)(2)(i)................. Recordkeeping of occurrence No.
and duration of startups and
shutdowns.
Sec. 63.10(b)(2)(ii)................ Recordkeeping of malfunctions. No. See Sec. 63.10001 for
recordkeeping of (1) occurrence and
duration and (2) actions taken during
malfunction.
Sec. 63.10(b)(2)(iii)............... Maintenance records........... Yes.
Sec. 63.10(b)(2)(iv)................ Actions taken to minimize No.
emissions during SSM.
Sec. 63.10(b)(2)(v)................. Actions taken to minimize No.
emissions during SSM.
Sec. 63.10(b)(2)(vi)................ Recordkeeping for CMS Yes.
malfunctions.
Sec. 63.10(b)(2)(vii)-(ix).......... Other CMS requirements........ Yes.
Sec. 63.10(b)(3), and (d)(3)-(5).... .............................. No.
Sec. 63.10(c)(7).................... Additional recordkeeping Yes.
requirements for CMS--
identifying exceedances and
excess emissions.
Sec. 63.10(c)(8).................... Additional recordkeeping Yes.
requirements for CMS--
identifying exceedances and
excess emissions.
Sec. 63.10(c)(10)................... Recording nature and cause of No. See Sec. 63.10032(g) and (h) for
malfunctions. malfunctions recordkeeping
requirements.
Sec. 63.10(c)(11)................... Recording corrective actions.. No. See Sec. 63.10032(g) and (h) for
malfunctions recordkeeping
requirements.
Sec. 63.10(c)(15)................... Use of SSM Plan............... No.
Sec. 63.10(d)(5).................... SSM reports................... No. See Sec. 63.10021(h) and (i) for
malfunction reporting requirements.
Sec. 63.11.......................... Control Device Requirements... No.
Sec. 63.12.......................... State Authority and Delegation Yes.
Sec. Sec. 63.13-63.16.............. Addresses, Incorporation by Yes.
Reference, Availability of
Information, Performance
Track Provisions.
Sec. Sec. 63.1(a)(5), (a)(7)-(9), Reserved...................... No.
(b)(2), (c)(3)-(4), (d), 63.6(b)(6),
(c)(3), (c)(4), (d), (e)(2),
(e)(3)(ii), (h)(3), (h)(5)(iv),
63.8(a)(3), 63.9(b)(3), (h)(4),
63.10(c)(2)-(4), (c)(9).
----------------------------------------------------------------------------------------------------------------
[[Page 68795]]
0
18. Appendix A to subpart UUUUU is amended by adding sections 7.1.2.5,
7.1.8.5, and 7.1.8.6, to read as follows:
Appendix A to Subpart UUUUU of Part 63--Hg Monitoring Provisions
* * * * *
7. Recordkeeping and Reporting
* * * * *
7.1.2 Operating Parameter Records. * * *
* * * * *
7.1.2.5 If applicable, a flag to indicate that the hour is a
startup or shutdown hour (as defined in Sec. 63.10042).
* * * * *
7.1.8 Hg Emission Rate Records. * * *
* * * * *
7.1.8.5 If applicable, a code to indicate that the default
electrical load (as defined in Sec. 63.10042) was used to calculate
the Hg emission rate.
7.1.8.6 If applicable, a code to indicate that the diluent cap (as
defined in Sec. 63.10042) was used to calculate the Hg emission rate.
* * * * *
0
19. Appendix B to subpart UUUUU is amended by revising section 9.3.1
and adding sections 10.1.2.5, 10.1.7.5, and 10.1.7.6 to read as
follows:
Appendix B to Subpart UUUUU of Part 63---HCl and HF Monitoring
Provisions
* * * * *
9. Data Reduction and Calculations
* * * * *
9.3.1 For heat input-based emission rates, select an appropriate
emission rate equation from among Equations 19-1 through 19-9 in EPA
Method 19 in Appendix A-7 to part 60 of this chapter, to calculate the
HCl or HF emission rate in lb/MMBtu. Multiply the HCl concentration
value (ppm) by 9.43 x 10-8 to convert it to lb/scf, for use
in the applicable Method 19 equation. For HF, the conversion constant
from ppm to lb/scf is 5.18 x 10-8. The appropriate diluent
cap value from section 6.2.1.2 of Appendix A to this subpart may be
used to calculate the HCl or HF emission rate (lb/MMBtu) during startup
or shutdown hours.
* * * * *
10. Recordkeeping Requirements
* * * * *
10.1.2 Operating Parameter Records. * * *
* * * * *
10.1.2.5 If applicable, a flag to indicate that the hour is a
startup or shutdown hour (as defined in Sec. 63.10042).
* * * * *
10.1.7 HCl and HF Emission Rate Records. * * *
* * * * *
10.1.7.5 If applicable, a code to indicate that the default
electrical load (as defined in Sec. 63.10042) was used to calculate
the HCl or HF emission rate.
10.1.7.6 If applicable, a code to indicate that the diluent cap (as
defined in Sec. 63.10042) was used to calculate the HCl or HF emission
rate.
* * * * *
[FR Doc. 2014-27125 Filed 11-18-14; 8:45 am]
BILLING CODE 6560-50-P